RHC & RHCE gas fired heating coils

Similar documents
RHC GAS FIRED HEATING COILS

Gas-fired unit heaters for indoor installation

... UDSA - UDSBD Gas fired unit heaters...

PREEVA air handling unit

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... Air Conditioners & Heat Pumps Light Commercial ...

DF-IDF air handling units

... DF / IDF Gas fired combined heating and ventilation ...

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

Application instructions

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

AMBIRAD.... Vision Radiant Tube Heating Systems...

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

CITY OPEN - CITY BOX from 25 to 35 kw

INSTALLATION AND OPERATION MANUAL

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

BENSON.... Variante3 Fired Unit Heaters...

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

PRESENTATION OF DAEWOO GAS BOILER

CP+ Gas & Oil Cabinet Heater Range

Cast Iron Boilers. G Series ( kW)

... RTU. Packaged Air to Air Heat Pump...

LBF RANGE BALANCED FLUED WATER HEATERS

DAIKIN Air Handling Unit Modular

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

Gas fired rooftops. Comfort all year round

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

G34M Bulletin #69/ August 2003

The ultimate in air handling units: directly and indirectly fired

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Flue gas condensation...

PC-120 FLATWORK IRONERS. Advanced ironers for superior productivity, efficiency and quality results.

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Product catalogue Pleszew, 2015

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

Product Line Introduction. Karl Zhang Technical support engineer

The ultimate in air handling units: directly and indirectly fired

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Condensing, pre-mixed, wall-hung gas boilers with water tank

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

When you have a Bonaire ducted gas heater installed, you won t know it is winter until you look out the window Ducted Gas Heating Range

WHY A MHI HEAT PUMP?

AHRI Certification Program Scopes - COOLING

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

EFFICIENCY RELIABILITY

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

Appendix 13. Categories of Cooling and Heating systems

FIREPLACE INSERTS. SINCE 1960

C Tahiti. condensing

1 VICTRIX ZEUS Superior kw I features

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Series PS6, Vertical Floor-Mount Units

HEM Heat Exchange Modules

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

The ultimate in air handling units: directly and indirectly fired

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

next DX.U.S* 052.Z2.H6.DC

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

13 GEP A L P - 1 A

EC L2. and humidity sensors. All units are supplied tested and ready to install.

NEW * for buildings 2-24 floors

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Exhaust Duct Design Page 1 of (C)

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

MX RANGE PACKAGED STEAM BOILERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks

SCR and SCR-ECO PREMIX CERAMIC HEATERS WITH MODULATION AND ON/OFF HEATING COOLING GREEN ENERGY RADIANT HEATING TECHNOLOGY AND INNOVATION

AIR COOLED CONDENSERS

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

GAS ABSORPTION HEAT PUMP

New Zealand Sales Hotline: Sales Fax:

Gas heaters and convectors ROBUR

Transcription:

APPLICATIONS Heating in duct networks or air handling units >> FACTORIES >> WAREHOUSES >> HALLS RHC & RHCE gas fired heating coils www.reznor.eu

RHC gas fired heating coils Reznor gas fired heating coils further extend the possibilities of Reznor heating solutions. They are designed for inclusion in an air handling unit (AHU) to provide a gas fired heat exchanger section or for installation in ductwork systems. They are also suitable for replacing steam and hot water coils in existing units and plenum systems, thereby enabling changeover from central boiler plant to decentralised gas fired systems. RHC 4000 The RHC 4000 range extends from 18 to 200 kw output RHC 8000 With a choice of 15 outputs (30 to 300 kw) units can be mounted in multiples of up to three in series and two high, or side by side, enabling heat outputs up to 1200 kw. Both types of unit are suitable for either indoor (DJL models) or outdoor (RJL models) applications. RHCE 8000 The newest addition is the RHCE range, the high efficiency condensing version that comes in 56, 82 and 106 kw output capacities. Benefits High efficiency units: RHC: 91%+, RHCE: 101%+ * qualify for Enhanced Capital Allowances in the UK. Application flexibility: Most units can accomodate both vertical and horizontal airflows. Choice of controls: Close temperature control - On/Off High/Low or modulating. Longer life: Heat exhanger tubes are expanded into a collection box, eliminating welds. Furthermore they are available with a choice of stainless or aluminised steel tubes. Low cost: Simple installation reduces costs. Optimum choice: The different tube lenghts available in both the RHC 4000 and RHC 8000 units offers the designer a wide choice to suit the air handling unit profile. Air Flow Directions Where optional diffuser plate is used, it must be fitted on the air inlet *Efficiency net calorific value 1

