Enhance DX. Mattress Replacement System. User Manual

Similar documents
Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

CONTENTS IMPORTANT SAFEGUARDS INTRODUCTION PRODUCT DESCRIPTION INSTALLATION OPERATIONS CLEANING...

Veterinary Patient Warming System Controller User Manual

CLETEF-786. Infrared Thermometer Instruction Manual

User Instruction Manual

Transcend Heated Humidifier User Manual

ASPIRE Laboratory Aspirator

User Instruction Manual

ULTRASONIC AIR SALINIZER. Owner s Manual. Saltair Home Salt Therapy

Iron - low. - medium - high Do not iron. Bleach - chlorine. Do not bleach. Tumble dry - low - medium - high Do not tumble dry

Veterinary Patient Warming System Service Manual. For information on operating the Hot Dog Patient Warming System, refer to the Instructions for Use

HydraTherm TM OPERATION MANUAL

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

PEAK Platelet Rich Plasma System

COOLFLOW IRRIGATION PUMP USER MANUAL

Operator s Manual. WarmTouch. Model WT-5300A Patient Warming System

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

Instruction Manual Mini SAD Light Box Code: A54LC

TM Machine WetAlert TM Wireless Wetness Detector Home User s Guide

English 1 AIR ALTERNATING PRESSURE MATTRESS REPLACEMENT SYSTEM

Operator s Manual. WarmTouch. Model WT-5900 Patient Warming System

EkoSonic Control Unit Instructions for Use

Owner s/service Manual. LED Light Source for A-Series TM. Microscopes M A801-LED

AtmosAir Mattress Replacement System User Guide Instructions for Use

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

Companion 5. Oxygen Concentrator PROVIDER TECHNICAL MANUAL

User Instruction Manual

Stryker Glide Lateral Air Transfer System. Operations/Maintenance Manual. Model 3062

Model IC-1545-DL Multi-Flo DVT Combo

Dyna-Form Air. Alternating Pressure Relief Overlay System

RESmart CPAP System. User Manual

User Manual. Mistral-Air Plus Warming Unit. MA1100-EU ( V~, 50/60 Hz) MA1100-US ( V~, 60 Hz) MA1100-JP ( V~, 50/60 Hz)

BNT-1000 Infant Radiant Warmer Operate Manual

User Instruction Manual

Instructions For Use

CARESTREAM DRX-1 System

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss OPERATOR S MANUAL

User s Manual. Alternating Air Mattress Model No.: MA-6100

USER INSTRUCTION MANUAL SAPPHIRE SERIES 1100 & 1100EC

WARNINGS AND PRECAUTIONS FOR THE USE OF THE IQ TM Intelligent Driver

Directions for use MACH LED 300DF

USER INSTRUCTION MANUAL SAPPHIRE SERIES 800

Dear customer, Be sure to use the device properly according to the instructions given by medical professionals.

Instructions For Use SC-2004-OC, SC-2004FC-OC and SC-2008-OC. Sequential Circulators

micomme, Sepray,, are registered trademarks of Micomme Medical Technology Development Co., Ltd. All rights reserved. Modes: Sepray CPAP 25,Sepray CPAP

5. Instrument and accessories discharging must be done following current law regulations in every country of use.

AIR EXPRESS LAL. P1500 LOW AIR LOSS THERAPY SYSTEM REF C1500 Control Unit REF M1500 Mattress. Operator s Manual P/N /03

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

OPERATION MANUAL. Multi Function Ultrasonic Scaler. Varios 970. Please read this Operation Manual carefully before use, and file for future reference.

OPERATION & CARE MANUAL FOR P-2010-S BLANKET WARMING CABINET

Important user information

AMBIENCE Low Air Loss Mattress Replacement System

CARESTREAM DRX-1 System Detector CARESTREAM DRX-1C System Detector CARESTREAM DRX 2530C Detector Model DRX User Guide

Titan Series Blanket Warmer

Bio Compression s SC-3004-DL

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

Flowtron ACS900. Instructions For Use. ...with people in mind INT1 Rev A - 05/2015

User Instruction Manual

Elite Series Blanket Warming Cabinet

Delta Plus. PA8900 Bariatric Mattress Replacement System. User Manual

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System


Blanket Warming Cabinet

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

REMstar SE USER MANUAL

Portable Oxygen Concentrator Model: RS User Manual

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

User Manual standard for Medical Electrical. Control Number 95CG. Classified by. Underwriter s Laboratory Inc. for UL

TABLE OF CONTENTS. Instructions for Use are updated periodically, so please check willowpump.com for current version.

