Installation & Maintenance Instructions SEPREMIUM 350. Oil /water separator 05/09

Similar documents
ENGLISH. Installation & Maintenance Instructions

NEVER CHANGE ORIGINAL COMPONENTS WITH ALTERNATIVES.

Operating Instruction. Condensate separator CC 35

SEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30

Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08

Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09

The PURO GRAND Condensate Cleaner Installation instructions: Maintenance instructions:

Series 57 WATER/OIL SEPARATORS

the condensate management specialist PURO-CT Sustainable Condensate Management CONDENSATE SEPARATORS

The PURO Condensate Cleaner Installation instructions. Maintenance instructions:

Air treatment solutions. Aftercoolers & condensate treatment

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

EV-PRO CONDENSATE SEPARATORS

DS Series. Ultraaqua Autoclean. Oil/Water Separators

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance.

ES2000 Series. Oil / Water Separators ENGINEERING YOUR SUCCESS. mb air systems ltd

ADSORPTION DRYERS. For all applications which require perfectly dry compressed air : Advantages of "ALC" dryers :


Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

CPP condensate separator series. High-performance products. Designed for you!

Condensate Management. Condensate Purifiers Condensate Drains

Kompressoren. Oil Water Separators OWS

Operating Manual Oil Water Separator CSD3 - CSD160 Version: 12/2013/DE

Instruction manual ASPIMAX 16

Air Dryers & After Coolers Dry Land

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

AeroVent 1 Product Manual

Model OP155 Air Dryer

the responsibility is yours!

Installation Instructions AS-WH Whole House Water Filter

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

CONDENSATE MANAGEMENT

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

ES2000 Series Oil/Water Separators. The responsible way to remove and dispose of oil contaminated compressor condensate

Leading Innovation in Compressed Air Treatment CTS SERIES ELIMINATOR II OIL WATER SEPARATORS

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

MODEL 7000 SUCTION UNIT

Xaact Spot. Xaact Hot Spot

Operating Instructions

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 14 DEC NOVATEC, Inc All Rights Reserved

SUN EQUINOX HEATING SYSTEMS

AeroVent 3X Product Manual

Chapter 9: The basics of air preparation

Operation and Maintenance Manual

Oil / Water Separators Ultrasep Superplus N and Ultraaqua Autoclean

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

RENNER SCREW COMPRESSORS WATER-INJECTED 100% OIL-FREE COMPRESSED AIR Made in Germany

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

PRE-INSTALLATION PROCEDURE

domnick hunter PNEUDRI DME012-RX - DME080-RX USER GUIDE Original Language

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART

AeroVent Standard Product Manual

PRE INSTALLATION PROCEDURES

CARE AND USE GUIDE VACUUM INSULATED HYDRATION BOTTLE

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual

CARE AND USE GUIDE UNDER ARMOUR HYDRATION BOTTLES

7165 Dust Collector Owner s Manual

HIGH QUALITY COMPRESSED AIR FROM GENERATION TO APPLICATION A GUIDE TO THE ISO 8573 AND ISO SERIES OF COMPRESSED AIR QUALITY STANDARDS

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

LEVEL SENSED DRAINS KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP 50 KAPTIV-CS-HP 500 NUFORS-CR MAGY-UL

Menumaster. Commercial Microwave Oven Use and Care Manual CFSP70 GSAND-7D SAND-7D SAND-700

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

CHH30 Dishwasher. Wiring Diagram. Spare Parts List. Installation / Operation

USER MANUAL. Electric Open Well Steam Tables. Models: 423EST2WE, 423EST3WE, 423EST4WE500, 423EST4WE750, 423EST5WE

ÖWAMAT. National technical approval Z Deutsches Institut für Bautechnik, Berlin

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

A few simple steps to ensure perfect water, every time.

OIL-WATER SEPARATORS. GD PAK Series

RK/ RK Carbon Monoxide Detector Operator s Manual

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

5HP CYCLONE DUST COLLECTOR MANUAL

Compressed air preparation Compressed air storage Moisture management. Catalog #1

WATER, OIL, CONTAMINANTS: SEPARATION AND EVACUATION

METPOINT OCV. e. g. SAFE PROCESS THROUGH MONITORING. FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals. Food Chemical Coating

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

Technical Manual Binair Monobloc Heat Pump

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic)

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Service package PDAD- -SP (en) Assembly instructions d [ ]

Atlas Copco. Condensate management. OSC & OSD Oil/water separator series

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

RK/ RK Oxygen Detector Operator s Manual

Instruction Manual. Automatic fuel oil de-aerator SMART-FLO 3/K B100 COMPATIBLE

DESICCANT AIR DRYERS. BD + CD + CD series

Recycling Equipment for Processing recycled Refrigerators

2-Stage Under Counter Filtration System Model: WP-2 LCV

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

ED3002 ED3004 ED3007 ED3030 ED3100

RK Carbon Monoxide Transmitter Operator s Manual

Transcription:

