MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

Similar documents
TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

UltraDry s Features and Benefits

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Model FDT FDT A FDT FDT A FDT FDT A FDT FDT A. Model DMP DMP DMP DMP

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

A Primer for Air Dryer Selection

Installation, Operation, and Maintenance Manual Balston Model 76-01, 76-02, 76-10, and Membrane Air Dryers

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Thermo Scientific Model 1160 Principle of Operation

Refrigeration air dryer

Rotary type Oil-free Air Compressor General Catalogue. Oil-free Scroll Air Compressor Oil-free Claw Air Compressor

industry revolves around VMMD Series Membrane Air Dryer

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

CMMD Series Membrane Air Dryer

Climate Control System

PET Drying Technology

1998 Expedition/Navigator Workshop Manual

BULLETIN: APPL-QAF-133R1

simatec technologies for plastics industries

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

Pressure Switches Precautions 1 Be sure to read this before handling.

Membrane Technologies DMD Series Dryers ESM Series Dryers

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

P3X Series Membrane dryers

DRYAIRE MEMBRANE AIR DRYING SYSTEM MODEL 6770

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

Membrane Air Dryer IDG10,IDG10H IDG20,IDG20H

Low dew point type. Discrete standard dew point type (SD3015-B) (SD3035-B) (SD3050-B) (SD3075/4050-B) (SD4075-B) (SD4100-B) (SD3015-A)

Refrigerated Air Dryer

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

Nitrogen Generation Systems Compressed Air Dryers

SD Membrane Dryers Quality Air Solutions

Refrigerated Air Dryers

Refrigerated Air Dryer

Atlas Copco. Quality Air Solutions SD Membrane Dryers

Chapter 9: The basics of air preparation

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

Hollow Fiber Membrane Filter Type Air Drier Unit Type

KITZ MICRO FILTER PRODUCTS CATALOG R GUN G R DRYER

Refrigerated Air Dryers

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Compressed Air Filters

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

% by up ctoond re-heater and

Membrane Dryers KMM Series

DRYAIRE DESICCANT SYSTEM MODEL 6760

Refrigerated Air Dryer

SYNRAD Technical Bulletin # 0015d

Refrigerated Air Dryers

The Complete Guide to Gas Sample Drying for Your Analyzer or Process

Membrane Air Dryer IDG30 A IDG50 A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA

Refrigerated Air Dryer

Specifications. The Liquid Super Separator is a new concept of air filtration that is totally different from

DELTA FILTER. G 3/8 to G 2

Moisture Control Tube

Membrane Dryers KMM Series

R-407A R-448A R-449A

Catalog 9CW-SD-9 Manual Desiccant Dryers Models X0, X0, X0 and X5 Wilkerson's Manual Desiccant Dryers offer the most cost effective method to remove m

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

CKD refrigerating type dryer

Adsorption Compressed Air Dryer Heatless or heater regeneration

Module 7: Air Supply System

High Efficiency Coalescers Parker Filtration 8000 Series

Refrigerated Air Dryers

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Using the DewTrak II Dew Point/ Humidity Transmitter

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Permission granted to reproduce for educational use only. Describe the problems caused by excess

CPP condensate separator series. High-performance products. Designed for you!

Adsorption Air Dryers

PRISM PE dryers membrane air dehydration... tell me more

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

High quality compressed air from generation to application

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Treatment. Compressed Air. Equipment CONTENTS

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Refrigerated Compressed Air Dryer

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

PURest Air Dryer Installation and Maintenance

clean, dry compressed air

Thermodynamics I. Refrigeration and Heat Pump Cycles

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

CLEAN, DRY COMPRESSED AIR

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Transcription:

ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate, Dry Air Dew Point, and Pressure Loss 211 Model Selection on Dry Air Flow Rate 212 Handling Instructions and Precautions 213 Caution Before use, be sure to read the Safety Precautions on p. 49. 208

