Heated and Refrigerated Incubators

Similar documents
Refrigerated Incubators / Environmental Testing Chambers

Ultra-Low Temperature Chest Freezers

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

GENERAL PURPOSE LABORATORY GRADE REFRIGERATORS AND FREEZERS. Versatile 4 C and -20 C preservation for laboratory research and life science materials.

Professional CO2 and O2/CO2 Incubators

Refrigerators. Upright Blood Bank. i.series Horizon Series

Digital incubating/ refrigerating benchtop shakers

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Laboratory & Pharmacy Refrigerators

Operation Manual. (Version 1.5.1)

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

1.1 Setup Installation

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Freezers. Laboratory & Plasma. i.series Horizon Series

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Cell Culture CO2 Incubators

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

TCC-34. Features: TISSUE CULTURE

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

A look into our complete product collection.

TCR. Features: TISSUE CULTURE

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

Laboratory refrigerators and freezers

Operation Manual (Version 1.5.1)

Platelet Storage. i.series Horizon Series

Controlled Environment Equipment Solutions for the Lab

Environmental Chambers

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

A look into our complete product collection. powered by

Ultra-Low and Cryogenic Solution

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

Laboratory thermostatic chambers

Operating Instructions

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Platelet Storage. i.series Horizon Series

VWR symphony CO 2 INCUBATORS

Chromatographic Air circulated Refrigerator, two-door TC 603

Universal Applications

Chromatographic Air circulated Refrigerator, two-door TC 603

Ultra-Low and Cryogenic Solutions

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Advance Blood Storage system from Meditech

ENVAIR lab CO2 Incubator

SPC-56 SHORT PLANT.


Constant climate chamber with ICH-compliant illumination

TPR. Features: TALL PLANT

V.I.P. Series -86 C Ultra Low Freezers

Constant climate chambers

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Commodity Description

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

Platelet bags constant shaking for long periods of time.

Reach-In. PLanT GROWTh. Reach-In

laboratory & sterilization technology

Drying ovens, incubators, cooled incubators

Plant Growth Chamber MPGR14

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

Walk in Freezer. Comfortable work environment

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

BLOOD BANK REFRIGERATOR - BR Series

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

FITOCLIMA 600 & 1200 STABILITY

A look into our complete product collection.

Thermo Scientific Heratherm Microbiological Incubators

Plant Growth Humidity Chamber

Environmental Chambers Series: reach-in & benchtop capacities

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Introductions. Safe for cultivation

Incubators. with BioCote antimicrobial protection

Refrigerated Incubator Model and Operating Instructions

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

ENVAIR lab CO2 Tri-Gas Incubator

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

FITOCLIMA 600 & 1200 BIO

Serie V.I.P. Congelatori -86 C F

Constant climate chambers

Thermo Scientific Forma Environmental Chambers. Controlled Temperature Storage Solutions

Environmental Chambers

Slimline. Laboratory refrigerators and freezers

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Transcription:

Heated and Refrigerated Incubators MIR-162-PA MIR-262-PA MIR-154-PA MIR- 254-PA MIR-554-PA us.panasonic-healthcare.com powered by TM

Heated and Refrigerated Incubators Panasonic MIR series incubators are designed for general laboratory applications requiring fixed setpoint or cycling temperature control. A selection of five cabinet sizes offers programmed operation and integrated alarms for a wide temperature range. Heated and Refrigerated Incubators MODEL NUMBER VOLUME (CU.FT.) EXTERIOR DIMENSIONS (W X F-B X H) HEATED REFRIGERATED PROGRAMMABLE TEMPERATURE VOLTAGE, POWER CONNECTION MIR-162-PA 3.3 93 L 22.8" x 23.4" x 32.3" 580 x 595 x 820 mm yes 5ºC above ambient to 80ºC MIR-262-PA 5.4 153 L 28.7" x 25.4" x 34.3" 730 x 645 x 870 mm yes 5ºC above ambient to 80ºC MIR-154-PA 4.3 123 L 27.6" x 22.8" x 40.1" 700 x 580 x 1018 mm yes yes - 10ºC to 60ºC 115V NEMA 5-15 MIR-254-PA 8.4 238 L 27.6" x 22.8" x 63.7" 700 x 580 x 1618 mm yes yes - 10ºC to 60ºC MIR-554-PA 14.3 406 L 31.5" x 32.8" x 71.3" 800 x 832 x 1810 mm yes yes - 10ºC to 60ºC Programmable for multifunction laboratory applications. Refrigerated Incubators, Environmental Testing Chambers The Panasonic MIR series offers accurate temperature control and uniformity in a wide range of temperatures, making them suitable for various applications. Programmable with 12 step, 10 program capability and wide temperature range that goes from -10 C up to +60 C with excellent temperature uniformity. Improved usability with modern design, improved gentle air circulation that reduces media drying and adjustable low vibration. Wide Range of Applications The MIR-154 -PA and MIR-254 -PA refrigerated incubators are ideal in testing applications such as: Industrial testing in the electrical, machinery, textiles industries Chemical testing e.g., storage, stability, acid/alkali, durability Food industry for packaging, quality control and stability Testing for waste water, BOD, soil testing Microorganism culturing Germination experiments Programmable MIR-554-PA Numeric direct keyed input Memory of operation start date and hour with delay start timer Either clock mode or count down mode can be used for program setting MIR-262-PA

