ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

Similar documents
PURest Air Dryer Installation and Maintenance

Bulletin No.: PRO Effective Date: 7/15/94 Cancels: PRO dated 5/1/92 Page: 1 of 6

Installation Guide L /08. Haldex ModulAir Installation / Service Manual

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

SD Bendix AD-1 and AD-2 Air Dryers

SD Bendix AD-IS EverFlow Assembly BENDIX AD-IS EVERFLOW ASSEMBLY

SD Bendix Dryer Reservoir Module with AD-IS Air Dryer DESCRIPTION

Section 4-3. Service - Air Dryer

SD Bendix AD-IS and AD-IS PuraGuard (Oil Coalescing) Air Dryer and Reservoir Systems

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

Brakemaster air dryers. The complete fleet guide to operation, trouble-shooting, and service procedures

System Saver HP Air Dryer

PuraGuard. Maintenance Kit Rebuild Kit Replacement Drain Cock

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

SD Bendix AD-IP Integral Purge and AD-IP PuraGuard Oil Coalescing Integral Purge Air Dryers

SD Bendix AD-IP Integral Purge Air Dryer DESCRIPTION. The AD-IP air dryer has three female pipe thread air connections identified as follows:

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

Module 7: Air Supply System

TECHNICAL DATA. Wet 26a. February 22, 2009

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

SFD. Suburban Filter Dryer. User Manual Installation Instructions

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Air Dryer Application Guidelines

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Designers Manual. Haldex Single Air Drier

System Saver TWIN Air Dryer. Maintenance Manual 35 Revised 11-02

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

AXPR Wall Mounted Axial Panel Fans

SuperKlean Washdown Products

569, 570, 571, 572 Series

569, 570, 571, 572 Series

WHEELED STORED PRESSURE

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

A COMPLETE GUIDE TO OPERATION, TROUBLESHOOTING AND SERVICE PROCEDURES 2005 DRY AIR SYSTEMS Group (04/05)

USER MANUAL UN-200V / UN-200VH

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

Mopar B-Body Condenser Kit with Drier

PURGE STANDARD IPC AIR DRYER LABEL

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

17 U.S. gallon portable low profile drain with electric pump

10/09/2014. SFD Air Dryer Owner s Manual

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

568X, 587X, 588X Series

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

ACT Cartridge Dust Collector

Audi-Larm Audible Alarm

A B A B4

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Impeller Stack Kit Dismantling and Reassembly CR(I/N) 1S 1 3 5

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

REVISED AIR GOVERNOR LINES CX AND CH MODEL CHASSIS WITH ASET AC ENGINE

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

36"x17" Portable Tool Chest and 6-Drawer Tool Cabinet

HEATING AND AIR CONDITIONING

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

IMAGE V. Parts and Service Manual

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Installation Instructions Part No , Part No Part No

Page 1 of 18. Part# /5/2013

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

CABS/BLADES/ SPREADERS/ACCESSORIES

DEF Metering Unit Inlet Screen Clogging Due to Excessive Moisture in the Air System 42-69

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

Models: GW/R-T GW/R-2-T GW/R-3-T

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

TECHNICAL INSTRUCTIONS

OTO BONDER OWNER S MANUAL WITH CIRCULATING SYSTEM MACHINERY DIVISION - - L to R Unit Shown

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

SuperKlean Washdown Products

HEATING AND VENTILATION

Model OP155 Air Dryer

Chevrolet Pickup Condenser Kit with Drier with Condenser Mounted Forward From Stock Position (021553)

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-022

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

CONSTANT SUCTION UNIT

PRO 2000i LOW LEVEL DEPOSITOR

TECHNICAL INSTRUCTIONS

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Models , Equinox, and Sirens Clutch Replacement Service Manual

BlueHeat AirTop 2000 Heater

Fan Drive Maintenance Training Manual

Advanced Troubleshooting Guide for Air Brake Compressors *

UNIQUE USER FRIENDLY MICROMETER STYLE ADJUSTMENT

Installation Manual PS-200 & PS-201

Service Bulletin Trucks Date Number Page

TECHNICAL INSTRUCTIONS

TROUBLESHOOTING VANGUARD

INSTALLATION & OPERATING INSTRUCTIONS

Transcription:

