VPC Gas Cabinet Heater Range

Similar documents
VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

CP+ Gas & Oil Cabinet Heater Range

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater

VPC Gas Cabinet Heater Range

PT Radiant Heater Range

Powrmatic PZN / PZN X Hot Water Heater

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

HEM Heat Exchange Modules

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

TE Air Rotation Space Heater Industrial & Commercial Heating Systems

NVxEA External Gas Unit Heater

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

NVx Suspended Gas Unit Heater

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

VPx. Power Vented Gas Cabinet Heater Nautral Gas & LPG Fired Options

Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems

Installation Instructions

CPx Gas & Oil Cabinet Heater Range

NVx Suspended Gas Unit Heater Range

Flue & Flue Kits for NVx, VPC & NVS

BENSON.... Variante3 Fired Unit Heaters...

Powrmatic Control Systems Industrial & Commercial Heating Systems

Destratification Fans Industrial & Commercial Heating Systems

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Exhaust Duct Design Page 1 of (C)

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

PREEVA air handling unit

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

The NCA-G Range. Installation and Servicing Instructions WARNING: THIS APPLIANCE MUST BE EARTHED

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

CPx Gas or Oil Cabinet Heater Range

CPx Gas & Oil Cabinet Heater Industrial & Commercial Heating Systems

Users, Installation and Servicing Instructions

The NCE-AG and CPE-AG Ranges Range

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

BENSON VARIANTE 2 RANGE

CP Range. Users, Installation & Servicing Instructions Gas & Oil Fired Heaters TESTED

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

... UDSA - UDSBD Gas fired unit heaters...

Gas-fired unit heaters for indoor installation

RHC GAS FIRED HEATING COILS

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

BENSON LINEAR RADIANT TUBE

BENSON VARIANTE 2 RANGE. Headin BI DIRECTIONAL NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

BENSON VARIANTE 2 RANGE

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

CECx Destratification Fan

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

PSO Gas & Oil Cabinet Heater Range

Installation and Operating Manual Drying Cabinet

NVS Condensing Gas Suspended Unit Heater

INSTALLATION & SERVICING MANUAL FOR HARRY TAYLOR VARIANTE² BI DIRECTIONAL NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

RHC & RHCE gas fired heating coils

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Sirius FS. Working towards a cleaner future

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

OUH Suspended Oil Unit Heater

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

RBR Relay Boxes. Installation Manual. Industrial & Commercial Heating Systems. Doc Ref: M406 Issue 1.

RG7D 1-Stage Heat Series

INSTALLATION & SERVICING MANUAL FOR BENSON PV TUBULAR CABINET HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

Powrmatic PQ Electric Quartz Infrared Heaters - A Range

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Aegean Range. A new range of fan coils for heating and cooling commercial applications

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

Flue Fire Prevention Awareness

SUBMITTAL SCHEDULE & DATA

WHHR Midi & Midi Lite

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

SCHOOL OF ENGINEERING. BSc(HONS) IN QUANTITY SURVEYING & COMMERCIAL MANAGEMENT SEMESTER 1 EXAMINATION 2015/2016 RISK AND VALUE MANAGEMENT

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

FMH Range Hoods. Installation, Operation & Maintenance Instructions

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Drying Cabinet Installation and Operating Manual

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

VORTEX BLUE OIL RANGE

Transcription:

VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTIATION // AIR CONDITIONING // OEM PRODUCTS

VPC Overview Models Available VPC UF - Upright Freeblowing Unit VPC UD - Upright Ducted Unit Efficiencies Fuel usage and emissions are a key consideration within the VPC design. All heaters have efficiencies which meet or exceed the requirements of current UK Part2B Building Regulations. Installer Friendly ow level flue discharge option (no roof work) Flue only or room sealed flue systems All units are fan assisted Site interchangeable top or side flue/combustion air spigot positions Plain side panel - provides greater flexibility in location Extended heads Factory fitted & pre wired controls available Peace Of Mind More than sixty years experience in warm air Two year parts and one year labour guarantee Ten year sliding scale time related heat exchanger warranty Cabinet Frame and panel construction, complete with a separate burner compartment accessed via a full width door and finished with hard wearing epoxy powder coat stove baked paint. Heat Exchanger Four pass tubular assembly manufactured from aluminised steel formed, swaged and expanded without recourse to stress inducing welding. 409 and 316 grade stainless steel options available. Burners Multi burner in-shot carefully matched to each tube assembly and manifolded to a common gas valve and ignition system, itself complete with flame monitoring and safety controls and supplied ready for use with Natural Gas (G20). Alternative PG propane (G31) firing available to order. Air Movement Via dynamically balanced and resiliently mounted direct drive centrifugal fan sets. Freeblowing heaters are equipped with heads providing rotational and lateral jet direction and where applicable, are of extended height. Heaters arranged for ducted applications are provided with an outlet spigot for the onward connection of ductwork. Controls Heaters are supplied ready for automatic operation and are complete with safety and comfort controls. As standard heaters will be provided with the optimised entry code protected control MC200V3(mandatory for high/low and modulating applications) which includes a digital time switch and integral day and frost protection sensors. Remote temperature sensor option available. Alternatively heaters may be specified with our Powrtrol control, a digital time switch, mechanical day temperature and night set-back thermostats. For installer convenience heaters controls are factory fitted as standard but remote stations available as an option. All heaters have the ability to provide fan only summer air movement. Configuration Powrmatic VPC gas-fired cabinet heaters are vertical in configuration and, dependent upon model, can be specified to provide on/off, high/low or modulated heat outputs. Approvals All Powrmatic heaters are type tested to meet the stringent requirements of the Gas Directive and are CE approved. 2