Using Hollow Fiber Membranes to Dehumidify Compressed Air. No freon, no power supply Freon-free air dryer uses hollow fiber membranes for a gentle touch on the global environment. A power supply is unnecessary. No vibrations, no heat emissions, long service life No mechanical moving parts means no vibration and no heat emissions, for longer operating life. With dew point indicator Dew point indicator allows condensation check. No drain media The extracted moisture is emitted as water vapor, preventing drain media problems. Compact, lightweight Compact, lightweight body occupies 1/5th the installation space and less than 1/10th the mass (compared to Koganei refrigerating type air dryer). Application example Dehumidification of air source for precision equipment Air bearings Laser processing machine Electrical discharge machine Slicers, etc. Supply of dry air for precision measurement instruments Supply of dry air for semiconductor devices Supply of dry air for packaging equipment and printers Air control at airline ends Dehumidification Principles Order Codes Compressed air (moist air) is supplied on the inside of the hollow fiber membrane, while purged air (dry air) is supplied on the outside, creating a water vapor pressure differential between the inside and outside that allows water vapor contained in the compressed air to penetrate into the membrane, where it is exhausted to the outside alongside the purged air, in a continuous dehumidification process. Compressed air (moist air) Hollow fiber membrane Water vapor Oxygen Nitrogen Exhaust (moist air) Transmitted water vapor KRM Additional part Membrane air dryer Dew point indicator use paper Air dryer size 05 Standard dry air flow rate 1 50R/min [1.77ft. 3 /min.] (ANR) 1 Standard dry air flow rate 100R/min [3.53ft. 3 /min.] (ANR) 3 Standard dry air flow rate 300R/min [10.6ft. 3 /min.] (ANR) IN-KRM Caution: Always install a micro mist filter upstream of the membrane air dryer for use. For the order code, see p.213, Membrane Air Dryer System Diagrams. Purged air (dry air) Dry air 209

Specifications Operating pressure range MPa [psi.] 0.2 0.83 [29 120] Ambient temperature C [ F] 5 55 [41 131] 5 40 [41 104] Supply air temperature C [ F] 28 [82.4] Supply air pressure MPa [psi.] 0.69 [100] Purged air flow rate Note 2 R/min [ft. 3 /min.] (ANR) 13 [0.46] 25 [0.88] (13 [0.46]) Note 3 75 [2.65] (38 [1.34]) Note 3 C [ F] 26 10 [ 14.8 14] 26 12 [ 14.8 10.4] ( 23 10 [ 9.4 14]) Note 3 26 12 [ 14.8 10.4] ( 23 10 [ 9.4 14]) Note 3 Notes: 1. For the use of other than compressed air as media, consult us. In addition, remove moisture and oil from the compressed air. 2. Purged air can be exhausted from piping. 3. Figures in parentheses ( ) show the small value for purged air flow rate (when the supplied orifice is attached). Dimensions (mm) W E J H P F I Item Model Operating conditions Normal ratings Media Note 1 Supply air temperature C [ F] 5 55 [41 131] 5 40 [41 104] Ambient temperature C [ F] 30 [86] Vapor content in supply air Saturation at 28 C [82.4 F] Supply air flow rate R/min [ft. 3 /min.] (ANR) 33 133 [1.17 4.70] 65 205 [2.30 7.24] (53 193 [1.87 6.81]) Note 3 195 615 [6.89 21.71] (158 578 [5.58 20.41]) Note 3 Dry air flow rate R/min [ft. 3 /min.] (ANR) 20 120 [0.71 4.24] 40 180 [1.41 6.36] 120 540 [4.24 19.07] Mass kg [lb.] 0.4 [0.88] 0.4 [0.88] 0.9 [2.0] Air Relationship Between Operating Conditions and Dry Air Dew Point Supply Air Pressure and Purged Air Flow Rate The air dryness increases with higher air pressure, lower temperature, and less flow rate. Larger purged air flow rate also boosts air dryness. Low Supply air pressure Low Purged air flow rate Low Low Low Supply air temperature Low Supply air flow rate Low Low When the purged air flow rate is large, the purged air flow rate can be cut almost in half by switching to the orifice provided. In this case, the dew point will rise slightly. Types of orifice Purged air flow rate R/min ANR Standard Supplied Orifice D Orifice C Orifice D Orifice A Orifice B Orifice A Orifice B Orifice C Orifice D Supply air pressure MPa 1MPa = 145psi. 1R/min = 0.0353ft. 3 /min. O Cap for changing of orifice IN B A OUT Supply air intake V Dry air outlet Bracket mounting thread, (M4 0.7, Depth 8), (M5 0.8, Depth 10) Dew point indicator K Connection port Rc1/4 Rc1/2 G L Purged air outlet Note Purged air piping port Note: If discharging purged air into the area immediately surrounding the membrane air dryer is unacceptable, connect the purged air discharge piping. When the piping is connected, the discharge from the purged air outlet will cease. Code Model A 53.5 69 B 40 50 E 46 66 F 13 15 G 25 30 H 175 220 I 150 190 J 161 200 K 12 17 L 70 100 O 82 124 P 12 16 V 6 6 W 10 10 210

