WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

Similar documents
USERS GUIDE 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USER GUIDE VOGUE MAX SYSTEM

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USER GUIDE LOGIC HEAT H

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Logic+ Combi

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

2 Minimiser SE - User's

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

MURELLE EV HE 25/55-30/55

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

ir-range 8G /03.15 Changes reserved.

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

User s Operation Instructions & Important Warranty Information

Combi Eco Elite Range. User s Guide and Important Warranty Information

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

User Guide. Promax SL Condensing Central Heating Boiler

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

GB24 & GB30. User Manual

Avanta 12v - 15v - 18v - 24v - 30v

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Open Vented Condensing Boilers

Baxi Maxflow Combi WM

Osprey 2 CFL

condens Instructions for Use Ultracom 2 35 Store G.C. No

Baxi Maxflow Combi FS

AQUAIR S SERIES. of Water to Air Space Heaters INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONSS. Aquair S-10 Aquair S-16 Aquair S-20

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

User's Instructions. Alpha CB50

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

Greenstar 12i/24i System

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

HI-SPEC J25SCA. Warm Air Heater. System E-T Control & Eljan 4/SEA Water Circulator INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS

GREENSTAR HIGHFLOW 440/550CDi

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

24CDi, 28CDi & 35CDi II COMBI

BUILDING REGULATIONS PART L

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

Operating instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATED AIR OUTLET HEATER CONTROL PANEL

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

GREENSTAR HIGHFLOW 440/550CDi

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

Greenstar 12i system / 24i system

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Warm Air Central Heating

VIESMANN. Operating instructions VITODENS 100-W. for the system user

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

Operating instructions

VIESMANN. Operating instructions VITODENS 111-W. for the system user

Operating instructions

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

ECONOMAIRE 32. Warm Air Heater. with Intejan Water Circulator INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS

User Guide Combi. Condensing Combination Boiler

iheat 25c iheat 30c iheat 35c

User Guide. Gold Combi Condensing Combination Boiler

E-Combi One E-System ONE

Gas Condensing Boilers

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

Vote for your Installer of the year at HEATSLAVE

Greenstar 24i junior / 28i junior

USERS MANUAL FOR GAS BOILERS

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

Transcription:

WARMCAIR Condensing Air & Water Heater Publication No. ZZ 1449-2 September 2016 High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS Warmcair C10DW - G.C. No. 43-417-59 Warmcair C16DW - G.C. No. 43-417-60 Warmcair C20DW - G.C. No. 43-417-61 These instructions are to be left with the User www.johnsonandstarley.co.uk

CONTENTS 1 General Information 3 2 Temperature Conrol 3 3 Air Filter 3 4 Maintenance 4 5 Heater Not Giving the Service Required 4 6 The Heater Control Panel 4 7 To Light the Heater 5 8 Operating Functions 5 9 Reset Procedure 6 10 Servicing & Maintenance 6 11 Escape of Gas 6 12 Cleaning 6 13 Trouble Shooting 6 14 Important Information 7 NOTE This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER AFTER INSTALLATION The Benchmark Scheme Johnson & Starley Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales). All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist. This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. The Benchmark Checklist will be required in the event of any warranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Improvements. In the interest of continuous development Johnson and Starley reserve the right to change specification without prior notice. Johnson and Starley prides itself on it s ability to supply spare parts quickly and efficiently. 2 www.johnsonandstarley.co.uk

