User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Similar documents
User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CB50

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Baxi Maxflow Combi FS

Alpha FlowSmart 25 and 50

Alpha CombiMax 350 and 600

Baxi Maxflow Combi WM

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Installation and Servicing Instructions

Installation and Servicing Instructions. Alpha CD24C/32C

iheat 25c iheat 30c iheat 35c

USERS GUIDE 24, 30. For installation guide see reverse of book

Alpha CD13R,18R and 24R

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER GUIDE VOGUE MAX SYSTEM

Installation and Servicing Instructions. Alpha GasSaver GS-1

MURELLE EV HE 25/55-30/55

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

24CDi, 28CDi & 35CDi II COMBI

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Installation and Servicing Instructions. Alpha GasSaver GS-2

Installation and Servicing Instructions. Alpha CD50

Logic+ Combi

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USER GUIDE LOGIC HEAT H

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Combi Eco Elite Range. User s Guide and Important Warranty Information

Installation and Servicing Instructions. Alpha CB50

GB24 & GB30. User Manual

Open Vented Condensing Boilers

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Installation and Servicing Instructions. Alpha CD25X/28X

Vote for your Installer of the year at HEATSLAVE

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Installation and Servicing Instructions. Alpha CD25C/28C/35C

2 Minimiser SE - User's

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Greenstar 12i/24i System

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

The guarantee on this appliance is valid for 12 months from the first day of installation.

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

Installation and Servicing Instructions. Alpha FlowSmart

Osprey 2 CFL

Greenstar 12i system / 24i system

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

Mikrofill Ethos Condensing combination boiler

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

E-COMBI EVO E-SYSTEM EVO

kw Btu/h Metres Feet l/min. Gal/min C C

GREENSTAR HIGHFLOW 440/550CDi

Greenstar 24i junior / 28i junior

Bosch Group. 24i RSF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

MODEL 466 Radiant / Convector Gas Fire Black Beauty

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

Installation and Servicing Instructions. Alpha SolarSmart 90

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

FEB-24E UK SUPERCOMPACT COMBINATION BOILER USER MANUAL

User Guide. Gold Combi Condensing Combination Boiler

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Operating instructions

DOMESTIC HOT WATER Follow operational sequence

Bosch Group. 24CDi OF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Alpha SolarSmart 100

GREENSTAR HIGHFLOW 440/550CDi

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia


Operating instructions

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Transcription:

User's Instructions Alpha CD5X/8X Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel: 0844 878764 website: www.alpha-innovation.co.uk Nepicar House, London Road, Wrotham Heath, Sevenoaks, Kent TN5 7RS British Gas Service Listed 005 Alpha CD5X G.C. No. 47 5 9 Alpha CD8X G.C. No. 47 5 7 For use with Natural Gas only Leave these instructions with the User

DESCRIPTION The Alpha CD range of high efficiency condensing combination boilers are wall mounted, fan assisted room-sealed boilers. The CD5X and CD8X are combination boilers providing both central heating and domestic hot water at mains pressure. The CD5X boiler is suitable for central heating loads of between 4.5 and 9.5 kw (5 50 and 66 50 Btu/h). The CD8X boiler is suitable for central heating loads of between 4.9 and 5.8 kw (6 70 and 88 00 Btu/h). The boilers will provide central heating (as required) during the 'on' times set on your clock (if fitted). Hot water is always available from the boilers whenever a hot tap is opened and takes priority over the central heating. The burner is lit electronically. USER CONTROLS Pull the controls panel cover forward and down to gain access to the controls. Clock (if fitted) Indicator Neons Selector Switch Domestic Hot Water Thermostat Central Heating Thermostat System Pressure Gauge OFF A B C D 0 RESET 9 9 8 4 8 4 7 5 7 5 6 6 SELECTOR THERMOSTAT THERMOSTAT 0 4 bar Fig. BOILER CONTROLS. CENTRAL HEATING THERMOSTAT This thermostat controls the temperature of the water leaving the boiler for the heating system. For maximum efficiency from the boiler the thermostat should be left at number 6 as shown in Fig.. If lower heating temperatures are required, turn the thermostat ant-clockwise. If higher temperatures are required, turn the thermostat clockwise.. DOMESTIC HOT WATER THERMOSTAT This thermostat controls the temperature of the domestic hot water leaving the boiler. For maximum hot water temperatures the thermostat should be left at maximum i.e. fully clockwise. If lower temperatures are required, turn the thermostat anticlockwise.. SELECTOR SWITCH This control allows the boiler to provide central heating and hot water or hot water only. Note: The internal clock and frost thermostat will not operate when the switch is in the vertical position, i.e. 'Off' position (0). 4. PRESSURE GAUGE This indicates the central heating system pressure. It should always be within the green band when cold, increasing slightly when hot. If the pressure falls below the green band, i.e. lower red area, refer to the label on the inside of the hinged control panel cover for guidance on re-pressurising the system. Or contact your Installer to have the system checked and pressurised. Alpha CD5X/8X

