EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Similar documents
evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04

Evolution Analogue Addressable Fire System

Instruction Manual EVA-PY

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

Instruction Manual EVA-STB-RL

SOUNDER CONTROL MODULE SCM-AS4

Premier External TD. Installation Manual INS352-3

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

Operating instructions for the radio heat detector GS412

Series 65 Product Guide MAN 3036

HULME MARTIN HEAT SEALERS

Instruction Manual EVA-DPH


1. Safety instructions Mounting location in rooms of the heat detectors... 3

HEP Tech Co., Ltd. Company Profile

HULME MARTIN HEAT SEALERS

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

NITTAN. EVOLUTION April 2009 EVC-DP Conventional Dual Optical Detector TECHNICAL DATASHEET. Part Numbers and Product Order Codes:Part Number

Aqua Dri AIR MOVER / CARPET DRIER SAFETY, OPERATION & MAINTENANCE INSTRUCTIONS

CONTENTS NBM-06 Bell (6") Page 1

optical detector multisensor detector heat detector mounting bases product guide

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

PQS performance specification

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Use & Care Manual Inset Electric Fires

Reflective Beam Smoke Detector

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

OH110, OP110, HI110 Automatic fire detectors

Instruction Manual EVA-S6 Base

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE

OH720, OP720, HI720, HI722


OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Touch Screen 1 loop Addressable Fire Alarm Panel

Owner & Operator s Manual. Table of Contents

INSTRUCTION MANUAL. This product is only suitable for well insulated spaces or occasional use.

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Installation and Operation Manual

PQS performance specification

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Use & Care Manual Contemporary Electric Fires

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Installation Manual. Premier IXP-W INS538

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Installation Manual Premier Elite IXP-W

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base

IFD-E Flame Detector User Manual

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

IFD-E Flame Detector User Manual

E-PDD Duct Smoke Detector Installation Sheet

Important Safety Notice

LASER ASPIRATED SMOKE DETECTOR

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Fortimo LED Line High Flux Module

Fortimo LED Line Gen2 Module

ADR 20N SELF CONTAINED OPTICAL SMOKE DETECTOR

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

Record of Amendments. Version Date Amendment Section/page affected

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

FIGARO. 08/52543/0 (UK) Issue 1

Instruction Manual. Electronic gas and smoke detector GRM

FEC403EN Installation Manual

FX-PDD Duct Smoke Detector Installation Sheet

Room Temperature Sensors

Conventional Smoke Detectors KFAPO

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Features. Figure 1. Recommended Application

Dual SDI Optical to Electrical Converter

LASER ASPIRATED SMOKE DETECTOR

USE & CARE MANUAL. ELECTRIC FIREPLACE SUITE (remote control operated) ADI0010 V

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Dräger Flame 3000 Visual Flame Detector Instructions for Use

scorpion User Manual Remote Tester for Point Smoke Detectors & Aspirating Smoke Detection (ASD) Systems

Operating instructions for the wireless smoke alarm detector type: GS558

Analogue addressable devices

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

RMS-I-DE-01 Smoke Detector

3kW 6kW, QUBE Fiber Lasers

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

Pyroelectric Infrared Sensors

4) Intrinsic Safety Certification

Operating Instructions

PHOTOELECTRIC REFLECTIVE BEAM DETECTOR MODEL SRA-ET. Mounting Guidelines

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

FDOOT221, FDO221, FDT221

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Transcription:

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR instruction manual Ref No: NISM/EVC-P/03 Date: Jan 2010 Issue: 3 Quality System Certificate No. 041 Assessed to BS EN ISO 9001:2000 NITTAN (UK) LTD. Hipley Street, Old Woking, Surrey, England, GU22 9LQ. UK Tel: +44 (0) 1483 769555 Fax: +44 (0) 1483 756686 Web Site: www.nittan.co.uk E-mail: sales@nittan.co.uk

evolution... The EVC-P Photoelectric Smoke Detector forms part of a range of fire detectors from Nittan (UK) Ltd called evolution. The EVC-P is an elegantly designed, low profile detector which is aesthetically pleasing, thus enabling it to blend unobtrusively into modern working environments. The EVC-P is compatible with other existing conventional fire detection systems. 2

