DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Similar documents
DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Acusensor 3. Instruction Manual

ARCHITECTURAL DOOR HARDWARE SENSORS CATALOG

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

92831 TEL: (714) FAX:

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

D-Tect 2 GJD300 Quad PIR Movement Detector

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

DESIGN EASY ADJUSTMENT

Long-Range Barrier Sensors

External Wireless Sounder

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

BODYGUARD-T USER S GUIDE

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

DETECTION AREA OA-FLEX AIR T. Active Infrared Sensor FLEX EYE A X B C D E F G. Emitting area

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

English. Italiano. Português. Françias. Español

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

DS160/161 Request To Exit PIR sensors Installation Instructions

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

EVD-1 Installation, Operation, and Instruction Manual

SPACEMOTION SERIES SMM 01

Download the BEA DECODER app for a quick overview of settings

Movement Detector GJD 300

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

DUAL OPTIC. Installation manual

HX-80NRAM. High Mount Outdoor Detector

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

D-TECT Dual Tech. GJD360 Triple Technology External Detector

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

CONFIGURATION OF THE OPTICALS

FlowJam Bulk Flow Detection

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

DOLKPL1KB DOLKPS1KB DOLKSF1KB

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

D-TECT 3 IP. GJD260 IP Motion Detector

General Description. Industrial LuNAR DT AM Grade 3 Features

Download the BEA DECODER app for a quick overview of settings

SEC 2000 Millenium Infrared Gas Detector

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

INDEX. Installation recommendation

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Interrupted Ignition Series Oil Primary Control

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

Immunity. P/N: ver.b

STANDARD FEATURES SPECIFICATIONS

Installation Instructions

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Installation Instructions

D-TECT 2 IP. GJD230 IP Motion Detector

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Home Doorway Alert Kit

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Versatility. Maximum Energy Savings

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

OWNERS MANUAL MODEL 451 (-101 & -201)

MBCE-110/230UV Flame Sensor Module

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

SP-1000X. Panic Device Power Controller Installation Guide. Rev

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Static Pressure Control

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

PERMACONN PM1030 Includes DI300. Installation Manual

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Commercial Series TriTech Motion Detector. Reference Guide

DDS-A / DDS-B HYBRID SENSOR

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

Transcription:

NOTE: Set up for this sensor should be performed by an AAADM-certified installer. Section 1 General Description The DHR3 is a combination microwave/infrared sensor providing both motion detection and presence detection in one microprocessor controlled sensor for all types of automatic doors. Wide and narrow pattern width of the sensor is adjustable. Pattern depth and width are adjustable using mounting height, dip switches, pattern width and pattern angle adjustments. Frequency is selectable in four channels Self-Diagnostic means the sensor continuously monitors itself. Snow Mode Switch ensures against false operation caused by snow, insects, etc. Microprocessor provides programmable Presence Timer (2 sec., 30 sec., 60 sec., or infinity). Section 2 Parts Identification Section 3 Mounting Information 1. Do not mount higher than 10.5 ft. (3.2m). 2. Mount within 1.97 (50mm) from the bottom of the door engine cover. 3. Do not leave any objects which may move in the detection pattern. 4. Do not mount in a humid or steamy environment. 5. Do not mount where rain or snow will fall directly on unit. 6. Do not mount where snow or water will accumulate on floor if possible. 7. Do not mount in a place where reflection of sunlight will shine on unit. 8. Use different frequency settings for sensor in close proximity. 9. The radar part of the DHR3 sensor may be negatively influenced by metal close to or in the detection field. 1 2 3 10.5Ft. 4 5 6 7 8 Use Alternate Frequency. 9 A B Accessories To maximize the effectiveness of doorway detection, install the DHR3 outside and inside as shown below. Side View A B Plan View A Mounting Te mplate Installation Instructions Moving Door Leaf B Moving Door Leaf Mounting Screws Area Mask Connection Cable Page 1