1. GENERAL INFORMATION WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: IT IS A STATUTORY REQUIREMENT THAT ALL GAS APPLIANCES BE INSTALLED BY COMPETENT PERSONS, (i.e. GAS SAFE REGISTERED INSTALLERS. GAS SAFE MEMBERSHIP ENQUIRIES - TEL: 0800 408 5500) IN ACCORDANCE WITH THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS (CURRENT EDITION). FAILURE TO COMPLY WITH THESE REGULATIONS MAY RESULT IN PROSECUTION. Part of the installation and commissioning of this appliance is related to instructions for use by the heating engineer to the user where specific requirements may occur. The Warmcair is a floor mounted, condensing heater, featuring full sequence automatic spark ignition and fan assisted combustion. Due to the high efficiency of the heater, condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the heater. A condensate plume will also be visible at the flue terminal. 2. TEMPERATURE CONTROL 2.1 THERMISTA-STAT OPERATION 2.1.1 The numbers on the Thermista-stat dial represent levels of warmth. When you select a number, the heater will automatically operate to maintain this level. You will soon find the setting with which you are most comfortable, and it is suggested that you start at mark 6, making adjustments up or down until a satisfactory level is reached. 2.2 ROOM THERMOSTAT OPERATION (optional) 2.2.1 The room thermostat enables you to select the room temperature that you require. When the air temperature surrounding the thermostat reaches the selected temperature, the thermostat will switch the heater off. The thermostat will then automatically allow the heater to cycle on and off to maintain the selected room temperature. 2.3 CONTROL OF YOUR HEATING SYSTEM 2.3.1 You can control the heat to each room by opening and closing the warm air outlets, but not more than half of these outlets should be closed at any one time or the performance of the heating system may be adversely affected. 2.3.2 Warm air outlets in the room where the Thermista-stat or room thermostat is sited should always be left open to ensure that the heating system is properly controlled. 2.4 SUMMER AIR CIRCULATION (if fitted) 2.4.1 During hot weather, unheated air can be circulated around the home, by turning the heating requirement off and setting the SUMMER AIR CIRCULATION SWITCH to ON. This switches the heater s fan on, and circulates air around the home through the air outlets. 2.5 ECONOMIC OPERATION 2.5.1 The best economy is achieved by setting the Thermista-stat or room thermostat to the lowest setting that you find acceptable. 2.5.2 Overnight in prolonged severe weather, it is better to set the air heater TIME CONTROL (if fitted), to ON ALL TIME, and reduce the Thermista-stat or room thermostat setting to provide general background heating. Resetting the controls to normal settings on rising will quickly raise the room temperature. a) Recommended background heating settings: Thermista-stat: Mark 4 Room thermostat: 13 C (55 F) 3. AIR FILTER IMPORTANT: The air filter should be cleaned every two weeks during the heating season, or every week for the first month in new homes to clear builder s dust etc. 3.1 To clean the air filter, withdraw it from the heater and clean it using either a soft brush or vacuum cleaner before refitting it to the heater. DO NOT allow the filter to become clogged, or the heater output will be greatly reduced and fuel will be wasted. Do not use the heater without a filter. Sales/Spares & Replacement Help Line 01604 762881 3

4. MAINTENANCE 4.1 It is recommended that a full maintenance check on your appliance is made annually, and that a service contract is taken out on completion of the guarantee period. Your installer will give you details of arrangements for this service. If your installer has difficulty in providing this information, please contact Johnson & Starley Service department, who will provide information of suitable service companies. 5. HEATER NOT GIVING THE SERVICE YOU NEED 5.1 Check that the Thermista-stat or room thermostat and time control (if fitted) are correctly set to your requirements, and at least half of the warm air outlets are open, especially in the room where the temperature control is sited. 5.2 Check if the air filter is clogged, and clean as instructed in Section 2. 5.3 If the fan will not slow down or stop at any time, ensure that the summer air circulation switch (if fitted) is set to OFF. 5.4 SERVICE ARRANGEMENTS NEW APPLIANCES Service is supplied under guarantee by the installer for an agreed period, thereafter, should you have difficulty in obtaining service, Johnson and Starley Service Department will provide information of suitable service companies. 6. THE HEATER CONTROL PANEL TABLE 1 Description K1 + Installer function only K2 - Installer function only K1 K7 K3 K4 Installer information Reset K2 K6 K5 K6 - Summer/Winter mode K3 K5 K7 - K4 FIGURE 2. LED DISPLAY FUNCTIONS 4 www.johnsonandstarley.co.uk

7. TO LIGHT THE BOILER 7.1 Switch the mains power ON and the boiler LED display will show AP. This puts the boiler into the Air Purge Mode. See Figure 3. 7.2 Press the reset button K4 twice. The boiler will go onto standby. This is the winter mode. See Table 1. 7.3 SETTING THE WATER TEMPERATURE 7.3.1 To set the water heating temperature press and hold K1, this will flash until the C temperature shows. by pressing the + and - buttons to the desired temperature. The temperature flashes 5 time to set the temperature and the display will go back to standby. 8. OPERATING FUNCTIONS 8.1 OPERATING THE CENTRAL HEATING When the heater fires in CH mode it fires for 1 minute, modulating the heater. The display will flash showing the radiator, the small flame and temperature. A flame symbol increases with the demand for heat. Once temperature is reached the display will go back to standby. Approximate flow temperatures for the heater thermostat settings are: TABLE. 2 Button Setting CH Flow Temperature C Minimum 40 C Maximum 80 C 8.2 DISPLAY CODES In normal operation the heater status display will show codes: 1. Standby - no demand for heat. 2. CH being supplied. 3. Heater frost protection - heater will fire if temperature is below 5 degrees C. 4. During normal operation the burner on indicator will remain illuminated when the burner is lit. Note: If the heater fails to light after five attempts the fault code will be displayed. 8.3 TO SHUT DOWN THE BOILER Set the mode to OFF To relight the heater repeat the procedure detailed in To light the heater. 8.4 FROST PROTECTION If no system frost protection is provided and frost is likely during a short absence from home, leave the heating controls (if fitted) at a reduced temperature setting. For longer periods, the entire system should be drained. If the system includes a frost thermostat then, during cold weather, the boiler should be turned OFF at the time switch (if fitted) ONLY. The mains supply should be left switched ON, with the heater thermostat left in the normal running position. 8.5 CONDENSATE DRAIN The condensate drain must not be modified or blocked. Blockage of the condensate drain, caused by debris or freezing, can cause automatic shutdown of the heater. If freezing is suspected and the pipe run is accessible an attempt may be made to free the obstruction by pouring hot water over the exposed pipe and clearing any blockage from the end of the pipe. If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be sought. Sales/Spares & Replacement Help Line 01604 762881 5

