Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Similar documents
Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Ruud Standard Efficiency Air Handler

Rheem High Efficiency Air Handler

Ruud Standard Efficiency Air Handler

Rheem High Efficiency Air Handler

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Rheem Standard Efficiency Air Handler

HIGH EFFICIENCY AIR HANDLER

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Ruud High Efficiency Air Handler

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

HIGH EFFICIENCY AIR HANDLER

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS AIR HANDLERS

Ruud Ultra Series EcoNet Enabled Two-Stage Variable Speed Multi- Position Gas Furances

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

INSTALLATION INSTRUCTIONS

Hydronic Air Handler Powered by Tankless Technology

Bosch BVA Series Air Handler

Rheem Classic Series Multi-position Gas Furnaces

MERIT Series R-410A - Upflow / Horizontal

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

INSTALLATION INSTRUCTIONS

MERIT Series R-410A - Upflow / Horizontal

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Prestige Series Variable Speed Heat Pumps

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Ruud Achiever Plus Series Multi-position Gas Furnaces

Rheem Classic Plus Series Multi position Gas Furnaces

INSTALLATION INSTRUCTIONS

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.


INSTALLATION INSTRUCTIONS

Hydronic Air Handler Powered by Tankless Technology

Bosch BVA Series Air Handler

FEM4X. Product Specifications FAN COILS /14/15

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

PRECISION INVERTER-DRIVEN. We Thought of Everything... And Then Some.

TECHNICAL SPECIFICATIONS B6VMMX

Rheem Prestige Series Variable Speed Air Conditioners

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

REM4P, REM4X. Product Specifications

Product Data. FH4A Fan Unit. Sizes 001 thru 004

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

Cooling/Heat Pump Convertible Air Handlers

MERIT SERIES Up Flow / Horizontal

FAN UNIT FH4A Sizes 001 thru 004

Multi-Position Gas Furnaces

Rheem Classic. Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

Ruud Achiever Plus Series Two-Stage Air Conditioners

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

WAHL A Product Specifications

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Ruud Acheiver Series Upflow Gas Furnaces

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

Hydronic Air Handler Powered by Tankless Technology

Rheem Prestige Series Variable Speed Heat Pumps

Modular Multi-position Air Handler

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

Ruud Ultra Series Variable Speed Air Conditioners

AVPTC. Air Handlers 1½ to 5 Tons

Rheem Prestige Series Variable Speed Air Conditioners

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

CB X 32 mv

13 SEER CONDENSING UNITS

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

AVPTC Multi-Position, Internal Txv

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

AVPTC. Air Handler 1½ to 5 Tons

FXM4X. Product Specifications FAN COILS FXM4X

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

Transcription:

Air Handlers Rheem High Efficiency Modulating EcoNet Enabled Air Handler RHMV- Series Constant CFM Motor (ECM) Electronic Expansion Valve (EEV) Efficiencies up to 20.5 SEER The RHMV Air Handler is part of a new line of Rheem smart heating, cooling and water heating products. Using the latest in sensor technology and a powerful EcoNet monitoring system, Rheem provides homeowners with a new level of protection, control and energy savings. Rheem smart heating, cooling and water heating products will alert the homeowner if there is ever an issue via the EcoNet Smart Thermostat and the EcoNet Mobile app.* The EcoNet Mobile App makes it easy for homeowners to manage their home comfort environment at home or on-the-go,* while enjoying the convenience and savings benefits of a highly efficient system. The RHMV features an Electronic Expansion Valve (EEV) Features a constant CFM variable speed motor (ECM) which provides enhanced SEER performance. The RHMV is rated with RA17, RA20 air conditioners and RP17, RP20 heat pumps. Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing. Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications. Factory-installed indoor coil. Sturdy cabinet construction with 1.0 inch [25.4 mm] of foil faced insulation for excellent sound and insulating characteristics. Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cul requirements for service disconnect. 1 1 /2 ton [5.3 kw] through 5 ton [17.6 kw] models are between 42 1 /2 to 57 inches [1080 to 1448 mm] tall and 22 inches [559 mm] deep. All models meet or exceed 330 to 400 CFM [156 to 189 L/s] per ton at.3 inches [.7 kpa] of external static pressure. Enhanced airflow up to.7" external static pressure. Cabinet air leakage less than 2.0% at 1.0 inch H 2O when tested in accordance with ASHRAE Standard 193. *WiFi broadband internet connection required. Download the EcoNet App from the App Store or Google Play to set up your EcoNet Smart Thermostat. Receipt of notification depend on home WiFi set up. WiFi broadband internet connection required. FORM NO. H11-558 REV. 3

