ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

Similar documents
Ultra-Safe EXP Unit Heater

ULTRA-SAFE Explosion-proof Duct Heaters

FX5 Series Explosion-Proof Electric Air Heaters

ULTRA-SAFE Explosion-proof Duct Heaters

FE1 Explosion-Proof Electric Air Heaters

Comfort. Description. Applications

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

Brasch Hazardous Location Unit Heaters

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Explosion-Proof Forced Air Unit Heater - XGB

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Explosion-Proof Forced Air Unit Heater - XGB

Description. Applications

CR1 Series Triton Corrosion Resistant Washdown Heaters

Description. Applications

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

HLA Series Hazardous Location Fan Forced Unit Heater

Description. Construction

HLA Series Hazardous Location Fan Forced Unit Heater

KUH. Horizontal Unit Heater. Applications. Description

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

Thermal Devices, Inc. Mount Airy, Maryland USA

Industrial Air Heaters

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

EXH Series Explosionproof Electric Air Heaters

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

MAC N-407 Air-Cooled Chiller

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

Type UB-2502A and UB-3002A Forced-Air Heater

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Custom Duct Heaters. Special Applications

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

Electric Unit Heaters

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION AIR COILS

CX1 ProVector Explosion-Proof Heaters

MACH N-407 Heat Pump Air-Cooled Chiller

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CXH-A Forced-Air Heater

FX5 SD Series Electric Forced Air Heaters for Hazardous Locations

Tubular Industrial Process

1.1 This section applies to air handling units for HVAC Systems.

SECTION ROTARY-SCREW WATER CHILLERS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

MAC-120HE-03 Air-Cooled Chiller

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

CF1 ProVector Explosion-Proof Heaters

Product Specifications. Vertical Floor Consoles By First Co.

Portable Vertical Air-Conditioning and Heating Systems

240 Series Unit Heater SameDay Shipping


Product Chillers A P P L I C AT I O N S

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Call us today! (800)

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

SECTION AIR DOORS

Custom Duct Heaters. Special Applications

SECTION (15767) - UNIT HEATERS

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

30GT FLOTRONIC AIR-COOLED CHILLERS

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

TECHNICAL SPECIFICATIONS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

PACKAGE AIR CONDITIONER

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

HD3D Forced-Air Heater

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

Tubular Industrial Process

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Why settle for anything less?

30GN FLOTRONIC II AIR-COOLED CHILLERS

EMI ENGINEERING SUBMITTAL

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

FE2 Series. Installation, Operation, & Maintenance Instructions. Electric Forced Air Heaters for Hazardous Locations. Model Coding

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

SECTION COOLING TOWERS

ELECTRIC UNIT HEATER REGULAR DUTY

STEAM/HOT WATER UNIT HEATERS

ELECTRIC UNIT HEATERS FOR STANDARD AND HAZARDOUS (CLASSIFIED) LOCATIONS

Explosion-proof Duct Heaters

Direct Gas-Fired Make-Up Air

SECTION AIR COOLED WATER CHILLERS

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

Call us today! (800)


Transcription:

ULTRA-SAFE EXP U N I T E X P L O S I O N - P R O O F S Applications Aircraft Hangars/Service Areas hemical Storage/Handling Areas oal Preparation Plants ompressor Stations Grain Elevators Oil Refineries and Rigs Paint Storage Areas Petrochemical Plants Sewage Pump Stations/ Treatment Plants Spray Booths lass I, Divisions and, Groups and D lass II, Divisions and, Groups E, F and G lass I, Zones and, Group IIB Temperature ode T, 0 F (60 ) INDEEO s ULTRA-SAFE EXP explosion-proof unit heater is designed with both safety and versatility in mind. Unique ULTRA-SAFE EXP features include: Industry s Lowest Ignition Temperature ode Rating: T, 0 F (60 ) Dual Overtemperature Protection: With both automatic and manual reset overtemperature cutouts for additional safety. Nontoxic Propylene Glycol Heat Transfer Fluid Low 70 PSIG Relief Valve Setting: This assures that in an emergency, the initial escaping vapor temperature remains below the 0 F (60 ) ignition temperature. orrosive Resistant Options: INDEEO offers three constructions suitable for most applications. Standard construction for use in dry non-corrosive areas includes: welded steel heat exchanger; powder-coated cabinet; epoxy-coated motor. A 6 stainless steel construction suitable for Waste Water Treatment Plants includes: 6 stainless steel heat exchanger, headers and tubes with aluminum fins; stainless steel cabinet; corrosive resistance hardware; epoxy-coated motor. Third construction is suitable for use in hemical Plants where chlorides are present and includes: Heresite coated heat exchanger, cabinet, fan blade; corrosive resistance hardware; epoxy-coated motor. Standard onstruction Features Heat Exchanger Efficient liquid-to-air design utilizes an all welded steel headers and finned tube construction with spiral wound aluminum fins. Industrial grade INDEEO heating elements are immersed in a nontoxic, inhibited, propylene glycol heat transfer fluid that provides freeze protection down to -49 F (-45 ). The heat exchanger is hydrostatically tested at 50 psig. A pressure relief valve provides excess pressure protection and is set at 70 psig. Fan Motor Assembly onsists of an explosion-proof motor fitted with an aluminum fan blade. The motor has double-shielded, permanently lubricated ball bearings and automatic reset line breaking thermal overload protection. Motors furnished on standard units operate at line voltage and are prewired to the control enclosure so separate field wiring to the motor is not required. The standard motor is rated for lass I, Groups and D, lass II, Groups F and G. The minimum operating temperature is -4 F (-5 ) and the minimum storage temperature is -49 F (-45 ). Optional motor ratings are described on page 9. abinet/louvers Industrial grade, corrosion resistant construction fabricated from powder coated 4-gauge galvanized steel. The adjustable louvers have minimum opening safety stops. ontrols Factory mounted on the unit heater. Standard built-in controls include automatic and manual reset overtemperature cutouts, controlling magnetic contactor, 4-volt control circuit transformer and incoming power terminal blocks housed in a NEMA 7, 9 cast aluminum enclosure. 8 800-4-86