Neptune 2 Waste Management System

SC-3008-DL SEQUENTIAL CIRCULATOR

MULTI-FUNCTIONAL PORTABLE ROTATION SYSTEM P4000 P4001 C4000 Series Control Unit M4000 Series Mattress. Operator s Manual P/N Rev B 10/10

Instructions for Use

IB-CB200GB _Layout 1 16/12/ :02 Page 1. Instruction Manual. Customer Service Number +44 (0) CB-200-GB

CVX-300 Excimer Laser System. Gen 4.0 Operator s Manual

Patient Warming System Controller Model WC5X Service Manual

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CL1000 Ceiling Light OWNER S MANUAL. Marus Fruehauf Drive Charlotte, NC USA

Regulatory Information and Specifications

OPERATORS GUIDE Rocket R54569 PSU

R00 JH 1/23/2015 SimplyGo Mini

Customers must fill in and mail the warranty card in order to activate the warranty.

Operating Instructions ATMOS LS 31 LED. English GA1GB Index 02

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

WINDSOR ACTIVE REPLACEMENT

Technical Service Manual KANMED Babywarmer BW3

USER MANUAL TOTAL OXYGEN CONCENTRATOR. Model: PM4400 Series SAVE THESE INSTRUCTIONS

SUCTION PUMPS CareLinc Home Medical Equipment and Supply, LLC SS170CE00101

User Manual. Advanced Markus Chamber Ionization Chamber Type 34045

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

BreathCare PAP Positive Airway Pressure Device

CVX-300 CVX-300 -P Excimer Laser System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

LSU. Laerdal Suction Unit. Directions for Use. Cat. No Reusable. Cat. No Serres

MyKi Care Thermometer (MCT 1.0) USER MANUAL

Mason Air AS8800/ AS8800-RR/AS Instruction Manual. Low air loss/alternating pressure mattress

Convertible Powered/ Non-Powered Dynamic Mattress System. Operation Manual. Distributed by:

Single Wet Vacuum Pump CV-101 FS (1HP) & CV-102 FS (2HP)

STS Directory Accreditation number: STS 0009

Transcription:

Enhance DX Mattress Replacement System User Manual Prius Healthcare USA 580 Corporate Center 4025 Tampa Road, #1117 Oldsmar, FL 34677, USA TEL: (813)854-5464 FAX: (813)854-5442 1111

Content 1. THE PURPOSE OF THIS MANUAL... 1 2. PRODUCT DESCRIPTION... 1 Master Control Unit Features Mattress Features 3. TECHNICAL DATA... 2 Master Control Unit Enhance DX Mattress Replacement Symbol Definition 4. INSTRUCTION FOR PROPER USE... 3 5. CLEANING... 4 The Mattress The Master Control Unit Replace Air Filter Waste Disposal 6. STORAGE AND CARE... 6 7. MAINTENANCE AND TROUBLESHOOTING... 6 8. EMC RELATED NOTIFICATION... 7 9. WARRANTY... 10 1

Warning Connect the Master Control unit to a proper power source. Keep the pump and mattress away from open flame. Keep sharp objects away from mattress. Do not place heating device on or near the mattress system. Do not use the system in the presence of any flammable gases. (Such as anesthetic agents) Caution The Alternating System should always be used in accordance with your Institutions pressure care guidelines. Re-positioning of the patient is always recommended when using an alternating pressure air mattress (APAM). The control unit should only be repaired by an authorized technician. Do not drop the control unit. Do not store the system in direct sunlight or extreme cold conditions Operation Temp: 15-40 C ( 59-104 ) R.H. : 30-75 % 2

1. The Purpose of this Manual This operation manual is mainly focused on the set up, cleaning and routine maintenance of the Enhance DX Alternating Anti-Decubitus System. We recommend keeping this manual available to answer questions related to the system. 2. Product Description This product is intended to help reduce the incidence of pressure ulcers while optimizing patient comfort. The Enhance DX is an alternating mattress replacement system used in the prevention and treatment of pressure ulcers. By using the established principles of alternating therapy the Enhance DX offers patients a comfortable and relaxing support surface which can prevent skin breakdown and enhance wound healing. The Enhance DX Control Unit Features LED indicator for function status. Electronic adjustable comfort setting. 2-in-1 alternation with 10 minutes cycle time. Adjustable Comfort Setting Alternate/Static Control Switch Function Status LED Indication ON/OFF Switch Mattress Features Therapeutic micro low air loss helps manage moisture and provides alternating therapy to prevent and treat pressure ulcers. Modularized design for easy air cell replacement. A vapor permeable, oversized, pliable, quilted nylon top cover provides low shear, friction and moisture protection. CPR quick release for rapid deflation. Integrated power cable management for organization and safety. 1