Table of Contents TABLE OF CONTENTS Engineering Features...3 Model Number Identification...4 Dimensional Data...5-6 Airflow Directional Data...7 Airflow Performance Data...8-10 Electrical Data...11-14 Electrical Wiring...15 Accessories...16 Limited Warranty...17 2

Engineering Features Engineering Features RHMV- Series WiFi broadband internet connection required. Download the EcoNet App from the App Store or Google Play to set up your EcoNet Smart Thermostat. Receipt of notification depend on home WiFi set up. WiFi broadband internet connection required. Equipped with an electronic expansion valve (EEV), which can intelligently change the EEV position based on system demands. By the measurement of the suction pressure via the vapor line pressure transducer (factory installed) and the vapor line thermistor (field connected to the vapor line, but factory provided within the air handler) the EcoNet enabled air handler control calculates the suction superheat at the indoor coil. This calculation permits the air handler control to make decisions for when to open and close the EEV for the purpose of maintaining a predetermined suction superheat. The EEV is equipped with a 4-pole removable external stator, and inlet and outlet chatleff fittings for optimal serviceability. These valves also have an internal check valve to provide heat pump compatibility. When operating in heating mode, the air handler control will open the EEV completely to permit the check valve to operate and maximize reverse refrigerant flow. The most compact unit design available, all standard heat air handler models only 42 1 /2 to 57 inches [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have copper sweat refrigerant connections. Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2 inches [51 mm] for 1 1 /2 inch [38 mm] conduit. Front refrigerant and drain connections. [ ] Designates Metric Conversions 3

Model Number Identification R H M V 24 17 S E A C J A *** Option Code (see ADS-3803) Blank = None Minor Series A = First Voltage A = 115/1/60 D = 480V/3/60 J = 208/240/1/60 Controls C = Communicating N = Non-Communicating Major Series A = First Metering Device T = TEV E = EEV P = Piston Coil Efficiency S = Standard M= Medium H = High U = Ultra Width 17 = 17.5" [431.8 mm] (600-1200 CFM) 21 = 21" [533.4 mm] (800-1600 CFM) 24 = 24.5" [609.6 mm] (1400-1800 CFM) Nominal Capacity 24 = 18,000 [5.27 kw]-24,000 [7.03 kw] BTU/H 36 = 30,000 [8.79 kw]-36,000 [10.55 kw] BTU/H 48 = 42,000 [12.31 kw]-48,000 [14.06 kw] BTU/H 60 = 60,000 [17.58 kw] BTU/H Motor Type V = Constant CFM Variable Speed (ECM) Stages of Air Flow M= Modulating Product Category H = Air Handler Rheem [ ] Designates Metric Conversions Available Models at J Voltage RHMV2417SEACJA RHMV2421MEACJA RHMV2421HEACJA RHMV2421UEACJA RHMV3617SEACJA RHMV6021SEACJA RHMV6024MEACJA 4

Unit Dimensions Return Air Opening Dimensions Model Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches) 17 15 7 /8 19 3 /4 21 19 3 /8 19 3 /4 24 22 7 /8 19 3 /4 Air Dimensional Data [ ] Designates Metric Conversions ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7 /8 [22.2 mm], 1 3 /32 [27.8 mm], 1 31 /32 [50 mm] DIA. KNOCKOUTS. SUPPLY AIR 10 5 /16 [262 mm] NOTE: 24 CLEARANCE REQUIRED IN FRONT OF UNIT FOR FILTER AND COIL MAINTENANCE. W LOW VOLTAGE CONNECTION 5/8 [15.9 mm] AND 7 /8 [22.2 mm] KNOCKOUT A H AUXILIARY DRAIN CONNECTION 3/4 [19.1 mm] FEMALE PIPE THREAD (NPT) HORIZONTAL APPLICATION ONLY PRIMARY DRAIN CONNECTION 3/4 [19.1 mm] FEMALE PIPE THREAD (NPT) AUXILIARY DRAIN CONNECTION 3/4 [19.1 mm] FEMALE PIPE THREAD (NPT) UPFLOW/DOWNFLOW APPLICATION ONLY LIQUID LINE CONNECTION COPPER (SWEAT) 19 1 /2 [495 mm] RETURN AIR OPENING 21 11 /16 [551 mm] VAPOR LINE CONNECTION COPPER (SWEAT) UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. Unit Dimensions & Weights Model Size RHMV Refrigerant Connections Sweat (In.) [mm] ID Liquid Vapor Unit Height H In. [mm] Unit Width W In. [mm] Supply Duct A In. [mm] Unit Weight/Shipping Weight (Lbs.) [kg] Unit With Coil (Max. KW) 2417SE 3/8 [9.53] 3/4 [19.05] 42 1 /2 [1080] 17 1 /2 [444.5] 16 1 /2 [406.4] 92/106 [42/48] 2421ME 3/8 [9.53] 3/4 [19.05] 42 1 /2 [1080] 21 1 /2 [533.4] 19 1 /2 [495.3] 111/126 [50/57] 2421HE 3/8 [9.53] 7/8 [22.23] 55 1 /2 [1410] 21 1 /2 [533.4] 19 1 /2 [495.3] 130/146 [59/66] 2421UE 3/8 [9.53] 7/8 [22.23] 57 1 /2 [1448] 21 1 /2 [533.4] 19 1 /2 [495.3] 641/153 [64/69] 3617SE 3/8 [9.53] 3/4 [19.05] 42 1 /2 [1080] 17 1 /2 [444.5] 16 1 /2 [406.4] 96/110 [44/50] 6021SE 3/8 [9.53] 7/8 [22.23] 57 1 /2 [1448] 21 1 /2 [533.4] 19 1 /2 [495.3] 141/153 [64/69] 6024ME 3/8 [9.53] 7/8 [22.23] 55 1 /2 [1410] 24 1 /2 [622.3] 23 1 /2 [584.0] 161/178 [73/81] *Maximum dehumidification airflow. 5