Instruction Guide L31259 11/10 ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation Air Dryer Mounting Bracket (Item 1) Tank Mounting Bracket (Item 19) Outside of Frame Rail Install Inside of Frame Rail Install DQ6063 Kit Contents Item* Description Qty. 1 Air Dryer Mounting Bracket 1 2 1/2 Lock Washer 3 3 1/2-13 UNC Hex Head Bolt, 1.0 Long 3 4 3/8-16 UNC Hex Head Bolt, 1.25 Long 4 5 3/8-16 UNC Hex Nut 4 6 3/8 Lock Washer 4 7 3/8 Flat Washer 8 8 1/4 NPT to 3/8 Tube Swivel Elbow 3 9 3/8 Tube Elbow 1 10 1/4 NPT to 1/4 Tube 90 Fitting 2 Item* Description Qty. 11 1/2 NPT to 1/2 Tube Fitting - PTC 2 12 Air Reservoir/Purge Tank 1 13 Automatic Drain Valve 1 14 M22 to 3/8 Tube Adapter 1 15 7/16 Flat Washer 2 16 7/16 Lock Washer 2 17 7/16-14 UNC Hex Head Bolt, 1.0 Long 2 18 3/8 O.D. Nylon Tube (36 Long) 1 19 Tank Mounting Bracket 1 20 Instruction Sheet (L31259) 1 * This Item Number will be referenced throughout these instructions.

this page left blank intentionally

ModulAir Port and Part Identification

! Important Precautions When working on air system components the following precautions should be observed. 1. Park the vehicle on a level surface, apply the parking brakes and always block the wheels. 2. Stop the engine when working around the vehicle. 3. Make certain to drain the air pressure from all reservoirs before beginning any work on the vehicle. 4. Following the vehicle manufacturer's recommended procedures; deactivate the electrical system in a manner that removes all electrical power from the vehicle. 5. When working in the engine compartment, the engine should be shut off. Where circumstances require that the engine be in operation, extreme caution should be used to prevent personal injury resulting from contact with moving, rotating, leaking, heated or electrically charged components. 6. Never connect or disconnect a hose or line containing pressure. Never remove a component plug unless you are certain all system pressure has been depleted. 7. Never exceed recommended pressures and always wear safety glasses. 8. Do not attempt to install, remove, disassemble or assemble a component until you have read and thoroughly understand the recommended procedures. Use only the proper tools and observe all precautions pertaining to the use of those tools. 9. Use only genuine Haldex replacement parts, components and kits. Replacement hardware, tubing, fittings, etc. should be of equivalent size, type and strength as original equipment and be designed specifically for such applications and systems. 10. Components with stripped threads or damaged parts should be replaced rather than repaired. Repairs requiring machining or welding should not be attempted unless specifically approved and stated by the vehicle or component manufacturer. 11. Prior to returning the vehicle to service, make certain all components and systems are restored to their proper operating condition. NOTE: This installation is typical for this truck model. Your vehicle may be different, requiring modifications from these instructions. Replacing a Bendix AD-IS with a Haldex ModulAir Air Dryer For Peterbilt Outside of Frame Rail/Inside of Frame Rail Installation Step 1 Photo indicating the dryer location behind the driver s cab entry steps. Outside of Frame Rail Installation. Uses Air Dryer Mounting Bracket (Item 1) which orients the Air Reservoir/Purge Tank (Item 12) horizontally. Inside of Frame Rail Installation. Uses Air Dryer Mounting Bracket (Item 1) and Tank Mounting Bracket (Item 19) which orients the Air Reservoir/Purge Tank (Item 12) vertically. Mark and disconnect existing airlines from the Bendix AD-IS. AIRLINE PORT IDENTIFICATION CHART Port 11 Inlet Port 21 Primary Reservoir Port 22 Secondary Reservoir Port 23 Auxiliary Port 24 Auxiliary Port 4 Control Unloader Outlet Remove air dryer from the vehicle frame rail mounted bracket. Set aside fasteners and air fittings, many of them will be re-used throughout this changeover procedure.