5. INDICATOR NEONS When neons A (red), B (red), C (yellow), D (green) are illuminated, the following conditions apply:- Neon D Illuminated continuously - Electricity supply to the boiler is on. C Illuminated continuously - Burner is alight. A Flashing on and off - Temperature sensor fault, contact your Service Engineer. B Flashing on and off - Overheat thermostat has operated. Rotate selector switch to the reset position () to reset. If this continues to happen, contact yor Service Engineer. B Illuminated continuously - Burner has failed to light. Rotate selector switch to the reset position () and the ignition sequence will restart after a delay of about 0 seconds. A and B Flashing on and off at the same time - Blocked flue or fan fault, contact your Service Engineer. A and B Flashing on and off alternatively - System pressure is very low and re-pressurisation is required. A Flashing and B Illuminated continuously - Pump fault or restricted flow. Note: Do not hold the selector switch in the reset position () for more than or seconds. 6. OVERHEAT THERMOSTAT This thermostat automatically switches the boiler off in the unlikely event of the boiler overheating. When the thermostat operates, the red neon (B) flashes on and off. Rotate the selector switch to the reset position () and the boiler will relight. If this continually happens, contact your Service Engineer. 7. PRESSURE RELIEF VALVE If the central heating system overheats and steam or water is discharged from the pipe connected to this valve, turn the boiler off and contact your Service Engineer. Your Installer should have shown you where this pipe terminates, usually outside your dwelling. 8. FROST THERMOSTAT The boiler has a built-in frost thermostat, which automatically operates the boiler if the water temperature inside the boiler falls below 4 C, providing the electrical supply is on and the selector switch is set to position () or position (). Additional frost protection to pipework external to the boiler may be required. 4 LIGHTING INSTRUCTIONS Refer to Fig. for boiler controls.. Ensure the following:- a. Electrical supply to the boiler is off. b. All heating controls and thermostats are set to OFF or minimum position. c. All isolation valves at the bottom of the boiler are in the open position (slot on the spindle in line with the valves i.e. ). d. The gas and water supplies are on at the mains. e. The heating system pressure is within the green band as shown by the pressure gauge.. Switch on the electrical supply to the boiler.. Set any room thermostats to maximum and ensure that any clock is in an 'on' position. Refer to section 8, if a clock is fitted in the boiler control panel. 4. Set the selector switch to (hot water only). 5. Turn the hot water thermostat fully clockwise. Open a hot water tap, the main burner will light and the boiler will provide hot water. Close the tap and the burner will go out. 6. Set the selector switch to position () and turn the heating thermostat fully clockwise. The main burner will light and the boiler will provide central heating. 7. Set the boiler thermostats, clock, external controls i.e. room thermostat to your chosen settings and the boiler is ready to operate. To turn the central heating off i.e. in Summer:- Set the selector switch to position (). To turn the boiler off for short periods:- Set the selector switch to position (). Note: In this position the pump will automatically operate for 5 minutes in every 4 hours. If the water temperature falls below 4 C inside the boiler the built-in frost thermostat will operate the boiler automatically until the temperature of the water in the heating system has been raised. To turn the boiler off for longer periods:- Switch off the electrical supply to the boiler. If required, all supplies i.e. gas, water and electricity may be turned off at the mains. If there is any possibility of the boiler being left during frost conditions, then the boiler and system should be drained and a label attached to the boiler drawing attention that the system has been drained. If this is required, contact your Service Engineer. Alpha CD5X/8X

