QuadraFlow Cooling Tower

Similar documents
ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

Aquatower STEEL COOLING TOWER. engineering data and specifications

/ Aquatower Fiberglass Cooling Tower /

Lenntech. Tel Fax

MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

QuadraFlow cooling tower. engineering data and specifications

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

ENGINEERING DATA AND SPECIFICATIONS. MH Fluid Cooler

MH fluid cooler. engineering data and specifications

Downtime Instructions

cooling tower downtime instructions

SECTION COOLING TOWERS

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

SECTION COOLING TOWERS

ENGINEERING AND SPECIFICATIONS. Marley MC FLUID COOLER

NC stainless steel COOLING TOWER. specifications

Lenntech. Tel Fax Engineering Data & Specifications

steel COOLING TOWER specifications

What is a Closed circuit Cooling Tower (CCT)?

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Marley Ultra Quiet Fan

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

MD cooling tower. engineering data and specifications

Efficient, Long Lasting Evaporative Condensers

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

Mr. GoodTower Service Center

Lenntech. / Marley MD Cooling Tower / Tel Fax Engineering Data & Specifications

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Cold Weather Operation Of Cooling Towers

/ MH Fluid Cooler / User Manual F

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

Series 1500 Cooling Tower Specification

Products and Services

MH Fluid Cooler USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

AV6800 STEEL COOLING TOWER. engineering data and specifications

JCseries EVAPORATIVE CONDENSER. engineering data

Direct Fired Heater Model AD Specification

SERIES 4HOO AQUATUWER Steel Crossflo~m Cooling Tower

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Industrial Fans & Blowers

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

Fan Motor. user manual INSTALLATION - OPERATION - MAINTENANCE

Belt Driven Mixed Flow Fans

/ Marley Collection Basin Heater / User Manual

Evaporative Condensers

Aquatower cooling tower

SPRING cooling tower parts reference guide OEM PARTS FOR MARLEY COOLING TOWERS AND FLUID COOLERS

/ Marley MH Fluid Cooler / User Manual sea_05-116d

A. Codes and Standards that are Standard at the University:

Marley Collection Basin Heater Circuit

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Unilite cooling tower

Privately held company

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Aquatower cooling tower

Modular Supply Make-Up Air Unit

Multistage Centrifugal Blowers

and SHUTTERS Made to Work. Built to Last.

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

CONTENTS. B. System Design and Performance Requirements

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

How about Savings in Time, Money, Energy and Longer Life?

Cube DT evaporative condenser

Direct Gas-Fired Make-Up Air

COOLING TECHNOLOGY INSTITUTE

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

NC steel cooling tower

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

VOLUME 2 (BOQ & Price Bid)

Un-Used Series CXV Evaporative Condenser

AT, MT & ES Series Super Low Sound Fan

/ Recold J Series / Designed To Perform. Built To Last.

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

Closed Circuit Cooling Towers

Temptek Auxiliary Equipment

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Product Introduction...D9. Benefits...D11. Construction Details...D13. Custom Features & Options...D15. Accessories...D18. Engineering Data...

SECTION (15833) - HVAC POWER VENTILATORS

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data...

Indirect Gas-Fired Make-Up Air

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

ICT Cooling Towers. Stainless Steel Basins and Fiberglass Casings Available. Advanced Features In Induced Draft, Counterflow Towers.

Plenum Fans. Model HPA. Direct Drive

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

SECTION AIR COOLED WATER CHILLERS

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SECTION AIR COMPRESSORS AND ACCESSORIES

Transcription:

QuadraFlow Cooling Tower

/ A Truly Unique Cooling Tower Design / The QuadraFlow is a unique cooling tower. Unique in its design unique in its appearance unique in its performance reliability in all seasons unique in its maintainability and unique in its use of inert, noncorroding construction materials. The FRP structure and basins PVC fill, louvers and eliminators and the stainless steel hardware and mechanical equipment support structure all combine to create a cooling tower capable of forgiving the kind of operation and treatment that would destroy lesser towers.

Long Life Construction The QuadraFlow is manufactured and assembled from corrosion-proof materials whose reliability is unquestioned even in very severe operating environments. Low Operating Costs Marley high-efficiency fill and fans, gravity-flow water distribution, and efficient Geareducer drive work together to offer maximum cooling with minimum power use. CTI Certified Although the QuadraFlow s thermal ratings are certified by CTI, SPX Cooling Technologies will not use certification as a means to avoid responsibility. The QuadraFlow is guaranteed to work as well in the real world as it does in the laboratory. SPX guarantees the thermal performance of each QuadraFlow as installed. 5-Year Warranty The QuadraFlow cooling tower is warranted for five full years! This includes fill, mechanical equipment, and structure. All Season Performance The QuadraFlow performs as specified in the heat of summer responds well to energy-management techniques in the spring and fall operates virtually ice-free in the dead of winter and offers simple maintenance all year long. Low Maintenance Induced-draft adjustable-pitch fan Marley System 5 Geareducer stainless steel free floating driveshaft TEFC, 1.15 service factor, horizontal-shaft motor and inert construction materials. Geareducer oil changes are not required for five full years the lowest maintenance requirements in the industry.