Duties VPC UF / VPC UD Model 30 52 80 110 130 Output kw 30 52 80 110 130 Input (nett CV) kw 32.6 56.5 87.0 119.5 141.3 Volume m 3 /s 0.87 1.59 2.34 2.96 3.63 Airflow Electrics Heads No. 3 3 4 4 4 Throw m 12.0 22.0 21.0 26.0 27.0 Fan Static Supply Standard Fan Standard Pa 150 200 225 150 200 Uprated Pa (Refer to Powrmatic) Standard V/ph/Hz 230/1/50 Optional V/ph/Hz n/a 400/3/50 Motor kw 1.16 1.0 2.6 1 x 1.5 1 x 2.2 Start amp 6.5 8.3 19 28 40 Run amp 4.5 5.8 11.4 9.3 10.7 Connection BSP/Rc ¾ Minimum Inlet Nat Gas mbar 20.0 Fuel Pressure PG mbar 37.0 Consumption Nat Gas m 3 /h 3.45 5.98 9.19 12.64 14.94 PG m 3 /h 1.33 2.31 3.55 4.89 5.78 Height mm 2257 2713 2804 2715 2998 Overall UF Upright Dimensions Freeblowing Width mm 750 750 750 750 750 Depth mm 1108 1108 1412 1767 1767 Front mm 1000 Installation UF Upright Blank Side mm 150 Clearances Freeblowing ouvred Side mm 500 Rear mm 500 Diameter mm ø 100 130 Flue Flue Only m 12 Maximum ength Room Sealed m 6 Combustion Air Spigot mm ø 100 130 Noise evel db(a) 60 68 76 72 74 Nett Weight kg 178 248 305 362 410 Notes - Fuel consumption and output figures based upon nett calorific values as follows -Natural gas (G20) nett CV 34.02 MJ/m³ -Propane (G31) nett CV 88.00 MJ/m³ Heaters have efficiency levels which meet with the minimum heater efficiency requirements of UK Part Building Regulations Air handling data is assessed at room ambient conditions Throw figures provide the distance to the point where the terminal velocity degrades to 0.25 m/s Overall vertical heater height include heads or extended heads where appropriate Standard height heads can be specified where site height is restricted Blank and louvred lower side panels are interchangeable Noise levels are applicable to standard UF models and are measured 5m from appliance and in free field conditions Motor kw, run and start amps apply to standard electrical supply as stated. For optional data contact sales office Flue and combustion air maximum runs for guidance purposes only. Please refer to installation instructions for detailed information Connection of combustion air duct is not required for flue only applications It is the responsibility of the installing contractor to ensure that ductwork is correctly sized and balanced when installing ducted units Installer guidance notes on rear page 3

Dimensions J 1 J J 1 J K H G M COMBUSTION AIR INET M EXHAUST AIR OUTET Ø D ATERNATIVE FUE & COMBUSTION AIR POSITIONS E H 50 M G C GAS ENTRY F B A B Model A B C D E F G H J J1 K M Head Plan 30 1108 750 1676 100 265 1378 142 237 286 581 256 657 650 2 52 1108 750 2132 100 265 1832 142 237 286 581 256 657 650 2 80 1412 750 2132 130 265 1756 220 237 340 672 308 960 650 3 110 1767 750 2043 130 265 1667 220 237 340 672 308 1315 650 4 130 1767 750 2209 130 265 1835 220 237 400 788 358 1315 650 3 Head Plan 2 Head Plan 3 Head Plan 4 4