Section 1 - INTRODUCTION The EVC-P is an attractively-styled, low profile photoelectric smoke detector for use in conventional fire detection systems. CONTENTS: Section 1 Introduction Page 3 Section 2 Operation Page 3 Section 3 Detector Models Page 4 Section 4 Base Models Page 4 Section 5 Installation Page 5 Section 6 Maintenance & Cleaning Page 5-7 Section 7 Specification Page 8 Section 8 Environmental Parameters: Page 9 - Temperature Page 9 - Humidity Page 9 Section 9 EMC Page 9 Section 10 Connections Page 10 Section 11 Dimensions Page 10 Section 12 Disposal Page 11 Section 13 ROHS Compliance Statement Page 11 The EVC-P has a chemically etched, stainless steel insect screen therefore reducing the ingress of insects and airborne contaminants. EVC-P features: Optical detector, detecting visible particles of combustion Low profile, stylish appearance Supplied with protective dust cover, (remove during commissioning) Non-polarised terminals Unauthorised head removal signal facility Low monitoring current OMNIVIEW 360º LED fire alarm indicator Remote indicator output Compatible with UB-4, UB-4SD and STB-4SE bases Section 2 - OPERATION The smoke chamber of the EVC-P is constructed so that light cannot enter from outside, but smoke can pass through the chamber slots. The EVC-P utilises the light scatter sensing principle. The LED pulses every 8 seconds to maintain a low monitoring current. A quick charge time (20 seconds) is also achieved. The detector incorporates an alarm verification function which requires two successive pulses before an alarm is given. The interval between the first and second pulse is automatically reduced to four seconds after the first alarm level is monitored. The detector design provides strong immunity to air velocities, contamination and RF interference. The geometry of the smoke chamber and optics support assembly is designed to give the best possible signal to noise ratio, resulting in excellent response characteristics. 3

Section 3 - DETECTOR MODELS The EVC-P photoelectric smoke detector is supplied, as standard, with four terminals. The EVC-P has the facility to activate a remote LED indicator or auxiliary function, as standard. The terminals on the EVC-P detector head are configured as follows: Terminal 1 = zone negative in Terminal 3 = zone positive in/out Terminal 6 = zone negative out Terminal 5 = 2 ma @ 24V d.c. switched output Section 4 - BASE MODELS A variety of bases are available for use with the EVC-P detector. It is important to use the correct base for each application. The standard range available is as follows: i) UB-4 base: having 4 terminals, for standard use with EVC-P detector including the auxiliary output function. ii) UB-4SD base: This is identical to the standard STB-4 base, but also includes a schottky diode for head removal fault monitoring. The schottky diode is used in some fire systems to ensure power is maintained, in the event of an unauthorised detector head removal, to other detectors further on the zone. iii) STB-4SE base: Similar to UB-4 base, except deeper. 4

Section 5 - INSTALLATION In normal use, the EVC-P detector will be installed at ceiling level. Pass the field wiring through the cable hole in the centre and from the rear of the base. Offer up and affix the base to the ceiling or conduit fitting with screws via the base mounting holes. Connect the field wiring to the base terminals, as detailed on page 6 making sure the wiring does not obstruct fitting of the detector head. Fit the detector head by inserting it into the base and turning clockwise until the notch in the detector rim aligns with base locking screw. The OMNIVIEW 360º indicator permits visibility from any angle. Fit the plastic dust cover supplied over the detector to keep out dust etc, until the system is commissioned. If the dust cover is not fitted and the environment is slightly dusty, such as when building work is being completed, for example, problems of false alarms are likely to occur after commissioning unless cleaning of the detector is undertaken. At commissioning, the dust cover should be removed and discarded. NOTE: THE PLASTIC DUST COVER MUST BE RE- MOVED FROM THE DETECTOR IN ORDER FOR THE DETECTOR TO FUNCTION CORRECTLY. Section 6 - MAINTENANCE AND CLEANING Maintenance: The EVC-P detector is a high quality product engineered for reliability. In order to obtain optimum performance, periodic maintenance is required. If proper preventative maintenance is not carried out, there is a likelihood of malfunction, as a dirty detector is more likely to cause a false alarm. Servicing: Servicing of the system should be carried out in accordance with the requirements of BS 5839 Part 1, Fire Detection and Alarm Systems for Buildings: Code of Practice for System Design, Installation and Servicing. 5

