ID3000 intelligent. fire alarm panel

Similar documents
ID3000 intelligent. fire alarm panel

ID2000. intelligent fire alarm panel

ID50series. intelligent fire alarm panels

intelligent fire alarm ID60series panels

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

ZXSe Range Data Sheet

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Different types of Fire Alarm System

The EN54 Part 2, 4 and 13 Fire System

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Advanced FireAlarm Panel 1-4Loop

Product Data Sheet. Remote Terminals. Features:

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

The EN54 Part 2 & 4 Fire System


SMALL SCALE SOLUTIONS

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Extending Your Potential. Product Range

System 800 Addressable Fire Detection & Alarm System

Intelligent Security & Fire Ltd

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

Components Brochure DX CONNEXION

Intelligent Single Loop Fire Alarm Control Panel

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

NETWORKING AND INTEGRATION

Intelligent 2 & 4 Loop Fire Alarm Control Panels

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

TrueAlarm Fire Alarm Systems

HART XL High Sensitivity Smoke Detection

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

DS7400Xi Addressable Control/ Communicator

Fire control panels FC726 FC726-XA

Consultant Specification AGILE Wireless Fire Detection System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

Intelligent Security & Fire Ltd

DRAFT 20 October 2014

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

DCS-100. intelligent damper control & monitoring system

SUPREMATouch. Modular Fire & Gas Detection System

Vigilant MX4428 Fire Alarm System

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

HART XL High Sensitivity Smoke Detection

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Building Technologies

ONYXWORKS AND FIRSTVISION. Version 4

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Input/Output Modules Data Sheet

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Fire control panels FC360

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

Addressable Fire Alarm Control Panel

CSP-204 CSP-208 CSP-104 CSP-108

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Planning Instructions MEW01472 Revision -

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

For Complete Fire and Gas Solutions

FireClass. Introducing a new class of fire detection

INTELLIGENT FIRE ALARM CONTROL PANEL

Flair 500 Series Annunciators

TrueAlarm Fire Alarm Controls

Laptop / PC Programming Manual

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

Analogue Addressable Fire Panel Range

AUTOCALL FIRE DETECTION SYSTEMS.

ID2000. operating manual

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Reliably Advanced Extinguishing Control

Solution F2. Fire Alarm Control Panels one step ahead.

IQ8Control C Fire Alarm Panel

Intelligent addressable fire alarm control panel

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Installation, Operating and Maintenance Manual

SUPREMATouch. Modular Fire & Gas Detection System

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Reliably Advanced Extinguishing Control

Fire control panel detect 3004 plus and accessories

NETWORK FIRE ALARM CONTROL PANEL. Features

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Touchpoint Pro Flexible Gas Control System

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

JVA Electric Security Fence System. perimeter intruder detection system

Transcription:

