ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

Similar documents
SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Indirect gas-fired air heater

Field Start-Up Sheet Direct Fired Gas Equipment

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

B SERIES ELECTRIC FURNACE

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

Electric Coils. Blower Coils. Product Information

Installation Instructions

Installation instructions for Plenum-mounted add-on electric heaters

MODELS B1PA024, 030 AND 036

INDIRECT GAS FIRED AIR HEATERS LD(E) SERIES. Model 120, 180, 240, 300, 350 and 400 outdoor INSTALLATION AND SERVICE MANUAL

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Installation Instructions Remote Blowers

Visit our web site at

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

FEATURES AND BENEFITS

USER S INFORMATION MANUAL

Direct Fired Heater Model AD Specification

Construction Electrical

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

ML180UH SERIES GAS FURNACE WARNING WARNING

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

MANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved.

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Commercial Maintenance Agreement (CMA) Benefits

Installation Instructions Wall Ovens

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

INSTALLATION INSTRUCTIONS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA)

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

INDIRECT GAS-FIRED AIR HEATER

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

USER S INFORMATION MANUAL (2,4)SG13B

Standard and Modular Electric Heaters and Inserts Installation, Operation, and Maintenance Manual. Modular Electric Heater

Cambridge Engineering, Inc. 24 S-Series Technical Manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Installation Instructions

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

ULTRA-SAFE Explosion-proof Duct Heaters

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

48TM GAS HEATING/ELECTRIC COOLING UNITS

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

Standard and Modular Electric Heaters and Inserts Installation, Operation, and Maintenance Manual. Modular Electric Heater

EL195UHE SERIES GAS FURNACE WARNING WARNING

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

USER'S MANUAL PGE Single Package Rooftop

HRV Vertical Unit Ventilators

Standard and Modular Electric Heaters and Inserts Installation, Operation, and Maintenance Manual. Modular Electric Heater

Gas-Fired Indoor and Outdoor Duct Furnaces

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER

INSTALLATION INSTRUCTIONS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

DIVISION FINNED WATER-TUBE BOILERS

EC Series Wall Unit Humidifier

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

WARNING FIRE OR EXPLOSION HAZARD.

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

MILLA ELECTRIC FIREPLACE

WARNING FIRE OR EXPLOSION HAZARD.

Quest Power Electric Heat EHS 31 Pro

Models: Comfort SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20. Advantage SUPXX-A120D12 SUPXX-A240D12 SUPXX-A120D20 SUPXX-A240D20

Installation & Maintenance Instructions

Installation Instructions

Installation, Operating & Maintenance Instructions. Air Handler Models: AH & AV

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Installation Instructions

ARM SERIES Switching Relays With Priority

EL296UHV SERIES GAS FURNACE WARNING WARNING

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

50TM TFF COMBINATION HEATING/COOLING UNITS

EVO192 v3.0 Fire and Burglary What s New

SECTION (15767) - UNIT HEATERS

Bosch 80% AFUE Gas Furnace BGS80 Model

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

50TM COMBINATION HEATING/COOLING UNITS

Equipment Maintenance Checklist

Custom Duct Heaters. Special Applications

READ AND SAVE THESE INSTRUCTIONS

Horizontal & Horizontal Quiet Blower Coils

Electric Duct Heaters. IDHB & IDHC Series

EL195DFE SERIES GAS FURNACE WARNING

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Transcription:

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL BC(E) SERIES INDOOR / OUTDOOR MANUFACTURED BY

GENERAL INFORMATION PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: TELEPHONE: INSTALLATION DATE: MANUFACTURER: BOUSQUET TECHNOLOGIES INC. ADDRESS: 2121, NOBEL, SAINTE-JULIE (QUÉBEC) J3E 1Z9 TELEPHONE: 514 874-9050 / 1-800-363-9197 FAX: 450 649-8756 WEB SITE: WWW.BOUSQUET.CA THIS INSTRUCTION MANUAL MUST ALWAYS BE READABLE AND KEPT IN THE HEATER AT ALL TIMES.

