Fixing points M6 (1/4 )

Similar documents
Uniclass. Epic K4:Y46 (63) X (R5) Vitesse Modular. Reinventing lighting connection systems 2.2. Issue

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Direct Dim Microwave Presence/Absence Detector

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMHS (standard & slim-line PSU)

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Analogue Dimming Microwave Presence/Absence Detector

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

An-10 Wireless lighting control technology

An-10 Wireless lighting control technology

Ceiling Microwave presence/absence detector 12-24V AC/DC

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

SENSA MRE DDM MR

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

SWITCHLITE MRE DDM ADJ

LPC3BSP65 & LPC3BDP65

, ,

Standalone Presence Detectors

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Integrated PIR detectors

LPCMPIRM65 & LPCMPIRDSI65

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Ceiling PIR HS presence detector. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

SWITCHLITE MRE SLDM ADJ

Secure connection system

EBDSPIR-PRM-LV Product Guide

Fully addressable lighting control system. Issue

MWS3A-PRM Product Guide

µdim Microwave Sensors User Manual

MANUFACTURED IN THE UK

LIGHTING CONTROL SYSTEM

Sensors Explained AUTOMATION

klik Lighting connection and control catalogue

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

OEM Lighting Controls. Products & Solutions. Brochure 5.1. Issue

For Heavy Duty Commercial and Industrial Environments

MWS3 Ceiling Mount Microwave Occupancy Detector

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

Loadstar AC/DC Systems

Instruction Manual WARNINGS

Emergency Assist Alarm Kit Single Zone

MODLED SLIM INTRODUCTION PRODUCT SPECIFICATION

TX1 ArcMesh transmitter

Electrisaver User and Installation Instructions

An introduction to... Sigma

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

SURFACE WARM CEILING HEATERS

USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP?

12W Round LED Wall/Ceiling Light with Microwave Sensor

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

User Information Sheet 008 : 2010

CONTENTS NBM-06 Bell (6") Page 1

CHALLENGER 66 INDUSTRIAL

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

Data sheet. Function description. Benefits

HIGH BAY APPLICATIONS

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

CAPO LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION. Introduction

Kam StarWash Multicolour wash effects with green & red star cluster laser

IP65 High Bay Dual Sense Sensor

Energy efficient lighting control

Lighting, Connection & Control

1592P01. for liquids in piping DN

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

360 Ceiling PIR Light Controller

GRADUATE LED RECESSED

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

5000 INSTALLATION GUIDE

360 Surface Mount Ceiling PIR Light Controller

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

SECTION LOW VOLTAGE LIGHTING CONTROLS

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

18W Round LED Wall/Ceiling Light with Microwave Sensor

Commercial Fan Heater

Product Specifications Dialog Room Controller* (*patent pending)

Transcription:

146mm 127mm VITM6 Product Guide Vitesse Modular 6 - Dimming Modules Overview The Vitesse modular system is a cost effective method of providing power and control for lighting installations in industrial, commercial and retail buildings. The system is designed for ease of installation: mains input is connected using the spacious wiring compartment; control inputs and outputs are pluggable using industry standard connectors. The modular approach allows for between 4 and 16 luminaires to be connected. The VITM6 is for use with dimming luminaires. The VITM6-SELVMOD converter provides SELV switch inputs to allow digital dimming whilst also overcoming the requirements of the IEE 17 th edition wiring regulations cost effectively. System Components 202mm 150mm Fixing points M6 (1/4 ) 122mm 75mm 9 pole interface connector and lead supplied with detectors VITM6-S Vitesse modular starter for dimming systems Height - allow 150mm for total height of unit (including connectors and cable) VITM6-E Vitesse modular extender for dimming systems VITM6-SELVMOD Pluggable dimming switch module Installation BESA box fixings Removable gland plate with 3 x Ø20mm knockouts Channel for channel nuts (zebs) 3 x Ø20mm knockouts for rear cable entry 4 x key slots to accept M6 (1/4 ) fixings Warning. This device works at mains voltage. Be sure to take care when working with electricity. The box should be fixed on a smooth, flat surface or using drop rod fixings attached to channel nuts. Ensure that there is easy access to the wiring compartment and all connectors once the box is in-situ.

