User s Manual for FT SERIES THE

Similar documents
Mascot LX. User s Information for. Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH

200i User s information manual

Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

APEX CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

- Do not store or use gasoline or other

USER'S INFORMATION MANUAL ES2 GAS - FIRED

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

VSL Boiler DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER HOT WATER MODEL VSL II 90A - 250A GAS-FIRED BOILER FOR NATURAL AND L.P.

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

iq251, Gen II Operation & Installation Manual WARNING AVERTISSEMENT

Installation and Operation Instructions Document 1320 MASCOT FT

OPERATOR S MANUAL for MANUAL (OPL) COMPACT DRYER

Installation and service must be performed by a qualified service installer, service agency or the gas supplier.

PowerMax TM. Installation and Operation Instructions for. Pool Heater. Model PM

SERIES PSCII GAS BOILERS

OPERATOR S MANUAL For DTCH55 Series Dryers

BruteTM. User s Manual for. Modulating Boiler Model BNTH Sizes MBTU/h. Water Heater Model BNTV Sizes MBTU/h. with Touchscreen Display

375 LP OWNERS MANUAL Aqua-Hot Heating Systems Inc.

Condensing, High Efficiency Water Heaters (IW) and Boilers (IB) R00 Feb. 18, 2014 UMIE

Installation and Operation Instructions NEOTHERM

NeoTherm. Installation and Operation Instructions. Modulating Boiler Model NTH. Sizes MBTU/h

Installation and Operation Instructions Document 2142

Dexter Laundry, Inc West Grimes Avenue Fairfield, Iowa 52556

Pennant. Installation and Operation Instructions. Hydronic Boiler Model PNCH Water Heater Model PNCV

Dexter Laundry, Inc West Grimes Avenue Fairfield, Iowa 52556

OPERATOR S MANUAL for DCT30KC/DLC30 Series Dryers

Rheos / Rheos+ Service Clearances May 21, 2009

Installation and Operation Instructions for

Installation and Operation Instructions Document 1266

TO DO IF YOU SMELL GAS

USER'S INFORMATION MANUAL

Operation Manual. Model: i200x i250x

Outdoor Tankless Water Heater Installation and Operation Manual

GRAVITY DIRECT VENT WALL FURNACE

USER'S INFORMATION MANUAL

EMPIRE INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL. Vented Slope Glaze Burner

Dexter Laundry, Inc W. Grimes Fairfield, Iowa USA

Vulcan Fire Module WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

PENNANT. Installation and Operation Instructions. Hydronic Boiler Model PNCH Water Heater Model PNCV Sizes

USER'S INFORMATION MANUAL

Tankless Water Heater

MASCOT FT. Installation and Operation Instructions

Keystone. Installation and Operation Instructions for. Condensing Boiler Model KS Sizes MBTU/h. Water Heater Model KW Sizes MBTU/h

FT SERIES Floor-Standing, Modulating Gas, Condensing, Combination Boiler Model MFTCF 140,000 BTU/hr 199,000 BTU/hr

Installation and Operation Instructions Document 1230

Brute Elite. Installation and Operation Instructions. Modulating Boiler Model BNTH Sizes MBTU/h. Water Heater Model BNTV Sizes MBTU/h

USER'S INFORMATION MANUAL

MASCOT II. Installation and Operation Instructions. Wall-Mounted Modulating Boiler Model LMH 125 MBTU/h

installation manual DM3862 RM2554 DM2663 RM2551 Refrigerator for LP-gas & electric operation DM2852 ! AVERTISSEMENT ! WARNING FOR YOUR SAFETY

USER'S INFORMATION MANUAL

AVERTISSEMENT. FiRE OR EXPLOSION RISQUE D'INCENDIE OU D'EXPLOSION

WARNING WARNING WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. WARNING

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

ML-78 Installation Manual Phase 7 / Dual Timer / F.S.S.

