Rheem Digital gas heater

Similar documents
NO ONE PUTS MORE INTO THEIR POOL HEATERS

NO ONE PUTS MORE INTO THEIR POOL HEATERS

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN

High Efficiency Pool and Spa Heater

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

DIVISION FINNED WATER-TUBE WATER HEATERS

Raypak Residential Products

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

FINNED WATER-TUBE POOL HEATERS

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

Models HD101 thru 2342B

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

Proudly assembled in U.S.A

WATER-TUBE POOL HEATERS

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

WATER-TUBE POOL HEATERS

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

HEATERS AND HEAT PUMPS HEATERS & HEAT PUMPS HEATERS AND HEAT PUMPS FOR SWIMMING POOLS AND SPAS

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

Heaters & Heat Pumps. Heaters and Heat Pumps. Heaters and Heat Pumps for Swimming Pools and Spas

DIVISION FINNED WATER-TUBE BOILERS

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

Tankless Water Heaters

Less Than.25% Lead Proudly Assembled in the U.S.A

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Less Than.25 Pb Proudly made in the U.S.A

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

Proudly assembled in U.S.A

Proudly assembled in U.S.A

DIVISION FINNED WATER-TUBE BOILERS

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

DIVISION FINNED WATER-TUBE BOILERS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Less Than.25% Lead Proudly Assembled in the U.S.A

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

FTIIIC-10. Domestic Hot Water Heaters and Boilers

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

Residential/Commercial Gas Condensing Tankless Models

DOM-5. Domestic Hot Water Heaters & Boilers

Domestic Hot Water Heaters and Boilers FTIIIC-6

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

comfort BY CONTROL POOL AND SPA HEATING SOLUTIONS

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST

High efficiency, cast-iron gas boiler

FXLF-9. High Efficiency Water Heaters and Boilers

Commercial Tankless Rack System

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

THE HARD WATER WATER HEATER

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Triton Series High Efficiency Boiler

INSTALLATION AND OPERATING INSTRUCTIONS

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

WARNING: If these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

DIVISION FINNED WATER-TUBE BOILERS

Commercial Tankless Rack System

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

97% Thermal Efficiency

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

INSTALLATION & OPERATING INSTRUCTIONS

FXLF-4. High Efficiency Water Heaters and Boilers

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Tankless Condensing High Efficiency Water Heaters

Residential Gas Tankless Water Heater

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Now Available as a Mobile App:

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Commercial Tankless Rack System

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Instructor: Sales person: Phone: Sales person: Phone: Sales person: Phone: Sales person: Phone: Service Manager: Phone: Service Manager: Phone:

Gas-Fired Pool & Spa Heater

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

High Efficiency Commercial Gas Water Heaters

Commercial Boilers and Domestic Water Heaters APG-5

SWIMMING POOL & SPA HEATER D-2

Commercial Tankless Rack System

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

WARNING: If these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

FORCED AIR HEATING VARIFLAME HEATERS

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Burner Comparisons. Typical Competitor s Burner

SENSEI Series Features

Click Here To View Item at

SWIMMING POOL & SPA HEATER D-2

Transcription:

Self-Diagnostic Se n s o r F a i l u r e Remote-Compatible Re m o t e W a t e r Po o l Te m p Run Time and Cycle Meter Ru n T i m e 1 0 0 h C y c l e s 134 Flame Strength Indicator Fl a m e 104F 6 9 F S t r e n g t h G o o d 8 On Board Voltmeter Su p p l y V o l t a g e 2 8. 2 Microprocessor-Controlled Thermostat Sp a S e t H e a t i n g 1 0 4 F Rheem Digital gas heater The Rheem Digital gas heater is equipped with a microprocessor-based control. This control allows you to set your pool and spa temperature precisely at your preferred setting just by pressing an up or down temperature control button. The digital display tells you when the water is being heated and notifies you when your target temperature has been reached. Troubleshooting a Rheem gas heater has never been easier. The Rheem Digital has on-board diagnostic controls that let the user and the service professional know what is going on with the heater at all times. The display uses real English, with no cryptic codes to decipher. The Rheem Digital is compatible with most major pool control and remote systems on the market today. Any two- or three-wire remote can connect to the Rheem Digital and be integrated into the pool control system of your choice. The display clearly shows the heater is under control of a remote system. Yet another industry first, the Rheem pool heater can report how long it has run and how many times it has fired. This is valuable feedback for the service professional. Multi-unit installations can monitor the run time of each unit and balance out the duty load, thus avoiding over working one individual heater. Rheem leads the way with the first control in the pool industry to monitor and measure the pilot flame signal. Known for our high quality, leading edge commercial boilers, it just made sense for Rheem to use this existing commercial technology on our residential pool heaters. Rheem also uses this function on the end of line test, making sure every heater leaves with a robust flame signal. The Rheem Digital monitors the low voltage electrical supply. This helps ensure the heater is wired properly during installation. The heater will also let you know if the voltage has dropped too low to function properly. No other pool heater takes care of you like a Rheem. Stainless Steel Burners Burner design is a critical component in any gas heater. The stainless steel burner system used in the Rheem Digital is inherently forgiving and extremely robust. The burner is self-adjusting to compensate for gas pressure fluctuations, meaning the heater will always burn clean and safe. Smooth Light Off The soft-opening gas valve ensures smooth turn-on; no Hard Light to worry about. Easily removable burner tray and pilot assembly make service and maintenance a simple task. Pilot Ignition The Rheem Digital use a spark-to-pilot ignition system. This is the most reliable and robust ignition system available an industry proven standard for over 30 years. N o D e m a n d Sp a S e t N o P i l o t 1 0 4 F S e n s e d POOL & SPA HEATERS Model BTUH Input 206 199,500 266 266,000 336 332,500 406 399,000 Condensation-Free Operation Both water temperature and flow rate inside the heater are controlled to help eliminate condensation, sooting and scale buildup that can shorten the life of a heater. Rheem engineered the Unitherm Governor specifically for pool and spa heater applications, regulating low temperature incoming water to help reduce condensation. Rust-Free Waterways The Rheem Digital is equipped with polymer headers and an integral copper fin tube heat exchanger built with stainless steel tube sheets. This ensures rust-free performance, which is especially important when heating spas. Even the smallest details, such as the studs and nuts, are made out of stainless steel. The payoff? A heater that will last year after year and can easily be serviced if the need should ever arise. Quality Reliability COmfORt Wind-Resistant Design Performance and reliability are enhanced by the pagoda top, designed to keep the Rheem Digital operating even in windy conditions. No need for fans to combat drafting problems. This heater is engineered to draft naturally in outdoor installations with its exclusive low-profile design. It is so thoughtfully and carefully constructed that it actually protects itself from the things that tend to stifle ordinary pool and spa heaters. It delivers uninterrupted heating performance regardless of falling leaves, wind, airborne debris, rain, downdrafts, updrafts, sleet, snow, etc. PolyTuf Textured Powder Coating The Rheem Digital has a polyester-coated, noncorrosive cabinet that is more durable than solventborne and waterborne-coated metal cabinets. Every piece of sheet metal goes through a 7-stage wash system, making certain the powder paint has a perfect bond. Underneath the tough, yet beautiful finish, you will find galvanized metal that offers superior rust prevention for years of durable service.

Options Copper Fin Tube The Rheem Digital is built to last with the highest quality integral copper fin tube available. Copper is well known for its ability to transfer heat efficiently, and is an excellent choice for pool and spa heater heat exchangers, where the water chemistry is properly maintained. Cupro-Nickel Fin Tube Rheem heaters are available with an optional cupro-nickel fin tube heat exchanger for added protection against aggressive water chemistry, which has been known to attack copper heat exchangers and cause premature failure. Cupro-nickel's major advantage over standard copper is that it s more tolerant of bad water chemistry and is more resistant to erosion, thanks to a much harder surface and a wall that is approximately 50% thicker. When you are unsure of your ability to maintain the pool or spa water chemistry, a cupro-nickel heat exchanger is a cost-effective way to protect against premature failure. D-2 Power Vent Rheem offers an optional power vent feature. Sometimes, equipment rooms or unusual venting configurations require the use of a power vent. Being the heater experts, we have this option for you when the need may arise. Through-the-Wall Capable The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates under a positive static pressure that prevents excessive condensate production in the vent. All sizes are capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models have a standard 4 diameter exhaust connection. Multi-Position Using the Rheem-supplied adjustable 90 elbow, the flue gases may be discharged in any direction (see D-2 Power Vent manual for details). The D-2 Power Vent is also dual-voltage capable (120/240 volt) and engineered for long life and smooth operation. THE NEW DEGREE OF COMFORT TM For dimensions and technical specifications, see catalog number MKG-15-1505. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Litho in U.S.A. 2004-2011 Rheem, Inc. MKG-15-1503 Effective 10-01-2011

