FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

Similar documents
FAIRA TRANSPARENCY REPORTS st Ave, #605, Seattle, WA June 2 nd, 2017

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

FAIRA TRANSPARENCY REPORTS S 272nd St, #39, Kent, WA September 1 st, 2017

FAIRA TRANSPARENCY REPORTS NE 182nd St, C101, Kenmore, WA 98028

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS th Ave S, A304, Des Moines, WA March 13, 2018

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

FAIRA TRANSPARENCY REPORTS S 284th Ln, #H204, Federal Way, WA March 12, 2018

Amendment to the Inspection Report

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

FAIRA TRANSPARENCY REPORTS W Villa Monte Dr, Mukilteo, WA August 8 th, 2017

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

FAIRA TRANSPARENCY REPORTS S 237th St, Kent, WA November 28, 2017

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

26632 Timberlane Dr SE, Covington, WA 98042

FAIRA TRANSPARENCY REPORTS st Ave SE, Renton, WA 98058

FAIRA TRANSPARENCY REPORTS SE 240th Pl, Maple Valley, WA June 5th, 2017

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS Interlake Ave N, Seattle, WA February 1, 2018

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS nd Ave SE, Renton, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS th Ave SE, Bothell, WA 98012

FAIRA TRANSPARENCY REPORTS. 553 Chelan Pl NE, Renton, WA March 3 rd, 2018

FAIRA TRANSPARENCY REPORTS nd Ave SW, Burien, WA October 26 th, 2017

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

FAIRA TRANSPARENCY REPORTS th Ave NW, Seattle, WA 98107

FAIRA TRANSPARENCY REPORTS Chestnut Street, Everett, WA 98201

FAIRA TRANSPARENCY REPORTS W Crockett St., Seattle, WA September 5 th, 2017

FAIRA TRANSPARENCY REPORTS W James St, 8, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS Wells Ct S, Renton, WA 98055

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS th Ln NE, Issaquah, WA February 1, 2018

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS th Pl W, Lynnwood, WA 98087

FAIRA TRANSPARENCY REPORTS. 706 N 103rd St, Seattle, WA August 14, 2017

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS th Ave N, Edmonds, WA January 19 th, 2018

FAIRA TRANSPARENCY REPORTS rd Pl SE, Maple Valley, WA April 4 th, 2017

FAIRA TRANSPARENCY REPORTS NE 178th St, Lake Forest Park, WA May 2 nd, 2017

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE, Seattle, WA August 23 rd, 2017

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006

FAIRA TRANSPARENCY REPORTS th Pl SE, Covington, WA May 17 th, 2017

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

RW West Consultants, Inc. Property Inspection Report Inspector: Clifton Moody (Skip), RW West Consultants, Inc. Cover Page

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

Troy's Home Inspection Services LLC

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave N, Seattle, WA 98109

RW West Consultants. Property Inspection Report

FAIRA TRANSPARENCY REPORTS. March 14 th, 2017

FAIRA TRANSPARENCY REPORTS Burke Ave N, Seattle, WA March 14, 2018

FAIRA TRANSPARENCY REPORTS. 609 Union Avenue NE, Renton, WA 98059

FAIRA TRANSPARENCY REPORTS th Ave NE, Kirkland, WA February 16, 2018

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

FAIRA TRANSPARENCY REPORTS. July 6, 2016

FAIRA TRANSPARENCY REPORTS. 808 NW 125th St, Seattle, WA February 12, 2018

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

FAIRA TRANSPARENCY REPORTS S 298th St, Auburn, WA March 28 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, Seattle, WA November 9, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, SeaTac, WA August 4, 2017

FAIRA TRANSPARENCY REPORTS rd Ave SW, Vashon, WA May 19 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, Des Moines, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS SE 225th St, Maple Valley, WA June 2nd, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE, Arlington, WA 98223

Hearth and Homes Inspections, llc

FAIRA TRANSPARENCY REPORTS NE 116th Pl, Kirkland, WA April 20 th, 2017

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

Inspector Gadget Homes

FAIRA TRANSPARENCY REPORTS. 76 Cedar ST, Unit 505, Seattle, WA May 27, 2016

FAIRA TRANSPARENCY REPORTS Silver Springs Dr NW, Gig Harbor, WA February 20, 2018

Axiom Property Inspections

FAIRA TRANSPARENCY REPORTS. January 6 th, 2017

Inside Out Home Inspections

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

Patriot Home Inspections

Jeff Brown Inspections

Extra Mile Inspection, Inc.