ML-82 Installation Manual Gas DSI / Steam Models / Phase 7 / Dual Timer Fire Suppression System

Boiler Manual Installation and Operation Instructions

AD-25/AD-30/AD-50 (Std. Phase 7 OPL/FSS/HSI) Installation Manual

WARNING / AVERTISSEMENT

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS EVSW SERIES MODULATING WATER HEATER

AD-24 Installation Manual Phase 5 / Gas DSI & Electric

Boiler Manual. Finned Copper Tube Gas Boilers (CB), & Water Heaters (CW) & Pool Heaters (CP) Installation and Operation Instructions

Marquis User s Manual

WARNING / AVERTISSEMENT

WARNING Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance. WARNING

Installation & Operating Manual

ML-75V Installation Manual

Boiler manual. Finned copper tube Gas boilers (CB), & Water heaters (CW) & Pool heaters (CP) Installation and operation instructions

FUTERA FUSION SERIES FINNED COPPER GAS BOILERS (MODEL CB) & WATER HEATERS (MODEL CW) INSTALLATION & OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

ML-190 / MLG-190DR Installation Manual

OPERATOR S MANUAL INSTALLATION & OPERATION INSTRUCTIONS The dryer must not be stored or installed where it will be exposed to water and/or weather.

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

CPFS DANGER. Installation and Operation Instructions Superior Outdoor Vent-Free Gas Fireplace. Models WHEN USED AS AN OUTDOOR APPLIANCE

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

MDG76PC (Phase 7.3 Coin Gas DSI) Installation Manual

ADG-78 II. Installation Manual

AD-50 Installation Manual

BruteTM. Installation and Operation Instructions. Modulating Boiler Model BNTH Sizes MBTU/h

ML-122 / MLG-122DR Installation Manual Phase 7 / Non-Coin / Dual Timer / F.S.S.

Operating instructions

USER S INFORMATION MANUAL

CELESTE/GEMINI 48/60/72

USER'S INFORMATION MANUAL

CAL-SERIES Specifications, Installation, Operation Service and Spare Parts Manual

CPFS DANGER WHEN USED AS AN OUTDOOR APPLIANCE. Installation and Operation Instructions. Outdoor Vent-Free Gas Fireplace With Refractory Panels

f i r e - p a r t s. c o m

ML-130 II. (HSI) Installation Manual

Installation & Operation Manual

WARNING AVERTISSEMENT HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.

/2010 US/CA

GBX GAS BOILERS USER S INFORMATION MANUAL

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

ML-78. (Gas/Electric/Steam) Installation Manual

WHEN USED AS AN OUTDOOR APPLIANCE

Service Procedures for the Model SL31-31 Dryer

Transcription:

User s Manual Document 1343D User s Manual for THE FT SERIES Wall-Mounted, Modulating Gas, Condensing, Heating Only, Boiler Model FTHW 80,000 BTU/hr 100,000 BTU/hr 120,000 BTU/hr 140,000 BTU/hr 199,000 BTU/hr Natural Gas (NG) - Factory Configuration Propane Gas (LP) - Field-Convertible FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, qualified in hot water boiler and heater installation and maintenance. Improper installation and/or operation could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death. Improper installation and/or operation will void the warranty. WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a nearby phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency, or gas supplier. AVERTISSEMENT Assurez-vous de bien suivres les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel, toute blessure ou la mort. Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil. QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ: Ne pas tenter d allumer d appareils. Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones dansle bâtiment où vous êtes. Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le sservice des incendies. L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz. H2375100D

Page 2 CONTENTS Pgs 1. Familiarizing yourself to the FT...2-3 2. Caring For Your FT...4 3. Start Up and Shut Down.....4 4. Control Setup and Operation...5-10 MODEL NUMBER 1. Familiarizing yourself to THE FT Heating Only Boiler 4 SCREWS The FT is a highly efficient, wall mounted, condensing and fully modulating, residential boiler. This Users Manual will guide you into the basics of operating your FT Please reference the Installation and Operation Manual for complete details. Doc # 1342 CONTROL DISPLAY COVER (HINGES UPWARD) NO Name of Component NO Name of Component 1 Air Vent (air eliminator) 17 CH Pressure Gauge 2 Air Intake Collar 18 CH Return Adapter 3 Air / Gas Mixing Pipe 19 Condensate Trap 4 Gas Inlet Pipe 2 20 Condensate Adapter 5 Gas Valve 21 CH Return Temperature Sensor 6 Exhaust Duct 22 Condensate Air Pressure Switch 7 Low Water Temperature Sensor 23 Terminal Block 8 OP Sensor 24 Heat Exchanger 9 Flame Detecting Sensor 25 Ignition Transformer 10 Main PCB 26 Sight Glass 11 Control Display 27 Burner Overheat Switch 12 Manual ON/OFF Power Switch 28 Igniter 13 Gas Inlet Pipe 1 29 BLDC Fan (blower) 14 CH Internal Pump 30 Exhaust Temperature Sensor 15 Gas Inlet Adapter 31 Air Pressure Sensor 16 CH Supply Adapter 32 Vent Pipe Collar

User s Manual - The FT, Heating Only, Boiler Page 3 Shown is the FT Heating Only 140 MBH. All sizes are very similar in component layout.

