GLAS. Installation Instructions

Similar documents
TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Smart THERMOSTAT. Installation Manual

How to install your ecobee4

Smart Hub THERMOSTAT. Installation Manual

ecobee 3 Quick Start Guide Installation Guide DRAFT

Compatibility. Contents. Necessary Tools

Technical support is also available by or by phone: (North America) (International)

2 x screws. 2 x wall plugs

Quick Start & Setup Guide

How to install your ecobee4

Optima ZigBee Thermostat

ShockLink. Important Product Information.

with Wi-Fi and local API Quick start and setup guide

Wi-Fi DOOR/WINDOW SENSOR

T5+ Smart Thermostat Programmable Thermostat RCHT8610WF, RCHT8612WF

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

ADC-T2000. Smart Thermostat v1.5

Automatic Dimming Mirror with HomeLink

Pet Immune SAW PIR Motion Sensor

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Install Guide 3M-10 ENGLISH

PRO Installation. Touch Wi-Fi Thermostat

Smart Si Thermostat. Installation Manual

PRO Installation. Thermostat Wi-Fi

ADT. Pulse 2017ADT LLC

Rev D 3/20/17

PRO Installation. Touch Wi-Fi Thermostat

GARAGE DOOR OPENER KIT

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 6 Mounting 7 Probe Use 8 Probe Wrap Use 9

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Lyric T6 Pro Wi-Fi. Professional Install Guide. Compatibility. Customer assistance. Programmable Thermostat

Wireless Outdoor Air Reset Adaptor PN:

OPTIMA ZigBee Thermostat

Installation Instructions HEAT COOL FAN POWER

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

Install Guide Customer Support: or Visit our website

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Door/Window Sensor Installation Instructions

Installer Guide smart connect

Safety & Installation Instructions

SZ-PIR04N ZigBee Motion Detector Installation Guide

Installer Guide smart connect

PET IMMUNE PIR MOTION DETECTOR

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 7 Mounting 7 Probe Use 8 Probe Wrap Use 9

Sensi Wi-Fi Thermostat. 1F87U-42WF Installation Training

Touchscreen Comfort Control

Premier 2-Zone Controller model Installer Guide

BE1310 Visit Smart hub

Atomic Digital Office Clock

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

7-Day. Digital Thermostat. residential. & 2-cool

Universal Wireless Thermostat Kit. * Wireless Humidity Control requires accessory model 7330.

InTemp CX Temperature Logger (CX40x) Manual

Nest x Yale Lock Programming/Troubleshooting Guide

Powerley Thermostat. Installation & Operation Guide

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Wireless Weather Station

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Programmable Thermostat

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Quick Start Guide. Wi-Fi Color Touchscreen Programmable Thermostat. RTH9590 Wi-Fi With Voice Control

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Common Maker Troubleshooting

EcoView Thermostat. Product Description. Installation. Product Number. Caution Notations. Required Tools. Expected Installation Time.

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

1F98EZ-1421, Easy Install

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Safety & Installation Instructions

Nest Thermostat E Pro Installation & Configuration Guide

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Programmable Thermostat

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

Universal Programmable Smart Wi-Fi Thermostat Up to 3 Heat / 2 Cool Heat Pump Up to 2 Heat / 2 Cool Conventional with wireless Humidity Control*

Small Digital Thermostat Controller Temperature Control

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

SMART THERMOSTAT Installation Manual

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

Safety & Installation Instructions

Wireless External Alarm

Smart Radon Detector with Indoor Air Quality Sensors

NP100 Non-Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

CAUTION. FCC Compliance Statement

How to install your Nest Protect

Note the wire colors and letter designations of the existing thermostat to assist in identifying the correct wiring connections to the TS200.

Features and content. This is where air comes into your detector.

PECO. WavePRO Wireless System INSTALLATION GUIDE: T2500 THERMOSTAT AND R2500 RECEIVER. The Peco WavePRO Wireless System

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Transcription:

LAS Installation Instructions

Support If at any point you need assistance, we re here to help. Visit www.glas.johnsoncontrols.com/support for how-to videos and frequently asked questions. an t find what you re looking for? ive us a call at 1-833-297-4527(LAS) and our technical team can walk you through it. Before you start, download the LAS app for easy installation. oogle Play and the oogle Play Logo are marks and/or registered marks of oogle LL. Apple, the Apple Logo and App Store are marks and/or registered marks of Apple Inc. LAS smart thermostat installation instructions - 2018 Johnson ontrols 1