Replacing a Bendix AD-IS with a Haldex ModulAir Air Dryer For Peterbilt Outside of Frame Rail/Inside of Frame Rail Installation (continued) Fig. 1 Fig. 4 Fig. 5 Fig. 2 Fig. 3 Step 2 Step 4 See ModulAir Port and Part Identification Section of this instruction booklet. Install 1/2 NPT to 1/2 tube fitting (Item 11) into Primary Port 21 and Secondary Port 22. Fig. 1 Install 1/4 NPT to 1/4 90 tube fitting (Item 10) into Ports 23 and 24. Orient to correct position. Fig. 2 Install 1/4 NPT to 3/8 swivel tube fitting (Item 8) into purge port fitting on ModulAir. Fig. 3 Plug all unused ports. Fig. 6 Flare Fitting From Bendix AD-IS Fig. 7 Remove pipe plug from Unloader Port of governor on ModulAir and discard. Fig. 6 Install 1/8 NPT to flare fitting removed from Bendix AD-IS dryer. Orient to correct position. Fig. 7 Step 5 Step 3 Fig. 8 Remove heater assembly with 5/32 hex wrench to allow for installation clearance of the Inlet Fitting into Port 11. Fig. 4 Install Inlet Fitting from the Bendix AD-IS inlet port in ModulAir inlet Port 11. Secure inlet port while positioning the fitting. Fig. 5 Re-install heater assembly. Insure heater o-ring is secure in the heater housing upon re-installation. Apply silicon grease to the housing o-ring. Fig. 9 Install ModulAir onto Air Dryer Mounting Bracket (Item 1). Fig. 8 Thread three 1/2-13 UNC Hex Head Bolts-1.0 Long (Item 3) through three 1/2 Lock Washers (Item 2) through the Air Dryer Mounting Bracket (Item 1), into ModulAir threaded mounting holes. Tighten to 55-65 ft-lbs. Fig. 9

Replacing a Bendix AD-IS with a Haldex ModulAir Air Dryer For Peterbilt Outside of Frame Rail/Inside of Frame Rail Installation (continued) Steps 6 through 9 For Outside of Frame Rail Installation Fig. 10 Step 6 Install ModulAir /Bracket Assembly to truck frame mounted bracket. Thread four 3/8-16 Hex Head Bolts (Item 4) through the brackets and secure with four 3/8 Flat Washers (Item 7), through four 3/8 Lock Washers (Item 6) and four 3/8-16 Hex Nuts (Item 5). Tighten to 50-60 ft-lbs. Fig. 11 Fig. 12 Step 7 NOTE: Before installation lubricate the o-ring on both the Automatic Drain Valve (Item 13) and M22 to 3/8 Tube Adapter (Item 14). Avoid the use of thread sealant. Install Automatic Drain Valve (Item 13) into side port of Air Reservoir/Purge Tank (Item 12). Tighten to 55 ft-lbs. Fig. 10 Install M22 to 3/8 Tube Adapter (Item 14) into end port of Air Reservoir/Purge Tank (Item 12). Tighten to 55 ft-lbs. Fig. 11 Then install 3/8 Tube Elbow (Item 9) into M22 to 3/8 Tube Adapter (Item 14). Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Step 8 With the Automatic Drain Valve (Item 13) pointing toward the ground, install Air Reservoir/Purge Tank (Item 22) onto Air Dryer Mounting Bracket (Item 1). Fig. 13 Thread two 7/16-14 UNC Hex Head Bolts-1.0 Long (Item 17) through two 7/16 Lock Washers (Item 16) and two 7/16 Flat Washers (Item 15) into threaded reservoir mounting holes. Tighten to 44-55 ft-lbs. Fig. 14 Step 9 Install one end of the 3/8 O.D. Nylon Tube-36 Long (Item 18) into the 3/8 Tube Elbow (Item 9) located on the Air Reservoir/Purge Tank (Item 12). Fig. 15 Cut to length and install the opposite end of the 3/8 O.D. Nylon Tube (Item 18) into the 1/4 NPT to 3/8 Tube Swivel Elbow (Item 8). Fig. 16 Secure nylon tubing from chafing (rubbing on frame or bracket). Proceed to Step 10 on Page 8.

