Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Similar documents
LPI Lightning Warning System (LWS) MKIII

LPI Lightning Warning System (LWS) MKIII

LPI Lightning Warning System - LWS MKIII

5000 INSTALLATION GUIDE

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

STEAMPRO. Steam Generator Troubleshooting and Service Guide

STRIKE GUARD DELIVERS:

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

THX-DL Data Logger USER & INSTALLATION MANUAL V

TV2 Room Pressure Monitor Quick Start Guide

Public Safety DAS Annunciator Panel

REPEATER FS5200R INSTRUCTION MANUAL

WAVE SEQUENCER DELIVERS:

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Digital Marine Exhaust Temperature Alarm

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Service Bulletin No. 2930

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

1. Physical Installation 2. In-app Setup 3. Features 4. Troubleshooting 5. Advanced Installation Options

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Carbon Monoxide Transmitter

Model 17A00 Expansion Enclosure

Installation and Use Manual

Added password for IP setup page : Password must be in IP format!

Powerohm Resistors Digital HRG System

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Operation and Maintenance Manual

Across-the-Line SERIES MP300 Combined Manual and Automatic

Installation and Use Manual

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Control Panel User Guide (TO BE RETAINED BY THE USER)

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

INSTALLATION INSTRUCTIONS

1. Quick start-up guide

Watchguard WGAP864 User Manual

GLD-30 Gas Leak Detector

CHECKFIRE 210 Detection and Actuation System

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Architectural and Engineering Specification for a. Flash / Flare

introduction Submittal Data Sheet CENTRA-GUARD POINT LEAK DETECTION

Analog Room Pressure Monitor RPC Series

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

CSP-204 CSP-208 CSP-104 CSP-108

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 410A Gas Monitor Operator s Manual

PTE0705 Electric Fence Monitor

Soft Start Series MP700 Solid State, Reduced Voltage

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Quick Alert Remote (QA216R)

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

EATON DFDAP-M / FDAP-M Remote Alarm Panels

Architectural and Engineering Specification for a Real-Time Locating System Flare

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Installation and Operation Guide EXTERNAL SIREN

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

BodyGuard Proximity Warning System

Gas interlock system S & 100 CS

SYSTEM 5000 USER MANUAL

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Advantium 16 System Monitor

flexibility programmed settings.

IT COULD FAIL TO PERFORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT FOR THEIR SAFETY COULD SUSTAIN SEVERE PERSONAL INJURY OR DEATH.

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

The Challenger Version 8 User Guide

Beacon 800 Gas Monitor Operator s Manual

TV2 Clean Room Monitor

(Cabinet Automatic Fire Extinguishing System)

E25 CONVECTION OVEN E25MS CONVECTION OVEN SERVICE MANUAL

Chargebuster Ion Gun Installation, Operation and Maintenance

EXTINGUISHING AGENT RELEASE MODULE

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Installation and user manual for the BiWire / Conventional Repeater Panel

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

P4200W2 Series Air Dryer

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

Intelligent Security & Fire Ltd

Product Manual. The `Safety Shoe (shown below):

WSK300 Multifunction Wall Control

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

KT-100 Door Controller

AXS Strikemaster Engineering Manual

ECC-1 user manual and installation guide

Troubleshooting Thermo Scientific LevelPRO Gauges

Chargebuster Ion Gun Installation, Operation and Maintenance

Static Pressure Control

1U ULTRA Compact System

Transcription:

User's Guide

CONTENTS FEATURES WHAT YOU NEED TO GET STARTED INSTALLATION DETAILS Installing the Antenna Installing the External Alert Siren The main console OPERATING PROCEDURE Power On Routine Push Buttons Functions Warning Alert Status Alert Alarm Status Event Logging TROUBLESHOOTING TECHNICAL DATA LWS WIRING