5 BOILER OPERATION The operating sequence of the boiler is controlled by the selector switch on the control panel. With the switch set to (hot water only) the boiler will only operate to provide domestic hot water, ideal for Summer use when central heating is not required. Setting the selector switch to position () the boiler will operate to provide central heating and hot water. If the boiler is operating to provide central heating and a hot water tap is opened, the boiler will automatically switch over to provide hot water. Such an interruption in the central heating should not generally be noticed by any reduction in room temperature. If a clock is fitted to the boiler, it will only control the operating times of the central heating. Hot water will always be available when a tap is opened. When the selector is set to central heating and hot water, it will respond to a demand for heat in the following sequence:- a. The pump will start, the fan will operate and the main burner will light. b. The output of the burner is automatically controlled to suit the system demand. c. When the temperature of the system water in the boiler reaches that set by the thermostat or the room thermostat is satisfied, the main burner is turned off and the fan stops after 50 seconds. The pump will continue to run for three minutes. d. When a hot tap is opened, the boiler automatically senses a flow of water. The pump will start, the fan will operate and the main burner will light. e. The boiler will continue to supply hot water at the temperature set by the thermostat until the tap is closed. 6 HOT WATER USE The supply of hot water is almost instantaneous at the boiler, but the time taken to reach a tap and the temperature at which it leaves the tap will depend on the rate at which the water is drawn off and the length of the pipe between the tap and the boiler. Fully opening a hot tap may not always provide the maximum temperature as the flow rate may be too high, try closing it slightly until the maximum temperature is achieved. Depending on your mains water pressure, it may not be possible to operate several hot taps at the same time. 7 USING A SHOWER Thermostatic or pressure equalising type - When using these types of shower set the boiler domestic hot water thermostat to maximum. The shower should then maintain a relatively constant temperature. Manual bath mixer type shower - When using this type of shower set the boiler domestic hot water thermostat to setting 7, This should avoid excessive temperatures at the shower. Note: If you get unacceptable temperature variations with this type of shower, then a thermostatic or pressure equalising type should be used. 4 Alpha CD5X/8X

8 IMPORTANT NOTES. BOILER LOCATION Always ensure the following clearances are available around the casing of the boiler:- Top: 5 mm, Bottom: 50 mm, Each side: 5 mm, Front: 450 mm Do not store any other articles in the cupboard containing the boiler and never place any clothing or combustible material on or near the boiler or flue pipe.. FLUE TERMINAL The terminal on the outside wall must not be allowed to be obstructed. If it is damaged, in any way, turn the boiler off and contact your Service Engineer. Note: The Alpha CD boilers are high efficiency condensing boilers and when operating vapour will be emitted from the terminal. This is safe and quite normal.. MAINS FAILURE In the event of an electrical supply failure the boiler will not operate. When the supply is restored, the boiler will return to normal operation. Remember to reset the clock, if fitted, when the supply is restored. If the mains water supply fails, there will be no hot water from the taps. The boiler will continue to provide central heating. 4. ADDITIONAL BATHROOM FITTINGS Any equipment such as mixing valves, showers, bidets etc. must be designed to operate at mains water pressure. Contact your plumbing merchant or installer for advice when considering purchasing such items. 5. CLEANING Use only a damp cloth and mild detergent to clean the boiler outer casing. Do not use abrasive cleaners. 6. SERVICING To maintain efficient and safe operation of your boiler, routine annual servicing is essential. For advice on servicing contact:- The Alpha Helpline: 0844 878764. 7. GAS LEAK If a fault or gas leak is suspected, turn off the gas supply. Do not touch any electrical switches, do not smoke and extinguish all naked flames. Contact your local Gas Region immediately. 8. ELECTRICAL SUPPLY The boiler requires a 0/40 V ~ 50 Hz supply, fused at A if a A -pin plug is used or a 5 A fuse if any other type of plug is used. To connect a plug:- The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the terminals in your plug. In this case proceed as follows:- The wire coloured green and yellow must be connected to the terminal in the plug that is marked with the letter E, or by the earth symbol, or coloured green or green and yellow. The blue wire must be connected to the terminal which is marked with either the letter N or coloured black. The brown wire must be connected to the terminal which is marked with the letter L or coloured red. THE APPLIANCE MUST BE EARTHED. Alpha CD5X/8X 5