The Pool and Spa Heating Experts SM Raypak Digital Pool and Spa Heater

The Raypa Digital Control Microprocessor-Controlled Thermostat The Raypak Digital gas heater is equipped with a microprocessor-based control. This H e a t i n g control allows you to set your pool and spa temperature precisely at your preferred setting just by pressing an up or down temperature control button. The digital display tells you when the water is being heated and notifies you when your target temperature has been reached. N o D e m a n d Self-Diagnostic Se n s o r F a i l u r e what is going on with the heater at all times. The display uses real English, with no cryptic codes to decipher. Remote-Compatible Re m o t e W a t e r Po o l Te m p 104F 6 9 F Troubleshooting a Raypak gas heater has never been easier. The Raypak Digital has on-board diagnostic controls that let the user and the service professional know The Raypak Digital is compatible with most major pool control and remote systems on the market today. Any two- or three-wire remote can connect to the Raypak Digital and be integrated into the pool control system of your choice. The display clearly shows the heater is under control of a remote system. Run Time and Cycle Meter Yet another industry first, the Raypak pool Ru n T i m e 1 0 0 h heater can report how long it has run and C y c l e s 134 how many times it has fired. This is valuable feedback for the service professional. Multi-unit installations can monitor the run time of each unit and balance out the duty load, thus avoiding over working one individual heater. Heat Exchanger Sp a S e t N o P i l o t 1 0 4 F S e n s e d Flame Strength Indicator Raypak leads the way with the first control in the pool industry to monitor and measure the pilot flame signal. Known for our high quality, leading edge commercial boilers, it just made sense for Raypak to use this existing commercial technology on our residential pool heaters. This little tool is a service tech s dream. Raypak also uses this function on the end of line test, making sure every heater leaves with a robust flame signal. On Board Voltmeter The Raypak Digital monitors the low voltage electrical supply. This helps ensure the heater is wired properly during installation. The heater will also let you know if the voltage has dropped too low to function properly. No other pool heater takes care of you like a Raypak. Su p p l y V o l t a g e Condensation-Free Operation Both water temperature and flow rate inside the heater are controlled to help eliminate condensation, sooting and scale buildup that can shorten the life of a heater. Raypak engineered the Unitherm Governor specifically for pool heater applications, regulating low-temperature incoming water to help reduce condensation. The built-in automatic bypass helps prevent scaling and erosion by balancing the flow going into the heat exchanger. Rust-Free Waterways The Raypak Digital, with polymer headers, is equipped with an integral copper finned-tube heat exchanger and stainless steel tube sheets. Even the smallest details such as the studs and nuts are made out of stainless steel. The payoff? A heater that will last year after year and can easily be serviced if the need should ever arise. Burners Stainless Steel Burners Burner design is a critical component in any gas heater. The stainless steel burner system used in the Raypak Digital is inherently forgiving and extremely robust. The burner is self-adjusting to compensate for gas pressure fluctuations, allowing the heater to always burn clean and safe. Smooth Light Off The soft-opening gas valve ensures smooth turn-on; no Hard Light to worry about. The easily removable burner tray and pilot assembly make service and maintenance a simple task. Pilot Ignition The Raypak Digital use a spark-to-pilot ignition system. This is the most reliable and robust ignition system available an industry proven standard for over 30 years. Fl a m e S t r e n g t h G o o d 8 2 8. 2 Sp a S e t Lo w 1 0 4 F V o l t a g e

