Cata-Dyne LH Line Heater & Micro Line Heater

Similar documents
Process Systems. Line Heaters. Heat Transfer Systems. Specialized Water Treatment Systems. Fuel Gas Conditioning Systems.

Explosion-Proof Gas Catalytic Heaters. Product Catalog

Nuclear Electric Heating

Protection Grilles. N Note Cannot be used with MKII units. Not available for all sizes.

Accessories. Safety Shut-off Valves. Certifications. Accessories. ASV375NT Safety Shut-off Valve. Combination Gas Control/Valve

DIVISION FINNED WATER-TUBE BOILERS

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

DIVISION FINNED WATER-TUBE BOILERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

DIVISION FINNED WATER-TUBE BOILERS

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

WATER-TUBE POOL HEATERS

1.0 special notices 2.0 CERTIFICATION

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

Oil and Gas Heaters ZICOM EQUIPMENT PTE LTD

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

C1050ES Tankless Water Heater

WATER-TUBE POOL HEATERS

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

DESIGN PHILOSOPHY. Indirect bath heaters have a wide variety of successful applications in the oil and gas

Infrared Gas Catalytic Heaters Enclosures Line Heaters Systems and Accessories

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

CLE SERIES Fluid heating for emergency eyewash stations

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

MECHANICAL VENTING VERSATILITY

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

C1210ES Tankless Water Heater

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

ULTRA-SAFE Explosion-proof Duct Heaters

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Williams & Davis Boilers

Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

940ES Tankless Water Heater

FINNED WATER-TUBE POOL HEATERS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

FINNED WATER-TUBE POOL HEATERS

"HC" AIRFLO. In-duct firing line burner

Concrete Applications

Williams & Davis Boilers

TABLE OF CONTENTS BRADFORD WHITE BOILERS

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Industrial Applications

940ES Tankless Water Heater

Commercial Gas Water Heaters

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

Tankless Condensing High Efficiency Water Heaters

Winter Railway Switch Protection: Horizontal Air Curtains HAC & QHAC Series. Standard

PART NO. COMBUSTION AIR CAP

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Direct Fired Heater Model AD Specification

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

INDUSTRIAL WATERTUBE BOILERS

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

ULTRA-SAFE Explosion-proof Duct Heaters

Residential/Commercial Gas Condensing Tankless Models

DATE PRODUCT WAS INTRODUCED TO THE CANADIAN MARKET: September 2018

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Project Name: Location: Engineer: Contractor: I. GENERAL

The WCGH High Efficiency Commercial Water Heater with Storage Tank

Residential Gas Tankless Water Heater

GB Condensing Gas Boiler

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

Greater temperature control

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

INFRARED RADIANT HEATERS

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

TANKLESS PRODUCT GUIDE

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

ProRadiant Controls, Valves and Actuators

High Efficiency Commercial Gas Water Heaters

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Boiler Technical Specifications (2013)

HIGH EFFICIENCY COMMERCIAL BOILERS

AHRI Certified up to. 95% efficiency P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Transcription:

Cata-Dyne LH Line Heater & Micro Line Heater

The Cata-Dyne LH Line Heater The Cata-Dyne LH Line Heater is an advanced pipeline heating system. It prevents equipment freezing and possible hydrate formation during pressure reduction at natural gas regulating sites. The LH Line Heater heats the gas stream using infrared radiant heat transfer, eliminating the use of burners, glycol fluid and high maintenance heat exchange systems. It is also used to condition fuel gas for natural gas fired turbines or engines, and for heating gas and diluent streams in a variety of process applications. Custom engineered units for non-standard applications are available. The Cata-Dyne LH Line Heater s use of direct infrared heat transfer eliminates the need for traditional gas fired glycol bath systems. The elimination of glycol based heat transfer systems results in a more environmentally favorable installation. High field maintenance and operating costs are all eliminated by the Cata-Dyne LH Line Heater. The heart of each LH Line Heater is the industry standard Cata-Dyne WX Gas Catalytic Heater. The Cata-Dyne WX Heater brings its trademark quality, durability and performance efficiency to provide the most consistently reliable and efficient low emission radiant heat source available. The Cata-Dyne WX Heater conforms to the ANSI Z83.20a-2010/CSA 2.34a-2010 standard for Gas-Fired Low Intensity Heaters. The LH Line Heater is available in five standard sizes ranging from 40,000 to 160,000 Btu input (see Table 1). The Cata-Dyne LH Line Heater is designed and built for Class I, Division 1 or 2, Group D hazardous locations. This allows the LH Line Heater to be installed directly in classified areas for a compact installation compared to traditional fired glycol water bath systems.