ID3000 intelligent fire alarm panel

features introduction certified to EN54 parts 2 and 4 The NOTIFIER ID3000 intelligent fire alarm panel offers a technically sophisticated range of facilities and functions whilst remaining easy to install, program and operate. Modern styling and a variety of aesthetic options are sure to win over facility owners and architects. It has been 3rd party certified to the current EN54 standards part 2 and 4. expandable from 2 to 8 loop capacity up to 198 per loop (99 sensor and 99 modules) 255 fire zones per panel modular design supports NOTIFIER S advanced detection such as: VIEW OptiPlex HARSH Advanced design and manufacturing techniques coupled with NOTIFIER s 50 plus years of experience at the forefront of the fire industry, ensure that the ID3000 sets new standards in many areas such as product functionality, flexibility, user friendliness and reliability; in short everything you expect from the world leaders in modern life safety systems. system A full range of intelligent sensors, advanced detection products, input and output, repeaters, mimic drivers, printers and other peripherals complement the ID3000 to bring you the most complete and versatile fire alarm system in the market place. The ID3000 panels can be networked together either as a true peer to peer network or in a Master / Slave network, extending the total capacity of the system to fit the largest applications. The ID3000 is designed in a modular fashion to allow for a wide range of applications, facilitating installation and servicing whilst making the ID3000 very easy to tailor to the requirements of the application. The large LCD graphic provides easy to read and understand messages complying with the EN54 standard for primary user interfaces. The NOTIFIER ID3000 intelligent fire alarm panel is ideally suited for large facilities such as shopping malls, schools, office buildings, hospitals, hotels, factories and large warehouses. With its expansion capability the ID3000 provides control of 2 to 8 loops with each loop having a capacity of 198 (99 sensors and 99 modules). The modular design of the ID3000 allows the user to tailor the panel to their exact application requirements. Three sizes of power supplies are available (2.5A, 4.5A and 7A) to cater for the needs of small, medium and large systems. Internal and external printer options, a variety of mounting options and the optional loop and communication expansion modules all provide a high degree of flexibility during initial design with a ready-made expansion path for the future. HAZARD 9 levels of sensitivity Autolearn facility network option ID2net (Peer to Peer) Master/Slave programmable from the panel keypad or PC 240 x 64 pixel graphic LCD display degraded mode of operation variety of mounting options flexible time programming The 240 x 64 pixel graphic LCD combined with simple menu driven user interface bring full system monitoring and control functions at the fingertips of the system operator. The graphic LCD configuration The NOTIFIER ID3000 is a fully on-site programmable intelligent fire alarm panel. It can be programmed either from the panel keypad, or from a personal computer using the off-line configuration tool. An Auto-Learn facility allows the user to install and commission a standard system with the minimum of effort. A virtual keyboard on the LCD will allow the user to enter any text message or description from the panel. fully meets the mandatory requirements of EN54 for primary indications, however, if desired, zone status indicator LED s can also be added for up to 255 zones per panel to give the user additional status indicators. If a more complex Cause & Effect matrix is required the ID3000 may be programmed to meet individual site requirements by means of the powerful The ID3000 provides redundant processing exceeding the requirements of stringent EN54 requirements. In addition to a system microprocessor, each ELIB (Enhanced Loop Interface Board) is Control By Event (CBE) rules. Using CBE rules, site specific requirements such as plant shutdown, fire door control, smoke control, phased evacuation, point/zone isolation, point to output controls and many others can be independently controlled by a separate powerful microprocessor. In the event of a system failure the ELIBs continue to fully supply fire cover. Under the EN54 rules, detection point limit with the ELIB is 1584 point max per panel. programmed with relative ease. Devices can be grouped into a total of 255 zones per panel for control and monitoring purposes. Furthermore, the CBE rules can be initiated and combined through flexible time programs. The ID3000 can be programmed to compensate for the differences in the use of the areas where the smoke sensors are utilised. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensor s response to the environment in which the device is located. Using time programs, different sensitivity settings can be selected at different times of the day. For example, to avoid false alarms, smoke sensor sensitivity can be lowered during the day when a meeting room is likely to be used by smokers and set back to a high sensitivity during the night time when the premises are unoccupied. System security and integrity is an important aspect of the ID3000. The cover of the ID3000 cannot be removed without a special tool and an optional tamper switch can be installed to protect against unauthorised cover removal. Furthermore, two levels of Password protection makes it virtually impossible for unauthorised people to access the panel and its manual controls and change system configuration. Alternatively the key-switch can be used to enable/disable level 2 access. All configuration data is retained in non-volatile memory and is, therefore, protected against complete failure of the power supply.