/ Features and Benefits /

Air Movement Package Removable fan guard welded heavy gauge rods. Hot dip galvanized after fabrication. Eased inlet fan cylinder assures full area, low turbulent airflow through the cylinder. Marley fan cast aluminum alloy or glass reinforced epoxy. Adjustable pitch blades. Marley System 5 Geareducer no oil changes for five full years. Offers significant savings in maintenance costs. External Geareducer Oil level Gauge and Fill-Drain connection user friendly maintenance. Marley Full-Floating Driveshaft stainless steel tube and non-lubricated neoprene flexible elements assure long, maintenance-free service. TEFC Fan Motor 1.15 service factor, variable torque, and specially insulated for cooling tower duty. Water Distribution System Gravity flow distribution system easy, nonrestrictive maintenance. Basin covers are standard. Marley Spiral Target polypropylene nozzles. Marley MX thermoformed PVC film fill suspended from structural stainless steel tubing. Integral eliminators and louvers keep circulating water confined to fill, even at low air rates. Structure Crossflow configuration easier and safer to maintain. FRP and series 300 stainless steel corrosion proof construction. Four air inlet faces minimizes recirculation. Supporting steel simplifies foundation requirements

/ On-Site Assembly / The QuadraFlow is factory-fabricated, and is designed to be assembled at the jobsite. This allows the design flexibility that results from the unique QuadraFlow configuration and permits a wide variety of orientations. Normally this assembly is included as part of the cooling tower contract, and is performed by erection subcontractors recognized and sanctioned by SPX. Their knowledge and expertise assures proper fit-up, alignment, and sealing of the various tower components and contributes significantly to the trouble-free long-term operation of the tower. It also enables SPX to guarantee the thermal performance of the assembled tower. Therefore, it is strongly recommended that either SPX supervision or complete tower erection be included as part of your order. Nevertheless, we recognize that circumstances may produce situations that require the tower to be assembled by inexperienced personnel without benefit of SPX erection labor or supervision. In support of that, a comprehensive, illustrated, assembly instruction manual is included with every shipment. This manual pictorially identifies the various tower components and provides step-by-step instructions designed to result in a properly assembled installation. Copies of this manual are also available to customers, on request, prior to the shipment of the tower to permit planning of the assembly process. However, we regret that thermal performance of a QuadraFlow cannot be certified or guaranteed without qualified SPX supervision during the assembly process.

TOWER MODELS TONS W H W 21120 129-183 12'-8" 7'-2" 21220 186-211 12'-8" 8'-5" 21320 204-256 12'-8" 9'-9" 22120 243-304 14'-1" 8'-6" W 22220 312-425 14'-1" 9'-11" 23120 390-475 16'-8" 9'-11" 23220 419-546 16'-8" 11'-3" 24120* 531-836 24'-6" 12'-9" 24220* 796-1047 24'-6" 16'-1" H *Models in this box size require a taller fan cylinder / Available Options / Inlet Water Bypass provision for total water bypass directly into the tower collection basin during cold weather operation. Hoistable Steel Grillage allows assembling tower at grade on temporary supports and hoisting into final location. Fire Retardant FRP flame spread rating of 25 or less per ASTM E-84. Control Systems ranging in sophistication from standard fan starters and disconnects to Programmable Logic Controllers that work in conjunction with your building or process system. Variable Speed Drive the ultimate in temperature control, energy management, and mechanical equipment longevity Electric Basin Heater Package maintains collection basin water temperatures between 40 F and 45 F during tower shutdown. Vibration Limit Switch shuts down the fan motor if excessive vibration occurs. Solid State Water Level Control Package monitor basin water level with solenoid-valve water makeup. Configurations include makeup along with high and low water level alarm and cutoff and electric basin heater cutoff. Magnetrol Electric Float Switch monitor basin water level with solenoid-valve water makeup.

The Quadraflow Engineering Data and Specifications Manual QF-TS provides engineering schematics, data, and information necessary for initial tower layout and details the tower in the form of specification language, providing technical as well as common-sense information on the importance of your specifications. Available on the web at spxcooling.com or see your Marley sales representative for a copy. The Marley UPDATE web-based application software provides model selections perfectly tuned to your cooling water system. Functions include model selection, specifications, model optimization, performance curves, engineering data, and free cooling applications. Available to both registered customers and guests at spxcooling.com. If we can help in any way, feel free to call. To find the Marley representative nearest you call 1 800 462 7539 or check the web at spxcooling.com. SPX COOLING TECHNOLOGIES, INC 7401 WEST 129 STREET OVERLAND PARK, KANSAS 66213 UNITED STATES 913 664 7400 spxcooling@spx.com spxcooling.com In the interest of technological progress, all products are subject to design and/or material change without notice. 2011 SPX Printed in USA QF-07A