Included in the box LAS smart thermostat Air seal Wall plate -wire adapter 2x 1-1 /2" Pan-head Phillips screws 2x 1" Pan-head Phillips screws 2x 1" Flat-head Phillips screws 4x Drywall anchors Wiring stickers Tools required Quick start guide Screwdriver Drill with 1/4" bit Level 2 LAS smart thermostat installation instructions - 2018 Johnson ontrols

ompatibility LAS is compatible with most 24 VA heating and cooling systems. Use the compatibility checker to ensure your system will work with LAS by going to www.glas.johnsoncontrols.com/compatibilitychecker. Heating ooling Heat Pump Fan Auxiliary One or two stages One or two stages One or two stages with one or two stages auxiliary heat Single-speed fan Humidifier, dehumidifier, or ventilator (including HRV or ERV) LAS smart thermostat installation instructions - 2018 Johnson ontrols 3

Terminal descriptions Note: If you have only one R wire, connect to R. Note: If you are removing an existing thermostat, remove any jumper wires between R and RH or R and RH. You will not need these for LAS. Y2 W2 First stage of cooling or first stage heat pump Second stage of cooling or second stage heat pump First stage of conventional heating or first stage auxiliary heat for heat pump systems Second stage of conventional heating or second stage of auxiliary heat for heat pump systems Fan 4 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Terminal descriptions O/B Rc Rh Heat pump reversing valve (supports both O type and B type) Auxiliary - humidifier, dehumidifier, or ventilator 24 VA ool 24 VA Heat 24 VA ommon LAS smart thermostat installation instructions - 2018 Johnson ontrols 5

IMPORTANT: If your thermostat is built into the wall and connected to thick wires with wire nuts, or if it is labeled 110, 120, or 240 volts, you have a high voltage system that is not compatible with the LAS Thermostat. Do not connect your thermostat to these high voltage wires. LAS is only compatible with 24 VA systems. 6 LAS smart thermostat installation instructions - 2018 Johnson ontrols

To begin installation, turn off system power 1. Turn off all power to your heating or cooling system at the HVA unit s electrical switch or the breaker box for the building to avoid electrocution or shock. Note: If you are not replacing an existing thermostat, skip to Step 6. 2. If you want to check your system power, adjust the temperature on your current thermostat and wait a few minutes to ensure that your heating or cooling does not power on. WARNIN: Risk of Electric Shock. Turn off the power supply before making electrical connections. ontact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. If you have any doubts about properly installing the device, please contact a professional installer. LAS smart thermostat installation instructions - 2018 Johnson ontrols 7

heck old wiring 3. If you are replacing an existing thermostat, remove the front plate of your old thermostat and take a picture of the current wire colors and connections. This picture will come in handy when connecting your new thermostat. 8 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Removing your old thermostat 4. Before removing the wires from your thermostat terminals, use the included wiring stickers to label your wires. 5. Disconnect your old thermostat and remove the backplate. Note: While disconnecting your old thermostat, use drywall-safe tape to secure the wires and keep them from falling back into the wall. LAS smart thermostat installation instructions - 2018 Johnson ontrols 9

Installing your LAS 6. Remove the front plate by pulling the center of the silver cover toward you from the bottom. Note: Do not pull on the black sensor bar while removing the front plate as this could damage the device. 7. Use a level and the included wall plate to mark the wall where you plan to hang the thermostat. Then drill the holes using the 1/4 drill bit and push in the drywall anchors. 10 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Installing your LAS 8. Remove the liner over the air seal adhesive and align the seal with the drill holes on the back side of the LAS device. Lightly press to secure. Note: If you are using the optional back plate, secure between the wall and the LAS before screwing in the device. 9. Pull all of the wires through both the air seal and terminal opening in the LAS smart thermostat. Press firmly on the wires to push them through the air seal. LAS smart thermostat installation instructions - 2018 Johnson ontrols 11

Attaching your LAS 10. Loosely attach your LAS to the anchors installed in the wall using the included screws. 11. Use a level to straighten the thermostat and tighten the screws until snug. Do not overtighten. 12 LAS smart thermostat installation instructions - 2018 Johnson ontrols

onnect optional -wire adapter Note: If you have a -wire at your thermostat, skip to Step 16. If you do not have a -wire to power your thermostat, use the included -wire adapter to provide power. 12. Remove the cover of your furnace or air handling unit to access the control board and take a picture of the current wiring for reference. 13. In your HVA equipment, disconnect the Y, W, R, or thermostat wires that are currently connected to the control board. Do not disconnect any of the other wires. LAS smart thermostat installation instructions - 2018 Johnson ontrols 13

onnect the -wire adapter 14. Remove the adapter cover and connect the now disconnected Y, W, R, or wires to the corresponding terminal on the -wire adapter. 15. onnect the five labeled wires on the adapter to the corresponding terminals on the control board. Y (1) W(2) R (3) (4) Note: See pages 20-22 for wiring configurations. Note: onnections for the, Y, and R wires are required to support the adapter. 14 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Wiring your LAS 16. Use the picture you took of your old wiring and the wiring stickers as a reference and connect the wires to the corresponding terminals on your new LAS. See pages 23-43 for wiring examples. Note: Depending on the features of your furnace or air handler, you may not have a connection for every terminal. LAS smart thermostat installation instructions - 2018 Johnson ontrols 15