Flexibility The Panasonic MIR series offers accurate temperature control and uniformity in a wide range of temperatures, making them suitable for various applications. The MIR-154-PA and MPR-254-PA are programmable with 12 step, 10 program capability Wide temperature range from -10 C to +80 C Excellent temperature uniformity ON-OFF control of chamber lighting controlled by programming Improved Usability Gentle air circulation that reduces media drying Adjustable low vibration for sensitive materials testing Full alarm package Energy Savings In addition to a microprocessor-controlled high efficient heater output and compressor ON/OFF, a renewal control program and low heatemission inner chamber fan are newly adopted that allow high-energy saving operation over a wider range of ambient environments. LCD Controller The LCD Controller improves user interface for better programming and control. The controller features a pop up menu that can display: Current conditions (temperature, date, time (12 hour or 24 hour selectable) Alarm condition Door Openings Light status Various settings of each program (12 step, 10 program, clock function and join mode) Optional wireless monitoring via LabAlert Energy Savings: In addition to a microprocessor-controlled high efficient heater output and compressor ON/OFF, a renewal control program and low-heat emission inner chamber fan are newly adopted to allow high-energy saving operation over a wider range of ambient environments. P.I.D. Controller Microprocessor-based P.I.D. (proportional, integral, derivative) control with digital input, full-function alarm and monitoring. Controls for High & Low Temp. Alarm Direct entry keypad Menu call button Program step buttons Lighting override button Graphic alpha numeric display Control for LCD Contrast Buzzer silence

Heated and Refrigerated Incubators Foamed-in-place Rigid Polyurethane Insulation CFC-free foamed-in-place polyurethane is used for the chamber due to of its high thermal retention and energy saving properties. Triple-pane Glass Observation Window plus Programmable 15W Fluorescent Lamp A highly insulated triple-pane glass observation window and 15W fluorescent lamp are provided for sample observation during experimentation. When observation is not required, an optional light shielding plate (MIR-154-PA/254-PA) can be easily attached. The MIR-554-PA has an observation door included. Automatic Setting Temperature Alarm When the chamber temperature deviates more than ±1 to ±5 C (user selectable), all digits of the digital indicator flash. Fifteen minutes later a buzzer will sound. This system also automatically allows programmed operation or setting value changes. Independent over-temperature protection provides additional backup circuit and sensor in the rare case of a temperature abnormality. Programmed memory backup allows data to be stored for up to 5 hours after a power source interruption. Auto-return mechanism returns temperature to normal indicator. Self-diagnosing troubleshooting monitor and key lock are provided. Independent Over-temperature Protection Device This incubator incorporates an excessive temperature prevention circuit that protects experimentation materials in the rare event that a temperature abnormality occurs. Isolated from the main circuit, this exclusive circuit and sensor operate even if the temperature sensor or microprocessor malfunction, activating an exclusive lamp and buzzer notification. This system turns off the heater and chamber fan motor when over temperature is detected (setting temperature range: 15 C~65 C). It turns off the compressor when under temperature is detected (setting temperature range -15 C to 20 C). Remote alarm contacts are provided for monitoring alarm from a remote location. Programmed Memory Back-up Mechanism If the power source is interrupted due to power failure or any other event, programmed data remains stored in memory semi-permanently. When the power source is restored, operation can be continued according to the predetermined program. Automatic Return Buzzer Switch After an power failure occurs, the alarm buzzer automatically switches to the ON mode, even if the operator forgets to return the alarm buzzer to the ON mode, thus ensuring safe and secure operation. Key Lock A key lock switch is provided so that settings may not be changed. Auto Return Mechanism This mechanism automatically returns the chamber temperature indicator to its normal indication when the control key is not operated for approx. 90 seconds at each setting mode. Thus, normal operation is ensured even if the operator forgets an operational procedure during setting. Trouble Monitor (Self Diagnostic Function) Should a malfunction occur, the location of the malfunction will be indicated on the alpha-numeric display, allowing quick operator response. Options Double stacking option with spacer (only for MIR-154-PA) Model # MIR- S154SB-PW Key Mounting Plate: MIR-LP-PW Lighting addition kit: MIR-L15-PW Light shading plate for glass: MIR-154BP-PW/MIR-254BP-PW Chart Recorder: MTR-C958