Line Heater Features Infrared radiant energy provided by the silent Cata-Dyne WX Gas Catalytic Heater is NOx free providing the cleanest and quietest heating system available. The flanged multi-pass coil heat exchanger is designed and built to the ASME B31.3 Code for Process Piping with Canadian Registration Number (CRN). Enclosures feature galvanized steel structures with stainless-steel cladding, limiting corrosion and maintenance. Control options from manual stop/start with and without temperature control to remote start/stop and automated feedback pneumatic or electric temperature control. Automatic units feature engineered control panels with PLC control systems. Infrared heat is accurately controlled to meet process temperature requirements while economizing operating costs. Standard high temperature shutdowns, optional low flow shutdowns available. Fuel gas system designed and built in accordance with CSA/Can B149.1 and NFPA 54. Electrical system designed and built in accordance with CSA/Can C22.2 and NEC (NFPA 70). Catalytic heaters conform to ANSI Z83.20a-2010/ CSA 2.34a-2010 standard for Gas-Fired Low Intensity Heaters and are CSA and FM certified for use in Class I, Division 1 or 2, Group D hazardous locations. Hybrid Design Capabilities Only CCI Thermal offers the optional Catalytic/Electric Hybrid Line Heater. A secondary electric gas circulation heater is used to augment the capabilities of the base catalytic line heater. The hybrid design provides enhanced responsiveness to gas flow transients and deeper turn-down capabilities. Applications Superior Technology Cata-Dyne Line Heaters are used for a variety of applications in the oil & gas, pipeline, midstream, gas distribution, and power generation industries. Common applications include: Heating high pressure natural gas prior to pressure reduction to prevent equipment freezing and the formation of hydrates. Conditioning fuel gas for natural gas fired turbines and engines. Heating of gas and diluent streams in a variety of process applications. The industry s cleanest operating catalytic heater. The catalytic oxidation process is NOx free, producing only CO2 and water as combustion byproducts. Maximized heat transfer surface area due to minimal coil spacing and the maximum number of series passes possible in a fixed vertical space. Vertically stacked heaters are the ideal configuration for effective thermal draft ventilation of heater faces and removal of CO2 and water vapour byproduct of the catalytic oxidation process.

External Enclosures Cata-DyneTM WX Gas Catalytic Heater Infrared radiant energy provided by the silent Cata-Dyne WX Gas Catalytic Heater is NOx free providing the cleanest and quietest heating system available. Enclosures feature galvanized steel structures with stainless-steel cladding, limiting corrosion and maintenance. Cata-Dyne Explosion-proof Catalytic Heaters conform to ANSI Z83.20a-2010/CSA 2.34a-2010 standard for Gas-Fired Low Intensity Heaters and are CSA and FM certified for use in Class I, Division 1 or 2, Group D hazardous locations. Vertically positioned heaters produce the most effective thermal draft, ventilation of heater faces and removal of water vapour created by the catalytic oxidation process. Heat Exchanger Coil The flanged multi-pass coil heat exchanger is designed and built to the ASME B31.3 Code for Process Piping with Canadian Registration Number. Available ANSI 600 and 900 flange ratings. High velocity turbulent flow through uniform diameter passage. Maximized heat transfer surface area due to minimal coil spacing and increased number of series passes possible in a fixed vertical space. Electrical System Electrical system designed and built in accordance with CSA/Can C22.2 and NEC (NFPA 70). Available DC or AC startup.