Dry Air Flow Rate, Dry Air Dew Point, and Pressure Loss Supply air: At 0.3MPa [44psi.] (saturation at 28 C [82.4 F]) C (Orifice D) (Orifice D) (Orifice B) (Orifice A) MPa (Orifice C) Dry air flow rate R Supply air flow rate R Pressure loss Supply air: At 0.5MPa [73psi.] (saturation at 28 C [82.4 F]) C (Orifice D) (Orifice B) (Orifice D) (Orifice A) (Orifice C) Dry air flow rate R Supply air flow rate R Pressure loss MPa Supply air: At 0.7MPa [102psi.] (saturation at 28 C [82.4 F]) C (Orifice D) (Orifice C) (Orifice B) (Orifice D) (Orifice A) Pressure loss MPa Dry air flow rate R Supply air flow rate R Remark: The dry air dew point can change, depending on the purged air volume. Replacement of the orifice inside the membrane air dryer body will change the purged air volume (, only). F = 9C/5 32, 1R/min = 0.0353ft. 3 /min., 1MPa = 145psi. Dew Point and Relative Humidity Conversion Table 211 Dew point C [ F] 30 [86] 25 [77] 20 [68] 15 [59] 10 [50] 5 [41] 0 [32] 5 [23] 10 [14] 15 [5] 20 [ 4] 25 [ 13] 30 [ 22] 35 [ 31] 40 [ 40] Relative humidity % Air temperature 10 C [50 F] Air temperature 20 C [68 F] Air temperature 30 C [86 F] 100 71 50 33 21 13 8.4 5.1 3.1 1.8 1.0 100 73 52 37 26 17 11 7.1 4.4 2.7 1.6 1.0 0.55 100 75 55 40 29 21 14 9.5 6.1 3.9 2.4 1.5 0.89 0.52 0.30

Model Selection on Dry Air Flow Rate How to select the most suitable model Selection formula Standard dry air flow rate Pressure correction coefficient Dry air flow rate Temperature correction coefficient If the dry air flow rate is 20R/min [0.706ft. 3 /min.] (ANR) or less, certain conditions may prevent some models from being selected. Consult us. Dew point correction coefficient Selection example 1 Conditions Dry air flow rate: 100R/min (ANR) Supply air pressure: 0.5MPa Supply air temperature: 35 C : 10 C From the conditions at left: Dry air flow rate 100R/min (ANR) Supply air pressure: At 0.5MPa, Coefficient Table 1. gives a correction coefficient of 0.45. Supply air temperature: At 35 C, Coefficient Table 2. gives a correction coefficient of 0.6. : At 10 C, Coefficient Table 3. gives a correction coefficient of 2.2. 100 0.45 0.6 2.2 168 Using the Standard Dry Air Flow Volume and Orifice Table, 168R/min (ANR) is satisfied by (Orifice B), due to its standard dry air flow rate of 240R/min (ANR). Selection example 2 Conditions Dry air flow rate: 50R/min (ANR) Supply air pressure: 0.7MPa Supply air temperature: 35 C : 10 C F = 9C/5 32, 1R/min = 0.0353ft. 3 /min., 1MPa = 145psi. From the conditions at left: Dry air flow rate 50R/min (ANR) Supply air pressure: At 0.7MPa, Coefficient Table 1. gives a correction coefficient of 1.0. Supply air temperature: At 35 C, Coefficient Table 2. gives a correction coefficient of 0.6. : At 10 C, Coefficient Table 3. gives a correction coefficient of 2.2. 50 1.0 0.6 2.2 38 Using the Standard Dry Air Flow Volume and Orifice Table, 38R/min (ANR) is satisfied by (Orifice D), due to its standard dry air flow rate of 50R/min (ANR). F = 9C/5 32, 1R/min = 0.0353ft. 3 /min., 1MPa = 145psi. Standard Dry Air Flow Rate and Orifice Table Model Standard dry air flow rater/min [ft 3 /min] (ANR) 50 [1.77] 80 [2.82] 100 [3.53] 240 [8.47] 300 [10.59] Orifice Orifice D Orifice D Orifice C Orifice B Orifice A Coefficient Tables 1. Supply air pressure correction coefficient table Supply air pressure MPa [psi.] 0.2 [29] 0.29 [42] 0.39 [57] 0.49 [71] 0.59 [86] 0.69 [100] 0.78 [113] Correction coefficient 0.05 0.14 0.27 0.45 0.70 1.0 1.4 2. Supply air temperature correction coefficient table Supply air temperature C [ F] 0 [32] 5 [41] 10 [50] 15 [59] 20 [68] 25 [77] 28 [82.4] 30 [86] 35 [95] 40 [104] 45 [113] 50 [122] 55 [131] Correction coefficient 7.6 5.3 3.7 2.6 1.8 1.2 1.0 0.9 0.6 0.42 0.30 0.21 0.14 3. correction coefficient table C [ F] 30 [ 22] 25 [ 13] 20 [ 4] 17 [1.4] 15 [5] 10 [14] 5 [23] 0 [32] 5 [41] 10 [50] Correction coefficient 0.22 0.4 0.7 1.0 1.3 2.2 4.0 7.1 12.5 22 212