3. Technical Data Master Control Unit Model Name Enhance DX Model No. FC-PHR0004 Size (inch) 10.1 (L) x 4.5 (W) x 8.3 (H) Weight (lbs) 5.1 Cycle Time 10 min Min Operating Pressure 12 +/- 5mmHg Max Operating Pressure 47 +/- 5mmHg Rated Voltage AC 110-120V Rated Frequency 60 Hz Fuse Rating 1A 250V Max Current 0.1A Classification Class I, Type BF Not AP or AGP type Operation Temperature 15 C (59 F)~ 35 C(95 F) Operation Humidity 30% ~ 75% Mode of Operation Continuous IEC 60601-1, Standard CAN/CSA C22.2 No. 601.1, IEC 60601-1-2 Enhance DX Mattress Replacement Model No FM-PHR0004 Size (inch) 36 (W) x 80 (L) x 8 (H) Weight (lbs.) 21 Cell Number 18cells Cells Material Black Nylon with PU coating Cover Material Blue Nylon w/ PU coating finish Base Material Black Polyester w/ PVC coating Weight Capacity 500lbs 2

Symbol Definition Refer to Accompanying Documents Waste Disposal Type BF Applied Part Alternating Current Caution 4. Instruction for Proper Use 1. Unpack the system and place the pump at the foot end of the bed. 2. Remove the existing mattress from the bed frame. 3. Place the Enhance DX mattress on the frame and position mattress so the air tube is at the foot of the bed. 4. Secure the Enhance DX mattress straps to the bed frame.. 5. Hang the control unit on the foot board of the bed frame. 6. Connect the mattress air hose to pump. 7. Check air hoses under the mattress to make sure they are not kinked. 8. Plug in the control unit and turn it on. 9. The pump will now inflate the mattress. 3

10. Press the control button on pump to select alternation or static therapy. 11. Set the required pressure by pressing the + to increase pressure or - to reduce pressure. 12. Pressure is constantly monitored by the control unit. When pressure is less than the selected pressure the Low Pressure LED will illuminate and an alarm will sound. 13. For emergency mattress deflation turn the CPR valve to the OPEN position. The mattress should deflate within 20 seconds. To close the CPR simply turn the valve to the CLOSE position. Open Close 5. Cleaning The Mattress The mattress should be cleaned weekly using a damp soft cloth and mild detergent. The mattress cover can be washed and thermally disinfected in a washing machine by following the procedure below. (Do not use a phenol based cleaning solution) Industrial Pre-Wash Cold 10 minutes Main Wash 60 (140 ) 6 minutes Main Wash 70 (158 ) 10 minutes Spin Cycle 2 minutes 3 Cold Rinses Spin Cycle 5 minutes Domestic Pre-Wash Cold Main Wash 70 (158 ) 10 minutes Spin Cycle 2 minutes Cold Rinses Spin Cycle 5 minutes Tumble Drying or Tunnel Drying is not recommended. Mattress cells can be wiped down with a solution of sodium hypochlorite 1000ppm or any other non-phenolic germicidal solution. 4

The Master Control Unit CAUTION SWITCH OFF THE ELECTRICAL SUPPLY TO THE PUMP AND DISCONNECT THE POWER CORD FROM THE MAIN SUPPLY BEFORE CLEANING AND INSPECTION The pump unit should also be cleaned weekly using a damp soft cloth and mild detergent. The pump casing is manufactured from ABS plastic. If the case is soiled the pump can be wiped down with a solution of sodium hypochlorite dilution, 1000ppm, or any EPA approved hospital grade disinfectant. (Do not use a phenol based cleaning solution.) The air filter should also be cleaned and checked at a minimum of every six months. The air filter can be removed by removing filter cover and pinching center of the filter and pulling outward from the back of the cover. Replace Air Filter 1. Remove air filter and replace with a new one. 2. Use a soft bristle to remove dust and difficult dried-on soil. Filter Waste Disposal This Product has been supplied by an environmentally conscious manufacturer and complies with the WEEE. This product may contain substances that can be harmful to the environment if disposed of in places that are not approved by your state, local or federal laws. Please be environmentally responsible and recycle this product through your recycling facility at its end of life. 5

