Catalytic Bead DrägerSensors for Fixed Gas Detectors

Similar documents
Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger REGARD -1 Control System

Dräger X-am 5000 Multi-Gas Detection

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger PEX 3000 Flammable Gas Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Pac 6000 Single-Gas Detector

Dräger X-am 2500 Multi-Gas Detector

Dräger Pac 8500 Single-Gas Detector

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger X-am 2500 Multi-Gas Detection

Dräger DM-6 BG 4 Mask Dryer Workshop Systems

Dräger X-am 5000 Multi-Gas Detector

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger Polytron SE Ex Fixed Gas Detector

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger REGARD -1 Control System

Dräger Pac 3500 Single-Gas Detection Device

Dräger Flame 2100 Flame Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Bump Test Station Calibration and Bump Testing

Dräger X-zone 5500 Area Monitoring

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Pac 5500 Single-Gas Detection Device

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Pac 6000 Single-Gas Detection Device

D D D Dräger Gas Detection ST Dräger: Technology for Life

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger Flame 2500 Flame Detection

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger REGARD -1 Control System

Dräger Pac 8500 Single-Gas Detection Device

Dräger PIR 7000 Flammable Gas Detection

Dräger QuadGard Control System

Dräger Exterior Live Fire Training System (ELFTS-C), the CAR

Dräger Configuration and Evaluation Software

Dräger Pac 8000 Single-Gas Detection Device

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Exterior Live Fire Training System (ELFTS) the QUAD

Dräger AFS 3000 Aircraft Fire Simulator

Training Authorised Gas Tester Level 1. Basic Information

Dräger REGARD 3900 Series Control System

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Dräger Polytron 5720 IR Detection of carbon dioxide

Training Gas Detection Level 2 User and Calibration. Basic Information

GS01 (wireless) Detection of flammable gases and vapours

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger PIR 7200 Detection of toxic gases and oxygen

On-site & Shutdown Safety Service CSE Monitoring

Dräger Pac 3500 Single-Gas Detection Device

Training Gas Detection Level 3 Maintenance and Repair

Dräger UCF 7000 Thermal Imaging Camera

Dräger Pac 7000 Single-Gas Detection Device

Dräger X-am 7000 Multi-Gas Detection

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron 8310 Stationary gas detector (DSIR)

SIL 2. Ultima X Series Gas Monitors CERTIFIED

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger X-zone 5500 Area Monitoring

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 5000 Flame Detection

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger Flame 2370 (UV&IR) Flame Detection

D At your side in oil and gas exploration

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

ST Explosion Protection GAS DETECTION SYSTEMS

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Application Note. Gas Turbines. Introduction. Market Segments

Dräger OR Lights Simply good light

ST More than the sum of their components GAS DETECTION SYSTEMS

Properly calibrating catalytic bead sensors: A practical guide

Dräger VVP 1000 System Components

Dräger X-zone 5500 Multi-Gas Detection Device

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger Polytron 7000 Fixed gas detector

Products and performance

ST Safety to go. DRÄGER PORTABLE GAS DETECTION INSTRUMENTS

Dräger Flame 5000 Flame Detection

Transcription:

Catalytic Bead DrägerSensors for Fixed Gas Detectors Measuring combustible gases and vapors is essential for the safety of your people and your facilities. Intended for Dräger's fixed gas detectors, Catalytic Bead DrägerSensors are designed for continuous monitoring and detection of combustible gases and vapors with different versions for different applications and concentrations. ST-7769-2005

02 Catalytic Bead DrägerSensors Benefits Catalytic bead technology: the choice for potentially explosive environments Catalytic Bead DrägerSensors are based on the catalytic bead detection principle, one of the only technology acknowledged in the industry for detecting and measuring detection principle for combustible gases such as hydrogen. Performance in extreme environments Catalytic Bead DrägerSensors Ex PR M for poisonous substances Catalytic Bead DrägerSensors Ex PR M contain pellistors that show longer endurance under the influence of poison substances than conventional types. Catalytic Bead DrägerSensors Ex HT M for high temperature environments Catalytic Bead DrägerSensors Ex HT M contain PR pellistors and are approved for temperatures of up to 302 F/150 C. Catalytic Bead DrägerSensors Ex LC M for detecting low gas concentrations Catalytic Bead DrägerSensors Ex LC M contain PR pellistors that allow for the detection of very low gas concentrations by their special arrangement and amplifier electronics. The measuring range is 0 10% LEL. Innovation Double Detector Measuring The DrägerSensor achieves optimum compensation by using the patented Double Detector principle with 2 active pellistors to reduce measurement drifts between the detector and compensator. The better the compensation, the better the performance. The gas permeable explosion-proof encapsulation is not achieved by a sinter disc, but by a thin wire mesh. The thickness of the wire mesh disc is only 0.08 mm. The diffusion path length is approximately the same distance. Shorter diffusion paths mean faster response times. DrägerSensors, Polytron and REGARD are trademarks of Dräger.

Catalytic Bead DrägerSensors 03 Accessories Calibration Chamber This metal chamber is designed to vaporize combustile liquids such as acetone, benzene, hexane, nonane, etc. Used for zero-point tests and calibration. Part number: 68 02 206 ST-5678-2006 ST-5654-2006 Calibration Adapter This adapter is designed for zero-point tests and calibration of transmitters with electrochemical sensors (not type L), catalytic sensors (pellistors) and Polytron IR CO 2 and Polytron IR Ex HC. Part number: 68 06 978 Remote Calibration Adapter This adapter is designed for calibration of transmitters with electrochemical sensors (not type L), catalytic sensors (pellistors) and Polytron IR CO 2 and Polytron IR Ex HC type transmitters that are mounted in difficult to access locations. Part number: 68 07 955 ST-5687-2006 ST-5679-2006 Splash Guards These units protect the DrägerSensors of transmitters with electrochemical sensors (not type L), catalytic sensors (pellistors) and Polytron IR CO 2 and Polytron IR Ex HC type transmitters against splashing water. Part number: 68 07 549

04 Catalytic Bead DrägerSensors Services Dräger Service When your operation s safety equipment is backed by over 125 years of experience and supported by the same team that engineered it, you can rely on service and rental solutions that are tailored to meet your unique needs. With Dräger s safety solutions, you get complete peace of mind, budget security, and full-service support that you can count on every step of the way. That s the Dräger Service Advantage. D-19072-2016 Related Products DrägerSensor IR Upgrade to infrared technology in an instant. The DrägerSensor IR can replace catalytic Ex sensors (catalytic bead sensors, pellistors) without additional installation work. ST-3831-2003 ST-8821-2005 Electrochemical (EC) DrägerSensors When you need to selectively measure the smallest concentrations of airborne toxic gases and oxygen under ambient conditions, Electrochemical DrägerSensors are your answer. These long-life EC sensors for Dräger transmitters offer fast response times, high accuracy, and unmatched stability.

Notes Catalytic Bead DrägerSensors 05

06 Catalytic Bead DrägerSensors Notes Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. 91 03 411 17.09-2 HQ PP Subject to modifications 2017 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Customer Service: USA +1 800-4DRAGER (+1 800-437-2437). CANADA +1 877-DRAGER1 (+1 877-372-4371). Technical Service: USA +1 800-4DRAGER (+1 800-437-2437). Locate your Regional Sales Representative at: www.draeger.com/contact