features introduction certified to EN54 parts 2 and 4 The NOTIFIER ID3000 intelligent fire alarm panel offers a technically sophisticated range of facilities and functions whilst remaining easy to install, program and operate. Modern styling and a variety of aesthetic options are sure to win over facility owners and architects. It has been 3rd party certified to the current EN54 standards part 2 and 4. expandable from 2 to 8 loop capacity up to 198 per loop (99 sensor and 99 modules) 255 fire zones per panel modular design supports NOTIFIER S advanced detection such as: VIEW OptiPlex HARSH Advanced design and manufacturing techniques coupled with NOTIFIER s 50 plus years of experience at the forefront of the fire industry, ensure that the ID3000 sets new standards in many areas such as product functionality, flexibility, user friendliness and reliability; in short everything you expect from the world leaders in modern life safety systems. system A full range of intelligent sensors, advanced detection products, input and output, repeaters, mimic drivers, printers and other peripherals complement the ID3000 to bring you the most complete and versatile fire alarm system in the market place. The ID3000 panels can be networked together either as a true peer to peer network or in a Master / Slave network, extending the total capacity of the system to fit the largest applications. The ID3000 is designed in a modular fashion to allow for a wide range of applications, facilitating installation and servicing whilst making the ID3000 very easy to tailor to the requirements of the application. The large LCD graphic provides easy to read and understand messages complying with the EN54 standard for primary user interfaces. The NOTIFIER ID3000 intelligent fire alarm panel is ideally suited for large facilities such as shopping malls, schools, office buildings, hospitals, hotels, factories and large warehouses. With its expansion capability the ID3000 provides control of 2 to 8 loops with each loop having a capacity of 198 (99 sensors and 99 modules). The modular design of the ID3000 allows the user to tailor the panel to their exact application requirements. Three sizes of power supplies are available (2.5A, 4.5A and 7A) to cater for the needs of small, medium and large systems. Internal and external printer options, a variety of mounting options and the optional loop and communication expansion modules all provide a high degree of flexibility during initial design with a ready-made expansion path for the future. HAZARD 9 levels of sensitivity Autolearn facility network option ID2net (Peer to Peer) Master/Slave programmable from the panel keypad or PC 240 x 64 pixel graphic LCD display degraded mode of operation variety of mounting options flexible time programming The 240 x 64 pixel graphic LCD combined with simple menu driven user interface bring full system monitoring and control functions at the fingertips of the system operator. The graphic LCD configuration The NOTIFIER ID3000 is a fully on-site programmable intelligent fire alarm panel. It can be programmed either from the panel keypad, or from a personal computer using the off-line configuration tool. An Auto-Learn facility allows the user to install and commission a standard system with the minimum of effort. A virtual keyboard on the LCD will allow the user to enter any text message or description from the panel. fully meets the mandatory requirements of EN54 for primary indications, however, if desired, zone status indicator LED s can also be added for up to 255 zones per panel to give the user additional status indicators. If a more complex Cause & Effect matrix is required the ID3000 may be programmed to meet individual site requirements by means of the powerful The ID3000 provides redundant processing exceeding the requirements of stringent EN54 requirements. In addition to a system microprocessor, each ELIB (Enhanced Loop Interface Board) is Control By Event (CBE) rules. Using CBE rules, site specific requirements such as plant shutdown, fire door control, smoke control, phased evacuation, point/zone isolation, point to output controls and many others can be independently controlled by a separate powerful microprocessor. In the event of a system failure the ELIBs continue to fully supply fire cover. Under the EN54 rules, detection point limit with the ELIB is 1584 point max per panel. programmed with relative ease. Devices can be grouped into a total of 255 zones per panel for control and monitoring purposes. Furthermore, the CBE rules can be initiated and combined through flexible time programs. The ID3000 can be programmed to compensate for the differences in the use of the areas where the smoke sensors are utilised. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensor s response to the environment in which the device is located. Using time programs, different sensitivity settings can be selected at different times of the day. For example, to avoid false alarms, smoke sensor sensitivity can be lowered during the day when a meeting room is likely to be used by smokers and set back to a high sensitivity during the night time when the premises are unoccupied. System security and integrity is an important aspect of the ID3000. The cover of the ID3000 cannot be removed without a special tool and an optional tamper switch can be installed to protect against unauthorised cover removal. Furthermore, two levels of Password protection makes it virtually impossible for unauthorised people to access the panel and its manual controls and change system configuration. Alternatively the key-switch can be used to enable/disable level 2 access. All configuration data is retained in non-volatile memory and is, therefore, protected against complete failure of the power supply.