k Digital The right tube for the right application Copper Fin Tube - Residential The Raypak Digital is built to last with the highest quality integral copper fin tube available. Copper is well known for its ability to efficiently transfer heat, and is the first choice for pool and spa heat exchanger construction. Pure copper has stood the test of time as the industry standard for efficiency, quality and product life. ASME Copper Fin Tube - Commercial The Raypak Digital ASME is designed specifically to meet State and local code requirements for public pools and commercial applications. This heater is equipped with a thicker walled fin tube allowing it to meet the ASME certification requirements. Cupro-Nickel Fin Tube - Specialty Raypak Digital heaters can be ordered with cupro-nickel fin tube heat exchangers for added protection against aggressive water chemistry. Although rare, there are certain applications, like health club spa s, where copper is just not the best choice. Cupro-nickel offers superior tolerance to bad and fluctuating water chemistry, thanks to a harder surface and a thicker walled fin tube. On-site state inspectors ASME ASME The Raypak Digital heater is also available in an optional ASME version. Raypak has state inspectors on-site daily performing certifications for our pool heater and commercial boiler production that may require ASME. Being in the boiler business for over 50 years truly makes Raypak the leader for your commercial needs. Why ASME? Most local codes require that public pools, pools that are in condominiums, apartments, or other commercial applications, be ASME certified. ASME stands for American Society of Mechanical Engineers, a non-profit group which sets many industrial and manufacturing standards. A pool heater that is made to ASME standards must perform to a set of specifications as determined by ASME, specifically in relation to the operating water pressure the appliance can handle. Each and every ASME heat exchanger that goes into a Raypak heater is certified by a state inspector to make sure it complies with all ASME codes for pool heaters. Glass-Lined Cast Iron Headers Raypak has applied its years of commercial boiler experience to the design of the cast iron glass-lined header. A metal header design allows for the higher working pressures required by ASME. Only after the material meets the stress analysis and metal composition tests is it approved for use in an ASME unit. Cast iron headers

Anything But Basic Cabinet Outdoor top - (standard) Wind-resistant design Channels rainwater out Textured powder-coat finish Optional indoor top Digital Controls Microprocessor-controlled Built-in diagnostics Back-lit LCD display Pool and spa settings Lexan cover- with snap closure Remote-compatible Flame strength meter Cycle and run time log Transformer output monitor Fault history-last 10 Burner Tray Easily removable Stainless steel burners Brass orifices Aluminized metals Stainless steel heat shield Spark-to-pilot ignition Soft-opening gas valve Model BTUH Input 206 199,500 266 266,000 336 332,500 406 399,000 Heat Exchanger Integral copper fin tube - (standard) Automatic bypass Unitherm governor Polymer headers Stainless steel tube sheet Reversible for left-side water connections. ASME - (optional) Cupro-nickel - (optional) 2 CPVC Connections High Limits and Controls Mounted on the in/out header Ceramic Fiber Combustion Chamber Non-Combustible Base Heater can be installed on a combustible surface 120/240V Incoming power can be connected to the right or left side. Optional D-2 Power Vent D-2 Power Vent Sometimes, equipment rooms or unusual venting configurations require the use of a power vent. Being the heater experts, we have this option for you when the need may arise. Through-the-Wall Capable The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates under a positive static pressure and prevents excessive condensate production in the vent. All sizes are capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models have a standard 4 -diameter exhaust connection. Multi-Position Using the Raypak-supplied adjustable 90 elbow, the flue gases may be discharged in any direction (see D-2 Power Vent manual for details). The D-2 Power Vent is also dual-voltage capable (120/240 volt) and engineered for long life and smooth operation. D-2 Power Vent For dimensions and technical specifications, see catalog number 6000.35. In keeping with its policy of continuous progress and product improvement, Raypak reserves the right to make changes without notice. Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030, (805) 278-5300. Fax (800) 872-9725 www.raypak.com Litho in U.S.A. 2008-2011 Raypak, Inc. Catalog No. 6000.12F Effective: 02-15-13 Replaces: 05-01-11