TABLE OF CONTENTS INSTALLATION STANDARDS 4 INSTALLATION INSTRUCTIONS 5 ELECTRICAL WIRING 6 WIRING SEQUENCE 8 START UP INSTRUCTIONS 9 ELECTRIC HEATING COIL S FEATURES 9 OPERATING SEQUENCE 10 AIR HEATER MAINTENANCE 11 AIR HEATER SHUT OFF 12 TEMPERATURE CONTROL TOOLS 13 ELECTRICAL COMPONENTS 13 START UP REPORT 15 TABLE LISTING MINIMAL CLEAREANCE FOR SERVICE 5 FIGURE LISTING INSTALLATION INSTRUCTIONS 5

INSTALLATION STANDARDS The installation of this air heater must comply with the relevant installation codes such as the Canadian Electrical Code (CSA C22.1) and the standard ANSI/NFPA 70. All internal and external electrical installations must comply with the electrical diagrams of the unit. (To find out more, please refer to the Operating sequence which can be found in the Start up instructions section.) The tightening of the connections must be verified before start up as well as after a short period of operation (typically, after 2 weeks). The grounding of the unit must be done properly. 4

INSTALLATION INSTRUCTIONS Sealing joints (Scellant & screws) Fan / Motor Access door Controls access door Damper actuator Access panel MINIMUM CLEARANCE FOR SERVICE AND MAINTENANCE 18 (457mm) 36 (915mm) 5

The air intake must be located and oriented in order to prevent the infiltration of snow, rain and flammable toxic gas, as well as any other harmful material into the make-up air heater. When the heater is hung over a working area, it must be installed at an adequate height and sitting on an independent structure. For indoor installation, please refer to current local installation code. When firewall dampers are used in the ducts they must be equipped with an electric switch wired to the safety control circuit of the unit in order to shut down the air heater when fire is detected. These electric switches must be wired to re-activate the safety circuit only when the firewall dampers are completely open.. In order to prevent any risk of freezing, the installer must install a low temperature sensor if not supplied with the unit. If the unit requires outdoor air, it is recommended to install a low limit sensor to prevent freezing. ELECTRICAL WIRING WARNING If the original wiring needs to be changed or modified, the replacement wiring must be of the same size and must be certified CSA, UL, TEW or AWM 105 ºC. The conductors installed in the air flow of this unit must be an integral part of a metallic cable or be enclosed in a duct, in an electrical metallic tube or in metallic pipes. DANGER For safety reasons, all modifications or alterations to the electrical internal connections or to the electrical coil s components are strictly forbidden. All unauthorised modifications will void the warranty. This unit runs on high voltage. Electrical installation of this unit must be performed by a qualified electrician. RISK OF ELECTRIC SHOCK. Make sure that the electrical supply is disconnected before working on the unit. 6

Compliance of electrical installation CAUTION: A disconnect with or without protective fuses must be installed if they are not present on the control panel of the electric coil. CAUTION: The supply wires must be of an appropriate diameter, according to the current intensity. It is indicated on the nameplate of the manufacturer (MCA). Normal operating conditions AIR FLOW: The air flow must never be lower than the minimum indicated on the descriptive plate. No combustible particle, vapour of flammable gas must ever be present in the air flowing in the electric coil. The air flowing in the electric coil must be dust free. Filters of a minimum 3.0% efficiency are required. Maintenance The electric coil does not require any particular maintenance; however, we recommend an annual inspection: 1) VISUAL INSPECTION CAUTION DISCONNECT THE COIL S ELECTRICAL SUPPLY BEFORE ANY VISUAL INSPECTION. Check the condition of the heating elements. Pay special attention to the presence of dust accumulations which can cause damages to the electric coil. Check for corrosion or overheating signs on the frame. 7