FEATURES Lightning Warning System LWS MK-II is a non-directional local warning instrument designed to provide early warning of an approaching storm front that contains lightning discharges. It has been designed to provide protection for personnel and equipments. Early warning of lightning in close proximity allows appropriate safety precautions to be implemented by those involved in a diverse range of activities, mining, construction, quarrying, seismic surveying, oil and gas exploration, oil and gas production, ship loading, where explosives are being used and for those engaged in outdoor recreational activities like golf or soccer. Lightning Warning System is microprocessor controlled which provides concise easily understood alarms; it provides an alarm situation when the internal analysis of prevailing conditions indicates the approach of lightning. The system antenna senses alterations in the electric field strength and also detects both near and far lightning discharges. An alarm is triggered when either the static field changes or when a far or nearby lightning discharge is detected. Two levels of alarm status are provided by the system. WHAT YOU NEED TO GET STARTED Verify that the LWS MK-II package consists of the following components: Main console Antenna assembly with 50m cable Electronic siren with 20m cable RS232 cable for PC based event logging (Software can be downloaded from website) Grounding kit (One (1) 12 x 500mm Ground Rod and One (1) Rod Clamp) AC Power cord Optional Items: Motor SirenS, Relay kits for remote alert with motor siren Siren Assy 9 Pin RS232 cable Control Console Power code Ground Rod Sensing Antenna

INSTALLATION DETAILS Installing the Antenna 1. Survey the intended location of the sensing Antenna. It should be located on a ground level where there is a clear area away from bushes, trees, water towers, antennas, etc. As a guide it should be located at an isolated area at a distance of about twice the height of protruding objects nearby. The sensing antenna must be kept clear of any debris and is placed on a well drained area. The antenna is provided with the grounding kit to provide static earthing; this must be connected to the sensing antenna to ensure correct operation. The sensing antenna has been designed for ground level use and shall provide the best result. However roof top position could be a possible alternative position provided: The roof is very nearly level, The roof is not more than 6m above ground level, The roof is at least twice the width of its height above ground level, and The antenna is positioned near the centre of the roof as possible. DO NOT install the antenna near the edges of the roof. 2. Fix Antenna base unit fixing leg (supplied) to ground. Remove antenna base unit cover by undoing the four fasteners on the front cover. After removal of the antenna base unit cover, carefully remove the antenna lead from the PCB spade connector, (short wire with ring lug attached). Unscrew the bolt from the base of the antenna, a black plastic disc will separate from the body of the antenna once the bolt is unscrewed, remove the plastic disc. Apply gasket grease to the rubber O-ring at the base of the antenna, this ensures a water tight connection (do not use silicon). Place the steel washer and the lug of the antenna lead on to the bolt, thread the bolt through the black plastic disc with the lip on the inside of the disc inserted into the antenna box hole, the black disc should sit flat against the inside of the box with the lip inside the antenna hole, refer Fig 6. Tighten bolt securely. Prior to plugging the antenna lead onto the PCB spade connector, test the resistance between the bolt and earth (metal case) with a multimeter, resistance must be greater than 10 Meg Ohms. Fix the antenna base unit to the square stainless steel section fixing leg using the two countersunk screws provided. The fixing leg is designed to be driven into soft soil, alternatively, it may be concreted in place for a permanent fixture. Mount the antenna box to the base plate (four screws are provided). Attach the needle to the top of the antenna using the small allen key provided. Screw the two antenna sections together, secure with the supplied philips head screw. Replace cover. Note; the lid fits one way only for a water tight fit. Ensure gaskets are seated into lid grooves. Drive ground rod (supplied) to ground. Connect earth cable and secure with the ground rod clamp (supplied).

