Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Similar documents
Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Sprinkler Identification Numbers

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Submittal Packages Detailed with Items and Reviewers

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Sprinkler Identification Numbers

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Sprinkler Identification Number (SIN)

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Model/Sprinkler Identification Numbers

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Sprinkler Identification Numbers

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Worldwide Contacts.

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

The Series LFII (TY3596) Residential

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Automatic Sprinklers

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Automatic Sprinklers

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

11.2K * Pendent Extended Coverage, Light and Ordinary Hazard General Description. Model/Sprinkler Identification Numbers (SINs) Technical Data

Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K-factor General Description

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K-factor General Description

Models BB, SD, HIP, and AP Specific Application Sprinklers For Protecting Attics General Description

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Design Criteria. Installation

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe and Dry Pipe Systems

STORAGE FIRE PROTECTION SPRINKLERS

Model/Sprinkler Identification Number (SIN) Technical Data

Full-scale tested, for use in wood truss construction. Listed for specific roof slopes from 4:12 to 12:12.

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Transcription:

Worldwide Contacts www.tyco-fire.com Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description The Model TY-FRFS, TY-FS Special, and TY-FS, Upright and Pendent, Flat Spray Sprinklers are intended for installation in accordance with CEA 4001 Sprinkler Systems Planning and Installation or EN12845 Automatic Sprinkler Systems Design, Installation and Maintenance, as applicable. They produce a flatter spray pattern than standard spray sprinklers, enabling them to be used with lower clearance above the suspended open ceilings and in racks. As necessary the K80 and K115, Flat Spray Sprinklers may be outfitted with guards, shields, or guards with shields. The guards may be used in areas that make the sprinklers susceptible to mechanical or physical damage, whereas the shields may be used to help prevent the sprinklers from being wetted (cold soldered) from water spray of higher elevation sprinklers. Table A provides a detailed matrix of the allowable combinations. The Model TY-FRFS with its 3 mm diameter heat sensitive bulb element is rated quick response, the Model TYFS Special with its 4 mm diameter heatsensitive bulb element is rated special response, and the Model TY-FS with its 5 mm diameter heat sensitive bulb element is rated standard response A. IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. CEA 4001 Sprinkler Systems Planning and Installation and EN12845 Automatic Sprinkler Systems Design, Installation and Maintenance permits flat spray sprinklers to be used in concealed spaces, suspended open ceilings, and in racks. NOTICE Model TY-FRFS, TY-FS Special, and TY-FS Sprinklers, as well as guard/ shield accessories, described herein must be installed and maintained in compliance with this document,as well as with the applicable standards recognized by the approval agency, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. Sprinkler Identification Numbers (s) Model TY-FRFS (3 mm Bulb) TY1136 Upright K57 TY1236 Pendant K57 TY3136 Upright K80 TY3236 Pendent K80 TY4136 Upright K115 TY4236 Pendent K115 Model TY-FS Special (4 mm Bulb) TY1146 Upright K57 TY1246 Pendent K57 TY3146 Upright K80 TY3246 Pendent K80 TY4146 Upright K115 TY4246 Pendent K115 Model TY-FS (5 mm Bulb) TY1156 Upright K57 TY1256 Pendent K57 TY3156 Upright K80 TY3256 Pendent K80 TY4156 Upright K115 TY4256 Pendent K115 Model TY-FRFS Model TY-FS Special Model TY-FS Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Page 1 of 8 OCTOBER 2015 TFP635

