GUIDELINIE ECB S R10. March European Certification Body GmbH

Similar documents
Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000

Electromagnetic Locking Devices Performance Requirements

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

This document is a preview generated by EVS

Mechanically operated locks and locking plates

Guide to interpreting Markings for Single Axis Fire Doors Hinges

Electromagnetic Locking Devices

DRAFT EUROPEAN STANDARD pren NORME EUROPÉENNE EUROPÄISCHE NORM April English version

Contents EN :2006+A2:2016 (E)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BURGLAR, BALLISTIC, BLAST & FIRE RESISTANT SYSTEMS

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Controlled Door Closing Devices

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Panic and Emergency Exit Devices

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

This document is a preview generated by EVS

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Panic & Emergency Exit Hardware

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

PHA Panic Hardware for timber doors

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

Rim Locks. Rim Locks Index. Standards & Approvals. Keying Groups. Keys

Hardware for Sliding Doors & Folding Doors

Loss Prevention Standard

PANIC EXIT HARDWARE DX-500 Serie

presented by est. 1940

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Spark Extinguishing Systems

Best practice guide. Hardware for sliding doors and folding doors to BS EN in association with. Association of Building Hardware Manufacturers

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Newstar Locks. NEWSTAR form and function for life. BS Range. London Fire Brigade Range

SOUTH AFRICAN NATIONAL STANDARD

SMARTair SOLUTIONS GUIDE. Providing complete specifications utilising ABLOY SMARTair. Page 1

Procedure for the Approval of New Fire Detection and Alarm Technologies

Operating Instructions!

Panic Exit Devices. ASSA ABLOY, the global leader in door opening solutions

An ASSA ABLOY Group brand. ABLOY Safety and Security Systems for Petroleum

Annex of the certificate (Page 1/7) Accreditation Scope

Electromagnetic compatibility (EMC)

ABLOY camlocks. Expertise at your service

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions

High Security Locking. Product Catalogue

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

INTERNATIONAL STANDARD

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

For more information on Abloy UK visit EXIT HARDWARE

Motor Lock Manual 840C-50, 841C-50, 841C-35, 851C-35, 851C-50, 850C-50. ASSA ABLOY, the global leader in door opening solutions.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Contents CONTENTS FOREWORD REGISTRATION REGISTRATION PERIOD DISCONTINUATION OF PERFORMANCE SPECIFICATIONS...

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Product overview. The security program of Wittkopp: Electronic locks Key locks Safe deposit locks Boltworks Accessories

ELECTRIC LOCKS. Europrofile range

Instruction Manual. Electronic gas and smoke detector GRM

ABLOY CAMLOCKS. Expertise at your service

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

Rules for Classification and Construction Additional Rules and Guidelines

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

High Security Locking Solutions for the Water Utilities Industry

ABLOY camlocks. Expertise at your service

Designed to provide immediate escape, first time, every time

ADDITIONAL REQUIREMENTS

EC-Certificate of Conformity Certificate CPD

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

FG-400:2. Product registration Anti-intruder products applicable to burglary and thefts insurance. Gyldig fra

Installation instructions

G4S ACADEMY STANDARDS COMPARISON KEY

An ASSA ABLOY Group brand. ABLOY safety and security systems for MINING INDUSTRY

MANUAL Oil Level Sensor

Fapim spa. Dutch Buildings Decree SKG ENG. Building hardware

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)

Specifying Security Hardware for Doors

WIRELESS WATER CONTROLLER. MC-503RC Installation and Operation Manual

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

ABLOY PADLOCKS UNSURPASSED PERFORMANCE

Specification for Portable Traffic Signal Control Equipment for use at Roadworks

Consumer Products Services Germany GmbH Türkheim Germany

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

NFPA 80 Overview January 21, 2016

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

INFORMATIONAL PUBLICATION SECURITY VS. EXITING... Door Locking Hardware in Schools

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

GMA Panels with double busbar

F O C U S D O O R C L O S E R S

Ironmongery Performance Specifications

ABLOY Government Locking Solutions

ELSTA MOSDORFER- Energy Distribution with Competence

Transcription:

March 2017 GUIDELINIE ECB S R10 Additional requirements for burglar resistant products within the scope of EN 1627 according to guideline ECB S C10 with electromechanical locks, striking plates or security plates as well as mechatronic cylinders 1. Scope and objective The Guideline defines the requirements of European Certification Body (ECB) GmbH for attacks on electromechanical locks, striking plates, security plates and mechatronic cylinders that are not covered by EN 1627. Only testing in electrical powerless condition is intended (see Chapter 1 Scope ). Contents based on the respective requirements of ÖNORM B 5338 and ÖNORM B 5351. 2. Definitions 2.1 Electromechanical lock: Device using electrically operated means to effect or enable locking and/or unlocking. 2.2 Electromechanical strike (or electrical door opener): Building component which is fixed to the frame and uses electrically operated means to effect or enable locking and/or unlocking. 2.3 Mechatronic cylinder (MC): Device with an integrated or a remote electronic system, which is to be used with a lock for the purpose of operating the lock and/or detaining elements after verifying the authorisation of an electronic key, and which can be replaced by a mechanical cylinder conforming to EN 1303 without replacing any door furniture. 3. Normative references EN 1627, Pedestrian doorsets, windows, curtain walling, grilles and shutters Burglar resistance Requirements and classification EN 1303, Building hardware Cylinders for locks Requirements and test methods EN 14846, Building hardware Locks and latches Electromechanically operated locks and striking plates - Requirements and test methods EN 15684, Building hardware Mechatronic cylinders Requirements and test methods EN 61000-4-2, Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test (IEC 61000-4-2) DIN 18250, Schlösser Einsteckschlösser für Feuerschutz- und Rauchschutztüren EN 12209, Building hardware Mechanically operated locks and locking plates Requierements and test methods 4. Requirements Electromechanical locks and striking plates shall conform to EN 14846. Allocation to the respective resistance class (RC) is contained in Table 1 of this Guideline. Mechatronic cylinders shall conform to EN 15684. Allocation to the respective resistance class (RC) is contained in Table 2 of this Guideline. 4.1 Electromechanical locks and electromechanical strikes shall be designed and built according to the de-energised circuit principle (de-energised locking). Power failure shall not cause release of the component from the attack side. In particular, for large objects (with control technology or linked with alarm systems, e.g.) the use of monitored cables is recommended. EN 1906, Building hardware Lever handles and knob furniture Requirements and test methods - page 1 of 5 -

The connecting cables, existing terminal boxes and the releasing unit (electronic component which allows access) shall be installed in the secured area (see Figures 1a and 1b). During the manual test according to EN 1630 (in the respective resistance class), it shall not be possible to bare these components in such a way that manipulation (e.g., removal of the insulation of the cables and fixing of terminals) is possible. A special risk exists for wirings to key switches transferring analogue signals which directly enable release. Wirings which transfer encoded signals do not require mechanical protection. It shall, however, be ensured that the signal sequences cannot be spied out and be used for manipulations. Proof of that shall, e.g., be given in the form of a confirmation and technical explanation of the manufacturer (assessment according to EN 1630). The release of burglar resistant building parts with electromechanical components may only take place after completion of the manual test according to EN 1630, except for the replacement of a mechanical cylinder by a mechatronic cylinder. 4.2 Cylinders For mechatronic cylinders with a projection of more than 3 mm (e.g., of the cylinder plug or the actuating element), a pull test (protection against cylinder/cylinder plug extraction) as well as an anti-twist test (resistance against attacks by twisting off) as well as, if necessary, an anti-drill test (resistance against drilling) shall be carried out. The anti-drill test may be omitted if the drill protection is completely maintained after the pull test and the anti-twist test. If a security plate for mechatronic cylinders is designed and built as a round profile cylinder or round cylinder, any necessary cylinder bridge duct shall be positioned in the security plate at the protected side (not accessible for attacks). Later changes of tested security plates for round profile cylinders or round cylinders are not allowed without supplementary strength and antidrill tests according to EN 1906. 4.3 Electromechanical security plates They shall be tested according to EN 1906 for mechanical security as well as for locking security, protection against manipulation and the mechatronic system similar to EN 15684. 4.4 Connection to the access control system The decision about authorised access shall not be taken in parts of the system which are accessible to the attacker. Direct access to the circuit of the electrical locking from the attack side shall be prevented. The protective effect against electrical manipulation shall satisfy the relevant class according to EN 14846. If a mechatronic cylinder according to EN 15684 is used, the decision about authorised access shall not be taken in parts of the system which are accessible to the attacker unless there is a secure (encrypted) data connection to the locking element. Note: The requirements and the protection level of the access control system shall be matched with the object that shall be protected and its specific protection level. 4.5 Connection of a key switch at the attack side A key switch shall be equipped with a cylinder according to EN 1627 Table 2 or a mechatronic cylinder according to Table 2 of this Guideline. The box of the key switch shall have a secure alarm monitoring system against unauthorised opening (e.g., by means of a photo cell) and drilling (e.g., alarm wiring). The alarm signal blocks unlocking for a period of X (e.g. twice the resistance time, however, at least for 15 minutes) via the control of the component. Such blocking can be stopped from a secured place at any time. Alternatively, the box, its installation as well as the surrounding wall may be tested according to EN 1630 and shall satisfy the requirements of the respective resistance class. The connecting cable, exising terminal boxes and the releasing unit shall be designed and built as required in section 4.1. 4.6 Connection of a wireless remote control at the attack side The respective locking variation may only be derivable from a marking at the authorising medium (e.g. wireless remote control) by the manufacturer. The transfer of data (the radio signal sent) shall be encrypted. The radio signal shall change with any further activation (so-called rolling code ). Opening by use of the spied-out radio signal shall be prevented for a period of at least 15 minutes (in resistance class 6, for at least 20 minutes). The releasing unit shall be positioned in the secured area. - page 2 of 5 -