9. RESET HEATER Press the reset button twice. See Table 1 Button K4. 10. SERVICING & MAINTENANCE It is recommended that a full maintenance check be carried out annually on the appliance. It is also recommended to take out a further service agreement on the expiry of the guarantee period. You can obtain further information on this from your gas supplier. The appliance should be checked /serviced by a GAS SAFE registered installer. If you require service on your appliance please contact your local installer or gas supplier. On completion of the service the installer should fill in the service section at the rear of the BENCHMARK log book. All installers registered with GAS SAFE carry an identification card. This card will have an ID number which should be recorded in your logbook. If you have any queries regarding your installer you can contact GAS SAFE by telephone on 0800 408 5500. The appliance should be serviced at least once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). 11. ESCAPE OF GAS Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay. Telephone 0800 111 999 Do NOT search for gas leaks with a naked flame. 12. CLEANING For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth. DO NOT use abrasive cleaning materials. 13. TROUBLE SHOOTING 13.1 Check that the Thermista-stat and Time Control are set correctly to your requirements and that at least half of the warm air outlets are open, especially in the room where the Thermista-stat is located. 13.2 Check that the air filter is not clogged, if so clean as detailed in Section 8. 13.3 If there is a LOCKOUT error, wait for approximately 10 seconds and then press the RESET button. 13.4 If the heater will still not operate correctly, contact your local service engineer. Service arrangements: a. for new dwellings, servicing is usually supplied for a specific period under arrangements made by the building contractor. b. local Authorities often have their own special arrangements. c. if the above do not apply, contact your local service engineer, or the Service department at Johnson & Starley Ltd. 6 www.johnsonandstarley.co.uk

GAS LEAKS DO NOT OPERATE ANY ELECTRICAL SWITCHES, OR USE A NAKED FLAME - TURN OFF GAS SUPPLY VENTILATE THE AREA BY OPENING THE DOORS AND WINDOWS CALL THE NATIONAL GAS EMERGENCY SERVICES ON TEL: 0800 111999 14. IMPORTANT INFORMATION FOR YOUR HEATER TO WORK EFFICIENTLY AND FOR YOUR HEATING SYSTEM TO PERFORM SATISFACTORILY, IT IS ABSOLUTELY ESSENTIAL TO OBSERVE THE FOLLOWING: 1. DO KEEP CLEAN, and make sure you DO NOT OBSTRUCT any grilles on the heater, in the heater compartment, or in any walls, windows or doors of the building. 2. DO CLEAN AND REFIT the air filter at least once per month. 3. DO NOT PLACE ANYTHING (clothing, linen etc.) in contact with the air heater or its flue pipe. 4. DO NOT USE the heater compartment for storage or airing. 5. DO NOT turn off the mains electricity supply to the air heater until the gas supply has been turned off. NOTE: IF YOU ARE AWARE OF, OR SUSPECT, A FAULT OF ANY KIND THE HEATER MUST NOT BE USED. TURN OFF THE GAS AND ELECTRICAL SUPPLIES TO THE HEATER AND CONTACT YOUR SERVICE ENGINEER. Sales/Spares & Replacement Help Line 01604 762881 7

Johnson & Starley Ltd Rhosili Road, Brackmills, Northampton NN4 7LZ sales@johnsonandstarley.co.uk marketing@johnsonandstarley.co.uk Reception/Customer Service 01604 762881 Fax 01604 767408 Anniversary 1922-2012