High Temperature Shutdowns Standard high temperature shutdowns, optional low flow shutdowns available. Control Options Control options from manual stop/start with and without temperature control to remote start/stop and automated feedback pneumatic or electric temperature control. Automatic units feature engineered control panels with PLC control systems. Fuel System Design Fuel gas system designed and built in accordance with CSA/Can B149.1 and NFPA 54. Integral Flo-Dri fuel gas filter ensures high quality fuel gas.

EXHAUST LOUVRE TYP. BOTH SIDES GAS MANIFOLD (SHOWN WITHOUT GAUGES) CATA-DYNETM PRE-HEAT SELECTION SWITCH C/W ACCESS DOOR GAS TRAIN COMPONENTS ACCESS DOOR CATA-DYNETM WX HEATER POWER SUPPLY TERMINAL BOX HEAT TRANSFER COIL INLET TEMPERATURE GAUGE OUTLET 1/2 NPT FUEL GAS INLET FRONT VIEW SIDE VIEW TABLE 1: Cata-DyneTM LH Series Standard Model Sizing Model Heater Input (Btu/hr) Minimum Maximum LH-40 10,000 40,000 LH-60 15,000 60,000 LH-80 20,000 80,000 LH-100 25,000 100,000 LH-160 40,000 160,000 External Dimensions in (mm) Length x Width x Height 56 x 48 x 84 (1420 x 1219 x 2130) 78 x 68 x 90 (1980 x 1725 x 2286) Note: 1. Custom designs and Btu ratings are available upon request. 2. Heater output between minimum and maximum values is manually selected on manual and sequential models. 3. Automatic zone control is only available with the automatic model. Prefix Model Start-up Type LH 40 M 40 40,000 Btu/hr M Manual 60 60,000 Btu/hr S Sequential 80 80,000 Btu/hr A Automatic* 100 100,000 Btu/hr 160 160,000 Btu/hr *Engineered option Model Coding Temp. Control Start-up Voltage Flange Size (in) Flange Rating (ANSI) NT 12 1 600 NT Fixed heat output, outlet temperature not controlled T* Variable heat output, low/high, outlet temperature controlled *Variable control from 40% to 100% of heater output. 12 VDC 1 600 120 2 900 208 3 240 480 600 *Custom on LH-160

The Cata-Dyne Micro Line Heater The Cata-Dyne Micro Line Heater prevents equipment freezing and possible hydrate formation during pressure reduction at natural gas regulating sites. The Micro Line Heater heats the gas stream using infrared radiant heat transfer from Cata-Dyne WX heaters. The Cata-Dyne Micro Line Heater s use of direct infrared heat transfer results in an environmentally favorable installation free of burners, heat transfer fluids and noise. High field maintenance and operating costs are all eliminated by the Cata-Dyne Micro Line Heater. Custom engineered units for non-standard applications are available. Features Benefits Allows for installation in existing facility by mounting onto 1 and 2 piping reducing installation costs Certified for use in Class I, Division 1 & 2, Group D locations Conforms to CSA B149.1 & B149.3 Meets ANSI Z83.20a-2010/CSA 2.34a-2010 Sizes available from 10,000 to 40,000 Btu input Handles between 40 to 130 Mcf/D of Natural Gas with pressure reductions as high as 1200 psi down to 50 psi without freeze-offs Simple thermostat controls allowing for easy adjustment Ideal for lower flow conditions where Glycol Water Bath systems are not practical Approximately ¼ of the cost of standard ethylene glycol water bath system No ethylene glycol Simple start-up allows for system to be shut-down and started as required during low/zero flow conditions Reduced maintenance 28 1/8 20 Standard Heater Sizes 27 5/8 27 28 1/8 20 28 5/8 27 5/8 27 28 1/8 24 1/16 20 24 1/4 28 5/8 27 5/8 28 6 x 24 Single Coil 27 12 x 24 24 x 24 Double Coil Quad Coil 24 1/16 24 1/4 24

24 1/4 8 1500 W. Campus Drive Toll Free: 1.855.244.3128