Wiring Dim + Dim - Permanent Live Neutral Earth Switched live Off On Large cables Small cables Live Cable clamps Luminaire connections / Lead colours All wiring should be mains rated. Remove wiring compartment cover. Wire the box using the diagrams opposite Permanent live feeds emergency fittings Off/On connects switches through to detectors Switched live turns the lights on and off Use the cable clamps to secure the wiring or use cable glands (not supplied). The clamps can be split, and flipped over to clamp different cable diameters. Replace wiring compartment cover. Plug in the luminaires ensuring that the connector latches to the box. Dim + Red Dim - White Permanent Live Black (6 core only) Neutral Blue Earth Green / Yellow Switched Live Brown 2

Wiring & Emergency Test Local lighting switch and local emergency test switch Local lighting switch Local emergency test switch Dimming input DALI / DSI / 1- Emergency test using power interruption Dimming input DALI / DSI / 1-10V Wire link A local lighting switch may still be used when there is a central emergency test switch or when a circuit breaker is used to interrupt the power. DO NOT WIRE ACROSS PHASES 3

Wiring & Emergency Test Emergency test using central switch Multiple boxes Central emergency test switch Dimming input DALI / DSI / 1-10V A local lighting switch may still be used when there is a central emergency test switch. DO NOT WIRE ACROSS PHASES 4

Presence detector connections - no switches Automatic on, automatic off Detector lead supplied with detector. Where multiple detectors connect to a single box a dual lead is available VITM6-LD3-DD. Sensor 5

Absence/presence detector connections - with switches Centre biased retractive wall switch (part no. MK K4900 or equivalent). Press and release to provide On/ Off switching; press and hold to provide Up / Down dimming. Detector lead supplied with detector. Where multiple detectors connect to a single box a dual lead is available VITM6-LD3-DD. Sensor Switch operation Up position Short press on Long press dimming level up Down position Short press off Long press dimming level down DO NOT WIRE ACROSS PHASES 6

On/up Common Off/down On/up Common Off/down VITM6-SELVMOD Dimming Module Features No mains voltage switch wires routed along walls removes the need for RCD protection under the IEE 17th Edition regulations. The VITM6-SELVMOD module allows switches in parallel for 2-way and intermediate switching. The same switch can be used when multiple Vitesse Modular boxes are connected to different phases. Selectable for DALI or DSI digital dimming control. Luminaires must be fitted with suitable dimming ballasts; up to 20 ballasts can be controlled. Two speeds of dimming rate selectable. Operation Up button Short press on Long press dimming level up Down button Short press off Long press dimming level down Wiring Diagram Settings Switch Control 1 Off DSI 1 On DALI SELV switch connector Switch Dimming rate 2 Off Fast 2 On Slow Low voltage (SELV) wiring No requirement for: Containment RCDs Important note Ensure that a wire link is added as shown below Momentary switches, centre biased retractive Wire link 7

Ceiling rose / conduit box connection Conduit box to VITM6-S mains wiring Use a VITM-ROSE when there is a need to take power from a conduit box. Plug the connector into the VITM-ROSE and wire the other end of the lead into the terminals of the VITM6-S. A pre-wired version is available, VITM6-SL1. VITM-ROSE mains wiring Each pole accepts 1 x 4mm 2 or 2 x 2.5mm 2 Live supply Screw fixings to conduit box Earth Neutral VITM-ROSE Pre-wired lead See below for length part numbers Permanent Live VITM-ROSE connector wiring Permanent Live Neutral Earth Live supply Part numbers Modules VITM6-S VITM6-E VITM6-SL1 Presence / Absence Detectors VITM6-EBDSPIR-DD VITM6-MWS3A-DD VITM6-MWS6-DD VITM6-EBMPIR-DD 6 pole starter box 6 pole extender box 6 pole starter box with 1m lead and ceiling rose connector Direct Dim PIR presence/ absence detector Direct Dim Microwave presence/ absence detector Direct Dim Microwave presence/ absence detector Direct Dim Miniature PIR presence detector Dual Detector Leads (LSF) VITM6-LD3-DD 3m Direct Dim sensor lead Luminaire Leads (LSF) VITM6L503100W 5 core 3m 1.0mm 2 White plug VITM6L505100W 5 core 5m 1.0mm 2 White plug VITM6L603100R 6 core 3m 1.0mm 2 Red plug VITM6L605100R 6 core 5m 1.0mm 2 Red plug Other leads available to order. Accessories Connectors VITM6-SELVMOD VITM-ROSE SELV dimming switch module Ceiling rose module VITM6-LPW VITM6-LPR 6 pole luminaire plug white 6 pole luminaire plug red Ratings Voltage 230VAC +/- 10% Frequency 50Hz Terminal capacity 4mm 2 in wiring compartment Temperature 0ºC to 35ºC Power Rating of system 16A. Rating of each output 10A VITM6-SELVMOD control of up to 20 ballasts Compliance BS 5733:1995 For lighting purposes only with suitable circuit protection. For fixed wiring only Patent pending EU registered design no. 000638069-0003, 00638069-0004 IMPORTANT NOTICE! This device should be installed by a qualified electrician in accordance with the latest edition of the IEE wiring regulations. FM 45789 EMS 534520 Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior notice. 8 C.P. Electronics Ltd Brent Crescent London NW10 7XR United Kingdom Tel: + 44 (0) 333 900 0671 Fax: + 44 (0) 333 900 0674 www.cpelectronics.co.uk enquiry@cpelectronics.co.uk Ref: #WD290 Issue 3