9 GAS SAFETY REGULATIONS Current Gas Safety (Installation and Use) Regulations:- It is the law that all gas appliances are installed and serviced by a competent person, i.e. Gas Safe registered personnel. Failure to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance with the law. The manufacturer's instructions must not be taken in any way as over-riding statutory obligations. The Benchmark Checklist must be fully completed by the installer on installation of the boiler. The Benchmark Checklist is shown in Section of the Installation and Servicing instructions. All Gas Safe registered installers carry a Gas Safe ID card and have a registration number. Both should be recorded in the Checklist. You can check your installer is Gas Safe registered by calling Gas Safe on 0800 4085500. 0 CLOCK (if fitted) The clock allows you to set the times at which the boiler will operate to provide central heating. It does not affect the supply of domestic hot water, which is always available whatever the setting of the clock.. TO SET THE TIME Turn the outer dial clockwise to set the clock hands to the correct time. (Ensure the time indicator corresponds with the correct time on the 4hr dial as shown in Fig., e.g..00pm = 5 not ). NOTE: Do not rotate the dial anti-clockwise. TO SET THE ON/OFF PERIODS Select the ON times by pushing the tappets out. Select the OFF times by pushing the tappets in. Fig. shows the clock set as follows:- ON.00pm to 0.00pm (5 - ) OFF 0.00pm to 5.00am ( - 5) ON 5.00am to 8.00am (5-8) OFF 8.00am to.00pm (8-5). MANUAL SWITCH The clock has a manual On/Off switch which operates as follows:- Mid position Heating On/Off as set by the tappets Position I (right) Heating On continuously Position 0 (left) Heating Off continuously Fig. 6 Alpha CD5X/8X

FAULT FINDING FOR THE USER If you experience a problem of no heating and, if applicable, no hot water, try to solve the problem by following the simple checks below before calling out a service engineer. Pull the controls panel cover forward and down to gain access to the controls. Clock (if fitted) If any of these lights are on or flashing, rotate the selector switch to RESET (position ) See D Is needle within or above the green band? If not - See A Turn selector to (position ) Turn to maximum A B C D OFF 0 RESET 9 9 8 4 8 4 7 5 7 5 6 6 SELECTOR THERMOSTAT THERMOSTAT 0 4 bar If this light is not on See B Then turn selector to (position ) This light should illuminate If not - See C Open a hot tap fully and this light should illuminate If no hot water - See E A B C D E - Refer to the label on the inside of the hinged cover for guidance on repressurising the system. Or contact your installer. Or - Check that the electrical supply to the boiler is on. If so - Check that all controls are calling for heat, i.e. room thermostat, clock. If so - Check that the gas supply is on. If the light continues to come on after resetting - Contact the Alpha Helpline Ring the Alpha Helpline Service Tel: 0844 878764 You will be asked the Serial No. of your boiler when you ring. The Serial No. of the boiler is on the inside of the hinged cover. Alpha CD5X/8X 7

Alpha Therm Limited. Nepicar House, London Road, Wrotham Heath, Sevenoaks, Kent TN5 7RS Tel: 0844 878764 These instructions have been carefully prepared but we reserve the right to alter the specification at any time in the interest of product improvement. Alpha Therm Limited 0. email: info@alpha-innovation.co.uk website: www.alpha-innovation.co.uk Leaflet compiled and designed by Publications 000 - Tel: 0670 56 Part No..0480 0//D6