U N I T ULTRA-SAFE EXP Factory Built-in Options ode Option Description D E H 6 Stainless Steel orrosion Resistant onstruction (Waste Water Treatment Plants) Dirty Duty orrosion- Resistant onstruction (hemical Plants) Disconnect Switch Group E (Metal Dust ) onstruction 50 Hertz Motor 6 Stainless steel heat exchanger with aluminum fins, 6 stainless steel cabinet; aluminum fan blade; cast aluminum NEMA 4X, 7, 9 control enclosure; corrosionresistant hardware; corrosion-resistant protective coated motor which has passed the TM B7 salt-spray test. Epoxy-coated motor; Heresite coated heat exchanger cabinet and fan blade; cast aluminum NEMA 4X, 7, 9 control enclosure; corrosion resistant hardware; corrosionresistant protective coated motor which has passed the TM B7 salt-spray test. Factory installed on the unit heater beside the control enclosure. This is an inexpensive and positive way to meet NE/E requirements for a disconnecting means within sight of the heater. lass II, Group E (Metal Dust) onstruction Temperature ode T, 0 F (60 ) Optional motors for international requirements. ontact factory for KW availability. ode () S E X P L O S I O N - P R O O F S K "Warning" Pilot Light Indicates when the thermal cutouts have tripped and the unit heater needs servicing. L "Heater On" Pilot Light Indicates when the electric heating elements are energized. M Manual Reset Thermal utout with Backup ontactor A pilot duty manual reset thermal cutout with a backup contactor is provided for independent secondary overtemperature protection. This option cannot be provided if option ode S or V are also specified. S Auto/Fan Selector Switch A two-position switch wired to the control circuit for auto (automatic heat) and fan only control. This selector switch cannot be provided if option ode M or V are also specified. T Adjustable Thermostat Factory installed and prewired to the control enclosure. Thermostat is adjustable from 50 to 90 F (0 to ) range. S V 0 Volt ontrol ircuit an be provided when required for special external thermostat circuit. This option cannot be provided if option ode S or M are also specified. Nor can both K and L be specified. () S = Stock, = Assembly Stock, = ustom Stock heaters ordered with assembly stock or custom options subject to longer delivery. 800-4-86 9

ULTRA-SAFE EXP U N I T E X P L O S I O N - P R O O F S Accessory Items ULTRA-SAFE EXP Heater Mounting Kits These are available for ceiling, wall and pole mounting configurations as described below. Specify type required and catalog number at time of order entry..5 (6.5) MH ULTRA-SAFE EXP Explosion-proof Unit Heater 6-/8" (59.76 mm) 5" (7 mm) ULTRA-SAFE EXP Explosion-proof Unit Heater MW 5" (7 mm) ULTRA-SAFE EXP Explosion-proof Unit Heater eiling Mounting Kit Wall Mounting Kit Pole Mounting Kit MW Size MH In. (mm).06 (8) 5.06 (8.6) 9.06 (484.) MW In. (mm) 9 (8.6) 7 (77.8) 5 (7) Unit Heater Mounting Kits (One kit required per heater) Mounting Kits for use with Standard Heater Powder oated onstruction atalog Number 045 045 0455 Description eiling Mounting Kit, for Frame Sizes,, Wall Mounting Kit, for Frame Size,, Pole Mounting Kit, for Frame Size,, Week Unit Heater Mounting Kits (One kit required per heater) Mounting Kits for use with Heaters which include optional orrosion Resistant odes and atalog Number 045-S 0454-S 0455-S Description orrosion Resistant eiling Mounting Kit, for Frame Sizes,, orrosion Resistant Wall Mounting Kit, for Frame Size,, orrosion Resistant Pole Mounting Kit, for Frame Size,, Week For corrosion resistant option, add - S to the end of item number. Remote Room Thermostat Use catalog number 00700. See page 95. 0 800-4-86