2) ELECTRICAL INSPECTION CAUTION DISCONNECT THE COIL S ELECTRICAL SUPPLY BEFORE ANY ELECTRICAL INSPECTION. Check the condition and tightening of all electrical connections. Make sure the protective fuses are in good working order. Verify the resistance of each circuit against ground. Any electrical component replacement must be made with original components. WIRING SEQUENCE a) The nameplate of the unit gives the total voltage and amperage required. The main electrical supply cable must be well sized to accommodate these criteria. b) The main cable must be connected to the disconnect or the main power terminal strip. Make sure the tightening screws of the disconnect are well tightened. c) Connect the remote control panel (optional) to the strips provided in the main control box of the unit. d) Connect the remote temperature sensors (optional). Make sure the connection wires used are shielded (with metal sheathing). 8

BLOWER ADUJSTMENT START UP INSTRUCTIONS Check the voltage at the main electrical disconnect. Check the fan s rotation direction and modify the electrical connection if required. Ensure that the contactor s overload relays are set according to the full load amperage (FLA) as indicated on the motor s nameplate. Check the belts alignment and tension. Measure the amperage on each phase of the motor. This information must be specified on the service report. Balance the air flow in the unit and adjust pulleys consequently. ELECTRIC HEATING COIL S FEATURES The standard open elements coils are made of a NiCr 60 (grade C) alloy: 60% Nickel, 16% chrome and the rest is iron. With this type of alloy, the maximum operation temperature is of 1,850 F (1000 C). Operation: An electric signal coming from a modulating thermostat is transmitted to the HEC controller. The HEC controller activates the first modulating stages of the electric coil. The superior stages are generally of the "Open / Close" type and are activated successively by the HEC controller. The HEC controller accepts many types of entry signals used in the industry and converts them into a modulating signal or by stages to transfer them to the SSR and to the contactors. This controller ensures a superior precision by precisely measuring the air speed and by updating continuously the signal transmitted to the electric coil. Types of entry signals accepted by the controller: 0-10VDC 4-20 ma 9

OPERATING SEQUENCE Operating sequence of a SINGLE VOLUME unit (for reference only) BLOWER S START-UP 1 - Place the selector (OFF/BLOWER/HEATING) on the BLOWER position. 2 - Fresh air damper opens. 3 - The damper s opening proof contact shuts off. 4 - The contactor of the blower s motor is powered. 5 - The blower is in operation. ELECTRIC HEATING COIL S START-UP 1- Place the selector (OFF/BLOWER/HEATING) on the HEATING position. 2- Fresh air damper opens. 3- The damper s opening proof contact shuts off. 4- The contactor of the blower s motor is powered. 5- The blower is in operation. 6- The air flow switch s contact shuts off. 7- If the manual and automatic high limit temperature sensors are closed, the Modulating controller (SCR) is powered. 8- The modulating controller fluctuates proportionally according to the temperature sensor s reading to reach the desired temperature. 10

AIR HEATER MAINTENANCE CHECK LIST Check filters; change if necessary Ensure that no combustible materials are stored near the unit Ensure that nothing blocks the air inlet and outlet of the unit Check the belts and adjust or change them if necessary Lubricate the blower and motor s bearings as needed Check the full opening of fresh air dampers Ensure that all security controls are in good working order Check maximum temperature thermostat Check all electrical connections Ensure that the blower and motor are firmly attached PERIODICITY WEEKLY MONTHLY SEMESTRAL ANNUALL Y IMPORTANT BEFORE START-UP AND AFTER 8 HOURS OF OPERATION 1) Check the alignment and lubrication of the bearings 2) Check the bearing s tightening rings 3) Check the alignment and tension of the belts AFTER 24 HOURS OF OPERATION Check the tension of the belts 11