Dimensions Side / Rear Inlet Spigot Side / Rear Filters Side / Rear Dampers 50 SIDE REAR 136 SIDE REAR 136 185 SIDE REAR 185 50 760 760 760 760 650 N 650 750 N 650 750 UPRIGHT HEATER SPIGOTS UPRIGHT HEATER FITERS UPRIGHT HEATER DAMPERS Model 30 52 80 110 130 657 960 1315 N 757 1060 1415 Flue Arrangements Room Sealed - Vertical Flue System Room Sealed - Horizontal Flue System Flashing engths Single to twin adaptor Single to twin adaptor 6m maximum Combustion air socket Combustion air duct 6m maximum Flue Only - Horizontal Flue System Notes for all systems: 1. Final overall of adjustable disconnection piece must be between 360-415mm. 2. 45 offsets may be used if required. Each set is equivalent to 0.5m of flue. 3. Where VPC heaters are used in clean environments it is permissible to take the combustion air directly from the heated space. The supplied mesh intake plate must be fitted to the combustion air inlet on the rear of the heater. engths Combustion air socket s Condensate drain Flue Only - Vertical Flue System (fitted with inlet grille) Flashing engths engths 12m maximum (fitted with inlet grille) (fitted with inlet grille) Condensate drain 12m maximum (fitted with inlet grille) 5

Your Installer Guide General The following notes are provided as a guide, however installers and operators should fully acquaint themselves with the more detailed guidance provided in the relevant installation manual. For copies of such manuals please consult our technical department or visit our website - www.powrmatic.co.uk Standards All Powrmatic VPC heaters must be installed, commissioned and operated with due regard to appropriate regulations including but not limited to BS 6230, relevant Codes of Practice, the possible requirements of ocal Authorities, Fire Officers and insurers as well as the installation manual. Position & ocation Heaters should be installed on a level non-combustible base. Consideration should also be given to flue routes and points of exit, gas, electrical and where applicable control connections, the throw characteristics of the heater, issues of public access and in the instance of remote temperature sensors the position needs to be representative of the zone temperature to which they refer. Heaters should not be installed in hazardous areas or areas where there is a foreseeable risk of flammable or corrosion inducing particles, gases or vapours being drawn into the combustion air or main fan circuits. Areas where special consideration or advice may be required could include but is not limited to - Where de-greasing solvents are present, even in minute concentrations Where paint spraying is carried out Where styrenes or other laminating products are used Where airborne silicone is present Where petrol engined vehicles are stored or maintained Where dust is present (i.e. wood working or joinery shops) Where high levels of extract persist Installation in such areas may be possible under specific conditions. Please consult our technical department for further information. Plant Room or Enclosure ocations Specific requirements exist where heaters are to be installed within plant rooms or enclosures. Such requirements cover the provision of positive ductwork connections as well as ventilation for combustion air and general plant room or enclosure ventilation. It is recommended that you consult with our technical department or the installation manual prior to installation. Combustion Air & General Ventilation Within the United Kingdom mandatory regulations apply concerning the provision of combustion air and general heater ventilation. Where a heater is installed in room sealed mode (ie where both the flue exit and combustion air are positively connected to atmosphere) then there is no specific requirement for combustion air ventilation. However, depending upon location, provision for general ventilation may still be a necessity. If the heater is installed in flue only mode and directly within the heated space and where that heated space has a natural ventilation rate greater than 0.5 air changes per hour then combustion air and general heater ventilation is probably not required. If the heated space has a natural ventilation rate of less than 0.5 air changes per hour then either natural ventilator openings or mechanical ventilation will be required. Please consult the installation manual for further details. Installation Clearances Particular clearances may be necessary for the correct and safe function of the heater as well as for maintenance purposes. Such clearances are confirmed in the relevant installation manual. Flue Powrmatic VPC heaters can be installed in either room sealed or flue only mode. Each heater requires a separate flue and/or combustion air intake system of the appropriate size and type. Installers are reminded that type approval has been granted for these appliances on the basis that they are fitted with Powrmatic VPC flue systems. Maximum s apply and should be strictly observed. Systems may be installed in either the horizontal or vertical plane. In either case the number of bends kept to a minimum and regard must be given to the reduction in permissible with the addition of each bend. The flue must be adequately supported and terminated with the approved terminal assembly, with due regard to the point of exit and it s proximity to any windows, doors or ventilation intakes etc. Pipework Care should be taken when sizing pipework to ensure that minimum gas inlet pressures are not compromised under dynamic load conditions. Isolating valves and service unions should be provided for each heater and pipework installed with due regard for relevant standards and Codes of Practice. Guarantee Powrmatic VPC heaters are provided with a comprehensive guarantee covering both the heater and the heat exchanger. For United Kingdom sales the heater has the benefit of a two year parts and one year labour guarantee whilst the heat exchanger assembly has a ten year sliding scale time related warranty. All guarantees are subject to terms and conditions. Powrmatic imited Hort Bridge Ilminster Somerset TA19 9PS tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk Powrmatic Ireland 45 Broomhill Close Tallaght Dublin 24 tel: +353 (0) 1452 1533 fax: +353 (0) 1452 1764 e-mail: info@powrmatic.ie web: www.powrmatic.ie Powrmatic pursues a policy of continuous improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure. Issue 5.4 December 2015