networking The ID 2 net (Intelligent Digital Delivery Network) from NOTIFIER is truly a quantum leap in fire networking technology. It has been developed to exceed international requirements and to set new industry standards in the areas of speed, reliability, robustness and flexibility. ID 2 net the network of tomorrow, today. The ID 2 net functions without burdening the attached fire panel and peripherals. In fact, since the attached fire panels are removed from all networking responsibilities, they perform faster and are 100% fully dedicated to advanced alarm detection and alarm processing. Each network gateway module on the ID 2 net has an on-board powerful microprocessor responsible for the network integrity, including fault detection, message integrity, priority messaging, supervision, confirmed delivery messaging, high speed transfer and diagnostics. The ID 2 net enables the use of up to 100 nodes, with up to 32 networked ID3000 eight loop fire alarm panels. This provides an astounding system capacity of 50,688 addressable points, (25,344 smoke detectors, 25,344 input and/or output modules and/or loop powered sounders), 8160 network zones, and up to 170 km of network cabling. Furthermore, the ID 2 net supports fibre optics; simply connect the NOTIFIER fibre optic card to the network gateway module and a mixture of wire cable and fibre optic cable can be applied if desired. Detection and recovery mechanisms from open and short circuits, as well as earth faults, are totally reliable and exceed the EN-54. Each communication path between nodes are electrically isolated, so that no ground loop problems exist. Digital based communications offers added levels of noise immunity even in the harshest, noisiest environments. True peer to peer performance is provided in many ways. Because of the ultra high speed of the ID 2 net, the network appears to be invisible. A very large network has the feel of one single fire panel. Complex CBE (Control by Event) configured and integral to each attached fire panel, can travel across the network at speeds so high they allow multiple decisions by multiple panels in the blink of an eye. This opens tremendous possibilities in varied real world applications never before thought possible. In the event of multiple network faults, as with an open or short circuit between nodes, mini networks are established and continue to function as normal. For example, in the case of an open circuit between buildings and on the connecting ring in the other direction, the panels inside each building continue to communicate with one another and any CBE between them operates as intended. Up to 1.7km* Copper conductor cable Up to 1.7km* Copper conductor cable Loop 1 Loop 1 Loop 1 Up to 3km Fibre-optic cable Up to 32 panels or 100 nodes Copper conductor or Fibre-optic cables Loop 1 Copper conductor cable Loop 1 Fibre-optic cable Up to 1.7km* Up to 3km*

master/slave network The ID3000 Master/Slave network is an RS485 serial data link and can support up to 32 network stations. Up to a maximum of 8 stations can be ID3000 panels with the rest being repeater and mimic driver stations. The network supports general control functions such as Reset, Silence, Mute, Evacuate and more specific functions such as Point/Zone Isolate, Walk Test, Zone Event Broadcast and Control by Event (CBE) across the network. Full system monitoring and control is easily achieved from the Master control panel. The ID3000 Master/Slave network remains compatible with NOTIFIER s ID1000 and ID2000 intelligent control panels. However, as the ID1000 and ID2000 do not support all of the functionality offered by the ID3000, the network will be limited within the ID1000 and/or the ID2000 functionality. ID3000 Series Panel ID3000 Series Double Extended Panel ID3000 Series Extended Panel IDR-6A Repeater Panel Call Point OptiPlex VIEW Sensor VIEW Sensor Heal Sensor Control Relay Output Door Holder (Externally Powered) Optical Sensor Duct Sensor Beam Detector (Loop Powered) HARSH Sensor Sounder Control Unit Short Circuit Isolation Module Call Point Ionisation Sensor Loop Powered Sounder Conventional Detector Interface Loop Powered Sounder Base and Sensor Loop Powered Sounder Base and sensor Beam Detector (Externally Powered) Conventional Detectors