Dimensional Data Unit Dimensions [ ] Designates Metric Conversions 5 15 /16 [151 mm] 4 1 /8 [105 mm] 3 1 /16 [76 mm] 1 3 /16 [48 mm] 11 /8 [29 mm] 1 1 /16 [27 mm] 1 3 /8 [35 mm] 2 13 /16 [71 mm] 5 1 /4 [133 mm] 5 3 /8 [136 mm] 6

Airflow Directional Data Airflow Directional Data UPFLOW DOWNFLOW HORIZONTAL LEFT HAND AIRFLOW HORIZONTAL RIGHT HAND AIRFLOW 7

Airflow Performance Data Airflow Performance Airflow performance data is based on cooling performance with a coil and no filter in place. Select performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For optimum blower performance, operate the unit in the.3 [8 mm] to.7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of.1 inch [3 mm] W.C. external static range. Airflow Operating Limits Model Cabinet Width 17/21 17/21 Cooling BTUH x 1,000 Cooling Tons Nominal Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37.5 CFM [18 L/s]/1,000 BTUH) (450 CFM [212 L/s]/Ton Nominal) Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,200 BTUH) (360 CFM [170 L/s]/Ton Nominal) Maximum kw Electric Heating & Minimum Electric Heat CFM [L/s] -24 2 900 [425] 800 [378] 720 [340] -36 3 1350 [637] 1200 [566] 1080 [510] 13 18 Maximum Electric Heat Rise F [ C] 63 [17.2] 51 [10.6] 21-48/-60 4/5 1800 [850] 1600 [755] 1440 [680] 25 50 [10] 24-60 5 1930 [911] 1800 [850] 1620 [765] 30 54 [12.2] [ ] Designates Metric Conversions 8

Airflow Performance Data RHMV Legacy Wiring Airflows in CFM [LPS] Model Blower Motor HP Dip Switch S1/S2 Dip Switch S3/S4 Y1 + Y2 Cool/Heat Y1 Y1 + 15 Min Y1 + B Y1 + B + 15 Min Dehum (ODD) Multiplier Max External Static* Matched OD Model** RHMV2417SEACJA 1/3 ANY ANY 750 [354] / 750 [354] 548 [259] 548 [259] 540 [255] 540 [255] 0.85 1.00 iwc (-)P1724A, (-)A1724A* RHMV2421MEACJA 1/3 ANY ANY 835 [394] / 835 [394] 309 [146] 459 [217] 309 [146] 459 [217] 0.85 1.00 iwc (-)A2024A, (-)A1724A* RHMV2421HEACJA 1/2 ANY ANY 855 [404] / 825 [389] 325 [153] 581 [274] 561 [265] 652 [308] 0.85 1.00 iwc (-)A2024A RHMV2421UEACJA 3/4 ANY ANY 800 [378] / 800 [378] 304 [143] 427 [202] 266 [126] 427 [202] 0.85 1.00 iwc (-)P2024B RHMV3617SEACJA 1/2 ANY ANY 1235 [583] / 1235 [583] 655 [309] 655 [309] 655 [309] 655 [309] 0.85 1.00 iwc (-)P1736A*, (-)A1736A* RHMV6021SEACJA 3/4 OFF/OFF OFF/OFF 1660 [783] / 1600 [755] 630 [297] 890 [420] 530 [250] 855 [404] 0.85 1.00 iwc (-)P2048A, (-)P2048B, (-)P2060B RHMV6021SEACJA 3/4 ON/OFF ANY 1565 [739] 595 [281] 835 [394] 0.85 1.00 iwc (-)RA2048A, (-)A1736A*, (-)A1748A* RHMV6021SEACJA 3/4 OFF/ON OFF/ON 1235 [583] / 1225 [578] 470 [222] 660 [311] 620 [293] 950 [448] 0.85 1.00 iwc (-)P2036A, (-)P2036B, (-)A1736A* RHMV6024MEACA 3/4 ANY ANY 1670 [788] 500 [236] 500 [236] 0.85 1.00 iwc (-)A1736A* (-)A1748A* (-)A1760A* RHMV6024MEACA 3/4 ANY ANY 1670 [788] / 1675 [791] 500 [236] 755 [356] 500 [236] 755 [356] 0.80 0.80 iwc (-)A2060A, (-)P2060A Legacy Wiring reccomended only for limited use Temporary use for (-)P20 B models only * Legacy Wiring when matched with (-)A17 models will result in unacceptable airflows Do not use 9