RHC gas fired heating coils EXAMPLES Optional Control Vestibules DJL MODEL Indoors application RJL MODEL Outdoors application Multiple Units Monobloc Double Unit Range capability can be increased by Mounting units two high or side by side. Monobloc Triple Unit 2

RHC 4000 : 4018.05 4036.08 RHC 4000 Gas Fired Heating Coils Model 4018.05 4024.05 4030.06 4036.08 Nominal heat output kw 18 24 30 36 Natural gas consumption 1 m³/h 2,10 2,79 3,49 4,20 LPG consumption 1 kg/h 1,57 2,10 2,61 3,14 Gas connection 2 Rc Flue diameter (RJL) mm Flue diameter (DJL) mm 100 130 Combustion air inlet (DJL) mm 100 130 Electrical consumption (230V 1Ph 50Hz) kw Net weight kg 30 31 33 52 RHC 4000 Dimension Data Model 4018.05 4024.05 4030.06 4036.08 Height A mm 458 559 559 837 Width B mm 547 677 677 677 Depth C mm 590 648 648 648 Pressure Drop Data - Standard Airflow Model 4018.05 4024.05 4030.06 4036.08 Minimum airflow m³/h 2270 2880 3290 5281 Pressure drop minimum airflow Pa 15 20 15 25 3

RHC gas fired heating coils RHC 4000 : 4050.06 4100.12 RHC 4000 Gas Fired Heating Coils Model 4050.06 4060.07 4075.09 4100.12 Nominal heat output kw 51 61 75 100 Natural gas consumption 1 m³/h 5,92 7,12 8,73 11,45 LPG consumption 1 kg/h 4,43 5,25 6,61 8,57 Gas connection 2 Rc 3/4 Flue diameter (RJL) mm 100 Flue diameter (DJL) mm 130 Combustion air inlet (DJL) mm 130 Electrical consumption (230V 1Ph 50Hz) kw 0,153 Net weight kg 90 100 120 149 RHC 4000 Dimension Data Model 4050.06 4060.07 4075.09 4100.12 Height A mm 531 601 741 950 Pressure Drop Data - Single Module Model 4050.06 4060.07 4075.09 4100.12 Minimum airflow m³/h 3900 4700 5700 7500 Pressure drop minimum airflow Pa 40 40 37 40 Pressure Drop Data - Twin Module Model 4050.06 4060.07 4075.09 4100.12 Minimum airflow m³/h 5950 7150 8800 11700 Pressure drop minimum airflow Pa 150 150 150 156 4

RHC 4000 : 4110M.13 4200M.24 RHC 4000 Gas Fired Heating Coils Model 4110M.13 4125M.15 4150M.18 4175M.21 4200M.24 Nominal heat output kw 112 126 151 175 199 Natural gas consumption 1 m³/h 13,02 14,63 17,44 20,19 22,94 LPG consumption 1 kg/h 9,61 10,79 12,85 14,89 16,91 Gas connection 2 Rc 1 1/4 Flue diameter (RJL) mm 130 Flue diameter (DJL) mm 130 Combustion air inlet (DJL) mm 130 Electrical consumption (230V 1Ph 50Hz) kw 0,282 0,655 Net weight kg 200 220 250 279 313 RHC 4000 Dimension Data Model 4110M.13 4125M.15 4150M.18 4175M.21 4200M.24 Height A mm 1132 1272 1481 1691 1900 Pressure Drop Data - Single Module Model 4110M.13 4125M.15 4150M.18 4175M.21 4200M.24 Minimum airflow m³/h 8600 9600 12300 14100 16300 Pressure drop minimum airflow Pa 70 68 44 43 44 Pressure Drop Data - Twin Module Model 4110M.13 4125M.15 4150M.18 4175M.21 4200M.24 Minimum airflow m³/h 13600 15600 17500 20600 23300 Pressure drop minimum airflow Pa 352 359 178 181 165 5