Operational Functions Cooled Incubators PROGRAM PROGRAM PROCESS PROGRAMMABLE 3-STEP OPERATIONAL FUNCTIONS WITH MICROCOMPUTER CONTROL Program input is simple and the steps during each operation are indicated via the LCD display. This incubator accommodates a range of diversified experimentation requirements, and is ideal for experimentation during night time or weekends, or when the experiment requires the settings to be changed.it is also ideal for microorganism culture and preservation. Constant operation mode without step operation is also available. 3 STEP REPEAT OPERATION Temperature (T1, T2, T3) and Time (H1, H2, H3) are set. Then, limited repeating operations (from 1 to 99 times) or continuously repeated operations are conducted. After a limited repeating operation has been completed, constant operating temperature T0 is retained. Application: Optimum for repeated experiments in which 3 different elemental temperatures and times are combined. 3 STEP TO CONSTANT OPERATION Temperature of T1, T2, and T3, correspond to times H1, H2, and H3, respectively. Then, constant operation temperature T0 is retained. Application: Optimum for experiments that require consistent 4-step temperature increases and decreases. 2 STEP TO REPEATING OPERATION Using a temperature T1 and T2, operation is repeatedly conducted using time H1 and H2. Application: Optimum for day and night cycle operations of plant material or quality testing for chemicals, foods and samples. 2 STEP TO CONSTANT OPERATION With a temperature of T1 and T2, operation is conducted using time H1 and H2. Then, constant operating temperature T0 is retained. 1 STEP TO CONSTANT OPERATION With a temperature of T1, operation is conducted using time H1. Then, constant operating temperature T0 is retained. Application: Optimum for automation and labor savings while performing bacteria inspection from culture to preservation, and from preservation to culture. High-precision Temperature Environment Panasonic refrigerated incubators incorporate a high precision microprocessor temperature control combined with a heater P.I.D. and compressor ON-OFF system. This system has a feed forward function that inputs the operating conditions of the compressor beforehand, ensuring accurate temperature control for the chamber. In a wide temperature range from -10 C to 60 C, the heater P.I.D. exhibits temperature fluctuation up to 0.2 C, and the Compressor ON-OFF controls precisely ±1.5 C. In addition, the fluctuation of temperature uniformity in the chamber is within ±0.5 C, allowing a full range of precise experimentation from microorganism cultures to various types of incubation and testing.