Airflow Performance Data RHMV EcoNet Wired Airflows in CFM [LPS] Model OD Model High Cool Low Cool Charge Cool** High Heat Low Heat Charge Heat** Max Dehum Multiplier Max External Static* RHMV2417SEACJA (-)P1724A 770 [363] 570 [269] 770 [363] 570 [269] 0.85 1.00 iwc RHMV2417SEACJA (-)A1724A 720 [340] 535 [252] 0.85 1.00 iwc RHMV2421MEACJA (-)A2024A 840 [396] 310 [146] 0.85 1.00 iwc RHMV2421MEACJA (-)A1724A 720 [340] 535 [252] 0.85 1.00 iwc RHMV2421HEACJA (-)A2024A 840 [396] 310 [146] 0.85 1.00 iwc RHMV2421UEACJA (-)P2024B 800 [378] 500 [236] 800 [378] 800 [378] 600 [283] 800 [378] 0.85 1.00 iwc RHMV3617SEACJA (-)P1736A 1235 [583] 675 [319] 1235 [583] 675 [319] 0.85 1.00 iwc RHMV3617SEACJA (-)A1736A 1075 [507] 825 [389] 0.85 1.00 iwc RHMV6021SEACJA (-)A2036A 1210 [571] 580 [274] 0.85 1.00 iwc RHMV6021SEACJA (-)A1736A 1075 [507] 825 [389] 0.85 1.00 iwc RHMV6021SEACJA (-)A1748A 1405 [663] 1055 [498] 0.85 1.00 iwc RHMV6021SEACJA (-)A1760A 1580 [746] 1200 [566] 0.85 1.00 iwc RHMV6021SEACJA (-)P2036A 1225 [578] 471 [222] 1225 [578] 471 [222] 0.85 1.00 iwc RHMV6021SEACJA (-)P2036B 1200 [566] 516 [244] 1200 [566] 1300 [614] 960 [453] 1300 [614] 0.85 1.00 iwc RHMV6021SEACJA (-)P1748A 1435 [677] 900 [425] 1435 [677] 900 [425] 0.85 1.00 iwc RHMV6021SEACJA (-)P2048A 1600 [755] 516 [244] 1600 [755] 516 [244] 0.85 1.00 iwc RHMV6021SEACJA (-)P2048B 1600 [755] 550 [260] 1600 [755] 1500 [708] 950 [448] 1500 [755] 0.85 1.00 iwc RHMV6021SEACJA (-)A2048A 1565 [739] 475 [224] 0.85 1.00 iwc RHMV6021SEACJA (-)P1760A 1575 [743] 880 [415] 1575 [743] 880 [415] 0.85 0.80 iwc RHMV6021SEACJA (-)P2060B 1700 [802] 1100 [519] 1700 [802] 1800 [850] 1100 [519] 1800 [850] 0.85 0.80 iwc RHMV6024MEACA (-)A2060A 1725 [814] 516 [244] 0.80 0.80 iwc RHMV6024MEACA (-)A1736A 1075 [507] 825 [389] 0.85 1.00 iwc RHMV6024MEACA (-)A1748A 1405 [663] 1055 [498] 0.85 1.00 iwc RHMV6024MEACA (-)A1760A 1580 [746] 1200 [566] 0.85 1.00 iwc RHMV6024MEACA (-)P2060A 1670 [788] 516 [244] 1670 [788] 516 [244] 0.80 0.80 iwc **Do Not Exceed Return Static after filter of more than 0.5"wc in design or condensate trap may not be sufficient **Charge Mode only available on (-)P20 B models Airflow When Electric Heat is on is controlled by EcoNet based on Air Handler Electric Heat Setup in EcoNet Smart Thermostat. 10