When installing on a roof, ensure the antenna is securely fixed to a solid point using support type 1 (refer fig 8), which must be ordered as an optional extra. Earthing of the antenna at roof top level should be completed via connection of the grounding cable to the nearest metallic point of the roof. Route pre-assembled shielded cable fitted to the sensing antenna and connect to the "Antenna" terminal of the Main console. Zero setting by the user is not required, as the setting value for the "warning" and "alert" siren are fixed in the software in the processor. SENSING NEEDLE SET SCREW SENSING PART 2 SENSING PART 1 163 SET SCREW SUPPORT TYPE 1 163 SUPPORT TYPE 2 163 SENSING ELECTRONICS ENCLOSURE CABLE 137 163 1,000 GROUNDING ROD 500 SUPPORTING LEG (OPTION)

SUPPORT TYPE 1 SUPPORT TYPE 2 170 185 10mmφ 170 Use anchor bolts ROOF TOP Application recommended SUPPORT TYPE 1 SUPPORT TYPE 2 120 185 120 500 SUPPORTING LEG for Portable Use (OPTION) Ground Level Installation

Installing the External Alert Siren Survey the intended location of external alarm. It should be fitted in a secure area where it cannot be tampered with. The location selected should be able to provide maximum audibility when the external alert alarm is activated. Fix the external alert siren by means of the two mounting holes with secure fasteners. Route external alert siren screened cable provided and connect to Siren 1" terminal on the main console. Where an auxiliary alarm type is used, take off the protective cover and jumper (No.4 and No.8 pin) on "Siren 2" terminal and connect the alarm using 9 pin connector. If it is necessary to disconnect the cable from the alarm to facilitate cable routing, ensure re-connection to be done as per original terminal connections. The Main Console The Main console location shall be located in a secure room occupied by the designated operator. Unpack the Main Console and plug power cord to the main console. Plug power lead to 85 ~ 265V AC power supply. Check sensing antenna has been connected to the main console. Check external alert alarm has been connected to the main console. Activate the Lightning Warning System by switching on the POWER switch. The unit will automatically enter the start up "test procedure". which will then initiate the Test Procedure. See operating procedure of the LWS MK-II below. OPERATING PROCEDURE The LPI Lightning Warning system is controlled by a microcomputer which provides concise easily understood alarms to the user based on its analysis of the prevailing atmospheric conditions. The main console features the following LED display: Electric Field Level Near Strike Far Strike Siren 1 Siren 2 Power On Normal Warning Alert System Fail Battery Backup

Power ON Routine: When the Lightning Warning system is switched on, it initiates an internal diagnostic test, system checks are displayed on an LCD screen and are displayed thus: LPI LWS-MK-II Power 12v OK Power 5v OK Sensor OK Siren 1 OK Siren 2 OK Alert Signal All Clear Signal LED Check System Start Normal, YYYY MM:DD HH:MM Refer to troubleshooting section of this manual if System Fail appears on the LCD screen Push Buttons Functions: Manual TEST : When F1 button on the front panel is depressed it performs a maintenance routine. This initiates the unit to carry out the power-on routine without the actual power off/on switching. Alarm Acknowledged : When F2 button is depressed during operation, the operator can clear the internal buzzer sound "triggered" during Warning or Alert Status Reset : Should the operator feel sure that a warning alert status has been falsely triggered, pressing F3 button will clear the internal buzzer sound and all clear siren is sounded. The LCD display shows ALL CLEAR while the external alarm is sounded until the LCD display shows NORMAL. User setup : Press F1 button and hold 3 seconds to get into User setup mode. Button function at User setup mode Select Scroll Up F1 F2 Escape to pre-stage F3 Menu 1 Pass word Change 1 ( Initial P/W set : 0000 ) User Setup 2 Menu 2 Time set Test time set Siren time Activation time View event Setting the local time Setting the test Siren time (Initial set:1 sec,max.9secs) Setting the actual siren time (Initial set:10 secs,max.999secs) Setting the duration for automatic reset (Initial set:420 secs,max.999secs) Up and DN using F2 button for check events at LCD