Table 1 Criteria for electromechanically operated locks and striking plates Classification Resistance class RC 1 RC 2 RC 3 RC 4 RC 5 RC 6 1 Category of use 2 2 2 2 2 2 2 Durability and load on latchbolt L L L L L L 3 Door mass and closing force 4 4 4 5 5 5 4 Suitability for use on fire/smoke doors 0 0 0 0 0 0 5 Safety 0 0 0 0 0 0 6 Corrosion resistance, temperature and humidity G G G G G G 7 Security - drill resistance 3 4 4 5 7 7 8 Security electrical function 0 0 0 1 1 1 9 Security electrical manipulation 2 2 2 3 3 3 meaning (according to EN 14846): Digit: Class: 1 Category of use 2 for use by people with some incentive to exercise care but where there is some chance of misuse, e.g. office doors 2 Durability and load on latchbolt L 100.000 test cycles 25 N load on latchbolt 3 Door mass and closing force 4 Suitability for use on fire/smoke doors 4 up to 100 kg 25 N maximum closing force 5 up to 200 kg 25 N maximum closing force 0 not intended for use on smoke/fire door assemblies 5 Safety 0 no safety requirement 6 Corrosion resistance, temperature and humidity G moderate resistance -10 C to +55 C, humidity level 1 Security: 7 Security - drill resistance 3 medium security without drill protection (EN 12209 shall apply) 4 high security without drill protection 5 high security with drill protection 7 ultra-high security with drill protection 8 Security electrical function 0 no requirement 1 status indication 9 Security electrical 2 - voltage drop protection manipulation - protection against cutting of cables - resistance to electromagnetic manipulation - resistance to electrostatic discharge, EN 61000-4-2 - resistance to electrostatic manipulation, EN 61000-4-2 3 - voltage drop protection - Protection against cutting of cables - Protection against the effects of wire manipulation - Resistance to electromagnetic manipulation - Resistance to electrostatic discharge, EN 61000-4-2 - Resistance to electrostatic manipulation, EN 61000-4-2 - page 3 of 5 -

Table 2 Criteria for mechatronic cylinders (MC) Classification Resistance class RC 1 RC 2 RC 3 RC 4 RC 5 RC 6 1 Category of use 1 1 1 1 1 1 2 Durability 5 5 5 5 5 5 3 Fire/smoke resistance 0 0 0 0 0 0 4 Environmental resistance 2 2 2 2 2 2 5 Mechanical key related security A A A A A A 6 Electronic key related security E E E F F F 7 System management 0 0 0 0 0 0 8 Attack resistance 1 1 1 2 2 2 meaning (according to EN 15684): Digit: Class: 1 Category of use 1 according to the requirements of EN 15684 section 4.2 2 Durability 5 50 000 test cycles 3 Fire/smoke resistance 0 not approved for use on fire/smoke door assemblies 4 Environmental resistance 2 for MC and for MC-key according to EN 15684 section 4.5 5 Mechanical key related security 6 Electronic key related security A no grade in EN 1303:2005 E minimum number of electronic code variations (different keys) = 100,000,000; communication must be protected F minimum number of electronic code variations (different keys) = 1,100,000,000; communication must be protected 7 System management 0 no requirement 8 Attack resistance 1 according to Table 9 of EN 15684 section 4.8 2 according to Table 9 of EN 15684 section 4.8 With mechatronic cylinders according to Table 2, contactless data transmission shall be encrypted. It is recommended using a "hobbing / rolling code". - page 4 of 5 -

Figure 1 Doors with electromechanically operated locks and connection to access control systems Reference: ÖNORM B 5338:2011, page 7 Figure 1a Door with releasing unit in the door leaf (Example) Figure 1b Door with separate releasing unit (Example) Meaning: 1 Electromechanically operated lock 2 Interrogation unit for authorising medium 3 Signal wiring with encrypted signal to the releasing unit 4 Releasing unit 5 Connecting cable, in RC 4 and higher monitored 6 Cable access points for connecting cables 7 Terminal box The component parts 4 to 7 shall be installed in the secured area. It shall not be possible to reach them with tools. - page 5 of 5 -