Electrical Data Electrical Data Motor Only No Electric Heat RHMV Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Model (-)HMV Voltage Phase Hz Motor HP Motor Amps Minimum Circuit Ampacity Maximum Overcurrent Protector 2417SE 1/3 2.7 3.4 15 / 15 2421ME 1/3 2.9 3.6 15 / 15 2421HE 1/2 3.9 4.9 15 / 15 2421UE 208 / 240 1 60 3/4 4.3 5.4 15 / 15 3617SE 1/2 3.4 4.3 15 / 15 6021SE 3/4 4.9 6.1 15 / 15 6024ME 3/4 4.9 6.1 15 / 15 NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x 3.414 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (230V) single phase air handler is designed to be used with single or three phase 230 volt electric heaters. In the case of connecting 3-phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A21 and RXBJ-A31 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 50% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out [ ] Designates Metric Conversions 11

Electrical Data Electrical Data With Electric Heat RHMV Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RHMV 2417SEAC 2421MEAC 2421HEAC Heater Kit Model RXBH Circuit Voltage Phase / Hertz No. Elements Heater kw (208 / 240) Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection RXBH-1724A03J Single 208 / 240 1 / 60 1 10.8 / 12.5 1.7 16 / 18 20 / 20 RXBH-1724A05J Single 208 / 240 1 / 60 1 17.3 / 20.0 1.7 24 / 28 25 / 30 RXBH-1724A07J Single 208 / 240 1 / 60 2 26.0 / 30.0 1.7 35 / 40 35 / 40 RXBH-1724A10J Single 208 / 240 1 / 60 2 34.6 / 40.0 1.7 46 / 53 46 / 53 RXBH-1724B/C05J Single 208 / 240 1 / 60 1 17.3 / 20.0 1.7 24 / 28 25 / 30 RXBH-1724B/C07J Single 208 / 240 1 / 60 2 26.0 / 30.0 1.7 35 / 40 35 / 40 RXBH-1724B/C10J Single 208 / 240 1 / 60 2 34.6 / 40.0 1.7 46 / 53 46 / 53 RXBH-1724A03J Single 208 / 240 1 / 60 1 10.8 / 12.5 1.7 16 / 18 20 / 20 RXBH-1724A05J Single 208 / 240 1 / 60 1 17.3 / 20.0 1.7 24 / 28 25 / 30 RXBH-1724A07J Single 208 / 240 1 / 60 2 26.0 / 30.0 1.7 35 / 40 35 / 40 RXBH-1724A10J Single 208 / 240 1 / 60 2 34.6 / 40.0 1.7 46 / 53 46 / 53 RXBH-1724B/C05J Single 208 / 240 1 / 60 1 17.3 / 20.0 1.7 24 / 28 25 / 30 RXBH-1724B/C07J Single 208 / 240 1 / 60 2 26.0 / 30.0 1.7 35 / 40 35 / 40 RXBH-1724B/C10J Single 208 / 240 1 / 60 2 34.6 / 40.0 1.7 46 / 53 46 / 53 RXBH-1724A03J Single 208 / 240 1 / 60 1 10.8 / 12.5 3.4 18 / 20 20 / 20 RXBH-1724A05J Single 208 / 240 1 / 60 1 17.3 / 20.0 3.4 26 / 29.25 30 / 30 RXBH-1724A07J Single 208 / 240 1 / 60 2 26.0 / 30.0 3.4 37 / 42 40 / 45 RXBH-1724A10J Single 208 / 240 1 / 60 2 34.6 / 40.0 3.4 48 / 55 50 / 60 RXBH-1724B/C05J Single 208 / 240 1 / 60 1 17.3 / 20.0 3.4 26 / 29.25 30 / 30 RXBH-1724B/C07J Single 208 / 240 1 / 60 2 26.0 / 30.0 3.4 38 / 43 40 / 45 RXBH-1724B/C10J Single 208 / 240 1 / 60 2 34.6 / 40.0 3.4 49 / 56 50 / 60 RXBH-1724A03J Single 208 / 240 1 / 60 1 10.8 / 12.5 4.3 19 / 21 20 / 25 RXBH-1724A05J Single 208 / 240 1 / 60 1 17.3 / 20.0 4.3 27 / 31 30 / 35 RXBH-1724A07J Single 208 / 240 1 / 60 2 26.0 / 30.0 4.3 38 / 43 40 / 45 2421UEAC RXBH-1724A10J Single 208 / 240 1 / 60 2 34.6 / 40.0 4.3 49 / 56 50 / 60 RXBH-1724B/C05J Single 208 / 240 1 / 60 1 17.3 / 20.0 4.3 27 / 31 30 / 35 RXBH-1724B/C07J Single 208 / 240 1 / 60 2 26.0 / 30.0 4.3 38 / 43 40 / 45 RXBH-1724B/C10J Single 208 / 240 1 / 60 2 34.6 / 40.0 4.3 49 / 56 50 / 60 NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x 3.414 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (230V) single phase air handler is designed to be used with single or three phase 230 volt electric heaters. In the case of connecting 3-phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A21 and RXBJ-A31 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 50% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out [ ] Designates Metric Conversions 12