Attach the front plate 17. Before replacing the cover, remove the red tab to the right of the wiring terminals by pulling straight out. This will enable the backup battery in your device. 18. Make sure any excess wire is flush against the device and press the front plate until you hear a click. 16 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Powering on your heating and cooling system 19. Return to your heating and cooling system switch or breaker box to turn the power back on. 20. Once power has been switched on, wait for the welcome screen with the LAS logo and select Tap to continue. After continuing, you will be prompted to accept the End User License Agreement and then the Privacy Notice and Terms of Service to access Internet-enabled features. 21. You will be prompted to confirm your wiring. If any wires were incorrectly detected, tap to correct them. 22. Follow the instructions on the device screen to complete the setup for your heating and cooling system. LAS smart thermostat installation instructions - 2018 Johnson ontrols 17

WIRIN DIARAMS NOTE: Wire colors are for reference only. Not every installation will have wires of the same color. If you are unsure of how to properly install the unit, please contact a licensed electrician or a professional HVA installer before attempting the installation. 18 LAS smart thermostat installation instructions - 2018 Johnson ontrols

LAS smart thermostat installation instructions - 2018 Johnson ontrols 19

Heating and ooling without -wire (Optional ) LAS Air Handler ontrol Board R W2 Y2 -wire adapter Y W O R RH O Y W R WIRES IN WALL TO LAS DEVIE R To LAS Y (1) W(2) R (3) (4) *Any additional wires should bypass the -wire adapter 20 LAS smart thermostat installation instructions - 2018 Johnson ontrols

ooling Only without a -wire (Optional ) LAS Air Handler ontrol Board R W2 Y2 -wire adapter Y W O R RH O Y W R WIRES IN WALL TO LAS DEVIE R To LAS Y (1) W(2) R (3) (4) *Any additional wires should bypass the -wire adapter LAS smart thermostat installation instructions - 2018 Johnson ontrols 21

Heat Pump with Auxiliary Heat without -wire (Optional ) LAS Air Handler ontrol Board R W2 Y2 -wire adapter Y W O R RH O Y W R WIRES IN WALL TO LAS DEVIE R To LAS Y (1) W(2) R (3) (4) 22 *Any additional wires should bypass the -wire adapter O LAS smart thermostat installation instructions - 2018 Johnson ontrols

Traditional A and Heat HVA System ontrol Board R Heat Stage 1 Fan ool Stage 1 Furnace Powered Device R Run Furnace R Outdoor A Unit R W2 RH Y2 O LAS smart thermostat installation instructions - 2018 Johnson ontrols 23

Heat Pump HVA System ontrol Board R Fan ompressor Stage 1 Reversing Valve Furnace Powered Device R Run Furnace R O Heat Pump R W2 RH Y2 O 24 LAS smart thermostat installation instructions - 2018 Johnson ontrols

One Stage Heat Pump with One Stage Auxiliary Heat HVA System ontrol Board R Aux Heat Stage 1 Fan ompressor ommand Stage 1 Reversing Valve Furnace Furnace Powered Device R Run R O Heat Pump R W2 RH Y2 O LAS smart thermostat installation instructions - 2018 Johnson ontrols 25

Traditional Heat HVA System ontrol Board R Heat Stage 1 Furnace Furnace Powered Device R Run R R NOTE: When there is only one transformer, the R terminal is used. NOTE: Forced air heating systems often have a wire to run the fan independently, but not all systems use a wire. W2 Y2 RH O 26 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Traditional A HVA System ontrol Board R Fan ool Stage 1 Air Handler Furnace Powered Device R Run R Outdoor A Unit R W2 RH Y2 O LAS smart thermostat installation instructions - 2018 Johnson ontrols 27

Self-Powered Auxiliary Device HVA System ontrol Board R Switch R Device Relay 24 VA Device R oil R W2 RH Y2 O 28 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Furnace-Powered Auxiliary Device An integrated auxiliary system is built into a furnace or air handler that shares the same power supply as the rest of the system and only requires a single control wire. LAS smart thermostat installation instructions - 2018 Johnson ontrols 29

