Mechanical Seal RG-4 stationary, double, liquid sealed

Similar documents
Mechanical seals external, single or double, to DIN EN 12756

AC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY ELECTRICAL CONNECTIONS INSTALLATION

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

PENGUIN SERIES HSC PUMPS INTRODUCTION

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

AC6/6H & AC8/8H Horizontal Metric Models

BioMaster 250/350/600 BioMaster Thermo 250/350/600

SAM TURBO INDUSTRY LIMITED

Chemical Motor Pump Unit BN

Vertical Ring-section Pump WKTB. Type Series Booklet

Instructions for Installation, Operation, Care and Maintenance

Dosing system. Commissioning and maintenance manual eco-pen300

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

CENTAFLEX Series A Assembly and operating instructions CF-AR M EN Rev. 2

HD Kompakt Service Manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

Pneumatic agitator A MAN R

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Water Distiller Service Manual

Chemical Pumps Vertical Chemical Pump Type TNP

MARLOW PUMPS RECIRCULATION

USER S MANUAL ATH WH220

Design and manufacture of agitators since INSTALLATION MANUAL Start-up and maintenance. Top-entry agitators

INSTRUCTION AND REPAIR MANUAL

Heat Exchanger Block Replacement Instructions

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.

Manual Wöhler Rotary Viper Vent M 10

VERTICAL GLANDLESS PUMP

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installing a Fast Oven Upgrade Kit

AXPR Wall Mounted Axial Panel Fans

568X, 587X, 588X Series

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

SuperKlean Washdown Products

VETO CLEANER 500 FLUE GAS CLEANER

Lo-Carbon T-series Window & Roof Models

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

Domestic Pump Vacuum and Boiler Feed Units Series VCMD TM INSTRUCTION MANUAL DN0137 REVISION F

Wallis & Stevens 7C. hand operated sprayer for cold bitumen emulsion. Contact: Sales at BX Plant on or

INSTRUCTION MANUAL with Replacement Parts

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

Selfpriming Centrifugal Pumps. Type HZS/HZSA

Rev Installation Guide. Sondex Industrial and Marine Pumps

This label warns for risk of electrical shock when failing to observe.

Operating and installation instructions

Installation, Operation, and Maintenance

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Service package PDAD- -SP (en) Assembly instructions d [ ]

OWNERS INSTRUCTION MANUAL

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

1 L Rotary Vacuum Evaporator Instruction Manual

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Installation and operating instructions. E.2 Series high efficiency circulator

Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

HOT WASHER MODEL NO: KING150

CRU-S Series Stainless Steel Condensate Recovery Unit

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

CL & CLG Clamp Mount Mixers

Operating Instructions

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

569, 570, 571, 572 Series

569, 570, 571, 572 Series

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

INSTRUCTION MANUAL W-400

-Zumpe GmbH. Operating Instructions Flexible Impeller Pumps UNISTAR COMBISTAR NIROSTAR ACOSTAR. Pumps and Sprayers

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

Altra Series Dampener

Family Curve. Submersible Grinder Pumps 1¼" and 3" Discharge. Effluent/Grinder Pumps.

TITAN FLOW CONTROL, INC.

Machine needle shut-off nozzle type-s

Operating instructions. for radial fans for use in potentially explosive atmospheres

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

Installation & Operation Instructions Nr _EN_Manual

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

Transcription:

Series SCK INSTALLATION AND OPERATING MANUAL Translation of the original manual Mechanical Seal RG-4 stationary, double, liquid sealed Keep for future use! This operating manual must be strictly observed before transport, installation, operation and maintenance Subject to change without notice. Reproduction is generally permitted with indication of the source. Richter Chemie-Technik GmbH S- Edition 03/2010

Series SCK Mechanical seal RG-4, stationary, double, liquid sealed Page 2 List of Contents List of Contents... 2 Relevant documents... 2 1 Technical data... 2 2 Safety, transport and storage... 3 2.1 Intended use... 3 3 Product description... 3 4 Commissioning / Shutdown... 3 4.1 Initial commissioning... 3 4.2 Mechanical seals... 3 4.2.1 Use in an explosive area... 3 4.2.2 Stationary, double mechanical seal RG-4, liquid sealed... 3 4.3 Improper operation and their consequences (examples)... 4 5 Maintenance... 4 5.1 Dismantling of a mechanical seal RG-4, liquid sealed... 4 5.1.1 Dismantling of back plate, impeller and RG-4. 4 5.1.2 Dismantling of shaft sleeve... 5 5.2 Notes on assembly... 5 6 Faults... 5 7 Sectional drawing... 6 7.1 Stationary, double mechanical seal RG-4, liquid sealed... 6 7.2 Legend... 7 Relevant documents Operating manual SCK long-life grease and oil bath lubrication 9220-050-en Operating manual mechanical seal of the manufacturer 1 Technical data Manufacturer : Richter Chemie-Technik GmbH Otto-Schott-Str. 2 D-47906 Kempen Telephone: +49 (0) 2152 146-0 Fax: +49 (0) 2152 146-190 E-Mail: richter-info@idexcorp.com Internet: http://www.richter-ct.com Authorised person acc. to machinery directive 2006/42/EG: Gregor Kleining Designation : Series SCK mechanical seal: RG-4, stationary, double, liquid sealed Materials : Seal housing: Stainless steel Wetted parts: Mechanical seal: SSiC, FKM, FFKM etc., see also data sheet Temperature range : see installation and operating manual SCK, Section 1. Temperature classes : see installation and operating manual SCK, Section 2.6.7.