Section 4 Mounting and Wiring 1. Using the mounting template provided, drill mounting and wire holes. Removing cover after installation: 2. Remove cover of unit. Section 5 Dip Switch Settings Dip Switch X 3. Fasten unit with mounting screws provided. Dip Switches are depicted in the Default position. * = Default 1 2 3 4 5 6 7 4a. Wiring to a door controller that can test the sensor. IR Presence Timer IR Frequency Monitor Mode Safety Relay Output Reflection Diagnostics NOTE: Test Input dip switch setting Y 6 to. Refer to Section 5: Dip Switch Settings. 2 Sec *30 Sec *A B *Normal *N.O. *N.C. *Normal 60 Sec Sec C D Snow Low Ref. 4b. Wiring to a door controller that cannot test the sensor. NOTE: Test Input dip switch setting Y 6 to OFF. Refer to Section 5: Dip Switch Settings. & IR Presence Timer: The sensor will detect a stationary object for the time period set by the Presence Timer for the inner 3 rows. The timer will reset and begin if any movement is detected. & Frequency: When more than two sensors are used in close proximity to each other, to prevent interference use alternate frequency settings. 5. House connectors in the space provided. Monitor Mode: A Snow Mode is available. Snow Mode should only be used in environments with heavy snowfall or other extreme conditions. Safety Relay Output: Refer to Section 9: Timing Chart of Events for full details on Safety Output. Reflection Diagnostics: A low reflected infrared signal is indicated by a slow flashing Red/Green LED. To ignore this low reflection error state, set this dip switch to Low Reflection (). 6. Replace cover. Page 2

Dip Switches are depicted in the Default position. * = Default Dip Switch Y 1 2 3 4 5 6 Section 6 Detection Area Detection Area Depth Adjustment: IR (Inner 3 Rows) Direction Detection Radar *OFF Activation Relay Output *N.O. N.C. or Activation Relay Output Config. *OFF Door Hold *Auto Open Doorway Learn *OFF Test Input Setting from Door Controller *OFF Direction Detection Radar: When set to, pedestrians moving away from the sensor will not be detected. Activation Relay Output: Refer to Section 9: Timing Chart of Events for full details on Activation Output. Activation Relay Output Configuration: Choose how relay output is configured. Door Hold: Switch to OPEN to hold the door in the open position. Doorway Learn: Allows the 1st row of detection to be focused inside the door close area without detecting the door movement. NOTE: When Doorway Learn is turned, the sensitivity level of the 1st row of detection is at maximum only when the outer rows of detection are activated. Test Input Setting from Door Controller: When connected to a door controller without a TEST input, set to OFF. When connected to a door controller with a TEST input, set to. Refer to Section 9: Timing Chart of Events for details. Detection Area Width Adjustment: IR (Inner 3 Rows). Page 3

Detection Area Depth Adjustment: Radar (Outer). Detection area varies depending on walking speed. Adjustment possible in 3 steps as illustrated. Installation height 7.2 (2.2m) & Sensitivity set to High. 3. Vacate the Detection Pattern immediately. While the sensor sees ANY moving objects in its DETECTI PATTERN, it will not proceed to the following step. 4. DO NOT enter DETECTI PATTERN for 10 seconds (Presence Detection Setting). 5. TEST the presence feature, especially near the door. When carrying out the following work, TURN OFF THE POWER: 1. When the floor conditions change. 2. Adjusting pattern or sensitivity. DOORWAY LEARN is OFF (Ref. Sec. 5-Dip Switch Settings) Upon power, the solid Green LED turns on indicating that the sensor is in standby mode and ready to detect. Green solid LED Installation height 7.2 (2.2m) & Sensitivity set to Low.! CAUTI: The detection areas shown above represent the actual position of the infrared and radar patterns. The actual detection area will vary depending upon the individual sensor installation, sensor settings and objects being detected. Presence Detection: It takes 10 seconds after the sensor powers up for presence detection to be initiated on all rows of detection. If someone enters the detection area before 10 seconds has elapsed, the sensor will continue to initialize until after 5 seconds with no motion being detected. DOORWAY LEARN is (Ref. Sec. 5-Dip Switch Settings) Upon power, the Red LED indicates a door open relay output to begin the Doorway Learn process. Section 7 Power & Doorway Learn Setting Red solid LED BEFORE APPLYING POWER, READ AND FOLLOW THESE INSTRUCTIS: When power is applied, the sensor will read and store the environmental optical parameters. This is necessary for Presence Detection to work properly. 1. CLEAR THE AREA OF ANY UNNECESSARY OBJECTS. 2. Apply POWER. Page 4

