Laboratory Refrigerator/Deep Freezer TC 802

Similar documents
Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Chromatographic Air circulated Refrigerator, two-door TC 603

Chromatographic Air circulated Refrigerator, two-door TC 603

Constant climate chambers

Constant climate chambers

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Constant climate chambers

DOUBLE DOOR FREEZER.

ULTRA.GUARD ultra low temperature freezer

REFRIGERATOR M E D I C A L.

Constant climate chamber with humidity

Constant climate chamber with ICH-compliant illumination

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Internet. Climate rating definitions. Customer service.

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

PR / MP I Laboratory / Medicine

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Multi-Lab REFRIGERATORS Frigidere medicale

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

Platelet bags constant shaking for long periods of time.

Stability Chambers & Rooms

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Laboratory Refrigerators and Freezers

Constant climate chambers

edition version 1.1 Green ICE KW Antibacteria

MEDICAL REFRIGERATORS

Walk in Freezer. Comfortable work environment

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Refrigerated Incubators / Environmental Testing Chambers

STABILITY ICH. ICH Stability Tests

Laboratory Refrigerators and Freezers. Also with explosion-proof interior

FITOCLIMA 600 & 1200 STABILITY

Refrigerators and freezers Research and laboratory 2018

Long Term Storage Cabinet

Laboratory refrigerators and freezers

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Laboratory Refrigerators and Freezers. Also with explosion-proof interior intrinsically safe, independently tested as well as certified.

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Laboratory thermostatic chambers

Laboratory Refrigerators and Freezers

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Environmental simulation chamber for complex alternating climate profiles

REAL TIME LABORATORY MONITORING SYSTEM

Commodity Description

FITOCLIMA 600 & 1200 STABILITY

Constant climate chambers

Measuring Recording Online Monitoring Regulation Alarming

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

MICRO CLIMA-SERIES TM (COOLED) INCUBATORS AND WALLS

Laboratory refrigerators

PT E SERIES ACTIVE REFRIGERATORS ZANUSSI RANGE COMPOSITION FUNCTIONAL AND CONSTRUCTION FEATURES

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

Protection, safety, reliability. And more.

Air & Water Heat Pump R832

BIOMEDICAL REFRIGERATORS

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Cold chain monitoring technologies. Facility monitoring

Stability & Shelf Life

TEMPERATURE SHOCK TEST CHAMBERS

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Refrigerators and freezers Pharmacy and laboratory 2016

Blood bank refrigerators

Constant climate chambers

Biomedical Freezer 37 38

Life Science Business Unit. AS - Biomedical Equipment Division. Prefabricated cold, thermostatic and climatic chamber/pe Series

Medical Refrigerators

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

FITOCLIMA 600 & 1200 PHARMA

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

L E C M E D I C A L LABORATORY FREEZERS

Model KBF 240 Constant climate chambers with large temperature / humidity range

The new generation of cold room solutions. CAMAlarm Alarm Alarm

Concise catalogue Water-Industry

Benefit Cabinets. Performance. Efficiency

Benefit Cabinets. Performance. Efficiency

Plant growth chambers

New Generation KBF 240 series

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

Heated and Refrigerated Incubators

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

VIBRA-series: VIBRA, VIBRA +

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Drying and heating chambers

Blood Bank Refrigerators

Constant climate chambers

Remote Conditioners. RC-Series. ZPRC Series

160 Line. 1 Door Undercounter Refrigerator (+2/+10) - UK Plug. 160 Line

Transcription:

External Dimension: B = 600 mm D = 615 mm H = 2000 mm Inside Dimension: Useful space on top Useful space at the bottom B = 440 mm B = 431 mm D = 435 mm D = 435 mm H = 1105 mm H = 597 mm Capacity: 254 l 107 l Temperature range: 3 C to 16 C -9 C to -30 C Housing galvanized sheet steel with white coating. 2 isolated doors supplied as standard with right hand hinge (reversible), Including 2 pcs. door locks. Grease resistant magnetic seal. Interior space of high quality plastic. Cleaning friendly by rounded corners, slippery surface in the interior, meets highest hygiene requirements Isolation Polyurethane, free of CFCS Circulating air cooling in the refrigeration unit for rapid and uniform temperature control, reducing temperature gradients to a minimum. When the door is "open" the circulating fan is switched off automatically by a micro switch in order to prevent warmer ambient air being drawn in. Interior fittings On top: 3 pcs. glass shelves (440 x 420 mm) max. load per shelf: 40 kg At the bottom: Plastic drawers, white with transparent front with two permanently mounted contact evaporator plates 2 pcs. (425x395x180 mm) 1 pcs. (425x225x190 mm) max. load per drawer: 24 kg technische Änderungen vorbehalten Seite 1 von 5

