It:ill:~~~=~:~in~1 FIGURE 1 HOW AIR VOLUME IS RECOVERED BY AN ADAMS REHEAT SYSTEM

Similar documents
H & HC Heat-Of-Compression Air Dryers

Untreated Compressed Air is Destructive. Protect Your Equipment and Save Money

Overview of HL series heatless regenerative dryers.

SYNRAD Technical Bulletin # 0015d

Nirvana. Cycling Refrigerated Dryers

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

A Primer for Air Dryer Selection

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

SECTION AIR COMPRESSORS AND ACCESSORIES

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

Heat of Compression Desiccant Dryers: Clearing up the Confusion

Desiccant Air Dryers. Heatless, Heated and Heated Blower

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Hybrid Instrument Air Dryer

The Complete Guide to Gas Sample Drying for Your Analyzer or Process

Meeting Your Compressed Air Treatment Needs

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

White paper Compressed air drying

Hybrid Refrigerated/Desiccant Compressed Air Dryers

Nirvana Cycling Refrigerated Dryers

HIGH INLET TEMPERATURE REFRIGERATED AIR DRYERS. GHRN Series

Technical Instructions Document No March 11, Air Compressor and Accessories. Description. Air Compressor Selection

Filters & Centrifugal Separators

Pressure Swing Desiccant Dryers

Nitrogen Generation Systems Compressed Air Dryers

Chapter 9: The basics of air preparation

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

Quality Components as a basis for Quality Equipment

SECTION AIR COMPRESSORS AND ACCESSORIES

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

Compressed Air Filters

High-Capacity Cycling Refrigerated Compressed Air Dryer. RTM Series

RNC Series SCFM Global Air Treatment

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

Air treatment solutions. Aftercoolers & condensate treatment

Refrigerated & Desiccant Compressed Air Dryer Product Selector

RNC Series SCFM Global Air Treatment

Dual Tower Heat Reactivated Desiccant Air Dryer

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

GTX Series Thermal Xchange Cycling Refrigeration Dryers GREAT LAKES AIR ANDARD ELECTRONIC DRAIN 5 -YEAR WARRANTY F PRESSURE DEWPOINT

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

EXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series

Thermo Scientific Model 1160 Principle of Operation

CNC Series Refrigerated Air Dryer CFM

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

Air Treatment Solutions. kaeser.com

DRYAIRE DESICCANT SYSTEM MODEL 6760

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

c o n d e n s e r Glossary of Terms

CONDENSATION/HUMIDITY PROBLEMS IN BREWERIES

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

TEMPERATURE CONTROL POWER COMPRESSED AIR EMERGENCY OR PLANNED, SHUT DOWN OR TURN AROUND. 24/7/ / ers-cat.com

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

REFRIGERATED AIR DRYERS

industry revolves around VMMD Series Membrane Air Dryer

HEATLESS REGENERATIVE DRYERS

Refrigerated Compressed Air Dryers

Module 7: Air Supply System

Condensate Management. Condensate Purifiers Condensate Drains

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Externally Heated Desiccant Air Dryer RP Series

Blower Purge Desiccant Dryers. CAB SERIES 1,238-12,915 scfm

Adsorption Dryers. DB 05 to 130

Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM

Refrigerated Air Dryers

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

(2) 325 tpd York Chlorine Liquefier Systems

MODULAR HIGH CAPACITY REFRIGERATED AIR DRYERS. GMRN & GMRC Series

Adsorption Dryers. AD 7 to 1300

Refrigeration air dryer

PET Drying Technology

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

DS Series. Ultraaqua Autoclean. Oil/Water Separators

Making Compressed Air and Gas Work Better

Compressed Air Systems. Scott Wetteland, CEM, DNV GL July 2018

DRYPOINT RA THE COMPLETE RANGE OF HIGHLY EFFICIENT REFRIGERATION DRYERS

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Refrigerated Compressed Air Dryers 5-6,000 scfm

SR Series Refrigerated Dryers SCFM

Drying Compressed Air

V LPM Desiccant Air Dryer Installation and Operation Manual

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

High quality compressed air from generation to application

CMMD Series Membrane Air Dryer

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Air Compressor Efficiency Opportunities. Industrial Energy Efficiency Workshop December 11, 2007

Transcription:

Compressed air is both hot and laden with moisture coming from the air compressor. It needs to be cooled and dried, and then reheated so it can be used in the manufacturing process. One traditional method of performing this job calls for the use of an aftercooler and refrigerated dryer. That arrangement, although effective, is both expensive to operate and difficult to maintain. Moisture in any compressed air system represents a major problem. One reason is a compressor uses ambient air that contains man-made pollutants. Contaminates such as carbon dioxide, sulfur dioxide, chlorine, etc. combine with moisture to form weak acids that are concentrated and corrosive in the compressed state. Cooling the process air is the first critical step toward the removal of this moisture. More moisture is condensed as the air temperature drops. However, during the cooling process as much as 30% of the total compressed air system energy (air volume) is lost. The Adams Reheat system provides the necessary cooling and at the same time restores this lost energy (air volume) back into the compressed air system. The system is so efficient that it can actually take the place of a refrigerated dryer. In other cases, it enhances a desiccant dryer's performance. Work available from the compressed air is dependent upon the volume and pressure at the point of use. Hot air has a greater volume than cold air. Therefore, hot air will do more work at the same cost than cold air. Figure 1 illustrates what happens when air is compressed, cooled, and reheated. The example involves 7,100 standard cubic feet per minute (SCFM) of atmospheric air at 14.7 PSIA and 70 F entering a two-stage air compressor and discharging at 125 PSIG. The resulting physical volume represents 1,000 cubic feet per minute (CFM) of air at 125 PSIG and 250oE It takes 1,200 horsepower to compress the air. When this air is cooled to 70 F; its volume shrinks to 748 cubic feet per minute resulting in a 25% reduction. This represents a loss of 302 horsepower of work that could have been performed if the air temperature was at 250oE By reheating the compressed air to 200 F; using the waste heat of compression from the compressor, there will THE 5 Y 5 T E MIS be a gain in air volume of 182 cubic feet per minute. This translates SO E F F I C IE N T T HAT into a 24% increase in air volume and 291 horsepower of work has I T CAN ACT U ALL Y been reclaimed using the Adams Reheat System. In addition, by T A K E THE P LAC E 0 F A reheating the air the chance for additional condensation in the air REF RIG ERA TED DRY E R. distribution system is eliminated.. While there are cases where the manufacturing process does not require 200 F process air, the operating principles are the same. R.r Adams can work closely with you to design a Reheat System that is suited to your needs. FIGURE 1 HOW AIR VOLUME IS RECOVERED BY AN ADAMS REHEAT SYSTEM It:ill:=:in1 COOLING,200 HP of Work 302 HP of Work Lost 25% decrease in air volume 291 HP of Work Reclaimed 24,(, increase in air volume 3

THREE THE REHEAT SYSTEM :.. IS DESIGNED MAIN FUNCTIONS: TO PERFORM D COOLING THE AIR The Reheat System cools process air in two steps using a regenerative heat exchanger and an aftercooler, as shown in Figure 2. The regenerative heat exchanger is unique in the system because it accomplishes two functions simultaneously through a process known as regeneration. Regeneration is a method of exchanging heat between the same fluid at different stages in the process. For example, compressed air must be cooled to remove moisture then reheated for use within the manufacturing plant. Instead of performing the entire cooling requirement in an aftercooler, the Adams Reheat System uses a regenerative heat exchanger upstream of the aftercooler to handle pan of the cooling duty. The regenerative heat exchanger's cooling source is the same process air that has already been cooled by the system's aftercooler. Final cooling then takes place in an aftercooler. This precooling arrangement can reduce the aftercooler cooling water consumption by as much as sixty (60%) percent. EJ. 0 1ST U R ERE. 0 VAL Once the air is cooled, the condensed moisture can be effectively removed. Using a cyclone separator; the Reheat System removes up to 99% of the condensed moisture from the process air. Figure 3 shows the moisture content of compressed air at various pressure dew points. Moisture is significantly reduced by getting the air as cold as possible. The exact amount of moisture removed depends upon the cooling sources available. Pressure dew point temperatures range from 35 F to 90 F using a Reheat System. D R E H EAT IN. THE A I R Once the air is dried, it needs to be reheated for use in the manufacturing process. Reheating is accomplished using the regenerative heat exchanger as described above, with no external energy source required to heat the air. Instead the "free" heat of compression from the air compressor increases the air temperature well above the pressure dew point at the aftercooler. Process air can be reheated to temperatures ranging from 90 F to 300 F; depending upon the incoming air temperature to the Reheat System. FI6URE 2 TYPICAL ARRANGEMENT OF A REHEAT SYSTEM HOT, WET AIR INLET:" WARM, DRY AIR OUTLET REGENERATIVE HEAT EXCHANGER CYCLONE SEPARATOR 4 TRAP

FIGURE 3 MOISTURE CONTENT OF COMPRESSED AIR > c III A. III... B 0 cn z 0 CD WITHOUT AFTERCOOLER 100 F 90 F 80 F 70 F 50 F 35 F Temperatures above 13rF PRESSURE DEW POINT Based on 1,000 SCFM of air at 100 PSIG operating pressure. Ambient conditions being 84 F, 14.7 PSIA, & 60% Relative Humidity 5