The maintenance procedures described below should be conducted with the following frequency: One month after installation: Routine Inspection and every 3 months thereafter. Every 6 months: Operational Test Every 12 months: Functional Test and Cleaning. All above frequencies of maintenance are dependent on ambient conditions. Routine Inspection: i) Ensure the detector head is secure and undamaged. ii) Check the smoke entry apertures are in no way obstructed. iii) Ensure the surface of the detector s outer cover is clean. If there are deposits due to the presence of oil vapour, dust etc, then the detector should be cleaned in accordance with the cleaning instructions detailed later in this manual. It may be advisable to ensure that such cleaning is conducted regularly in the future. iv)ensure no equipment which may generate combustion products or fine airborne particles, has been installed in the vicinity of the detector since the last routine inspection. If such equipment has been installed, then you should notify the Fire Safety Officer or other competant authority that its presence may cause false alarms. Routine Inspection: The purpose of the Operational Test is to confirm the detector s correct operation in response to a smoke condition. i) Take any necessary precautions at the control panel to limit the sounding of the alarm sounders/bells and any fire service summoning device. 6

ii) Introduce a discrete amount of smoke into the detector head, e.g. using a 'No Climb -Solo' smoke test head. Check that the detector gives an alarm condition within 15 seconds. Check the LED indicator on the EVC-P detector illuminates and any remote indicator LED fitted also illuminates. iii) After the detector has given the alarm condition, reset the detector from the control panel. It may be necessary to allow a short time to elapse before resetting the detector, to allow any residual smoke from the test to disperse. iv)before proceeding to the next detector, ensure that the detector just tested does not re-operate due to the presence of residual smoke. Functional Test: The detector may be returned to Nittan (UK) Ltd for functional testing. Cleaning: Note: The detector head should NOT be disassembled. i) Carefully remove the detector head from its base. ii) Use a soft, lint-free cloth, moistened with alcohol for sticky deposits, to clean the plastic casing. iii) Using a soft bristle brush (e.g. an artist's paint- brush) carefully brush between the vanes in a linear motion away from the smoke entry apertures. iv)it is permissible to blow dust from the chamber, without removing the cover, using a clean air line. v) If the unit needs further cleaning, or is damaged or corroded, please return the complete detector to Nittan (UK) Ltd. for service. 7

Section 7 - SPECIFICATIONS Model Reference: - EVC-P Computer Reference: - F02C82200 Detector Type: - Photoelectric smoke detector Sensitivity: - 3% Obscuration per metre Supply Voltage: - 24V dc nominal (range 12V to 32V) Voltage Ripple: - 20% maximum Alarm Characteristics: - 6V d.c. in series with 375R between +(terminal 3) and - (terminals 1,6) at 25ºC Monitoring Current: - 40µA max. at 24V d.c. Alarm Current: - 50 ma. max. Charging Time: - 20 seconds Ambient Temperature Range: - -10ºC to +55ºC Standard: - EN54-7:2000 EMC Conformance: - BS EN50130-4:1996 (Immunity) BS EN61000-6-3:2001 (Emissions) Mass: - 118g (excluding base) IP Rating: - 41 8

Section 8 - ENVIRONMENTAL PARAMETERS Temperature Considerations: Over the range from -10ºC to +55ºC. Humidity: Relative Humidity of up to 95%, measured at 50ºC, non condensing. Section 9 - EMC Installation The installation shall be in accordance with the regulations either of the approval body for an approved system, or otherwise, to the national code of practice/ regulations for the installation of the fire alarm system, e.g. BS 5839 part 1. Electromagnetic Compatibility (EMC) In a site where there is an unusually high level of potential electrical interference, e.g. where heavy currents are being switched or where high levels of R.F. are prevalent, care then must be taken in the type and routing of cables. Particular care should be given to the separation of zone wiring from the cable carrying the interference. 9

Section 10 - CONNECTIONS UB Max.current through 5, 2mA @ 24V dc UB Section 11 - DIMENSIONS 10

Section 12 - DISPOSAL This symbol on the EVC-P indicates that this product must not be disposed of with household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office or your household waste disposal service. Section 13 - ROHS COMPLIANCE STATEMENT (RoHS compliant and lead-free) This product complies with the RoHS (Restriction of Hazardous Substances) directive. This product complies with the RoHS (Restriction of Hazardous Substances) directive which restricts the use of six hazardous materials in the manufacture of electronic and electrical equipment. This product complies with the European Union RoHS (Restriction of Hazardous Substances) directive 2002/95/EC which restricts the use of the following six hazardous materials in the manufacture of electronic and electrical equipment. Lead (Pb) Hexavalant Chromium Mercury (Hg) Cadmium (Cd) Polybrominated biphenyls (PBB s) Polybrominated diphenyl ethers (PBDE s) 11