Specifications Temperature Uniformity Data MIR-162-PA MIR-262-PA Specifications Model Exterior dimensions (W (W x D x x D H) x H) mm mm (inch) (inch) Interior dimensions (W (W x D x x D H) x H) mm mm (inch) (inch) Effective capacity Exterior finish finish Interior finish finish MIR-154 700 700 x 580 x 580 x 1018 x 1018 (27.6 (27.6 x 22.8 x 22.8 x 40.1) x 40.1) 620 620 x 368 x 368 x 555 x 555 (24.4 (24.4 x 14.5 x 14.5 x 21.9) x 21.9) 123 123 (4.3 (4.3 cu.ft.) cu.ft.) MIR-254 700 700 x 580 x 580 x 1618 x 1618 (27.6 (27.6 x 22.8 x 22.8 x 63.7) x 63.7) 620 620 x 368 x 368 x 1088 x 1088 (24.4 (24.4 x 14.5 x 14.5 x 42.8) x 42.8) 238 238 (8.4 (8.4 cu.ft.) cu.ft.) Galvanised steel steel with with baked-on finish finish Stainless steel steel MIR-554 800 800 x 832 x 832 x 1810 x 1810 (31.5 (31.5 x 32.8 x 32.8 x 71.3) x 71.3) 640 640 x 550 x 550 x 1160 x 1160 (25.2 (25.2 x 21.7 x 21.7 x 45.7) x 45.7) 406 406 (14.3 (14.3 cu.ft.) cu.ft.) Galvanised steel steel with with baked-on finish, finish, Door Door Galvanised steel steel with with baked-on finish, finish, triple-pane glass glass triple-pane glass glass with with observation door door Features Advanced Design PE PE coated steel steel wire, wire, adjustable Shelves Panasonic MIR-Series incubators are recognized 3 as 3 exceptional Control 5panel 5 with touch keyboard 5 5 units Insulation suitable for a wide range of applications that require a Foamed-in-place rigid rigid polyurethane Circulation system Easy-to-read Forced air air circulation green LED display temperature range of -10 C to +50 C. Hermetic type type Compressor Stable (PID), flexible (three step programming Single Single phase, Output and 150W 150W Single Single phase, Output 250W 250W Single Single phase, Output 250W 250W Evaporator temperature range between -10 C to 50 C). Fin Fin and and Durable tube tube type, type, stainless forced forced circulation steel for interior cabinet Condenser Multi-purpose and dependable. Frequently used in food Wire Wire and and tube tube type type natural air air cooling system Precise Temperature Control Defrosting system Manual / / Automatic industry, water treatment, and microbiology. Heater Microprocessor Temperature setting Controlled indication Timer Cord Cord heater heater 141W 141W Cord Cord heater heater 218W 218W Digital Digital setting heater with with control keylock, digital digital display Cord Cord heater heater 322W 322W Microprocessor PID PID system (when (when compressor operates, ON-OFF control) The Temperature MIR-Series control incorporates an 8-bit microprocessor controller Temperature range 5 C above ambient to 80 C Temperature sensor Thermistor for heat and refrigeration control ±0.2 C. Programmable models Automatic setting temperature alarm alarm When When temperature deviates Temperature approx. 2.5 2.5 degrees, accuracy visual visual and ±0.2 and audible at +37 C alarm alarm include three-step functions useful for investigations involving Over Over temperature protection device Visual Visual and and audible alarm alarm microbiology, plant cell biology, and more. Temperature uniformity ±1 C Programmed operation 12-step repeat repeat from from 1-198 - 98 times times or or unlimited. Max. Max. 10 10 programs memorised. Temperature Allows range experiments range up to 99 hours and 59 minutes 10C 10C to to +60C +60C (Ambient temperature: +5C +5C to to +35C, +35C, No No load) load) Accessories 0.2 0.2 degrees at Heater PID PID control (SV (SV 50C, 50C, AT AT 20C, 20C, No No load) load) Temperature Desired start fluctuation time is set by an automatic start Key, 1 set 1.5 1.5 degrees at at Compressor ON-OFF control (SV (SV 5C, 5C, AT AT 20C, 20C, No No load) load) (delay function) Temperature uniformity 0.5 0.5 degrees (Setting temperature Light 37C, Shielding 37C, Ambient Plate temperature 20C, 20C, No No load) load) Total Total Information power consumption function activates buzzer when 205/235W set time is over 260/280W 380/440W Interior lamp lamp 15W 15W x 1, x 1, Fluorescent lamp lamp (Setting temperature +5C +5C to to 50C) 50C) Keeps set temperature after operation finishes Net Net weight 78kg 78kg (172.0 (172.0 lbs.) lbs.) 108kg 108kg (238.1 (238.1 lbs.) lbs.) 195kg 195kg (429.9 (429.9 lbs.) lbs.) Accessories Key Key 1 set 1 set Appearance and and specifications are are subject subject to change to change without notice. notice. Caution: SANYO guarantees the the product under under certain certain warranty conditions. SANYO in no in no way way shall shall be be responsible for for any any loss loss of of content or or damage to to content. MIR-154-PA, MIR-254-PA & MIR-554-PA Dimensions Dimensions Unit Unit : mm :: mm (inch) (inch) 700 700 (27.6) (27.6) 15 (0.6) 15 (0.6) 25 25 580 580 (22.8) (22.8) 620 620 (24.4) (24.4) (1.0) (1.0) 450 450 (17.7) (17.7) 200 200 (7.9) (7.9) 200 200 (7.9) (7.9) 80 (3.1) 80 (3.1) 100 (3.9) 100 (3.9) 420 (16.5) 420 (16.5) 918 (36.1) 1018 (40.1) 28 (1.1) 28 (1.1) 918 (36.1) 1018 (40.1) 555 (21.9) 555 (21.9) 368 368 (14.5) (14.5) 65 (2.6) 858 (33.8) 858 (33.8) 65 (2.6) 700 700 (27.6) (27.6) 620 620 (24.4) (24.4) 200 200 (7.9) (7.9) 25 25 580 580 (22.8) (22.8) 15 15 (0.6) (0.6) (1.0) (1.0) 450 450 (17.7) (17.7) 200 200 (7.9) (7.9) 150 (5.9) 150 (5.9) 800 (31.5) 1518 (59.8) 800 (31.5) 1518 (59.8) 1155 (45.5) 1155 (45.5) 28 (1.1) 28 (1.1) 100 (3.9) 100 (3.9) 260 (10.2) 260 (10.2) 368 368 (14.5) (14.5) Both temperature and time are indicated on digital displays High precision microprocessor controller with heater P.I.D. 65 (2.6) 65 (2.6) 43 (1.7) 43 (1.7) 42 (1.6) 42 (1.6) 858 (33.8) 858 (33.8) 14 14 (0.6) (0.6) 800 800 (31.5) (31.5) 640 640 (25.2) (25.2) 198 198 (7.8) (7.8) 14 14 (0.6) (0.6) 200 (7.9) 200 (7.9) 15 (0.6) 35 35 (1.4) (1.4) 15 (0.6) 800 (31.5) 410 (16.1) 1400 800 (55.1) (31.5) 410 (16.1) 1810 1400 (71.3) (55.1) 1810 (71.3) 972 972 (38.3) (38.3) 832 832 (32.8) (32.8) 755 755 (29.7) (29.7) 405 405 (15.9) (15.9) 105 105 (4.1) (4.1) 1110 (43.7) 1110 (43.7) Options MIR-154-PA MIR-254-PA MIR-554-PA Spacers for for double (mm,in) stacking: MIR-S154SB (only (only for for MIR-154) Pad Pad lock lock key key mounting plate: MIR-LP (only (only for for MIR-154, 254) 254) (mm,in) Inner Inner doors: MIR-55ID (MIR-554 only) only) *The *The chamber temperature is is limited below below +50C. +50C. (mm,in) Lighting addition kit: kit: MIR-L15 Note: Note: When When the the MIR-L15 is is installed, the the illumination lamps lamps will will automatically turn turn off off at the at the temperatures outside +2C +2C to to +50C. +50C. Light Light shielding plate plate for for glass: MIR-154BP/MIR-254BP SANYO DAQ DAQ system: MTR-5000/Ethernet (LAN) (LAN) Interface MTR-L03 or or RS232C/RS485 Interface MTR-480