Page 4 2. Caring For Your FT Your FT will require very little maintenance. However, as with any fine appliance there are certain steps that should be taken to ensure continuing optimum performance. 2.1 General Care Keep the area around the FT clean and free from combustible materials, gasoline and other flammable liquids and vapors. The FT must be completely isolated and protected from any source of corrosive chemical fumes such as trichlorethylene, perchlorethylene, chlorine, etc. Keep bottom and top openings on the boiler free for proper ventilation of interior components. Do not obstruct or block a free flow of air to the boiler to ensure proper ventilation. If desired, clean the jacket surfaces with a damp cloth and mild detergent. Do not use flammable cleaning materials. If sidewall vented, keep the vent terminal clear of obstructions do not allow snow to cover the vent terminal. Clean the intake screen often, and then develop an appropriate maintenance schedule. 2.2 Annual Inspection of Flue and Vents Visually inspect the vent pipe once a year. Should any deterioration exist, have the affected parts replaced by a qualified service person. 2.3 In the Event of a Power Failure The FT can not be operated during an electrical power outage. If there is an extended power outage with danger from freezing, then the FT (and all other water systems) should be drained completely. When draining the boiler, turn off main electrical disconnect switch. When placing back in service, refer to Section 3 of this Manual for instruction. All draining and filling must only be done by a qualified service person. 2.4 Full Service Every Year In addition to the annual visual inspections, a qualified service agency should conduct a detailed inspection of all flue product carrying areas of the boiler and its venting system. 3. Shut Down and Restart 3.1 To Start the FT If drained, please refer to the Install and Operating Manual to ensure that the complete Setup procedure has been followed before starting this boiler. A complete Setup must be performed by a qualified service person. 3.2 Shutting Down the FT 1. Turn off the main electrical disconnect switch. 2. Close all manual gas valves. 3. If freezing is anticipated, drain the FT and be sure to also protect building piping from freezing. All water must be removed from heat exchanger and condensate trap or else damage from freezing may occur. Please refer to the Install and Operating Manual. This step to be performed by a qualified service person.

User s Manual - The FT, Heating Only, Boiler Page 5 4. The Control Display and Operation The Control Display E Status Light (constant green when operating normally) The Control Display has a Control Dial (E), 4 buttons (A, B, C, D), and a Liquid Crystal Display (with 72 back-lit segments). This section of this manual gives instruction on how to navigate into the many functions of the FT and to change temperature set points, set system variables and controller parameters. Buttons PRESS (Tap) Functionality PRESS and HOLD (5 seconds) A Display Power Turns Control Display ON / OFF B Modes Tap to return to menu (If Display Power was On ) Status Display Mode (If Display Power was Off ) Installer Mode C Heating Water CH set-point change mode (Maxium 82 C(180 F)) D Time / Date Set No Change To SET: Year/Month/Week/Day/Time/Min E Scroll / Select Menu select or value up(+)/down(-) or setting dial. Temperature Specifi cations Operating ambient Temperature Range : -10 to 60 C. Operating Relative Humidity up to: 90% at 40 C. Shipping & Storage Temperature Range of : -20 to 80 C. WARNING Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of

Page 6 4. The Control Display and Operation (continued) Symbol Name Description Service Reminder mode Outside Temperature Mode Anti-freeze mode Storage mode Information mode Communication state Time setting mode Fan operating mode Flame signal CH pump mode Storage pump mode Internal recirculation mode Celsius mode Fahrenheit mode Heat demand mode DAY mode Cascade System connecting mode Cascade System operating mode Service Reminder mode indication Outside Temp setting indication Anti-freeze mode indication Storage mode indication Information mode indication Communication state indication Time /Dispaly/Install mode indication Fan operating mode indication Flame Signal indication CH pump mode indication Storage pump mode indication Internal recirculation mode indication Indicated as Celsius temperature Indicated as Fahrenheit temperature Heat demand mode indication Current day mode indication Cascade System connecting mode indication Cascade System operating mode indication The LCD will illuminate when a user action is detected (a button is pressed) and will turn back off after 20 seconds.