Replacing a Bendix AD-IS with a Haldex ModulAir Air Dryer For Peterbilt Outside of Frame Rail/Inside of Frame Rail Installation (continued) Steps 6 through 9 For Inside of Frame Rail Installation Fig. 10 Step 6 Mount the Air Reservoir/Purge Tank (Item 12) to the Tank Mounting Bracket (Item 19). Thread two 7/16-14 UNC Hex Head Bolts-1.0 Long through two 7/16 Lock Washers (Item 16) and two 7/16 Flat Washers (Item 15) into threaded reservoir mounting holes. Tighten to 44-55 ft-lbs. Fig. 11 Fig. 12 Step 7 NOTE: Before installation lubricate the o-ring on both the Automatic Drain Valve (Item 13) and M22 to 3/8 Tube Adapter (Item 14). Avoid the use of thread sealant. Install Automatic Drain Valve (Item 13) into end port of Air Reservoir/Purge Tank (Item 12). Tighten to 55 ft-lbs. Fig. 10 Install M22 to 3/8 Tube Adapter (Item 14) into side port of Air Reservoir/Purge Tank (Item 12). Tighten to 55 ft-lbs. Fig. 11 Then install 3/8 Tube Elbow (Item 9) into M22 to 3/8 Tube Adapter (Item 14). Fig. 12 Step 8 With the Automatic Drain Valve (Item 13) pointing toward the ground, install ModulAir Air Dryer Mounting Bracket Assembly and Air Reservoir/Purge Tank Assembly to truck frame mounted bracket. Thread four 3/8-16 UNC Hex Head bolts-1.25 Long (Item 4) through four 3/8 Flat Washers (Item 7) and secure brackets using four 3/8 Flat Washers (Item 7) through four 3/8 Lock Washers (Item 6) into four 3/8-16 UNC Hex Nuts (Item 5). Tighten to 50-60 ft-lbs. Step 9 Install one end of the 3/8 O.D. Nylon Tube-36 Long (Item 18) into the 3/8 Tube Elbow (Item 9) located on the side port of the Air Reservoir/Purge Tank (Item 12). Cut to length and install the opposite end of the 3/8 O.D. Nylon Tube (Item 18) into the 1/4 NPT to 3/8 Tube Swivel Elbow (Item 8). Secure nylon tubing from chafing (rubbing on frame or bracket). Proceed to Step 10 on Page 8.

Replacing a Bendix AD-IS with a Haldex ModulAir Air Dryer For Peterbilt Outside of Frame Rail/Inside of Frame Rail Installation (continued) Step 10 Re-attach airlines using the AIRLINE PORT IDENTIFICATION CHART in STEP 1. Re-attach the heater connection. Position airlines to prevent water traps and airline chafing (rubbing on frame or bracket). Step 11 Installation is complete. Air up the system, check for purge of ModulAir and air leaks with the instructions shown in the Testing the Haldex ModulAir Air Dryer section of this instruction guide.

Testing the Haldex ModulAir Air Dryer Before placing the vehicle in service, perform the following tests. 1. Close all reservoir drain cocks. 2. Start vehicle and build up the air pressure to governor cut-out and note that the air dryer purges with an audible exhaust of air. Air should continue to flow from the dryer exhaust for approximately 20-30 seconds as the dryer regenerates the desiccant. The Reservoir/Purge Tank pressure will decrease to zero psi while the dryer regenerates the desiccant. 3. Actuate the service brakes to reduce system air pressure to governor cut-in. Note that the system once again builds to full pressure and is followed by a purge. See Troubleshooting and Service Kit Information on the following pages. 4. Perform standard air leakage tests to assure the air dryer will not cycle excessively. 5. Charge Cycle Time: During normal, daily operation the compressor should recover from governor cut-in to governor cut-out in 90 seconds or less depending upon engine speed and vehicle vocation. An excessive recovery time may indicate the air compressor performance has decreased and should be investigated. 6. Purge Cycle Time: During normal vehicle operation, the air compressor must remain unloaded for a minimum of 30 seconds between charge cycles. This minimum purge time is required to insure complete regeneration of the cartridge desiccant.

