JM Aerofoil Fans Bulletin JMA60-05

Similar documents
Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

Belt Driven Mixed Flow Fans

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

A. Codes and Standards that are Standard at the University:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION (15833) - HVAC POWER VENTILATORS

University of Houston Master Construction Specifications Insert Project Name

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Axial flow fan AXICO ANTI-STALL

POWERPLUS SPP Product Brochure

Industrial Fans & Blowers

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Selecting the Correct Fan

A Fläkt Woods Company 2933 Symmes Road, Fairfield, Ohio Phone: (513) Fax: (513)

Tunnel Axial Flow Fan

TUNNEL FANS STANDARD AND HOT SMOKE

Centrifugal Fans, Non-Overloading, Backward Inclined

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

PFS Single stage axial fan The axial fan for modern boiler plants

MARLOW PUMPS RECIRCULATION

SECTION AXIAL FANS

SECTION XXXXX POSITIVE DISPLACEMENT BLOWER WITH SOUNDSEAL COMPACT ENCLOSURE

Emergency Extract Ventilation

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

Full-line Product Overview

ACN SMOKE INSTALLATION AND MAINTENANCE

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Twin City Fan & Blower

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Introduction to Fans. The Basics of Fan Principles and Terminology

Axial Flow Fans Good Design Guide

AC Backward Curved Motorized Impellers

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

AXIAL & JET FANS FOR TUNNEL VENTILATION

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

LC Series - Light Commercial Pump Station Installation and Operation Manual

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Plenum Fans. Model HPA. Direct Drive

Fans: Features and Analysis

SECTION STEAM CONDENSATE PUMPS

Direct Fired Heater Model AD Specification

Wilo IL Vertical Split-Coupled Inline Pumps

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

CPF PRODUCT DESCRIPTION

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

CR A-F-A-E-HQQE 3x400/ HZ

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

1/2 1-1/4 H.P. DISPOSER MODELS

English CNA-CNB. Centrifugal fans Installation and maintenance

FAN IMPELLERS & FAN CASINGS

380 Series Multi-Stage Centrifugal Pumps

INSTALLATION, OPERATION & MAINTENANCE MANUAL

CPC PRODUCT DESCRIPTION

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

HOMA Pump, Ansonia Connecticut

AXPR Wall Mounted Axial Panel Fans

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Caution: The fans must not be used in bath or shower enclosures.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

A. This Section includes air-handling units with coils for indoor installations.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Smoke extract fan SMHA HATCH

Transformer oil coolers BETA & CETA

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS


Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Modular Supply Make-Up Air Unit

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

SECTION AIR HANDLING UNIT

CR A-F-A-V-HQQV 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

SECTION COOLING TOWERS

Transcription:

www.howden.com JM Aerofoil Fans Bulletin JMA60-05

Introduction The high performance JM Aerofoil Fan Benefits of the JM Aerofoil Fan include compactness, low cost, high efficiency and rugged design. Availability in numerous fan diameters, hub diameters, speeds and blade solidities assures a highly efficient selection for your application. Installations Woods fan can be found in thousands of offices, educational, medical, manufacturing and public buildings from the Mall of America in Minneapolis and the new Boston Garden to the San Francisco Airport and McCormick Place Convention Center in Chicago. Service Servicing Woods installations is a cooperative effort between the Woods engineering and field service staff. Field service groups are based in both Fairfield, Ohio (USA) and Colchester, England (UK). Sales Office There are over 100 sales offices in over 50 major cities throughout North America. Sound Levels Extensive sound testing has proved that the JM Aerofoil axial fans have the lowest sound power levels currently available. Both inlet and outlet sound power levels are given for every fan size and speed at the design performance. Woods in North America Woods fans have been sold in North America since 1957. The company s US marketing and manufacturing group is located at the Howden American Fan Company, Fairfield, Ohio. Ratings Howden American Fan Company certifies that the model JM Aerofoil fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance ratings only. Quality Assurance Howden American Fan Company s Quality Management System is certified to ISO-9001: 2000 standards. JM Aerofoil Fans Page 2 of 7