Control system located above door. 2 pcs. High quality electronic temperature controller. Actual and set value display digital. Actual value permanently readable Set value digital adjustable by switch Working range from 3 C to 16 (+/- 2 C) and -9 C to -30 C (+/-3,5 C) - Temperature differences are displayed visually and acoustically, - Door open Alarm - Potential free alarm output for remote transmission - Power failure alarm when mains power returns (optical) - RS 485 interface - Min/max temperature Product protection against low temperatures. By dropping below 2 C, the cooling machine will automatically switched off Refrigerating unit 2 separate Refrigerating unit fully hermetically sealed, forced ventilation, fitted on vibration - absorbing mounts (ambient temperature max. 32 C), low noise (52 dba/1m), energy saving compressor with high quality vaporisation system. Refrigerant: R600a Defrost Automatic defrost in the refrigeration unit, manual defrost in the freezer unit Electrical dates Power supply Absorption Energy consumption Power cable 230 V/50 Hz / single-phase 1,5 A 1,8 KW (24 Std.) 1,5 m with Schuko plug Packing details (palletized) Dimensions: approx. 70x70x210 cm Net weight: approx. 85 kg Gross weight: approx. 91 kg Country of Origin: European Community Customs clearance code: 8418 1080 Special Equipment and Accessories: Cable port for example to create access for operator measurement lines, etc. Optional: with separate sensor kind and version as desired by the customer technische Änderungen vorbehalten Seite 2 von 5

Wireless data logger, complete For independent temperature recording consisting of: Wireless data logger, SPY RF U2 2-channel for Pt100, 4-20mA / 0-1V / contact on-off, with display measurement accuracy at 23 C: +/- 0,3 C Resolution 0,1 C Battery : Lithium Battery Recording interval: 1 sec. to 90 minutes Internal memory: 20.000 measurements Usable range: 1km LOS Communication: via radio 868 Mhz Power: 25 mw incl. 2 pcs. Sensor of stainless steel, Ø 4,0mm L=30mm Pt100 class A with plugged cable of PTFE Measurement area: -200 C +200 C Length: 3 meter Optional: 8 meter Delivery contents: wall mounting holder and plug protection Software - Basic Version for single user - Maintenance of multiple Wireless data logger - collect the recorded data of the Wireless data logger - Back up data (tamper-proof) - Prepare the data in terms of graphics or charts - Excel exportable - Maintenace of alarms via potential free contact at the Modem - or Alarmsystem (SMS, phone call, blinking light, buzzer) SPY RF USB-Modem for data transfer to the PC via USB-connector - communication with infinete numbers of Wireless data logger - remote alarm via integrated potential contact - including wall mounting holder technische Änderungen vorbehalten Seite 3 von 5

Optional: Sensor of stainless steel with ATEX Exi certification Ø 4,0mm L=30mm Pt100 class A, with plugged cable of PTFE, Measurement area: -200 C +200 C Length: 8 Meter SPY RF Relay (Repeater) - Allows the data transfer of the data logger about bigger distances - Can transfer dates of one or several SPY RF data logger - Electricity supply about power supply unit and battery in case of power failure - with 2 output ranges: 25mW to communicate with the data logger and 500mW to communicate with the modem. - Delivered with wall mounting fixture - Ambient temperature: from -10 C to +70 C SPY RF Alarm - realtime alerting - i.e. by limit exceeded or power failure - Local warning - Integrated acoustical and optical Alarm - Power supply via external power adapter and spare battery in case of power failure - Button for local alarm quitt - Relais output for remote alarm) (GSM-Modem, telephone dialer) - including wall mounting holder SPY RF Telephone dialer - In the speech modus it called up to 6 different subscriber and informed them about the kind of failure - This ergonomically linguistic aid provides high operational ease. - requires an analogue phone line - Individual adjustment of identification, alarms and alarm quitt - requires an external power supply (included) GSM-Modem I for switch contact For use with: Software - Basic Version and SPY RF USB-Modem, or SPY RF Alarm - Enables to send SMS messages - Modem registered also power failure and send SMS immediately. technische Änderungen vorbehalten Seite 4 von 5

Qualifications DQ (Design Qualification) Definition: Documented proof that the quality-related, GMP-related requirements has been adequately addressed in the design of equipment, including buildings, premises and auxiliary equipment The user-requirement profiles (specifications) are documented and confirmed by us. On request, a specification can be created by us. IQ (Installation Qualification) Definition: Documented proof that critical equipment and systems have been delivered and installed in accordance with the set requirements and government regulations. The IQ documentation is worked out by us especially for the delivered machine and is made available to you. The IQ documentation has to be carried out by the customer itself. OQ (Operational Qualification) Definition: Documented proof that critical equipment and systems in accordance with the set requirements in the whole operating range are working as intended in accordance with predetermined limits. The OQ documentation is worked out by us especially for the delivered machine and is made available to you. The OQ documentation has to be carried out by the customer itself. CQ (Calibration Qualification) Definition: Documented proof that critical measuring equipment in the intended range in accordance with predetermined tolerances operate reliably under current operating conditions Checking the temperature in the cabinet 1 Temperature on 3 different measuring points (measured with calibrated PT 100 sensor) evenly located on the shelves. Inspection time 6 hours, open door after that of 30 seconds. The inside temperature of the cabinet must have been stabilized itself within 1 hour on the set point temperature. The measurements are carried out in the empty state. The temperature measures are carried out in our company, represented graphically and provided to you. The values may not dropping below or above the tolerances given by us. (Additional measuring points on request) PQ (Performance-Qualification) Definition: Documented proof that critical equipment and systems in accordance with the set requirements in the whole workspace under current working conditions (with product) provide the requested services The calibration described above is carried out under real conditions on site. The values may not dropping below or above the tolerances given by us. technische Änderungen vorbehalten Seite 5 von 5