ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

Similar documents
FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

FIREMASTER CONCERTINA TM

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT SPECIFICATION FireMaster Plus

FIRE & SMOKE CURTAINS

FIRE & SMOKE CURTAINS

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

PRODUCT SPECIFICATION FireMaster Plus Concertina

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

PRODUCT SPECIFICATION FireMaster Concertina

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

A REVOLUTIONARY APPROACH TO FIRE SAFETY

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Firetex steel fire shutters

Operation & Maintenance Manual

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

CI/Sfb ( ) smoke stop. Smoke Barriers for all applications... Swiss Re London. Lane Crawford Singapore. London.

Technical Manual (European Standards)

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

FM MEDICOL. Cableflow International Limited. The FLUSH MEDICOL (FM) Patient Care Services. Column has evolved from a market requirement for a

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

ACTIVE FIRE CURTAINS INTISI7

Smoke and Fire Curtains

Fire detection and alarm

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

Fire Suppression Systems

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

fire resistance testing

PANEL. Cableflow International Limited

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (Student Halls of Residences & Sleeping Accommodation)

Technical Specification

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

ES 200. Sliding door operator

Eaton training solutions Accredited CPD seminars. LED Emergency and Mains Lighting Contents. Knowledge for your business

FIRE DOOR CLOSING SYSTEMS

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Installation and user manual for the BiWire / Conventional Repeater Panel

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

GENERAL FIRE SAFETY TERMS & DEFINITIONS

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

The Association for Specialist Fire Protection. Understanding Best Practice in passive fire protection

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Opal TM AV Devices. Data Sheet. Benefits

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

H Y D R O C O U R S E T R E N C H H E A T I N G

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

WARNING FIRE DOOR CLOSING

EH1688. Over Door Heater & Fan Chauffage de Porte & Ventilateur

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

Dyna-Form Air. Alternating Pressure Relief Overlay System

All by design. ASSA ABLOY Door Controls

SURFACE WARM CEILING HEATERS

Gas Safety. Information for homeowners. orbit.org.uk

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

Smoke Vent Control Panel PCB4 V4 Installation Manual

THE COMPLETE SOLUTIONS PACKAGE

Safety Instrumented Fire & Gas Systems

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

1.4 Provide and fix the following ironmongery.

1 P age w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD V AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN

Getting Started Guide

ZP3 Operator & Maintenance Manual Version 1

Building Services Brochure

Touch Screen 1 loop Addressable Fire Alarm Panel

CFDAU30 Voice Alarm System

V3 Intelligent Damper Control and Monitoring System

Mechanical Smoke Extract Shaft Systems

Opal TM AV Devices. Data Sheet. Benefits

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Unity DAU Voice Alarm System

EMERGENCY ASSISTANCE ALARMS

A Guide To BS Understanding the selection, spacing and siting of detectors

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

Transcription:

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS WWW.COOPERSFIRE.COM

VII FIRE ACTIVE FIRE CURTAIN BARRIER FOR YOUR HOME AND COMMERCIAL PROPERTY. From architects to homeowners to commercial property owners, Coopers Fire Vii Fire fire curtain barriers provide you with the means to help create modern, open plan living/working environments compliant with stringent fire regulations without compromising design. Sympathetic to interior aesthetics, the Vii Fire fire curtain barrier will remain hidden until deployed and is used to replace non-loadbearing walls, fire doors and un-insulated glazing. WHAT Vii FIRE REPLACES Wall Door Glazing Serving hatches Ceiling Increasingly specified by designers as an integral component for facilitating open plan environments, Vii Fire is the modern alternative to segregating firewalls, heavy and cumbersome fire doors and is an aesthetically pleasing replacement for traditional, industrial looking shutters. HOW DOES IT WORK? Made by Coopers Fire in the UK, Vii Fire is Third Party Accredited and has been developed to withstand temperatures of 1000 C. Vii Fire will also remain sympathetic to your interior designs by staying hidden within a ceiling or void until triggered by a fire alarm or detector, deploying under the Coopers Fire patented Total Gravity Fail Safe (TGFS) system. In the event of a fire, The Vii Fire fire curtain barrier will deploy to form a protective barrier that will effectively contain and compartmentalise a fire, providing the same protection as a wall or fire door and permitting safe, tenable escape. KEY BENEFITS 2 Hour fire and smoke protection Tenable zone for protecting means of escape Guaranteed building control approval Standard and bespoke sizes Powder coat paint available in multiple colours Supply only or supply and install Inspiring open plan living APPLICATIONS PRODUCT RANGE Kitchen Door Hall & lobby Serve Loft & cellar Ceiling/sky light Laundry shoot Serving hatches Protecting non fire rated glazing forming a boundary protection Walls and floors forming a protective means of escape