Page 2 of 8 Series Bulb Size Orifice Position Approvals Guard Shield Guard/Shield TY-FRFS 3 mm TY1136 LPCB, VdS N/A N/A N/A TY-FS Special 4 mm Upright TY1146 VdS N/A N/A N/A TY-FS 5 mm TY1156 LPCB, VdS N/A N/A N/A K57, 10 mm TY-FRFS 3 mm TY1236 LPCB, VdS N/A N/A N/A TY-FS Special 4 mm Pendent TY1246 VdS N/A N/A N/A TY-FS 5 mm TY1256 LPCB, VdS N/A N/A N/A TY-FRFS 3 mm TY3136 LPCB, VdS G1 N/A N/A TY-FS Special 4 mm Upright TY3146 VdS G1 N/A N/A TY-FS 5 mm TY3156 LPCB, VdS G1 N/A N/A K80, 15 mm TY-FRFS 3 mm TY3236 LPCB, VdS G1 H1 or H2 G1/H1 or G1/H2 TY-FS Special 4 mm Pendent TY3246 VdS G1 H1 or H2 G1/H1 or G1/H2 TY-FS 5 mm TY3256 LPCB, VdS G1 H1 or H2 G1/H1 or G1/H2 TY-FRFS 3 mm TY4136 LPCB, VdS G1 N/A N/A TY-FS Special 4 mm Upright TY4146 VdS G1 N/A N/A TY-FS 5 mm TY4156 LPCB, VdS G1 N/A N/A K115, 20 mm TY-FRFS 3 mm TY4236 LPCB, VdS G1 H1 or H2 G1/H1 or G1/H2 TY-FS Special 4 mm Pendent TY4246 VdS G1 H1 or H2 G1/H1 or G1/H2 TY-FS 5 mm TY4256 LPCB, VdS G1 H1 or H2 G1/H1 or G1/H2 TABLE A ALLOWABLE COMBINATIONS OF S, S, AND S WITH S Technical Data Approvals VdS Approved for installation per CEA 4001 Sprinkler Systems Planning and Installation or EN12845 Automatic Sprinkler Systems Design, Installation, and Maintenance LPCB Approved (Refer to Table A) The Guards, Shields, and Guards with Shields are VdS Approved with the combinations of product shown in Table A For details contact: Tyco Fire & Building Products Enschede, Netherlands Tel. 31-53-428-4444 Fax 31-53-428-3377 Maximum Working Pressure 12,1 bar Discharge Coefficient K=57 lpm/bar 1/2 K=80 lpm/bar 1/2 K=115 lpm/bar 1/2 Temperature Ratings ( C) 57, 68, 79, 93, and 141 Finishes Sprinklers: Natural Brass Guards: Red Painted / Zinc Chromate Shields: Zinc Chromate Physical Characteristics Frame............................Bronze Button...Bronze/Copper Sealing Assembly..Beryllium Nickel w/teflon Bulb............................... Glass Compression Screw.................Bronze Deflector......................... Copper Guard...Welded Carbon Steel Shield.......................Carbon Steel Shield Spring..................Carbon Steel Design Criteria The Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers are only intended for installation per CEA 4001 Sprinkler Systems Planning and Installation or EN12845 Automatic Sprinkler Systems Design, Installation and Maintenance where flat spray sprinklers are permitted. Note: In all cases, CEA 4001 Sprinkler Systems Planning and Installation or EN12845 Automatic Sprinkler Systems Design, Installation and Maintenance must be referenced and followed to ensure an effective installation. The Flat-Spray Sprinklers have significantly different water distribution characteristics from that of conventional and spray pattern sprinklers that has enabled the Flat-Spray Sprinklers to be used in conformance with CEA 4001 Sprinkler Systems Planning and Installation or EN12845 Automatic Sprinkler Systems Design, Installation and Maintenance.

Page 3 of 8 MODEL BULB SIZE TY-FRFS 3 mm TY1136 TY1236 TY-FS SPECIAL 4 mm TY1146 TY1246 TY-FS 5 mm TY1156 TY1256 Components: 1 - Deflector 2 - Compression Screw 3 - Bulb (See table above) 4 - Button 5 - Sealing Assembly 6 - Frame 1 2 3 4 5 6 Temperature rating is indicated on Deflector or adjacent to orifice seat on frame. 10 mm DEFLECTOR 55 mm 10 mm WRENCH FLATS ISO 7-R 3/8 CROSS SECTION FIGURE 1 57 K-FACTOR, 10 MM ORIFICE, ISO 7-R 3/8 THREAD AND S ISO 7-R 3/8 55 mm 40 mm DEFLECTOR MODEL BULB SIZE TY-FRFS 3 mm TY3136 TY3236 TY-FS SPECIAL 4 mm TY3146 TY3246 TY-FS 5 mm TY3156 TY3256 Components: 1 - Deflector 2 - Compression Screw 3 - Bulb (See table above) 4 - Button 5 - Sealing Assembly 6 - Frame 1 2 3 Temperature rating is indicated on Deflector or adjacent to orifice seat on frame. 11 mm DEFLECTOR 11 mm WRENCH FLATS 4 57 mm 5 THREAD RELIEF 6 1/2" NPT CROSS SECTION FIGURE 2 80 K-FACTOR, 15 MM ORIFICE, 1/2 INCH NPT THREAD AND S Pipe thread connections per ISO 7-1 can be provided on special request. 1/2" NPT AND ESCUTCHEON PLATE 40 mm 57 mm DEFLECTOR MODEL TY-FRFS BULB SIZE 3 mm Components: 1 - Deflector 2 - Compression Screw 3 - Bulb (See table above) 4 - Button 5 - Sealing Assembly 6 - Frame TY4136 TY-FS SPECIAL 4 mm TY4146 TY-FS 5 mm TY4156 1 2 3 TY4236 TY4246 TY4256 Temperature rating is indicated on Deflector or adjacent to orifice seat on frame. 13 mm DEFLECTOR 13 mm WRENCH FLATS Pipe thread connections per ISO 7-1 can be provided on special request. 3/4" NPT AND ESCUTCHEON PLATE 60 mm 46 mm 4 5 60 mm THREAD RELIEF 6 3/4" NPT DEFLECTOR CROSS SECTION FIGURE 3 115 K-FACTOR, 20 MM ORIFICE, 3/4 INCH NPT THREAD AND S