Electrical Data Electrical Data With Electric Heat RHMV (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RHMV 3617SEAC 6021SEAC Heater Kit Model RXBH Circuit Voltage Phase / Hertz No. Elements Heater kw (208 / 240) Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection RXBH-1724A03J Single 208 / 240 1 / 60 1 10.8 / 12.5 3.4 18 / 20 20 / 20 RXBH-1724A05J Single 208 / 240 1 / 60 1 17.3 / 20.0 3.4 26 / 29.25 30 / 30 RXBH-1724A07J Single 208 / 240 1 / 60 2 26.0 / 30.0 3.4 37 / 42 40 / 45 RXBH-1724A10J Single 208 / 240 1 / 60 2 34.6 / 40.0 3.4 48 / 55 50 / 60 RXBH-1724A15J Single* 208 / 240 1 / 60 3 51.9 / 60.0 3.4 70 / 80 70 / 80 Multi-Ckt. 1 208 / 240 1 / 60 1 17.3 / 20.0 3.4 26 / 29.25 30 / 30 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 44 / 50 45 / 50 Single* 208 / 240 1 / 60 3 51.9 / 60.0 3.4 82 / 93 90 / 100 RXBH-1724A18J Multi-Ckt. 1 208 / 240 1 / 60 1 17.3 / 20.0 3.4 30 / 34 30 / 35 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 52 / 59 60 / 60 RXBH-1724B/C05J Single 208 / 240 1 / 60 1 17.3 / 20.0 3.4 26 / 29.25 30 / 30 RXBH-1724B/C07J Single 208 / 240 1 / 60 2 26.0 / 30.0 3.4 37 / 42 40 / 45 RXBH-1724B/C10J Single 208 / 240 1 / 60 2 34.6 / 40.0 3.4 48 / 55 50 / 60 RXBH-1724A05J Single 208 / 240 1 / 60 1 17.3 / 20.0 4.9 28 / 32 30 / 35 RXBH-1724A07J Single 208 / 240 1 / 60 2 26.0 / 30.0 4.9 39 / 44 40 / 45 RXBH-1724A10J Single 208 / 240 1 / 60 2 34.6 / 40.0 4.9 50 / 57 50 / 60 RXBH-1724A15J RXBH-1724A18J RXBH-24A20J Single* 208 / 240 1 / 60 3 51.9 / 60.0 4.9 72 / 82 80 / 90 Multi-Ckt. 1 208 / 240 1 / 60 1 17.3 / 20.0 4.9 26 / 30 30 / 30 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 44 / 50 45 / 50 Single* 208 / 240 1 / 60 3 51.9 / 60.0 4.9 84 / 95 90 / 100 Multi-Ckt. 1 208 / 240 1 / 60 1 17.3 / 20.0 4.9 32 / 36 35 / 40 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 52 / 59 60 / 60 Single* 208 / 240 1 / 60 4 51.9 / 60.0 4.9 93 / 107 100 / 110 Multi-Ckt. 1 208 / 240 1 / 60 2 34.6 / 40.0 4.9 50 / 57 50 / 60 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 44 / 50 45 / 50 Single** 208 / 240 1 / 60 6 18.0 / 24.0 4.9 115 / 132 125 / 150 RXBH-24A25J Multi-Ckt. 1 208 / 240 1 / 60 2 6.0 / 8.0 4.9 43 / 48 45 / 50 Multi-Ckt. 2 208 / 240 1 / 60 2 6.0 / 8.0 0.0 37 / 42 40 / 45 Multi-Ckt. 3 208 / 240 1 / 60 2 6.0 / 8.0 0.0 37 / 42 40 / 45 RXBH-1724B/C05J Single 208 / 240 1 / 60 1 17.3 / 20.0 4.9 28 / 32 30 / 35 RXBH-1724B/C07J Single 208 / 240 1 / 60 2 26.0 / 30.0 4.9 39 / 44 40 / 45 RXBH-1724B/C10J Single 208 / 240 1 / 60 2 34.6 / 40.0 4.9 50 / 57 50 / 60 NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x 3.414 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (230V) single phase air handler is designed to be used with single or three phase 230 volt electric heaters. In the case of connecting 3-phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A21 and RXBJ-A31 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 50% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out [ ] Designates Metric Conversions 13