U N I T ULTRA-SAFE EXP Dimensions, Airflows and Weights Overall Heater Dimensions Airflow haracteristics Motor/Fan Weight KW Range X In. (mm) Y In. (mm) Z In. (mm) FM (M/Hr) Throw Ft. (m) RPM HP Fan Diameter In. (mm) Net Lbs (Kg) Shipping Lbs (Kg) Size Size Size -5 KW 7.5-0 KW 5 KW 0 KW 5 KW 0 KW 8.5 (46.55) 9.75 (49.5) 6.06 (408) 650 850 5 (4.5) 5 (7.6) /4 (04.8) 0 (49.89) 0 (58.96) 8.5 (46.55).75 (59.75) 0.88 (5.775) 800 45 (.7) 75 /4 6 (406.4) 50 (68.0) 69 (76.65) 0.00 (508) 7.75 (695.5) 4.88 (64.75) 0 850 65 (9.8) 75 (.8) / 0 (508) 90 (86.8) 6 (97.97) E X P L O S I O N - P R O O F S Y X Side View 6-/4" Z Front View 800-4-86

ULTRA-SAFE EXP U N I T E X P L O S I O N - P R O O F S ULTRA-SAFE EXP Unit Heater Listing KW 5 7.5 0 5 0 5 0 Volts Phase Total Amps () 7 5 0 9 5 4 6 6 4 7 6 8 4 0 0 9 44 0 6 44 8 9 6 5 5 7 0 Frame Size Approximate Air Temperature Rise F ( ) 5 (8) 5 (8) 5 (8) 5 (8) 5 (8) 5 (8) 5 () 5 () 5 () 5 () 5 () 5 () 8 (6) 8 (6) 8 (6) 8 (6) 8 (6) 8 (6) 8 () 8 () 8 () 8 () 8 () 7 (5) 7 (5) 7 (5) 7 (5) 5 (9) 5 (9) 6 (4) 6 (4) 5 () 5 () lass I, Divisions and, Groups and D lass II, Divisions and, Groups F and G lass I, Zones and, Group IIB Temperature ode T, 0 F (60 ) atalog Number -FA-006 -FA-006J -FA-006D -FA-006K -FA-006U -FA-006Z -FA-0056 -FA-0056J -FA-0056D -FA-0056K -FA-0056U -FA-0056Z -FA-0086 -FA-0086J -FA-0086D -FA-0086K -FA-0086U -FA-0086Z -FA-006J -FA-006D -FA-006K -FA-006U -FA-006Z -FB-056D -FB-056K -FB-056U -FB-056Z -FB-006U -FB-006Z -F-056U -F-056Z -F-006U -F-006Z Week () Total Amps = Heating element amps and motor amps. 800-4-86

U N I T Standard - Non-corrosive applications Aircraft Hangars/Servicing Areas oal Mines/Preparation Plants Gasoline Fueling/Storage Areas Paint Spraying/Storage Areas Utility Plants ULTRA-SAFE EXP Explosion-Proof Unit Heater Three onstructions to hoose From; Standard, Stainless Steel or Heresite Standard 4VA transformer ontactor Automatic and manual reset overtemperature thermal cutouts Heavy 4-Gauge abinet Powder coated - standard 6 stainless steel or Heresite coated - options Optional 6 Stainless Steel or Heresite oating hemical Plants hemical Storage/Handling Areas Food Processing Plants Oil Refineries Petrochemical Plants Sewage Treatment/Wastewater Treatment Plants Adjustable louvers Finger safe fan guard split construction for easy removal for field servicing. E X P L O S I O N - P R O O F S Optional Disconnect switch with lockout Fan selector switch Thermostat Thermally-protected explosion-proof motor with heavy-gauge aluminum fan blade designed for easy field servicing. Designed for Easy Servicing Removable core Split fan guard Easy access to motor and fan Replaceable automatic and manual thermal cutouts Threaded control enclosure Heater ore All welded construction with: Painted steel heaters with steel tubes and spiral wound aluminum fins - standard 6 stainless or heresite construction - options ore can be easily removed through bottom of cabinet Heresite is a registered trademark of Heresite Protective oatings, Inc. 800-4-86