Installation & Maintenance Instructions SEPREMIUM 350 Oil /water separator GENERAL OPERATION 05/09 The SEPREMIUM range of oil/water separators separates oil from condensate, generated by compressed air systems. The SEPREMIUM achieves separation of oil from condensate by means of directing the condensate through various separation stages. As condensate flows in to the SEPREMIUM, the oil is filtered out through various filtration elements. The first oil adsorbing element has a clever saturation indicating feature, offering you a visual operating status of the separator at a distance. The elements are designed to combine various types of adsorption technologies to achieve less than 10 ppm oil residue values at the output stage. Final separation stage includes specially selected activated carbon to polish out the remaining contaminants. 1

SAFETY INSTRUCTIONS SAFETY AND PROPER USAGE To ensure safe and enduring performance of this product, you must comply strictly with the instructions enclosed herein. Non-compliance with instructions or improper handling of the product will void your warranty! Usage of this product in conditions not specified in this manual or in contrary to the instructions hereby provided is considered IMPROPER. The manufacturer will not be held liable for any damages resulting from improper use of the product. SAFETY & WARNING INSTRUCTIONS ATTENTION - Observe valid and generally accepted safety rules when planning, installing and using this product. - Take proper measures to prevent unintentional operation of the product or damage to it. - Do not attempt to disassemble this product or lines in the system while they are under pressure. - Always depressurise the compressed air system before working on the system. It is important that personnel use safe working practices and observe all regulations and legal requirements for safety when operating this product. When handling, operating or carrying out maintenance on this product, personnel must employ safe engineering practices and observe all local health & safety requirements & regulations. International users refer to regulations that prevail within the country of installation. Most accidents, which occur during the operation and maintenance of machinery, are the result of failure to observe basic safety rules or precautions. An accident can often be avoided by recognising a situation that is potentially dangerous. Improper operation or maintenance of this product could be dangerous and result in an accident causing injury or death. The manufacturer cannot anticipate every possible circumstance, which may represent a potential hazard. The WARNINGS in this manual cover the most common potential hazards and are therefore not all-inclusive. If the user employs an operating procedure, an item of equipment or a method of working which is not specifically recommended by the manufacturer he must ensure that the product will not be damaged or made unsafe and that there is no risk to persons or property. 2

EXPLODED VIEW AND IDENTIFY ALL COMPONENTS DIAGRAM Element indicator Lid 1 Inlets (2x) Overflow indicator Test bottle Lid 2 Indicator element Depressurising foam Inner depressurising foam Static white element Black element Outlet Private label area Screws (3x) SEPREMIUM 350 housing Test drain Supporting bracket Service drains (2x) 3

INSTALLATION INSTRUCTIONS IMPORTANT NOTICE 1. Unpack the unit and visually inspect for any transport damage incurred after leaving our factory. Before installing this product, make sure it complies with your request and that it suits your application! 2. Depressurise the system before installation or maintenance is carried out! 3. Locate a suitable point in your compressor room to place your SEPREMIUM 350. This point must be near a suitable sewage point. The unit is designed to easily fit against a wall. 4. Remove both lids. Condensate collection pipe 4

INSTALLATION INSTRUCTIONS 5. Remove the plastic bag which is placed on top of the static white element inside tower 2. 6. Remove both white elements. 7. Connect the condensate collection pipe to the inlet s of the SEPREMIUM 350. 8. Connect the outlet from the SEPREMIUM 350 to a suitable sewage point. Make sure the condensate always flows down! 9. Before filling the unit with water make sure that the test drain and service drains are closed. 10. Fill the unit with water from tower 1 until both towers are filled and water flows out of the outlet point. Water level Tip: spraying water over the black element in tower 2 before filling the housing prevents carbon dust from spreading. 5

INSTALLATION INSTRUCTIONS 11. Make sure the black element rests on the bottom of tower 2 by pushing it down. 12. When both towers are filled with water and the black element rests on the bottom of tower 2 you can replace both white elements. White indicator element in tower 1 and white static element in tower 2. (Push the element down untill all the trapped air has escaped out of the element). 13. Replace both lids. (Lid 1 on tower 1 and lid 2 on tower 2). The white static element will be pushed in place by lid 2. 14. Your SEPREMIUM 350 is ready for operation. Make sure both lids are placed and secured properly. 6

SERVICE INSTRUCTIONS When your SEPREMIUM 350 requires maintenance (replacement of elements) please refer to our dedicated maintenance instructions (supplied with the SEPREMIUM 350 element service kit). SERVICE CHART Date Description Name 7

TECHNICAL SPECIFICATIONS Max. oil adsorption element s Approx. 2.6 Gallons US (10 Liter) Inlet connections ½ (2x) Outlet connections 1 Test valve Service drains (2x) Element life indicator Overflow indicator Housing material PE Total recyclable Housing color Black Lid color Grey Mineral lubricants Synthetic lubricants Stabile condensate emulsions Polyglycol Max. compressor capacity (consult factory) 350 cfm (10 m³/min) (based on a 8h. shift) DIMENSIONS (MM) 650 240 750 8