Electrical Data Electrical Data With Electric Heat RHMV (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RHMV 6024MEAC Heater Kit Model RXBH Circuit Voltage Phase / Hertz No. Elements Heater kw (208 / 240) Motor Ampacity Minimum Circuit Ampacity Maximum Circuit Protection RXBH-1724A05J Single 208 / 240 1 / 60 1 17.3 / 20.0 4.9 28 / 32 30 / 35 RXBH-1724A07J Single 208 / 240 1 / 60 2 26.0 / 30.0 4.9 39 / 44 40 / 45 RXBH-1724A10J Single 208 / 240 1 / 60 2 34.6 / 40.0 4.9 50 / 57 50 / 60 RXBH-1724A15J RXBH-1724A18J RXBH-24A20J RXBH-24A25J Single* 208 / 240 1 / 60 3 51.9 / 60.0 4.9 72 / 82 80 / 90 Multi-Ckt. 1 208 / 240 1 / 60 1 17.3 / 20.0 4.9 28 / 32 30 / 35 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 44 / 50 45 / 50 Single* 208 / 240 1 / 60 3 51.9 / 60.0 4.9 84 / 95 90 / 100 Multi-Ckt. 1 208 / 240 1 / 60 1 17.3 / 20.0 4.9 32 / 36 35 / 40 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 52 / 59 60 / 60 Single* 208 / 240 1 / 60 4 51.9 / 60.0 4.9 93 / 107 100 / 110 Multi-Ckt. 1 208 / 240 1 / 60 2 34.6 / 40.0 4.9 50 / 57 50 / 60 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 44 / 50 45 / 50 Single** 208 / 240 1 / 60 6 87.0 / 99.9 4.9 115 / 132 125 / 150 Multi-Ckt. 1 208 / 240 1 / 60 2 29.0 / 33.3 4.9 43 / 48 45 / 50 Multi-Ckt. 2 208 / 240 1 / 60 2 29.0 / 33.3 0.0 37 / 42 40 / 45 Multi-Ckt. 3 208 / 240 1 / 60 2 29.0 / 33.3 0.0 37 / 42 40 / 45 Single** 208 / 240 1 / 60 6 103.8 / 120.0 4.9 115 / 132 125 / 150 RXBH-24A30J Multi-Ckt. 1 208 / 240 1 / 60 2 34.6 / 40.0 4.9 43 / 48 45 / 50 Multi-Ckt. 2 208 / 240 1 / 60 2 34.6 / 40.0 0.0 37 / 42 40 / 45 Multi-Ckt. 3 208 / 240 1 / 60 2 34.6 / 40.0 0.0 37 / 42 40 / 45 RXBH-1724B/C05J Single 208 / 240 1 / 60 1 17.3 / 20.0 4.9 28 / 32 30 / 35 RXBH-1724B/C07J Single 208 / 240 1 / 60 2 26.0 / 30.0 4.9 39 / 44 40 / 45 RXBH-1724B/C10J Single 208 / 240 1 / 60 2 34.6 / 40.0 4.9 50 / 57 50 / 60 NOTES: * Values only. No single point kit available. Electric heater BTUH - (heater watts + motor watts) x 3.414 (see airflow table for motor watts.) Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger fuse size. J Voltage (230V) single phase air handler is designed to be used with single or three phase 230 volt electric heaters. In the case of connecting 3-phase power to the air handler terminal block without the heater, bring only two leads to the terminal block. Cap, insulate and fully secure the third lead. If the kit is listed under both single and multiple circuits, the kit is shipped from factory as multiple circuits. For single phase application, Jumper bar kit RXBJ-A21 and RXBJ-A31 can be used to convert multiple circuits to a single supply circuit. Refer to Accessory Section for details. The airflow for continuous fan is set 50% of the cooling airflow.?heater kits connection type. A=Breaker B=Terminal Block C=Disconnect Pull Out [ ] Designates Metric Conversions 14