Page 4 of 8 73 mm DIA. 15 or 20 mm or THREAD RELIEF ENGAGED BY BASE PLATE BASE PLATE 60 mm CLIP (ENGAGED) BAR FIGURE 4 ON 15 OR 20MM OR TYPICAL INSTALLATION (Refer to Table A for allowable sprinkler and guard combinations) 8 mm MODEL H1 100 mm DIA. 15 mm MODEL H1 FIGURE 5 MODEL H1 OR MODEL H1 WITH ON 15MM TYPICAL INSTALLATION (Refer to Table A for allowable sprinkler, shield and guard combinations) 15 mm 32 mm MODEL H2 160 mm DIA. 15 mm MODEL H2 FIGURE 6 MODEL H2 OR MODEL H2 WITH ON 15MM TYPICAL INSTALLATION (Refer to Table A for allowable sprinkler, shield and guard combinations) 15 mm

Page 5 of 8 8 mm MODEL H1 100 mm DIA. 20 mm MODEL H1 FIGURE 7 MODEL H1 OR MODEL H1 WITH ON 20MM TYPICAL INSTALLATION (Refer to Table A for allowable sprinkler, shield and guard combinations) 20 mm 32 mm MODEL H2 160 mm DIA. 20 mm MODEL H2 FIGURE 8 MODEL H2 OR MODEL H2 WITH ON 20MM TYPICAL INSTALLATION (Refer to Table A for allowable sprinkler, shield and guard combinations) 20 mm Installation Installation instructions are provided in the following subsections: Sprinkler Only Installation Sprinkler with Guard Installation Sprinkler with Shield Installation Sprinklers with Guard and Shield Installation Refer to the Sprinkler Only Installation subsection for general instructions. Sprinkler Only Installation The Model TY-FRFS, TY-FS Special, and TY-FS Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1,6 mm for 57 C to 2,4 mm for the 141 C temperature ratings. A leak-tight ISO 7-R 3/8 sprinkler joint should be obtained by applying a minimum-to-maximum torque of 8 to 16 Nm. A leak tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 9,5 to 19,0 Nm. A leak tight 3/4 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 13,4 to 26,8 Nm. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insufficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Note: Pendent sprinklers are to be installed in the pendent position; upright sprinklers are to be installed in the upright position. Step 1. With pipe thread sealant applied to the pipe threads, handtighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 10). With reference to Figures 1, 2, and 3 the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats.

Page 6 of 8 WITH PROPERLY INSTALLED, CAREFULLY SPREAD BASE PLATES APART AND FIT ONTO THREAD RELIEF SWIVEL CLIPS OVER ADJACENT BARS AND SLIDE TOWARD BASE PLATES UNTIL SNUG BAR SLOT FIRST CLIP FULLY ENGAGED INSTALLATION TOOL (SHIPPED WITH S) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) WRENCH RECESS BASE PLATES PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH WRENCHING AREA WRENCH RECESS (END "A" USED FOR ISO 7-R 3/8 AND 1/2" NPT MODELS) INSTALLATION TOOL CLIP WITH INSTALLATION TOOL APPLIED OVER ADJACENT BARS, PRESS SECOND CLIP TOWARD BASE PLATES UNTIL FULLY ENGAGED FIGURE 9 INSTALLATION PROCEDURE FIGURE 10 W-TYPE 6 WRENCH FIGURE 11 W-TYPE 7 RECESSED WRENCH Sprinkler with Guard Installation SECOND CLIP FULLY ENGAGED INSTALLATION TOOL CLIP A PLIER MAY BE USED With reference to Figures 4 and 9, 15 mm or 20 mm Upright or Pendent Sprinklers with Model G1 Guard must be installed in accordance with this section: Step 1. The G1 Guard is to be mounted on the sprinkler after the sprinkler has been installed in accordance with the Sprinklers Only Installation subsection. Step 2. With the Clips loose, first spread the two halves of the Sprinkler Guard just enough to pass by the sprinkler deflector from the side. Then, once again spread the two halves of the Sprinkler Guard just enough to pass over the Thread Relief portion of the sprinkler. (Ref. Figures 2 and 3) Step 3. With the Sprinkler Guard positioned on the Thread Relief portion of the sprinkler, as applicable, engage the Clips and then slide the Clips until they seat against the Base Plate to complete the installation as shown in Figure 4. To help assist with the sliding of the Clips, the Guard Installation Tool maybe used as shown in Figure 9. In addition, pliers can be used to facilitate the final seating of the Clips. Note: The Clips must seat against the Base Plate in order to be considered fully seated and in order to complete the installation. The G1 Guard may be located in any position relative to the sprinkler frame arms. Sprinkler with Shield Installation With reference to Figures 5, 6, 7, or 8, 15 mm or 20 mm Pendent Sprinklers with Model H1 or Model H2 Shield must be installed in accordance with this section: Note: Pendent sprinklers are to be installed in the pendent position. Step 1. With pipe thread sealant applied to the pipe threads, install the Shield over the sprinkler threads. Step 2. Place the Attachment Spring over the sprinkler threads, seating it against the Shield. Step 3. Hand-tighten the sprinkler into the sprinkler fitting. Step 4. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 11). The wrench is to be applied to the sprinkler wrenching area shown in Figures 2 or 3, as applicable. Note: When installed correctly, the Attachment Spring will be slightly compressed and the Shield will be held firmly in place. Sprinkler with Guard and Shield Installation With reference to Figures 5, 6, 7, or 8, 15 or 20 mm Pendent Sprinklers with Model H1 or Model H2 Shield and Model G1 Guard must be installed in accordance with this section: Note: Pendent sprinklers are to be installed in the pendent position. Step 1. With pipe thread sealant applied to the pipe threads, install the Shield over the sprinkler threads. Step 2. When installing K115 Sprinklers, place the Attachment Spring over the sprinkler threads, seating it against the Shield. Note: An Attachment Spring is not utilized for K80 Sprinklers with Guard and Shield. Step 3. Hand tighten the sprinkler into the sprinkler fitting. Step 4. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Sprinkler Wrench (Ref. Figure 11). The wrench is to be applied to the sprinkler wrenching area shown in Figures 2 or 3, as applicable. Step 5. After the sprinkler with shield is installed into the sprinkler pipe fitting, install the guard as described in the Sprinkler with Guard Installation subsection.