6. Storage and Care Master Control Unit: Check the power cord and plug for abrasions and excessive wear. Plug in the unit and verify air flow from the hose connection ports. Place in plastic bag for storage. Mattress: Check the air manifold for kinks or breaks and replace if necessary. Set CPR valve to OPEN and disconnect the air hose to the pump. The mattress will now deflate and can be packed for storage. It is recommended that the following proceedings are used whenever the system is being stored or transported to another location: Temperature limitations: 5 C (41 F) ~ 60 C (140 F) Relative humidity: 30% ~ 75% 7. Maintenance & Troubleshooting No daily maintenance is required. This equipment should only be serviced by a qualified and authorized technician. For common trouble shooting tips please refer to the chart below. Symptom Inspection Procedures Possible Solution The pump is not functioning. 1. Check power source connection. 2. Check fuse. 1. Connect to proper power source. 2. Replace fuse. 3. Refer to qualified service technician if problem persist. Low pressure LED is constantly illuminated or the mattress is not inflating while pump is in operation. 1. Check hoses and hose connections. 2. Check CPR valve. 3. Check air cells for holes or tears other than where designed. 1. Make sure all connections are secure. 2. Make sure CPR valve is in the CLOSE position. 3. Replace damaged air cell if necessary. 4. Refer to qualified service technician if problem persist. Pump is noisy. 1. Make sure pump is resting against a solid surface. 1. Reposition the pump. 2. Refer to qualified service technician if problem persist. 6

8. EMC Related Notifications Guidance and manufacturer s declaration electromagnetic emissions The air pump is intended for use in the electromagnetic environment specified below. the user of the air pump is responsible for making sure that it is used in such an environment. The customer or Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Voltage fluctuations/ flicker emissions IEC 61000-3-3 Group 1 The air pump uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. Class B The air pump is suitable for use in all establishments including domestic and those Class A directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Complies Recommended distances between portable and mobile RF communications equipment and the air pump The air pump is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the air pump can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the air pump as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of Separation distance according to frequency of transmitter m transmitter W 150 khz to 80 MHz d = 1,2 80 MHz to 800 MHz d = 1,2 800 MHz to 2,5 GHz d = 2,3 0,01 0,12 0,12 0,23 0,1 0,38 0,38 0,73 1 1,2 1,2 2,3 10 3,8 3,8 7,3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 7

Guidance and manufacturer s declaration electromagnetic immunity The air pump is intended for use in the electromagnetic environment specified below. user of the air pump is responsible for making sure it is used in such an environment. Immunity test IEC 60601 Electrostatic discharge (ESD) IEC 61000-4-2 Electrical fast transient/burst IEC 61000-4-4 Surge IEC 61000-4-5 Interruptions and voltage variations on power supply input lines IEC 61000-4-11 test level 6 kv contact 8 kv air 2 kv for power supply lines 1 kv for input/output Lines 1 kv line(s) to line(s) 2 kv line(s) to earth <5 % UT (>95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles The customer or Compliance level Electromagnetic environment 6 kv contact 8 kv air 2 kv for power supply lines 1 kv for input/output lines 1 kv line(s) to line(s) 2 kv line(s) to earth <5 % UT (>95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. The Main power quality should be that of a typical commercial or hospital environment. The Main power quality should be that of a typical commercial or hospital environment. The Main power quality should be that of a typical commercial or hospital environment. If the user of the air pump requires continued operation during power interruptions it is recommended that the air pump is powered from an uninterruptible power supply or a battery. Power frequency (50/60 Hz) magnetic field <5 % UT (>95 % dip in UT) for 5 sec 3 A/m 3 A/m <5 % UT (>95 % dip in UT) for 5 sec Power frequency magnetic fields should be at levels characteristic of a typical commercial or hospital environment. IEC 61000-4-8 NOTE: UT is the a.c. mains voltage prior to application of the test level. 8

Guidance and manufacturer s declaration electromagnetic immunity The air pump is intended for use in the electromagnetic environment specified below. The customer or the user of the air pump is responsible for making sure it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the air pump, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF IEC 61000-4-6 3 Vrms 150 khz to 80 MHz 3 Vrms Recommended separation distance d = 1,2 Radiated RF IEC 61000-4-3 3 V/m 80 MHz to 2,5 GHz 3 V/m d = 1,2 d = 2,3 80 MHz to 800 MHz 800 MHz to 2,5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range b. Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless), telephones, land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the air pump is used exceeds the applicable RF compliance level above the air pump should be observed to verify normal operation. If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the air pump. b. Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m. 9

9. Warranty Prius Healthcare guarantees this equipment to be free from defects in material and workmanship for up to 12 months from the date of delivery. All warranty work will be performed at the service address below, shipping charges prepaid. At Manufacturers descreton we agree to service, repair or replace any equipment or part found to be defective at no charge. This warranty excludes equipment damaged through shipping, tampering, improper maintenance, carelessness, accident, negligence, misuse, or which has been altered, repaired or dismantled other than with the manufacture s written authorization and by its approved procedures and by properly qualified technicians. In no event shall Prius Healthcare be liable for any direct, indirect or consequential damage or loss resulting from the use of equipment. Warranty is non-transferrable. 10

Prius Healthcare USA 580 Corporate Center 4029 Tampa Road, #4000C Oldsmar, FL 34677, USA TEL: (813)854-5464 FAX: (813)854-5442 1 AL300099 V1.00