Green LED blinks for 37 seconds while the Doorway Learn process is carried out. Door opens/closes. Green blinking LED door activation caused by a person in order to build an accurate image of the door open and door close position. NOTE: When Doorway Learn is turned, the sensitivity level of the inner row of detection is at maximum LY when the outer rows of detection are activated. Green blinking LED! CAUTI: If you change dip switch setting or sensitivity volume, the sensor will be reset. During resetting, indicator LED is blinking with orange color. Keep away from detection area. After resetting, the sensor becomes the same state as it is turned Power-on. In case the product is used as a supplementary sensor: Set the detection area of the 1st row away from the door. Section 8 Verification of Operation After the Doorway Learn process is completed, sensor is in standby mode. Green solid LED After installation is complete, walk test the detection zone. If the detection zone is not as expected, adjust the detection area as referred to in Section 6. If the detection area is still not as expected then the sensor sensitivity can be increased by turning the potentiometer clockwise. When the sensor detects even though there is nothing in the detection zone, the unit s sensitivity can be decreased by turning the potentiometer counter-clockwise. Presence Detection: During the Doorway Learn process, the outer 3 rows of detection on the DHR3 sensor switch from motion detection to presence detection 10 seconds after power. The inner Doorway Learn row of detection will switch from motion to presence detection after the Doorway Learn process is complete. Doorway Learn Failure & Recovery: If a person enters the detection area during the Doorway Learn process, it may not be successfully completed. In this case, the sensor will carry out the Doorway Learn process on Page 5

Section 9 Timing Chart of Events After installation is complete, walk test the detection zone. If the detection zone is not as expected, adjust the detection area as referred to in Section 6. Safety Output/Test Input Activation Output Section 10 Door Maintenance Work When carrying out door maintenance work with power applied to the sensor, on door controllers that are wired to TEST the sensor, ensure to set the dip switches as shown here: NOTE: Return dip switch settings to original state when maintenance work is complete. Page 6

Section 11 Self Monitoring When the sensor has an internal sensor error, the door will remain open and the Green/Red LED blinks alternately. The frequency of flashing indicates the type of problem as explained below: Flash LED CAUSE Frequency Fast Slow Please replace sensor. Confirm sensitivity potentiometer is set to maximum and repower the sensor. If the error persists, set Dip Switch X 7 to Low Reflection. *****EXTREMELY IMPORTANT***** After final set-up, test unit(s) completely to ensure that proper coverage has been achieved (width, depth and location of the pattern must be tested). After the installation and operational check of the system: 1. Place the proper labels on the door per ANSI/BHMA A156.10 & BS 7036. 2. Instruct the owner of the door system operation and how to test it. This should be checked on a daily basis. 3. Instruct the owner on what to do if the door or any of its components become damaged. 4. Strongly recommend to the owner that the complete entry be inspected twice a year as part of the service agreement. Section 12 Troubleshooting PROBLEM 1: Door does not open LED STATUS: Off CAUSE 1: Sensor Connector SOLUTI 1: Tighten connector or reconnect CAUSE 2: Power Supply SOLUTI 2: Check that the power supply is properly connected and 12V to 24V AC or DC CAUSE 3: Sensor Wiring SOLUTI 3: Double check sensor wiring. PROBLEM 2: Door operates by itself (ghosting) LED STATUS: Door Opens=RED or BLUE, Door Closes=Green CAUSE 1: There is an object moving in the detection area SOLUTI 1: Remove the moving object from detection area CAUSE 2: Sensitivity too high SOLUTI 2: Turn down sensitivity CAUSE 3: Dust, frost or water droplet on the sensor lens SOLUTI 3: Wipe sensor lens with clean cloth and install a weather cover if necessary CAUSE 4: Detection area overlaps with that of another sensor SOLUTI 4: Ensure different frequency setting for each sensor CAUSE 5: Detection of falling snow, insects, leaves, etc. SOLUTI 5 Adjust the Monitor Mode PROBLEM 3: When door opens or closes, LED ORANGE LED STATUS: ORANGE CAUSE 1: Detection row ROW 1 ( ROW 2 when Doorway Learn is turned ) is focused too close to the door SOLUTI 1: Adjust detection depth of rows away from the door PROBLEM 4: Door opens and remains in the open position LED STATUS: RED CAUSE 1: Detection area changed, while infinity presence timer setting is in use SOLUTI 1: Repower the sensor or change the presence timer settings to 30 or 60 seconds CAUSE 2: Incorrect Sensor Wiring SOLUTI 2: Double check sensor wiring CAUSE 3: Reflected Signal Saturation SOLUTI 3: Remove highly reflective objects from the detection area, or lower the sensor sensitivity Page 7