Warning Alert Status Is given when the system detects the presence of lightning within a 10-15 kilometer radius or that the electric field strength approaches 4kV/m. The Warning Alert is the first indication that a storm may be approaching and could arrive in the area being monitored in 20-30 minutes. No action need be taken at the Warning Alert stage; this first level of alarm is to alert the user of lightning activity but that it may bypass the monitored area. This first alarm level will trigger an internal buzzer in the console, which may be manually silenced by pressing F2 button, however the Warning LED on the console will remain illuminated. Alert Alarm Status Is given when the system detects lightning discharges within an 8-10 kilometer radius or that the electric field strength has risen to 7kV/m. The Alert Alarm indicates that the storm front is approaching the monitored area and is likely to arrive in 10-15 minutes. In the event of a storm cell forming directly overhead the system will detect this and trigger the Alert Alarm. When the Alert Alarm status is announced it will activate an external alarm (siren) to warn of impending danger. Safety precautions should be implemented when the Alert Alarm is indicated, personnel in the open should proceed to safe area s, detonation circuits in mining, quarrying and construction sites should be isolated to avoid predetonation of explosives, and sensitive electronic equipment not adequately protected by transient protection devices should be disconnected. LED displays will remain illuminated whilst an Alarm condition prevails. An internal timing device is initiated every time the system receives an updated signal that the atmospheric conditions remain above normal. Seven minutes following the last detected Alarm condition the system automatically resets to the NORMAL condition and an ALL CLEAR signal is sounded 3 times for a period of 5 seconds with 2 second intervals.

Event Logging The LWS internally logs events which it records, these can be monitored on the LCD display by using function key or may be downloaded to a personal computer utilizing the LWS-MK-II software, a copy of this software may be downloaded from our website. 1. Copy the file LWS-MK-II.exe (418KB) to your computer, click the program file and the "Lightning event log" window will appear. 2. Click the "connect" button on the menu and then click "download" 3. Type in a file name (e.g, 23/03/04) then save the file. Once the event log is downloaded, the LWS internal system is cleared ready to record the next event. Meaning of event records Warning Far Warning Alert Near Alert : Warning by Far strike : Warning by e-field level : Alert by Near strike : Alert by e-field level TROUBLESHOOTING: Operator must monitor the LCD display and verify the test step when the system failure occurred. LCD display the reason of system fail. Check the unit in accordance to the reason of the system fail shown on LCD display and correct it and restart the unit.

TECHNICAL DATA Description: Lightning Warning System Model: LWS MK-II Control Console Materials: High Quality ABS Case with Front Legs Dimensions: 310mm (w) x 100mm (h) x 260mm (d) Weight: 3.0Kg Console Mode: Micro Processor controlled via RS232 port Operation: Measured electric field strength and detected lightning discharges are used to generate warning and alarm conditions, indicating likelihood of lightning discharge in the monitored area. Extensive external alarm facilities are provided together with self-test capabilities. AC Power Supply: 85 ~ 265v Free voltage, 50-60 Hz Sensing Antenna: Fiberglass, 2 section total height 3 meters Sensing Antenna weight: 6.8 Kg (Including 50m cable) Sensing Modes: Electrostatic Field Meter (0-10Kv/m) & Lightning Discharge Detector - Far Strike >approx. 10Km - Near Strike <approx 10Km Warning / Alert Alarm: Electronic siren Material: ABS, weather proof Weight: 1.8 Kg (Including 20m cable) System Packaging: The system is shipped in heavy-duty reinforced cardboard cartons Dimensions: 1 x x 10 x 10 cm 1 x 55 x 24 x 65 cm Gross Weight: 1 x 3kg 1 x 14kg

LIGHTNING WARNING SYSTEM WIRING 220Vac STD Siren SSR 220Vac AC POWER Main Console TVSS 3c MDF 3c 3c 3c SSR 220Vac 9P RS232 SSR Motor Siren (OPTIONAL) EVENT LOGGING via PC