Series SCK Mechanical seal RG-4, stationary, double, liquid sealed Page 3 2 Safety, transport and storage The relevant sections in the adjacent installation and operating manuals apply to safety, transport and storage. This installation and operating manual is only valid in conjunction with the installation and operating manuals of SCK long-life grease and oil bath lubrication 9220-050-en 2.1 Intended use Double mechanical seals for plastic-lined pumps of the series SCK are suitable for the use of aggressive, toxic, pure and inflammable media. The instructions contained in the operating manual or contractual documentation are to be observed, if necessary consult the manufacturer. All the important features are documented in the data sheet included in the scope of delivery. 3 Product description For a product description of the pump, see the installation and operating manual for the SCK series. The sectional drawing shows a stationary, double mechanical seal RG-4, liquid sealed. See Section 7. All components which come into contact with the process medium are either lined with plastic or are made of other resistant materials, e.g. silicon carbide. 4 Commissioning / Shutdown 4.1 Initial commissioning See installation and operating manual for the series SCK. 4.2 Mechanical seals The design and material combination are specified in the data sheet. The proper condition of the components and the protective facilities must be ensured to prevent any risk from escaping medium. The regulations and recommendations of the mechanical seal manufacturer must always be observed. 4.2.1 Use in an explosive area Use in an explosive area means that only mechanical seals may be employed which permit observation of temperature. The operating manual of the respective mechanical seal manufacturer is an integral part of this general operating manual. This permits, amongst other things, the calculation of the expected surface temperature at the mechanical seal. The suitability for the permissible temperature class as per ATEX is hereby given. CAUTION: The permissible temperature class of the complete unit (pump, mechanical seal, coupling, motor) is determined by the lowest temperature class of the individual components. Example: Pump T4, mechanical seal T3, coupling T4, motor T4 In both cases the unit may only be used in atmospheres which may ignite above the temperature class T3, i.e. >200 C (>392 F). 4.2.2 Stationary, double mechanical seal RG-4, liquid sealed A pump fitted with a double mechanical seal must not be filled with a product before the pressurisation system provided has been started up. Otherwise damage could occur, e.g. opening of the wetted sealing gap, before start-up. To guarantee safe operation, the pressure of the sealing medium must be 1-2 bar above the pressure of the process medium at the mechanical seal at Q=0 m 3 /h. To guarantee safe operation, the pressure of the sealing medium must be 1-2 bar above the pressure of the process medium at the mechanical seal at Q=0 m 3 /h.the required sealing pressure can be determined as follows: 2/3 of the delivery pressure at Q = 0 m 3 /h + supply pressure + 1-2 bar safety margin