LED STATUS: BLUE CAUSE 1: Moving objects in radar area SOLUTI 1: Remove moving objects from detection area LED STATUS: GREEN/RED FAST FLASH CAUSE 1: Internal Sensor Error SOLUTI 1: Replace the sensor LED STATUS: GREEN/RED SLOW FLASH CAUSE 1: Reflection of the transmitted infrared signal from the floor is too low SOLUTI 1: Increase sensor sensitivity or change the Reflection Diagnostics Dip Switch X 7 from Normal to Low Ref LED STATUS: ORANGE BLINKING (Slow) CAUSE 1: Door Hold (Dip switch Y 4 set to Open) SOLUTI 1: Turn Door Hold Dip Switch Y 4 to Auto Section 12 Technical Data Model... DHR3 Detection Method... Doppler Shift Radar & Active Infrared Reflection Max. Installed Height... 10.5 ft. (3.2m) Power Supply... 12 to 24 V AC or DC ± 10% Power Consumption... AC24V-2.5VA, AC12V-2.5VA DC24V-80mA, DC12V-150mA INFRARED SENSOR Detection Method... Active Infrared Reflection Output Holding Time... 0.5 seconds Response Time... 0.1-0.2 seconds Presence Timer... 2 sec., 30 sec., 60 sec., or infinity ( ) Output Contact... 7.5mA Max (Resistor Load) 55V DC Max Voltage 50mA Max. Current MICROWAVE SENSOR Detection Method... Doppler Shift Radar Operating Frequency... 24.15 GHz Output Holding Time... 1.5 seconds Response Time... 0.1-0.2 seconds LED Indication... GREEN = Standby GREEN BLINKING - Doorway Learning (when dip switch Y 5 is ) BLUE = Radar Detecting RED = IR Detecting / Radar and IR Detecting ORANGE = Detection row ROW 1 ( ROW 2 when Doorway Learn is turned ) is detecting door movement ORANGE BLINKING (Fast) = Indicates a change of dip switch settings ORANGE BLINKING (Slow) = Door Hold is turned (When dip switch Y 4 is ) GREEN/RED BLINKING (Fast) = Internal Sensor Error GREEN/RED BLINKING (Slow) = Reflected infrared signal from the floor is very low Test Input... 6mA @ 24V DC IP Rating... IP54 Temperature Range... -4 F to 140 F (-20 C to 60 C) Operating Humidity... Below 80% Weight... 0.56 lbs. (0.26kg) Color... Black, Silver Accessories... Cable Mounting Screws (2 pcs.) Mounting Template Installation Instructions Section 13 External Dimensions Page 8

Section 14 Warranty MS SEDCO guarantees this product to be free from manufacturing defects for 3 years from date of installation. Unless MS SEDCO is notified of the date of installation, the warranty will be in effect for 3 years from the date of shipment from our factory. If, during the first 3 years, our motion detector or support device fails to operate and has not been tampered with our abused, the unit can be returned prepaid to factory and it will be repaired free of charge. After 3 years, the unit will be repaired for a nominal service charge. This limited warranty is in lieu of all other warranties expressed or implied, including any implied warranty of merchantability, and no representative or person is authorized to assume for MS SEDCO any other liability in connection with the sale of our products. All warranties are limited to the duration of this written warranty. In no event shall MS SEDCO be liable for any special, incidental, consequential or other damages arising from any claimed breach of warranty as to its products or services. Page 9