Membrane Air Dryer System Diagrams (Reference) Caution: Always mount an air filter (5 m) and micro mist filter (0.01 m) upstream of the membrane air dryer for use. Air filter (5 m) Connection module Micro mist filter (0.01 m) Connection module Membrane air dryer Connection module Regulator With auto drain Note F150-02 8-20D MMF150-02-A Note 8-30F denotes the absolute minimum system. Note: Some models without an auto drain are available. To order such models, remove -A from the order code. 8-20D R150-02 F300-03-A Note 8-40D MMF300-04-A Note 8-60F 8-40D R300-03 Handling Instructions and Precautions Mounting and piping 1. Install in locations where the supply air and ambient temperature is 40 C [104 F] or less (for, 55 C [131 F] or less). 2. If connecting piping to the air compressor outlet port, use air that has passed through an aftercooler to cool the temperature at 40 C [104 F] or below, then install a filter and micro mist filter to prevent intrusion of oil mist to the membrane air dryer. 3. The membrane air dryer cannot operate on its own to remove water vapor or collected liquid. If water vapor or collected liquid is intruding, use a filter and micro mist filter. 4. For the mounting method, install vertically with the piping connection part on the top. In addition, leave a space to facilitate maintenance. (minimum of 100mm [3.94in.] from the floor) 5. The membrane air dryer discharges constant purged air from the purged air outlet. If discharging purged air into the area immediately surrounding the membrane air dryer is unacceptable, remove the cover of the purged air piping port and plumb piping for the purged air discharge. When the piping is plumbed, the discharge from the purged air outlet will cease. If using piping connection fittings 8-30F or 8-60F to connect the micromist filter and membrane air dryer, screw in the quick fitting first before making the connection. The quick fitting cannot be screwed in after the connection is completed because of interference with the micro mist filter. Recommended fittings : SLH6-01 : SLH6-01 : SLH10-02 Indicator Check the color of the indicator during the daily inspections. Blue means that the situation is normal. If the outlet dew point is rising, the color will change to pink or white. In such a situation, see the instruction manual provided with the product, under Causes of Breakdowns and Abnormalities, and Countermeasures. General precautions 1. Always thoroughly blow off (use compressed air) the piping before plumbing. Entering chips, sealing tape, rust, etc., generated during plumbing could result in air leaks or other defective operation. 2. The product cannot be used when the media or the ambient atmosphere contains any of the substances listed below. Organic solvents, phosphate ester type hydraulic oil, sulphur dioxide, chlorine gas, chlorofluorocarbon or acids, etc. 3. If using in locations subject to dripping water, dripping oil, etc., or to large amounts of dust, use something to cover and protect the unit. 213