Series SCK Mechanical seal RG-4, stationary, double, liquid sealed Page 4 The supply pressure is measured in bar at the pump suction nozzle. If no measuring point is available, the supply pressure can be calculated using the following formula. Using the same formula, the delivery pressure at Q=0 m 3 /h can be determined with the pump characteristic curve. ρ H(mFS) x (kg/dm ) p (bar) = 10,2 p = supply pressure or delivery pressure H = supply height or delivery head ρ = density 3 4.3 Improper operation and their consequences (examples) Improper operation, even for a short time, can result in serious damage to the unit. In connection with explosion protection, potential sources of ignition (overheating, electrostatic and induced charges, mechanical and electric sparks) may result from these inadmissible modes of operation; their occurrence can only be prevented by adhering to the intended use. For examples, see installation and operating manual SCK, Section 6.6. Are the available connections correctly made? SE - quench or sealing medium inlet SA - quench or sealing medium outlet See also sectional drawing in Section 7.2 5 Maintenance The regulations of the mechanical seal manufacturer must always be observed. See also the installation and operating manual for the SCK series. It is important to replenish in good time any sealing liquid which has escaped and to monitor the sealing liquid pressure. The minimum sealing liquid pressure must never be undershot as long as the pump housing is under pressure (refer also to the description of the pressurisation system used and Section 4.2.2) If the sealing liquid pressure is too high, this indicates a defect in the mechanical seal even though the mechanical seal on the atmosphere side is completely tight. The pump must then be shut down so that no serious damage occurs. Substantial damage generally occurs if the aggressive process medium enters the pressurisation system as a result of a drop in the sealing liquid pressure to below the minimum pressure. If there is a risk that, for example, pressure surges occur in the plant, precautions must be taken to prevent damage. To this end, for example, the sealing liquid pressure can be increased. However, this is only possible up to the pressure limit of the mechanical seal used. 5.1 Dismantling of a mechanical seal RG-4, liquid sealed Dismantling can be checked using the sectional drawings in Section 7 and Section 9 of the installation and operating manual SCK as well as the components available. 5.1.1 Dismantling of back plate, impeller and RG-4 First of all relieve the mechanical seal by undoing the attachment screws 901/5. Undo screws 901/6 and washers 554/6 of the bearing pedestal / back plate. Move the back plate almost up to the impeller with light hammer blows. Undo back plate (for instructions, see Sections 4.2.1 and 7.7.4 in the installation and operating manual SCK). Move the back plate almost up to the impeller with light hammer blows. Bearing pedestal group 3: Labyrinth disc 555 must be secured with two bolts prior to the dismantling of the impeller. For this purpose there are 2 bores Ø5mm in the bearing pedestal. The double mechanical seal is relieved of pressure as a result. See Dismantling in Sections 7.7.1 and 7.7.5 in the installation and operating manual SCK. Loosen impeller 230 with a strap wrench or assembly wrench. Right-hand thread. For assembly aid for impeller, see Section 10.1 in the installation and operating manual SCK. With some pump the work sequence is to be repeated once or twice sizes so that the cup springs 950/1 can be completely relieved. Then completely remove the impeller 230. Remove the mating ring 475/1 and the flat gasket 400/1. Remove back plate (for sequence, see Sections 4.2.1 and 7.7.4 in the installation and operating manual SCK) with centering ring 511, O-ring 412/3, seal face 472/1 and intermediate ring 509/1.

Series SCK Mechanical seal RG-4, stationary, double, liquid sealed Page 5 Pull the entire rotary ring carrier 483, comprising the parts rotary ring carrier 485/1 (O-ring 412/5, thrust ring 474, spring 477/1, and stud 560/1) out of the seal housing 483. 5.1.2 Dismantling of shaft sleeve Pull the shaft sleeve 524 with the rotating unit 470/1 which is still installed off the shaft. For changing the rotating unit, undo the setscrew 904/2 (depending on the design of the shaft sleeve) and pull it off the shaft sleeve 524. Observe the operating manual of the mechanical seal manufacturer. Remove mating ring 475/2. If plastic bearing points of the mating ring 475 or of the shaft sleeve 524 are destroyed, they can be renewed by the pump manufacturer. 5.2 Notes on assembly Only use original spare parts. Do not use any defective parts. The recommendations of the mechanical seal manufacturer are to be observed. Bearing pedestal group 3: Always make sure that when installing the mechanical seal the labyrinth disc is secured by 2 bolts. The bolts must be removed again after assembly of the impeller. The rotary ring carrier 485/1 must engage in the spring-type slotted pin 531/1. Mark position beforehand. The seal face 472/1 must engage in the studs 560/1. Mark position beforehand. In the case of the shaft sleeve made of Al 2 O 3 the rotating unit 470/1 must be flush with the key 940/2 and tightened with the setscrew 904/2. In the case of the shaft sleeve made of stainless steel the key is positioned firmly against one end. When pushing on the mating ring 475/1, make sure that the position of the flat section matches that on the shaft. 6 Faults Faults may result from inadmissible modes of operation. Such inadmissible modes of operation even brief ones may cause serious damage to the unit. In connection with explosion protection, potential sources of ignition (overheating, electrostatic and induced charges, mechanical and electric sparks) can result from these inadmissible modes of operation; their occurrence can only be prevented by adhering to the intended use. See also Section 2.1. Should there be any uncertainty about the remedy to be applied, please inquire at the in-house pump office or at the pump manufacturer's. See also Section 8 in the installation and operating manual of the SCK series.

Series SCK Mechanical seal RG-4, stationary, double, liquid sealed Page 6 7 Sectional drawing 7.1 Stationary, double mechanical seal RG-4, liquid sealed

Series SCK Mechanical seal RG-4, stationary, double, liquid sealed Page 7 7.2 Legend 161 back plate 210 shaft 400/1 flat gasket 412/x O-ring 470/1 rotating unit 472/1 seal face 475/x mating ring 483 seal housing 485/1 rotary ring carrier includes 412/5 o-ring 474 thrust ring 477/1 spring 533 guide sleeve 560/1 stud 935/1 snap ring 509/1 intermediate ring 511 centering ring 524 shaft sleeve 531/x spring-type slotted pin 901/5 hex. screw 904/2 * setscrew 917/x screw-in pipe connector 940/2 key SE= Flushing inlet SA= Flushing outlet / venting connection * Drilled during assembly only with shaft sleeves made of Al 2 O 3