User s Manual - The FT, Heating Only, Boiler Page 7 Operating Mode After the Power is turned on, and/or the Control Display is turned on, the Control Display will go through a Start Up checklist and briefl y show a sequence of diagnostic codes before entering into the Operating Mode. It will then display the following information. B A E C D Indicate Current Operating Temperature Set-Point Indicator If the Fan is operating If a fl ame is detected Celsius or Fahrenheit Date and Time indicator If Outside Temperature Sensor is operating If there is a Demand for Central Heat (CH) or If CH pump state is operating If Internal recirculation pump is operating If Communication state is activated The Control Display can operate through user and service modes that have specific LCD output and dedicated controls: Set-point change mode Lock mode Error mode Status display mode Outside Temperature mode Installer mode * Control Display will not allow changing of button in case of lock mode activated.

Page 8 5.4 Setting the Clock B A E C D The P-950EH Control Display does NOT have a daily timer or programmable thermostat. Setting the Clock a. Press and hold the Clock button for about 5 seconds. Set the Year by turning the dial E. And then, press the dial E to Save. b. Set the MON (Month) by turning the dial E to the desired month number. Then press the dial E to Save. c. Set the DATE (1-31, Day of the Month) by turning the dial E. Then press the dial E to Save. d. Set the HOUR (1-24, Hour of the Day) by turning the dial E. Then press the dial E to Save. e. Set the MIN (1-60, Minute of the Hour) by turning the dial E. Then press the dial E to Save. f. Set the Day (Sun - Sat) by turning the dial E. Then press the dial E to Save. To Exit at any time, press and hold the Clock button for about 5 seconds.

User s Manual - The FT, Heating Only, Boiler Page 9 5.5 CH Set Point Change Mode CH Set point Change Mode B A E C D To change CH Setpoint, press the C button. The CH Icon and current CH Setpoint will fl ash. Turn the E dial clockwise to increase, and counterclockwise to decrease CH setpoint, until desired temperature is reached. Press E dial to save changes and to Exit. Indicate Indicator Current CH Temperature Set-Point Celsius or Fahrenheit If Communication state is activated or If fl ame is detected Date and Time indicator If CH pump is operating If there currently a Demand for Central Heat (CH) Default CH set-point is 180 F (82 C) CH set-point range is 86 F ~180 F (30.0 C ~ 82.0 C)

Page 10 Status display mode To change any Status Parameter, 5.6 Status Display Mode Press and Hold Button B to get into the Status Display Mode. Rotate Dial E until you fi nd the Parameter that you wish to change. Tap Dial E to enter that Parameter. Adjust to the setting that you require and then press (tap) Dial E to save and to Exit. B A E C D Digital Display Status Display Parameter Description O: ot Outdoor temperature Current outdoor sensor temperature A: In 0-10 V display Current voltage of (0-10V input) b: tt CH target temperature in cascade system Current CH target temperature or Current System target temperature in a cascade system C: It CH return water temperature Current CH return water temperature d: Fr FAN speed ( rpm) Current FAN speed ( RPM) E: op CH supply temperature (Operating temperature) Current heating temperature F: Eh Exhaust gas temperature Current exhaust gas temperature H: dh Indirect DHW tank temperature * If temperature sensor is not connected then it will display with 0 F (0 C). Current DHW tank temperature I: oh Overheat water temperature Current Overheat water temperature 1: PH Time for supply power Unit : 1000hour Time for burner 2: rh Unit : 1hour operation Time for burner 3: rh Burner Operation L: rt on display Unit : 1,000hour L: rt operation Time on sub menu Cycle : 10 times the 4: It Cycle for ignition displayed unit Cycle : 10,000 times the 5: IH Cycle for ignition displayed unit M: CC N: St SELF Percentage of self units running. Percentage of self units running. ALL F1 F 19 Capacity for all operating cascade units Capacity for individual boilers System Temperature (cascade mode) * If system temperature sensor is not connected then it will display with 0 F (0 C). Percentage of all cascade units running. This screen shows the overal cascade power output. The range of this value of boilers communicating with themaster x 100. For example, if 8 boilers are connected and communicating, the maximum cascade power is 800%. Range: 0-100% Percentage of each cascade units running. Ex. F1, F2,. Current System Temperature (cascade mode)

User s Manual - The FT, Heating Only, Boiler Page 11 Notes:

H2375100D Notes: Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Customer Service and Product Support: 800.900.9276 Fax 800.559.1583 20 Industrial Way, Rochester, NH, USA 03867 1706 Document 1343D