Adams Reheat Systems come in a variety of configurations. The Economat@ Reheat System is used with a single or multiple cooling water source. When a refrigerant is available at the plant, such as ammonia refrigeration in a.rood processing facility, then the AKU Reheat System is recommended. Listed below are further details about each of these systems. Whether making glass, steel, paper, textiles, beer, paint, or a whole range of other products, many manufacturers have come to depend upon the Economat as a reliable and economical source of warm, dry, process air. When the presence of moisture can adversely impact the quality of the end product, the Economat is an important and reliable ally to ensure its removal. The Economat system can be arranged in two typical configurations. One incorporates a single aftercooler, as shown in Figure 4, using one cooling source such as tower, lake, river, city or chilled water. The other, as seen in Figure 5, uses a second aftercooler when another water source is available in the plant. For example, the primary aftercooler uses less expensive tower water to handle part of the cooling; the secondary aftercooler - using chilled water - is responsible for the final cooling. This arrangement reduces chilled water use and the expense associated with it. FIGURE 4 THE ECONOMAT SYSTEM. USING ONE COOLING SOURCE DRY, REHEATED AIR TO YOUR PROCESS HOT, MOIST AIR IN WATER + IN CONDENSATE OUT.. I REGENERATIVE HEAT EXCHANGER FIGURE 5 DRY, REHEATED AIR TO YOUR PROCESS THE ECONOMAT SYSTEM. USING TWO COOLING SOURCES HOT, MOIST AIR IN TOWER + WTER IN CHlUED CONDENSATE OUT.. I I 6 REGENERATIVE HEAT EXCHANGER PRIMARY AFTERCOOLER SECONDARY AFTERCOOLER CYCLONE SEPARATOR

The AKU Reheat System is particularly suited for food processors who have a large refrigeration capacity to keep the food products cold. It takes advantage of the excess refrigerant and uses it as the coolant in the aftercooler. For example, at a major chicken processing facility in North Carolina, nearly all the equipment is pneumatic, and the air must be as dry as possible because the slightest moisture can affect the control systems and shut down processing lines. The AKU Reheat System uses the available ammonia refrigerant to chill the air to a dew point of 35 F; removes the condensed water and then reheats the air. The AKU minimizes refrigerant consumption by pre-cooling the air in the regenerative heat exchanger. After years of trouble-free performance, the operator of the North Carolina chicken plant ordered another AKU system for a similar plant in the Midwest and gave this appraisal of the system's performance: "Not only is it dependable, it's very cost-efficient because it reduces the amount of horsepower needed to cool the air. There are other methods we could use to dry our air, but I don't believe there is another method that would accomplish our goal as inexpensively as the Adams system. As far as maintenance is concerned, we hardly know the AKU is there." IT.S VERY COST-EFFICIENT BECAUSE IT REDUCES THE AMOUNT OF HORSEPOWER NEEDED TO COOL THE AIR... Uses no electrical power for cooling or reheating the air: Conserves coolant needed in the aftercooler because it performs part of the cooling work. Reheats the process air using the heat of compression of the air compressor. [J Restores, by reheating, the energy (air volume) lost during the cooling process. 7

There are a number of critical considerations in the design of a Reheat System. These include the pressure dew point temperature required, final reheated air temperature needed, any requirements for partial, cold air bleed, maximum system pressure drop allowed, and types of coolant available. Every system designed and fabricated by R.P. Adams Company is factory tested before shipment, assuring quality and reliability: In addition, R.P. Adams Company guarantees total system performance for the entire package. ADAMS REHEAT DESIGN QUESTIONNAIRE Type of Quotation: D Budget D Finn Date Quote Required Approx. Installation Date CUSTOMER INFORMATION Contact E-mail Telephone, Fax PROCESS INFORMATION Will all of the air be reheated?................. VALUE SCFM If no, then how much air needs to be reheated? Air inlet temperature into the Reheat System...... Desired pressure dew point.................. Desired air temperature out when reheated....... Air inlet operating pressure................... Total air system pressure drop allowed. COOLING MEDIUM AVAILABLE SCFM, -' " F ':' i of,.1.. PSIG, PSIG - SOURCE 1 SOURCE 2 (IF AVAILABLE) OF Fluid name.............................. Fluid inlet temperature...................... Fluid operating pressure........... DESIGN INFORMATION System Design Temperature.................. Preferred Materials of Construction............. : of : of PSIG. PSIG PSIG of D R. Adams Standard Tubes Shell,." Please photocopy and complete the questionnaire above and fax or mail this information back to us for a proposal. R. P. Adams Company Inc. Quality and innovation for over 60 years Box 963, Buffalo, NY 14240 Phone: 716-877-2608/1-800-896-8869 Fax: 716-877-9385 E-mail: hx@rpadams.com Visit our website at: www.rpadams.com Your Local Representative 10m 11/98 hir/dp