The Pool and Spa Heating Experts SM Raypak Versa 130 Pool and Spa Heater

Technical Data Raypak Versa 130 Gas Heater 6 15-13/32 4-1/4 4-3/8 46-41/64 HIGH WIND OUTDOOR TOP (OPTIONAL) 26-55/64 THERMOSTAT 18-1/4 ELECTRICAL CONNECTION ON/OFF SWITCH 21-21/32 32-21/32 STACKLESS OUTDOOR TOP (SUPPLIED) 42-3/8 INDOOR DRAFTHOOD (OPTIONAL) BTU INPUT SHIPPING WEIGHT (lbs) 130,000 125 11-7/16 GAS CONNECTION ALL DIMENSIONS ARE IN INCHES 12-7/8 26-11/32 An electronic heater using propane gas is EP ; an electronic heater using natural gas is EN. A Millivolt heater using propane gas is MP ; a Millivolt heater using natural gas is MN. Prefix P is for plastic (polymer) headers. Suffix X is for cupro-nickel tubing; C is for copper tubing Example: P-R130A-EN-X = Plastic headers, 130 model size, electronic ignition, natural gas, cupro-nickel Versa 130 Standard Features All models PolyTuf Textured Powder Coating The Raypak gas heater has a polyester-coated, non-corrosive cabinet that is more durable than solventborne- and waterborne-coated metal cabinets. Every piece of sheet metal goes through a 7-stage wash system, making certain the powder paint has a perfect bond. Underneath the tough, yet beautiful finish you will find galvanized metal that offers superior rust prevention and years of durable service. Wind-Resistant Design No need for fans to combat drafting problems. This heater is designed to draft naturally in outdoor installations with its exclusive low-profile design. It is so thoughtfully and carefully designed it actually protects itself from the things that tend to stifle ordinary pool and spa heaters. It delivers uninterrupted heating performance regardless of falling leaves, wind, airborne debris, rain, downdrafts, updrafts, sleet, snow, etc. Polymer Headers Polymer headers prevent rust stains from harming your pool or spa s surface, giving you years of trouble-free swimming pleasure. All-Copper-Fin-Tube Heat Exchanger The fin tubes of the heat exchanger are each made from a single piece of extruded copper. This integral-fin design allows maximum heat transfer to be attained and maintained. Cupro-nickel is also available as an optional upgrade. Stainless Steel Tube Sheet Stainless steel tube sheets are used on all Raypak gas heaters. This allows for a completely nonferrous waterway, leaving your pool truly rust-free. 2" Water Connections Supplied with every Raypak heater is a set of 2" PVC connections to make your installation secure and effortless. Burner Tray Every burner tray is built to last, from the stainless steel burners to the aluminized metal used in the heat sensitive areas. Innovative design allows for the easy removal of the tray and burners for servicing. Fire Tile A ceramic fiber combustion box keeps your heater running efficiently while keeping the outside jacket cool. By using this space-age material the heater won't retain residual heat after it is turned off, allowing it to be installed without the use of costly metal heat sinks. Fuel-Efficient Energy-smart Raypak heaters consistently achieve the highest efficiency ratings. They exceed all federal and state standards. Electronic ignition models only Electronic Ignition Raypak electronic ignition heaters come standard with direct spark ignition flame safety controls. What this means is that the heater only comes on when there is a call for heat. This provides an energy-efficient way to control your heater s gas usage by eliminating the need for a continuous pilot. Dual Voltage 120/240v The Raypak electronic heater can easily be hooked up to 120v power via its own 3-1/2 foot built in power cord with 3-prong plug. It can also be wired for use with a conduit connection, this allows the installer to wire 120/240v directly to the transformer. No other small heater offers you this much flexibility. Millivolt models only Mechanical Thermostat The Raypak millivolt gas heater comes with one mechanical thermostat. This control allows you to set your pool or spa temperature precisely at your favorite setting. Millivolt Controls No power source is required for the Raypak Millivolt heater. All operating electricity is supplied by the pilot thermocouple. Quality assurance ISO 9001 We are proud to be an ISO 9001 registered manufacturing plant. It s one more reason why Raypak is number one in the heater industry today. End-of-Line Test Every Raypak gas pool heater is plumbed and test-fired before it is put in the carton. This ensures that your heater will work right out of the box and continue to give you years of trouble-free operation. Quality Check Points The Raypak assembly process includes six final assembly quality check points that help to ensure that every Raypak gas heater is built correctly, and built to last. CSA-Certified All of Raypak s gas pool heaters are CSA-certified and are tested by CSA to the ANSI Z21.56 standard. In keeping with its policy of continuous progress and product improvement, Raypak reserves the right to make changes without notice Raypak, Inc. 2151 Eastman Avenue,Oxnard, CA 93030 Phone (805) 278-5300, Fax (800) 872-9725 www.raypak.com Swimming Pool and Spa Heating Products 6100.28D 01-15-12