MIR-162-PA & MIR-262-PA Specifications MODEL NUMBER MIR-162-PA MIR-262-PA EFFECTIVE CAPACITY EXTERIOR DIMENSIONS W X F-B X H INTERIOR DIMENSIONS W X F-B X H 3.3 cu.ft. 93 L 22.8 x 23.4 x 32.3 580 x 595 x 820 mm 17.7 x 18.1 x 17.7 450 x 460 x 450 mm 5.4 cu.ft. 153 L 28.7 x 25.4 x 34.3 730 x 645 x 870 mm 23.6 x 20.1 x 19.7 600 x 510 x 500 mm EXTERIOR FINISH Baked acrylic finish on galvanized steel Baked acrylic finish on galvanized steel INTERIOR FINISH Stainless Steel (S US-304) Stainless Steel (S US-304) DOOR Outer: Baked acrylic on galvanized steel Inner: Glass Outer: Baked acrylic on galvanized steel Inner: Glass SHELVES 2, Stainless steel, Wire 3, Stainless steel, Wire INSULATION Fiber Glass Fiber Glass CIRCULATION SYSTEM Natural Convection Natural Convection HEATER 200W, Sheathed Heater 300 W, Sheathed Heater TEMPERATURE SETTING INDICATION Digital setting with digital display Digital setting with digital display TEMPERATURE CONTROL Microprocessor P.I.D system, air-jacket construction Microprocessor PID system, air-jacket construction AUTOMATION SETTING TEMPERATURE ALARM OVER TEMPERATURE PROTECTION DEVICE When temperature deviates approx. ±2.5 C, visual and audible alarm Visual and audible alarm When temperature deviates approx. ±2.5 C, visual and audible alarm Visual and audible alarm TEMPERATURE RANGE Ambient +5 C to +80 C Ambient +5 C to +80 C TIMER Automatic timer with delay function 00:00 to 99:59 Automatic timer with delay function 00:00 to 99:59 TEMPERATURE UNIFORMITY ±1 C ±1 C POWER SOURCE / VOLTAGE 115V / 60 Hz / 1 phase 115V / 60 Hz / 1 phase POWER CONSUMPTION 200 W 300 W NET WEIGHT 97 lbs 44 kg 134 lbs 64 kg MIR-162-PA & MIR-262-PA Dimensions MIR-162-PA MIR-262-PA