ADDING TENABLE ZONE TO VII FIRE. TESTING, ACCREDITATIONS AND CERTIFICATION AT COOPERS FIRE, WE UNDERSTAND THE IMPORTANCE OF FIRE SAFETY BUT ALSO THE SIGNIFICANCE OF BLENDING YOUR FIRE CURTAIN BARRIER IN WITH YOUR HOME AND COMMERCIAL PROPERTY. If you re protecting a means of escape, a tenable zone is required to protect passing occupants from radiating heat. Coopers Fire Vii Fire i-zone is approved to provide a tenable zone in accordance with BS 8524-2:2013 and will achieve radiated heat as low as 8.4kW/m² after 60 minutes. ADDING SMOKE CONTROL All of our Vii Fire fire curtain barriers can also incorporate smoke seals to help control smoke in accordance with BS EN 1634-3:2004. Why Vii Fire? Vii Fire combines aesthetic subtlety with certified 2 hour protection reinforced by over 30 years experience. Also unique is how you purchase and install Vii Fire. Because Vii Fire is plug and play and can be installed by a competent person, you re free to purchase on a supply only arrangement, cutting both time and costs. Alternatively, Coopers Fire can project manage the installation from concept to commissioning, we ll even liaise with your Building Control Body, taking the uncertainty out of complying with Building Regulations. Vii FIRE CURTAIN BARRIER COMBINES AESTHETIC SUBTLETY WITH CERTIFIED 2 HOUR FIRE PROTECTION Reveal fix Face fix ACCREDITATIONS BS 8524-1-2013 BS EN 1634-1:2008 BS EN 1634-3: 2004 BS 476-6:1989 BS 476-7:1997 ISO 9001:2008 ISO 14001:2004 Meets the self closing without power fire safety requirement (Approved Document B) SUPPLY ONLY Vii Fire can also be supplied as a supply only option and is suitable for installation by a competent person. SUPPLY AND INSTALL WITH FULL PROJECT MANAGEMENT Whether you re an architect, contractor or a home owner, Coopers Fire team of project managers and installers are dedicated to ensuring that your project meets stringent fire regulations whilst remaining sympathetic to your domestic or commercial design. Furthermore, Coopers Fire are Third Party Accredited for installation, commissioning and service.

ALARM FAULT POWER (MUTE) Coopers Fire Ltd Penner Road Havant PO9 1QZ For Service and Maintenance contact UK www.coopersfire.com 0800 6335224 +44 (0) 2392 454 405 OK OPTIONS FOR FITTING AND CONCEALING THE HEAD BOX OPTIONAL EXTRAS With head boxes and fixing options to suit all types of ceiling configurations, Vii Fire curtain barriers are both flexible and sympathetic to interior aesthetics. FACE FIX - HEAD BOX REVEAL FIX - HEAD BOX CONTROL OPTIONS Motor Cable MANDATORY SAFETY FUNCTIONS * * FACE FIX - SIDE GUIDE * * REVEAL FIX - SIDE GUIDE 230V AC 50Hz 13A dedicated unswitched Socket (by others) Bump Stop* Obstruction Warning* Light Warning* Voice Warning* BMS 1* BMS 2* Closed volt-free contacts. Open on alarm activation. Open on fail safe. (by others) Power Supply Unit o/a (mm) 350(w) x 115(h) x 110(d) *Optional Accessory MK5 CONTROLLER CAN 2* Remote MCP* Fireman s Retract* Detector 2* Detector 1* Emergency Retract Button Options BS 8524 compliant Total Gravity Fails Safe (TGFS) Total wiring corruption fail-safe by gravity Total control equipment fail-safe by gravity Safe controlled operating speeds Battery backup Automatic self-test enabled * i-zone * Access to the headbox is gained by the front panel. QUALITY ASSURANCE AND CERTIFICATION IF FACE FIX Use the largest dimension as your unit opening width. IF REVEAL FIX Use the smallest dimension as your clear opening width. MEASURING AND ORDERING 1. Check that all walls and surfaces are suitably fire rated. 2. Ensure all fittings, if different to the standard fittings supplied are suitably fire rated and load rated. Please refer to your fixings supplier. 3. Guarantee that there are no obstructions, pipes, cables or tiles. 4. Measure the width of the opening at the top middle and bottom. CRITICAL PERFORMANCE OPTIONS Fire integrity only Fire integrity and smoke protection Fire integrity and tenable zone Fire integrity, tenable zone and smoke protection OPTIONAL EXTRAS Voice warning Audio / visual beacon Heat detector Smoke detector Beam detector Light curtain Bump stop, bottom bar edge protection Emergency retract button/s MEMBERSHIP CPD ACCREDITATIONS

TECHNICAL INFORMATION Power 230Vac 50Hz via IEC power inlet (110Vac available on request) Mechanical Headbox: Backplate: End Plates: Side Guides: Bottom Bar: Mild Steel 18 swg (1.2mm) Mild Steel 18 swg (1.2mm) Mild Steel 14 swg (2.0mm) Mild Steel 18 swg (2.0mm) Mild Steel 18 swg (2.0mm) Accessory Fuse 1A anti-surge (T1A) Battery Fuse 3.15A anti-surge Batteries 2 no. 12V, 1.2AHr Sealed Lead Acid in series Pair of normally closed volt-free contact (by others) smoke detector or heat detector, test key-switch ELECTRICAL INFORMATION Motor 24Vdc Patented Total Gravity Fail Safe (TGFS) Controls Emergency power unit plug and play pre-wired Mild Steel 340 Width x 200 Height x 70 Depth (Clearance is required for connectors) Sockets Motor IEC Main in Detector (smoke/heat) Obstruction Detector (beam or curtain) Bump stop, bottom bar edge protection Emergency Retract Audio/Visual Beacon Voice Warning Series v08 April 2018 For information, to get a quote or to book a CPD workshop Please call: +44 (0)2392 454 405 or E-mail: info@coopersfire.com WWW.COOPERSFIRE.COM Coopers Fire Ltd, Edward House, Penner Road, Havant, Hampshire, PO9 1QZ United Kingdom Phone: +44 (0)2392 454 405 Fax: +44 (0)2392 492 732 Email: info@coopersfire.com Web: www.coopersfire.com Coopers Fire Ltd has a policy of continuous product improvement. As such we reserve the right to change design and specifications without prior notice. Please check our website for the latest information. Coopers Fire Ltd. All content and products are copyright of Coopers Fire Ltd. Registered in England Number: 2010274. Multiple patents granted and pending.