Furnace-Powered Auxiliary Device HVA System ontrol Board R Heat Stage 1 Fan ool Stage 1 Device Furnace Powered Device R Run R Furnace R W2 RH Y2 O 30 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Two Wire Auxiliary Device without Terminal An auxiliary device that has two terminals with the same label (HUM, DEHUM, or ) and no terminal requires a relay pack for operation. Note: For information on how to obtain a relay pack, contact the nearest Johnson ontrols representative. 1. onnect the relay pack coil between the auxiliary device and terminal on your LAS device. 2. onnect the switch side of the relay pack to the two terminals on the device. LAS smart thermostat installation instructions - 2018 Johnson ontrols 31

Two Wire Auxiliary Device without Terminal Device HUM 1 HUM 2 HVA System ontrol Board R Switch Humidifier 24 VA Relay R oil R W2 Y2 RH O 32 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Two Wire Auxiliary Device with Terminal An auxiliary device with one terminal that does not require a relay pack for operation. 1. onnect the terminal of the device to the terminal on the furnace or air handler. 2. onnect the terminal of your LAS device to the control terminal on the auxiliary device. LAS smart thermostat installation instructions - 2018 Johnson ontrols 33

Two Wire Auxiliary Device with Terminal HVA System ontrol Board R Device 2-Wire Device R R W2 RH Y2 O 34 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Dual-Stage Heat HVA System ontrol Board R Heat Stage 1 Heat Stage 2 R W2 Furnace Powered Device R Run Furnace R W2 RH Y2 O LAS smart thermostat installation instructions - 2018 Johnson ontrols 35

Dual-Stage A HVA System ontrol Board R Fan ool Stage 1 ool Stage 2 Furnace Powered Device R Run Air Handler R Y2 A Unit R W2 RH Y2 O 36 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Dual-Stage Heat and Traditional A HVA System ontrol Board R Heat Heat Stage 1 Stage 2 Fan ool Stage 1 Furnace Powered Device R Run Furnace R W2 A Unit R W2 RH Y2 O LAS smart thermostat installation instructions - 2018 Johnson ontrols 37

Dual-Stage Heat and Dual-Stage A HVA System ontrol Board Heat Heat ool R Stage 1 Stage 2 Fan Stage 1 ool Stage 2 Furnace Powered Device R Run Furnace R W2 Y2 A Unit R W2 RH Y2 O 38 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Dual-Stage Heat Pump HVA System ontrol Board R ompressor ommands Heat/ool Reversing Stage 1 Stage 2 Valve Furnace Furnace Powered Device R Run R Y2 O Heat Pump R W2 RH Y2 O LAS smart thermostat installation instructions - 2018 Johnson ontrols 39

Dual-Stage Heat Pump with Auxiliary Heat HVA System ontrol Board Aux Heat ommands ompressor ommands Heat Heat/ool Reversing R Stage 1 Fan Stage 1 Stage 2 Valve Furnace R Y2 O Furnace Powered Device R Run R Heat Pump W2 RH Y2 O 40 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Heat Pump with Dual-Stage Auxiliary Heat HVA System ontrol Board Aux Heating ommands ompressor ommands R Heat Stage 1 Heat Stage 2 Fan ool Stage 1 Reversing Valve R W2 O Heat Pump R W2 RH Y2 O LAS smart thermostat installation instructions - 2018 Johnson ontrols 41

Traditional Heat/A with Dual Transformers Boiler/Heat ontrol Board Air Handler/ooling ontrol Board R R R Air Handler Furnace Powered Device R Run W2 Y2 42 Boiler RH O Outdoor A Unit LAS smart thermostat installation instructions - 2018 Johnson ontrols

Regulatory information to user F Part 15/Industry anada Radio Equipment Standards 1. This device complies with part 15 of the F Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. This device complies with Industry anada s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. et appareil est conforme aux flux RSS exemptés de licence d Industrie an-ada. L opération est soumise aux deux conditions suivantes: (1) et appareil ne doit pas provoquer d interférence; et (2) et appareil doit accepter toute interférence, y compris les interférences pouvant entraîner un fonctionnement indésirable de l appareil. AN IES-3 (B)/NMB-3(B) RF Safety Statement This device complies with the RF safety requirements for anada and the USA as per RSS-102 and F Part 1.1310, RF Exposure radiation limits for the eneral Population / Uncontrolled Exposure. This device shall be installed to maintain a separation distance of at least 20 cm (8 in) from the general population. hanges or modifications not expressly approved by Johnson ontrols will void your authority to operate this device. Warranty can be found at www.glas.johnsoncontrols.com/legal/warranty. LAS smart thermostat installation instructions - 2018 Johnson ontrols 43

44 LAS smart thermostat installation instructions - 2018 Johnson ontrols

Part No. 24-11158-00016, Rev. D