RHC gas fired heating coils RHC 8000 : 8030.06 8090.18 RHC 8000 Gas Fired Heating Coils Model 8030.06 8045.09 8060.12 8075.15 8090.18 Nominal heat output kw 30 46 61 75 90 Natural gas consumption 1 m³/h 3,53 5,34 7,12 8,72 10,48 LPG consumption 1 kg/h 2,64 4,00 5,33 6,43 7,72 Gas connection 2 Rc 3/4 Flue diameter (RJL) mm 100 130 Flue diameter (DJL) mm 100 130 Combustion air inlet (DJL) mm 100 130 Electrical consumption (230V 1Ph 50Hz) kw 0,153 Net weight kg 60 87 120 140 160 RHC 8000 Dimension Data Model 8030.06 8045.09 8060.12 8075.15 8090.18 Height A mm 531 741 950 1160 1369 Pressure Drop Data - Single Module Model 8030.06 8045.09 8060.12 8075.15 8090.18 Minimum airflow with optional diffuser plate m³/h 3750 5650 7500 9300 11200 Pressure drop with diffuser plate Pa 85 90 90 85 85 Minimum airflow standard unit m³/h 4400 6600 8750 11900 14300 Pressure drop minimum airflow Pa 40 40 40 50 50 Pressure Drop Data - Twin Module Model 8030.06 8045.09 8060.12 8075.15 8090.18 Minimum airflow with optional diffuser plate m³/h 3750 5650 7500 9300 11200 Pressure drop with diffuser plate Pa 90 100 100 95 95 Minimum airflow standard unit m³/h 4400 6600 8750 11900 14300 Pressure drop minimum airflow Pa 70 75 75 80 80 Pressure Drop Data - Triple Module Model 8030.06 8045.09 8060.12 8075.15 8090.18 Minimum airflow standard unit m³/h 5250 7850 10500 13000 15800 Pressure drop minimum airflow Pa 135 140 145 135 140 6

RHC 8000 : 8050.06 8200M.24 RHC 8000 Gas Fired Heating Coils Model 8050.06 8075.09 8100.12 8125M.15 8150M.18 8175M.21 8200M.24 Nominal heat output kw 51 76 100 126 150 174 200 Natural gas consumption 1 m³/h 5,92 8,73 11,45 14,63 17,44 20,19 23,28 LPG consumption 1 kg/h 4,43 6,61 8,57 10,78 12,85 14,88 17,16 Gas connection 2 Rc 3/4 1 1/4 Flue diameter (RJL) mm 100 130 Flue diameter (DJL) mm 130 Combustion air inlet (DJL) mm 130 Electrical consumption (230V 1Ph 50Hz) kw 0,153 0,282 0,656 Net weight kg 80 110 145 200 230 265 305 RHC 8000 Dimension Data Model 8050.06 8075.09 8100.12 8125M.15 8150M.18 8175M.21 8200M.24 Height A mm 531 741 950 1272 1481 1691 1900 Depth B mm 400 400 400 400 400 400 530 Pressure Drop Data - Single Module Model 8050.06 8075.09 8100.12 8125M.15 8150M.18 8175M.21 8200M.24 Minimum airflow with optional diffuser plate m³/h 6200 9300 12400 15600 18200 20100 23300 Pressure drop with diffuser plate Pa 100 115 115 110 110 85 80 Minimum airflow standard unit m³/h 7150 10790 14300 18000 21000 21500 24000 Pressure drop minimum airflow Pa 50 50 50 50 50 40 40 Pressure Drop Data - Twin Module Model 8050.06 8075.09 8100.12 8125M.15 8150M.18 8175M.21 8200M.24 Minimum airflow with optional diffuser plate m³/h 6200 9300 12400 15600 18200 20100 23300 Pressure drop with diffuser plate Pa 110 120 120 120 120 125 145 Minimum airflow standard unit m³/h 7150 10750 14300 18000 21000 21500 24000 Pressure drop minimum airflow Pa 85 95 90 95 95 70 65 Pressure Drop Data - Triple Module Model 8050.06 8075.09 8100.12 8125M.15 8150M.18 8175M.21 8200M.24 Minimum airflow standard unit m³/h 8750 13000 17000 22000 26000 30000 35000 Pressure drop minimum airflow Pa 170 185 180 180 185 185 190 7