Heated and Refrigerated Incubator Specifications Heated and Refrigerated Incubator Specifications MODEL NUMBER MIR-154-PA MIR-254-PA MIR-554-PA EFFECTIVE CAPACITY 4.3 cu.ft. 123 L 8.4 cu.ft. 238 L 14.3 cu.ft. 406 L EXTERIOR DIMENSIONS W X F-B X H 27.6 x 22.8 x 40.1 700 x 580 x 1018 mm 27.6 x 22.8 x 63.7 700 x 580 x 1618 mm 31.5 x 32.8 x 71.3 800 x 832 x 1810 mm INTERIOR DIMENSIONS W X F-B X H 24.4 x 15.2 x 21.9 620 x 386 x 555 mm 24.4 x 15.2 x 42.8 620 x 386 x 1088 mm 25.2 x 21.7 x 45.7 640 x 550 x 1160 mm EXTERIOR FINISH Galvanized Steel with baked on finish INTERIOR FINISH DOOR Reversible painted steel & triple pane glass with observation window Stainless Steel Reversible painted steel & triple pane glass with observation window Painted steel & triple pane glass with observation door & key SHELVES 3, PE coated steel wire, adjustable 5, PE coated steel wire, adjustable 5, PE coated steel wire, adjustable INSULATION CIRCULATION SYSTEM Foam-in-place rigid polyurethane Forced air circulation COMPRESSOR 150W, Hermetic Type 250W, Hermetic Type 250W, Hermetic Type EVAPORATOR CONDENSER DEFROSTING SYSTEM Fin and tube type, forced air circulation Wire and tube type natural air cooling system Selectable manual start or timer defrost, natural vaporisation of drain water HEATER 141W, Cord Heater 218W, Cord Heater 332W, Cord Heater TEMPERATURE SETTING INDICATION TEMPERATURE CONTROL TEMPERATURE SENSOR AUTOMATION SETTING TEMPERATURE ALARM OVER TEMPERATURE PROTECTION DEVICE PROGRAMED OPERATION Digital Setting with Digital Display Microprocessor P.I.D system, (when compressor operates, ON/OFF control) Thermistor When temperature deviates approx. ±2.5 C, visual and audible alarm Visual audible alarm 12-step repeat from 1-98 times or continuous repeat TEMPERATURE RANGE -10 C to 60 C TEMPERATURE CONTROLLABILITY TEMPERATURE UNIFORMITY POWER SOURCE: VOLTAGE ±0.2 C at heater PID control (Temperature setting 50 C, ambient temperature 20 C, no load) ±1-5 C at compressor ON/OFF control (Temperature setting 5 C, ambient temperature 20 C, no load) ±0.5 C (Temperature setting 37 C, ambient temperature 20 C, no load) 115V / 60Hz / 1 phase POWER CONSUMPTION 160 W 240 W 290 W INTERIOR LAMP NET WEIGHT 172 lbs 78 kg 15 W x 1, fluorescent lamp (setting temperature +5 C to 50 C) 238 lbs 108 kg 453 lbs 205 kg ACCESSORIES Key 1 set, Light shielding plate 1 Key 1 set, Light shielding plate 1 Key 1 set Panasonic Healthcare Corporation of North America 1300 Michael Drive, Suite A, Wood Dale, IL 60191 Toll Free USA (800) 858-8442, Fax (630) 238-0074 us.panasonic-healthcare.com Panasonic Printed in USA 05/2014 AW