Electrical Wiring Electrical Wiring Power Wiring Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. Supply wiring must be 75 C minimum copper conductors only. See electrical data for product Ampacity rating and Circuit Protector requirement. Accessories Combustible Floor Base RXHB- Model Cabinet Size 17 21 24 Combustible Floor Base Model Number RXHB-17 RXHB-21 RXHB-24 Jumper Bar Kit 3 Ckt. to 1 Ckt. RXBJ-A31 is used to convert single phase multiple three circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Jumper Bar Kit 2 Ckt. to 1 Ckt. RXBJ-A21 is used to convert single phase multiple two circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Note: No jumper bar kit is available to convert three phase multiple two circuit units to a single supply circuit. Auxiliary Horizontal Overflow Pan Accessory RXBM- Nominal Cooling Capacity-Tons Auxiliary Horizontal Overflow Pan Accessory Model Number 2-3 RXBM-AC48 4-5 RXBM-AC61 Supply and Return Air Sensor Kit RXHT-A02 The RXHT-A02 Thermistor Kit is to be used with the air handler control to monitor the system return and leaving air temperatures. These temperatures can be monitored with the EcoNet communicating thermostat. Grounding This product must be sufficiently grounded in accordance with National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. A grounding lug is provided. Auxiliary Electric Heater Kits RXBH- Heater Kits include circuit breakers which meet UL and cul requirements for service disconnect. See the Electric Heat Electrical Data in this specification sheet for specific Heater Kit Model numbers. Horizontal Adapter Kit RXHH- This horizontal adapter kit is used to convert Upflow/Downflow only models to horizontal flow. See the following table to order proper horizontal adapter kit. Coil Model Model Cabinet Size Horizontal Adapter Kit Model Number (Single Qty.) Filter Size In. [mm] 17 16 x 20 [406 x 508] 21 20 x 20 [508 x 508] Horizontal Adapter Kit Model Number (10-Pack Qty.) 2414 2417 RXHH-A01 RXHH-A02 RXHH-A01 x 10 RXHH-A02 x 10 2421/3617/3621 RXHH-A03 RXHH-A03 x 10 4821/4824/6021 RXHH-A06 RXHH-A06 x 10 6024 RXHH-A05 RXHH-A05 x 10 Part Number* RXHF-17 RXHF-21 15.70 19.20 24 25 x 20 [635 x 508] RXHF-24 22.70 *Accommodates 1" or 2" filter A B 17.5 21.0 25.5 External Filter Base RXHF- RXHF- [ ] Designates Metric Conversions 15

Accessories THE ECONET SMART THERMOSTAT BUILT-IN WIFI 4.3 LCD TOUCH SCREEN LOCAL WEATHER Current conditions plus 6-day forecast 5 OPERATING MODES Heat, Cool, Auto, Emergency Heat and Fan Only 7-DAY PROGRAMMABLE SCHEDULE Offers comfort without thought ONE-TOUCH AWAY Quickly switch to your energy-saving away preferences VACATION SCHEDULING Allows you to save while you re away and come home to comfort MOTION SENSOR Automatically wakes the screen as you approach STANDBY SCREEN Displays indoor temperature and current weather RETST700SYS OPERATIONAL FEATURES AUTOMATIC CHANGEOVER Transitions between heating and cooling automatically to keep the house comfortable INTEGRATED WATER CONTROL Enables easy water heater management SMOOTH ARRIVAL Prompts the system to start ahead of schedule to ensure the home is at the desired temperature at the scheduled time HUMIDITY CONTROL Supports humidifier accessories or over-cool based dehumidification DETAILED OPERATING STATUS View pertinent equipment status information and run times CONTINUOUS FAN Offers 5 speeds (Low, Medium Low, Medium, Medium High, High) SHORT-CYCLE PROTECTION Avoids damage to equipment from short run cycles MONITORING & REMOTE CONTROL FEATURES ACTIVE MONITORING Alerts to problems that need immediate attention REMOTE CONTROL Allows adjusting of comfort and settings from anywhere using a mobile device SERVICE ALERTS Sends routine maintenance reminders AIR FILTER MONITORING Detects when it s time to replace the air filter ALARM HISTORY Displays time-stamped alarm codes with clear descriptions ECONET SMART THERMOSTAT COMPATIBILITY Heating & Cooling Gas Furnaces Air Handlers Air Conditioners Heat Pumps Models R802V R96V R97V R98V RHMV RH2T RA20 RA17* RP20 RP17 RETST700SYS *Models not EcoNet Enabled: RA1724AJ2NB, RA1736AJ2NB, RA1748AJ2NB, RA1760AJ2NB 16

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. Parts...Ten (10) Years *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 17

Notes 18

Notes 19

The new degree of comfort. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.rheem.com Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A. 6/18 QG FORM NO. H11-558 REV. 3