mounting options A wide variety of mounting options is available with the ID3000. The basic back-box options (standard, single extended and double extended) with matching bezels lend themselves to surface mounting and flush mounting alike. A full range of 19-inch rack mounting assemblies address the needs of more industrial type installations. As with all other ID series intelligent fire alarm panels from NOTIFIER, the ID3000 comes in the Black/Grey NOTIFIER colour as standard. A light grey cover and bezel option with a high quality velvety finish and a stainless steel cover and bezel option with clean bright looks are also available for more architecturally challenging sites. In areas where visibility is important or where local codes require the full range of back-boxes, covers and bezels are also available in red. The modular 19-inch rack mounting range combines the industrial versatility of 19-inch rack mounting with the aesthetically pleasing looks of the ID series panels. A combination of 3U and 6U size mounting assemblies is available for the various modules. repeater and mimic driver The IDR Series repeaters and mimic drivers complement the ID Series intelligent fire alarm panels. By placing repeaters and/or graphical mimic display panels at strategic points in the facility such as nurse stations, floor landings, gatehouse or control rooms valuable time can be saved when identifying the location of a fire and/or evacuating the building. The repeaters also provide additional system control and monitoring positions for the system users. The IDR6A Active Repeater Panel combines a compact design with a 240 x 64 pixel graphics LCD, system control buttons in surface or flush mounting options. The large LCD replicates the display on the ID3000 panel and utilises the same simple menu driven user interface as the ID3000 panel. The control buttons and navigation keys on the repeater provide the operator with the ability to navigate through menu options and event displays. Furthermore it allows the user to remotely reset the system, acknowledge events, silence sounders, resound sounders, initiate evacuation and to TO THE NEXT MIMIC CONTROLLER. UP TO 31 CONTROLLERS CAN BE CONNECTED A = MIMIC CONTROLLER B = MIMIC DRIVER C = MIMIC TERMINATION run diagnostics tests on the repeater. For security, a key switch on the front of the repeater enables function keys. The mimic is a highly versatile product that allows tremendous flexibility in configuring large numbers of system status LED s, relays and programmable digital inputs. Up to 31 mimics can be attached to the ID3000 via an RS485 communication link. Utilising the maximum capabilities of a full array of 31 mimics, 15872 LED s or relay driven outputs, 1736 high current outputs and 248 digital inputs are available. Each mimic consists of a microprocessor based mimic control board and up to 8 flexible driver boards. Each driver board provides 64 LED or low current relay drivers, 8 high current driven outputs and 8 programmable digital inputs typically used for Mute, Lamp Test, Enable, Reset, Silence or other. Termination boards are also available to simplify wiring of LED s relays and other to each driver board

graphical display and control system UniNet-ID SOLUTIONS The ID3000 is fully compatible with the UniNet-ID graphics system. This will allow up to two hundred ID3000 systems to be connected to a single UniNet-ID server. Up to 10 servers may also be networked together using standard TCP/IP providing a single system gateway to a large ID3000 system. The ID3000 plug-in provides the user complete control over all points in the system and includes: Acknowledge, Silence, Resound, Reset, Disable Zone, Enable Zone, Disable Device, Enable Device, Test Zone, Terminate Test & Evacuate. The UniNet-ID will also allow a combination of these functions to be added together in a Macro. This will allow the systems provider to customise the workstation to provide functions such as disable multiple plant shut downs from a single push button. All functions may be disabled at various levels of security access. The workstation uses Microsoft Windows 98, providing an easy to use and learn graphical user interface. The operator is presented with a consistent look and operation for all monitored equipment. The workstation features customisable screens and allows a wide variety of configuration options for any situation. UniNet-ID is the next generation in advanced technology to monitor and control fire and other facility information over a LonWorks network. The LonWorks network supports a variety of network topologies and media (wire, fiber-optic, etc.) and is an industry standard open architecture. The UniNet-ID Workstation Software is the operator interface to the UniNet- ID System. The workstation features standardised plug-in applications, allowing continued expansion of workstation and network functions. These applications can add new features to the software, implement features specific to certain, or even add situation and facility specific features.

NOTIFIER international offices UK AUSTRALIA BENELUX BRAZIL CANADA CHILE CHINA GERMANY HONG KONG INDIA ITALY JORDAN LEBANON MEXICO POLAND RUSSIA SINGAPORE SOUTH AFRICA SPAIN SWEDEN USA VENEZUELA Charles Avenue Burgess Hill W. Sussex RH15 9UF T: +44 (0) 1444 230 300 F: +44 (0) 1444 230 888 E: sales@notifierfiresystems.co.uk www.notifierfiresystems.co.uk local distributor Every care has been taken in the preparation of this data sheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. available only from your NOTIFIER Engineered System Distributor Ref: 436(1004).