Page 7 of 8 P/N 51 XXX 1 XXX FINISH 1 NATURAL BRASS TEMPERATURE RATING 135 135 F (57 C) 155 155 F (68 C) 175 175 F (79 C) 200 200 F (93 C) 286 286 F (141 C) MODEL TY-FRFS MODEL TY-FS SPECIAL MODEL TY-FS DESCRIPTION DESCRIPTION DESCRIPTION 380 TY1136 K57, ISO 7-R 3/8 382 TY1236 K57, ISO 7-R 3/8 370 TY3136 K80, 1/2 NPT 371 TY3236 K80, 1/2 NPT 390 TY4136 K115, 3/4 NPT 391 TY4236 K115, 3/4 NPT Care and Maintenance The Model TY-FRFS, TY-FS Special, and TY-FS Sprinklers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has 480 TY1146 K57, ISO 7-R 3/8 482 TY1246 K57, ISO 7-R 3/8 470 TY3146 K80, 1/2 NPT 471 TY3246 K80, 1/2 NPT 490 TY4146 K115, 3/4 NPT 491 TY4246 K115, 3/4 NPT TABLE B S PART NUMBER SELECTION lost liquid from its bulb (Ref. Installation section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the Authorities Having Jurisdiction. Contact the installing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and part number (P/N). Note: Sprinklers, wrenches, guards, shields, attachment springs, and additional clip installation tool are all sold separately. 580 TY1156 K57, ISO 7-R 3/8 582 TY1256 K57, ISO 7-R 3/8 570 TY3156 K80, 1/2 NPT 571 TY3256 K80, 1/2 NPT 590 TY4156 K115, 3/4 NPT 591 TY4256 K115, 3/4 NPT Sprinkler Assemblies Specify: Model (TY-FRFS, TY-FS Special, or TY-FS), (specify ), (specify Standard, Special, or Quick) Response, (specify 57, 80, or 115) K-factor, (specify temperature rating), (specify Pendent or Upright) Sprinklers, P/N (specify from Table B) Sprinkler Wrenches Specify: W-Type (specify) Sprinkler Wrench, P/N (specify): W-6.... 56-000-6-387 W-7... 56-850-4-001 Guards Specify: Model G1 Guard with (specify) finish, P/N (specify): Red Painted... 56-000-6-387 Zinc Chromate... 56-850-4-001 Shields Specify: Model (specify), (specify NPT size) Shield, P/N (specify): H1, 1/2 NPT....................... 22521 H1, 3/4 NPT........................ 22522 H2, 1/2 NPT....................... 22529 H2, 3/4 NPT....................... 22524 Attachment Springs Specify: (specify NPT size) Shield Spring, P/N (specify): 1/2 NPT........................... 22526 3/4 NPT........................... 22527 Additional Clip Installation Tool Specify: Clip Installation Tool for G1 Guard, P/N 56-000-8-597 The Clip Installation Tool is included with guard orders in original cartons.

Page 8 of 8 GLOBAL HEADQUARTERS 1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 Copyright 2015 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of DuPont Corporation.