JM Aerofoil Features Motors Motors are cast iron, pad mounted design suitable for horizontal through vertical operation. Motors are 3 phase premium efficiency totally enclosed air over design with 1.15 service factor. Standard efficiency motors are also available. All efficiency testing and labelling is done in accordance with NEMA MG1-12.53 standard. Class F insulation with Class B rise is standard. Bearings are anti-friction grease lubricated ball or roller with 30,000 hour L-10 life minimum. Electrical Supply and Starting Standard motors are 3 phase/60 Hz/460V.Other voltages, 50 Hz, and 1 phase are also available. Motors are available for across-the line, Wye-Delta, Part Winding, or Autotransformer starting. Impellers JM Aerofoil impellers have a unique aerodynamic blade section to optimise efficiency and performance while minimizing the noise. The think sections obtained by high pressure die cast technique promote efficiency, strength and lower weight. Impellers are comprised of high pressure die cast aluminium blades, hub and clamp plate with fully adjustable pitch angle. All impeller components are X-ray examined to ASTM E-155 prior to machining to assure premium quality. Impellers are precision balanced as a component and fan assembly is further balanced to minimise vibration levels. Casings JM fan casings are heavy gauge steel with spun flanges and continuously welded seams. They are manufactured to stringent tolerances for roundness assuring proper blade tip clearances required for optimal performance. Non-Overloading JM Aerofoil fans have a non-overloading characteristic. The peak power input occurs within normal operating range of pressures and is always exceeded by the motor rating. Reversal of Airflow JM Aerofoil fans can be reversed for emergency use. Reversal is obtained by interchanging electrical connections. If frequent reversals are necessary, contact the factory. A truly reversible impeller can be provided where equal volume in either airflow direction is required. Accessories Motor and Impeller side guards Mounting Feet Horizontal or vertical suspension clips Companion Flanges Flexible Connectors Back draft Dampers Inlet Bells Vibration Isolators Outlet Cones, Silencers and Acoustical Diffusers Finish Parts are cleaned, primed and then finish painted with premium grade enamel. Hot dipped galvanized, epoxy and other coatings are also available. JM Aerofoil Fans Page 3 of 7

Forms of running and mounting The direction of airflow through the fan and the fan mounting position are defined as the Form of running. On each chart is shown the standard Form(s) of running for that particular fan, when mounted horizontally. For vertical operation add suffix U for airflow up, or suffix D for airflow down. Arrows indicating correct rotation and direction of airflow are incorporated in the duct nameplate. The standard Form of running offered will be Form B. When an alternative is available: see chart information, please request when the fan is ordered. Form of running is especially relevant when weatherproofed motors are required. Mounting Horizontal JM Aerofoil fans may be floor or ceiling mounted with optional mounting feet. They may also be ceiling suspended with optional horizontal suspension clips. Vertical JM Aerofoil fans may be mounted for vertical up or down airflow. Optional vertical mounting clips are available. Angular JM Aerofoil fans may be angular mounted at any position. For special mounting clip arrangement contact factory. JM Aerofoil Fans Page 4 of 7

Fan Specifications 1. Fans shall be manufactured by Howden American Fan/Woods USA. Fan casings shall be made of heavy gauge steel with spun flanges and continuously welded seams. They shall be manufactured to stringent tolerances for roundness to assure proper blade tip clearance for optimal performance. 2. Motors shall be cast iron frame, pad-mounted design suitable for horizontal through vertical operation. Motors shall be 3 phase premium efficiency (or 1 phase standard efficiency) totally enclosed air over design with 1.15 service factor. All motor efficiency testing and labelling shall be done in accordance with NEMA MG1-12.53 standard. Insulation shall be class F with class B rise. Bearings shall be grease lubricated antifriction ball or roller type with 30,000 hours L-10 life minimum. 3. Impeller shall consist of high pressure die cast aluminium airfoil blades, hub, and clamp plate with fully adjustable blade pitch angle. All impeller components are to be X-ray examined to ASTM E-155 prior to machining to assure casting integrity and quality. Impellers shall be precision balanced as a component and then further balanced as a fan assembly to minimise vibration levels and assure smooth operation. 4. Motor supports shall be heavy gauge steel and bolted to the fan casing and the motor to assure the concentricity of the motor to the fan casing. 5. Finish of fan assembly shall consist of highpressure cleaning, application of 1 coat of primer and 1 coat of enamel paint. Dry film thickness (DFT) shall be 2.5 mils minimum. 6. Fans shall be licensed to bear the AMCA Seal. Ratings shall be based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. 7. Fan manufacturer shall be certified to ISO 9001 quality system standards. Also Available... JM Aerofoil Fans for Building Fire Safety/Smoke Exhaust In any building, fire smoke can be the major killer. In the event of a fire in densely populated buildings, such as schools, office buildings, department stores, shopping malls, sports arenas, and hotels, rapid, efficient smoke evacuation is vital to safe escape and minimisation of damage. Howden American Fan/Woods USA has built and thoroughly tested JM Aerofoil fans specifically for this application. Fans are typically rated for 250 degrees C (482 degrees F) for one hour or 200 degrees C (392 degrees F) for two hours. Higher temperature ratings are available. Fans for smoke exhaust can be provided for either duct mounting or as roof mounted exhaust fan. Contact your local Howden American Fan USA sales representative or the factory for more information. JM Aerofoil Fans Page 5 of 7

Installation Recommendations JM Aerofoil Fans Page 6 of 7

www.howden.com At the heart of your operations Howden people live to improve our products and services and for over 160 years our world has revolved around our customers.this dedication means our air and gas handling equipment adds maximum value to your operations. We have innovation in our hearts and every day we focus on providing you with the best solutions for your vital operations. Howden American Fan Company 2933 Symmes Rd Fairfield OH 45014-2099 Tel: 1-866-771-6266 Fax: 1-513-870-6249 Email: haf.sales@howden.com Howden Group Limited. All rights reserved. 2016 Howden and the flying H logo are registered trademarks belonging to Howden Group Limited