RHC gas fired heating coils RHC 8000 : 8225M.18 8300M.24 RHC 8000 Gas Fired Heating Coils Model 8225M.18 8250M.20 8275M.22 8300M.24 Nominal heat output kw 222 247 272 296 Natural gas consumption 1 m³/h 25,78 28,66 31,53 34,41 LPG consumption 1 kg/h 19,00 21,12 23,24 25,36 Gas connection 2 Rc 1 1/4 Flue diameter (RJL) mm 130 Flue diameter (DJL) mm 150 Combustion air inlet (DJL) mm 150 Electrical consumption (230V 1Ph 50Hz) kw 0,84 Net weight kg 487 501 516 530 RHC 8000 Dimension Data 600 A 2435 550 Model 8225M.18 8250M.20 8275M.22 8300M.24 Height A mm 1917 2083 2249 2415 Pressure Drop Data - Single Module Model 8225M.18 8250M.20 8275M.22 8300M.24 Min airflow with optional diffuser plate m³/h 22800 25200 27600 29700 Pressure drop with diffuser plate Pa 35 35 35 35 Minimum airflow standard unit m³/h 33600 37200 40800 43800 Pressure drop at minimum air flow Pa 40 40 40 40 Pressure Drop Data - Twin Module Model 8225M.18 8250M.20 8275M.22 8300M.24 Min airflow with optional diffuser plate m³/h 29000 32200 35400 38700 Pressure drop with diffuser plate Pa 65 65 80 80 Minimum airflow standard unit m 3 /h 33600 37200 40800 43800 Pressure drop at minimum air flow Pa 65 70 85 85 Pressure Drop Data - Triple Module Model 8225M.18 8250M.20 8275M.22 8300M.24 Minimum airflow standard unit m 3 /h 39500 44300 47700 52000 Pressure drop at minimum air flow Pa 154 159 150 155 8

RHCE condensing heating coils RHCE 8000 : 8055.06 8110.12 RHCE 8000 condensing Gas Fired Heating Coils Model 8055.06 8080.09 8110.12 Nominal heat output kw 56 82 106 Natural gas consumption 1 m³/h 5,91 8,72 11,15 LPG consumption 1 kg/h 4,36 6,43 8,22 Gas connection 2 Rc 3/4 Flue diameter (RJL) mm 100 Flue diameter (DJL) mm 130 Combustion air inlet (DJL) mm 130 Electrical consumption (230V 1Ph 50Hz) kw 0,285 0,285 0,285 Net weight kg 175 225 275 RHCE 8000 Dimension Data Model 8055.06 8080.09 8110.12 Height A 3 mm 531 741 950 Depth B 3 mm 800 800 800 Pressure Drop Data - Single Module Model 8055.06 8080.09 8110.12 Minimum airflow with optional diffuser plate m³/h 6200 9300 12400 Pressure drop with diffuser plate Pa 75 99 101 RHCE: condensing heating coil The RHCE is the latest evolution of the RHC. The RHCE has additional passes in its heat exchanger tubes, which enables it to attain a higher efficiency by condensation. Through condensation, more heat is extracted out of the flue gases. RHCE units can be combined with regular RHC units of the 8000-series. 3 Height and depth of single RHCE unit only; RHCE units are often combined with regular RHC units of the 8000 series. 9

FLUE ARRANGEMENTS FOR RHC J&M Sabbestraat 130/A000 B-8930 Menen België Tel. +32(0) 56 52 95 11 Fax. +32(0) 56 52 95 33 reznor.europe@nordyne.com www.reznor.eu Company Standards and Services: All Reznor products are tested and approved to CE standards. Reznor Europe nv is assessed to EN ISO 9001 Quality Assurance. Reznor offers a service to its customers; including budget schemes, on site technical support and a comprehensive after-sales package. Reznor reserves the right to change specifications without prior notice. 1405_RHC_RHCE_EN