ModulAir Air Dryer Troubleshooting Problem Cause Solution Water in air system 1. Desiccant contaminated 1. Replace desiccant cartridge. Wipe dryer base clean. Check (oil) or over saturated. compressor for excessive oil passage. 2. Leaks in air system. 2. Tighten air connections. Use soapy water to recheck for leaks following the Testing The ModulAir Dryer Section. 3. Governor loose or not 3. Check governor gasket for damage and replace if necessary. functioning properly. Reassemble governor and tighten governor bolts to recommended manufacturer s torque specifications. Constant exhaust of air 1. Dryer unloader valve not 1. At compressor cut-out there must be a slight blow of at air dryer closing. regenerated air from the exhaust port of the dryer for approx. 20-30 seconds. If air flow continues, after purge cycle, remove and inspect unloader valve of the dryer for obstruction or damage. If damaged, then replace. If obstructed or dirty, then clean and reinstall. 2. Governor loose or not 2. Check governor gasket for damage and replace it if necessary. functioning properly. Reassemble governor and tighten governor bolts to recommended manufacturer s torque specifications 110-150 lb. in. 3. Compressor unloader not 3. Repair or replace compressor unloader. functioning (compressor not unloading). Excessive Compressor 1. Excessive leaks in air system. 1. Tighten air connections, soap connection and recheck for Cycling air leaks. 2. Broken, contaminated or 2. Clean or replace compressor unloader valve. defective unloader valve. 3. Undersized compressor, 3. Reduce air demand or use a compressor with greater air duty cycle of compressor output. should not exceed 25%. Safety Valve Is Open 1. Desiccant cartridge is plugged 1. Excessive oil passage from compressor or high amount of or overly contaminated. carbon buildup. Check for worn compressor (piston rings, gaskets, etc.) Replace desiccant cartridge. 2. Ice blockage inside air dryer. 2. Check heater for proper functioning. 3. Excessive system pressure. 3. Repair or replace governor. Short Life Of Dryer Or 1. Air at inlet of air dryer exceeds 1. Extend length of compressor discharge line; see Installing Desiccant Cartridge 170 F (77 C). the ModulAir Section. The 170 F (77 C) air dryer inlet temperature can usually be achieved with 12 to 15 of compressor discharge line. Short Purge Cycle Of Air 1. Loose governor or poor 1. Tighten governor bolts. If leakage still occurs, then replace Dryer (Less Than 12 gasket seal. gasket or complete governor. Seconds) 2. Regeneration valve not 2. Replace regeneration valve. functioning.

ModulAir Air Dryer Service Kit Information The following kits are available for service and maintenance of the ModulAir Air Dryer. Each service kit includes installation instructions. 3 1. Desiccant Cartridge Part No. 47178964 2. O-Ring for Cartridge Part No. DQ6054 3. Retaining Collar Part No. 47171868 4. Governor Kit Part No. KN18541 5. Turbo Protection Valve Part No. DQ6055 6. Heater Assembly Part No. 47110020 (12VDC) Part No. 47110021 (24VDC) 7. Unloader Valve Part No. DQ6056 4 5 6 1 2 7

Haldex Brake Products Corporation 10930 North Pomona Avenue Kansas City, MO 64153 Phone: 816-891-2470 Fax: 816-891-9447 Commercial Vehicle Systems www.haldex.com L31259 US 11/10 ART ONLY Haldex Limited/Haldex Limitée 500 Pinebush Road, Unit 1 Cambridge, ON Canada N1T 0A5 Phone: 519-621-6722 Fax: 519-621-3924