PROLONGED SHUTDOWN AIR HEATER SHUT OFF When the unit is not being used for a long period of time, it is recommended to cut the electrical supply. Before starting up the unit after a long shutdown, it is recommended to fully inspect it in order to ensure that everything is in working order. EMERGENCY SHUT DOWN OF THE AIR HEATER When it becomes necessary to shut down the unit in an emergency situation, you must place the main disconnect switch on "OFF". RESTARTING THE UNIT AFTER A SHUT DOWN Following a shut down of the unit, perform the following verifications: 1) Place the disconnect switch on "OFF". 2) Verify, replace or adjust, if necessary, the fan s belts. 3) Verify the condition of the filters and replace them if necessary. 4) Ensure that nothing blocks the air inlets and outlets of the unit. 5) Ensure that nothing keeps the air inlet and outlet dampers of the unit from functioning properly. 6) Place the disconnect switch on "ON". 7) Ensure that the blower s motor is functioning. 8) Ensure that the electric coil is functioning. 12

TEMPERATURE CONTROL TOOLS Duct temperature sensor Installed at the blower s discharge or in the returned air, it ensures an accurate reading of the supplied air temperature. Room temperature sensor Installed in the room, it ensures an accurate reading of the room temperature and allows to adjust the supplied air temperature according to the request. Room or duct temperature selector The temperature selector can be installed either in the unit s control box or in the remote control panel ( M series). It offers a large range of temperature s set points. Air low limit thermostat and sensor The air low limit thermostat stops the unit if the supplied air temperature is below 40 F for more than 300 seconds. (Optional) ELECTRICAL COMPONENTS HEC Electronic controller The HEC changes a modulating signal into a proportional signal and sends it to the SSR to modify the heating capacity of the electric coil. The control signals are: 0-10 VDC and 4-20 ma provided by the room or duct thermostat and the air flow thermostat of the unit. Electronic relay (SSR) with a thyristor (SCR) Controls proportionally the amount of power transferred to the electric coil according to the HEC controller's signal. Transformers Two transformers are provided for controls and power. 13

High limit air temperature sensor with automatic reset Used to prevent the electric coil from overheating (installed near the electric coil and set at 160 F). High limit air temperature with manual reset Used to prevent from getting a supplied air temperature too warm (installed near the blower and set at 160 F). Air pressure controller Automatically turns off the electric coil when the air pressure goes below the set points. Fuses Fuses assure the controls security. Additional fuses assure the electric coil s security when required by the local code (USA). Main electrical disconnect switch The disconnect switch is installed in the control box with a proof of operation to prevent the electric coil to be in heating mode when the door is open. Programmable timer clock (7 days / 24 hours; mode: «Day / Night») The timer clock allows to program ventilation and heating sequence to accommodate the needs of the building. 14

ELECTRIC AIR HEATER BC(E) SERIES START UP REPORT 2121, Nobel Ste-Julie, Quebec J3E 1Z9 Tel: (514) 874-9050 - Toll free: 1 (800) 363-9197 Fax: (450) 649-8756 Company: Technician: Installer: Project: Project s representative: Address: MANUFACTURING INFORMATION Model Number: Overload: Amps Serial Number: Belts: Blower: / Motor s pulley: Pulley s C-C: (+ - ) Blower s pulley: INSPECTION Note: Air conduits installed: Air intake hood installed (screws and sealant): Main electrical connection completed: Blower s rotation checked: Remote control panel installed: Interlock checked: Belts tension verified: Interlock type : START UP Amps supply: Measured voltage: Ph 1 Ph 2 Ph 3 Ph 1 Ph 2 Ph 3 ADJUSTMENTS Blower rotation speed RPM Electric coil modulation verified Supply temperature º F Complete unit sequence verified Low limit thermostat º F Low limit delay: sec. High limit thermostat º F Damper actuator VDC Inlet thermostat º F O/A end limit switch % Start up completed: If not, for what reasons (or other comments): Signature : Date : *** RETURN TO MANUFACTURER BY FAX AT 450 649-8756 *** 15