Transcription:

608 State St. South Kirkland, WA 98033 www.faira.com hello@faira.com +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 11550 Stone Ave N, #205, Seattle, WA 98133 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/11817 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We re happy you ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Cover Page RW West Consultants, Inc. Property Inspection Report 11550 Stone, Unit 205, Seattle, WA Inspection prepared for: Real Estate Agent: - Date of Inspection: 3/22/2018 Age of Home: 2000 Size: 950 This is an inspection of this unit only. Exterior conditions and common areas are generally the responsibility of the condominium association. Recommend you review your resale certificate or public offering statement. Inspector: Clifton Moody (Skip) License # 957 Email: rwwestconsultants@gmail.com

Inspection Details We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFI outlets may not be installed; For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. Items denote serious, safety or items that required further investigation Items denote minor or maintenance items Green notes denote locations and shutoff valves 1. Attendance In Attendance: Seller present 2. Home Type Home Type: Condominium/Townhouse 3. Occupancy Occupancy: Vacant - Furnished Page 2 of 28

1. Driveway and Walkway Condition Patio areas appeared in good condition overall. Exterior Areas 2. Electrical Exterior outlets operate overall Exterior outlets are GFCI protected overall Page 3 of 28

1. Conditions Entryway Ceiling and walls are in good condition overall. Light fixture operates. Entry door operates and locks overall. Page 4 of 28

1. Living Room Living Room Walls and ceilings appear in good condition overall. Flooring is carpet. Accessible outlets operate. Electric convector heat operates. 2. Window-Wall AC or Heat 3. Fireplace Fireplace is a gas unit. Observations: Gas Shutoff is located inside access panel under glass. Pilot Controls are located inside access panel under glass. Fireplace inducing low levels of carbon monoxide into the living area. 1ppm after 12 minutes. Recommend servicing the unit by licensed HVAC contractor. Maximum allowable exposure is 12ppm per hour in accordance with ASHRAE. Page 5 of 28

2 Gas Shutoff is located inside access panel under glass. 2 Pilot Controls are located inside access panel under glass. Page 6 of 28

1. Kitchen Room Kitchen Walls and ceilings appear in good condition overall. Flooring is vinyl. Accessible outlets operate. Light fixture operates. Sink and faucets are in operable condition overall. Cabinet doors and drawers are in operable condition overall. 2. Counter Condition Formica counter is in good condition overall. 3. Dishwasher Observations: Dishwasher drains from air gap, this is typically an indication of blocked drain, recommend conditions are investigated further and corrected as required by licensed plumbing contractor. 4. Stove/Oven Stove/oven were in operable condition overall. Page 7 of 28

5. Refrigerator Refrigerator was in operable condition. 6. Sinks Sink was in operable condition overall. 7. Vent Condition Vent fan appears to exhaust to the exterior. 8. Heating Electric Convector heater operates. Page 8 of 28

Page 9 of 28

1. Condition Laundry Ceiling and walls are in good condition overall. Accessible outlets operate. 2. Exhaust Fans Vent fan operates overall. 3. Dryer Dryer appeared to exhaust to the exterior. Dryer is electric Unit 220 volt electrical service for electric dryer. Page 10 of 28

4. Floor Condition Vinyl flooring appeared in good condition overall. 5. Washer Materials: Washer appeared to be in operable condition. Page 11 of 28

1. Bedroom Master Bedroom Walls and ceilings appear in good condition overall. Flooring is carpet in good condition. Accessible outlets operate. 2. Heating Electric Convector heater operates. 3. Doors Observations: Guides missing at the base of closet door. Page 12 of 28

Page 13 of 28

1. Room Master Bathroom Ceiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates. Entry door is in operable condition overall. 2. Electrical GFI outlets within 6 feet of the water sources. 3. Exhaust Fans Vent fan operates overall. 4. Floors Vinyl Flooring appeared in good condition overall. Observations: Delamination to the entry door trim and discoloration to the floor from water penetration from shower. Moisture meter did not indicate high moisture conditions at time of inspection. Page 14 of 28

5. Shower Shower is in good condition overall. Observations: Shower head leaks. 6. Toilet Toilet was in operable condition overall. Page 15 of 28

1. Bedroom Room Bedroom 1 Walls and ceilings appear in good condition overall. Flooring is carpet. Accessible outlets operate. 2. Heating Electric Convector heater operates. 3. Doors Observations: Guides missing at the base of closet door. Page 16 of 28

Page 17 of 28

1. Location Materials: Bedroom Bathroom This Room 2. Room Ceiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates. 3. Electrical GFI outlets within 6 feet of water sources. 4. Counters Formica counter tops are in good condition overall. 5. Exhaust Fans Vent fan operates overall. 6. Floors Vinyl Flooring appeared in good condition overall. Observations: Delamination to the baseboards from water penetration. Moisture meter did not indicate high moisture conditions at time of inspection. Page 18 of 28

Page 19 of 28

1. Plumbing Plumbing/Water Heater1 Water lines were CPVC plastic. Drain and waste lines are cast iron and plastic 2. Water Heater Condition Heater Type: Electric water heater. 40 gallons Location: The heater is located in the hall closet. 3. Age Less than 1 year of age, average life span is 10 to 12 years. 4. Condition Seismic straps are in place. Expansion tank is in place. Water heater has drip pan in place. Outlet drain in back. 5. TPRV Condition Temperature Pressure Relief Valve (TPR Valve) present. Page 20 of 28

Page 21 of 28

1. Electrical Electrical 1 200 AMP service, 4/0 Aluminum service entrance wires. 2. Grounding Observations: Grounding not visible is a common condition in condominiums and town homes. 3. Wiring Type Breaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiring is copper. Page 22 of 28

1. Shutoff Locations Shutoffs Observations: Recommend consulting with owner on location of main water shutoff. 2 Water heater water line shutoff is located above the water heater. Page 23 of 28

1. Appliances/Equipment Equipment Observations: Oven Refrigerator Dishwasher Washer Dryer Fire sprinkler system present. Testing and inspection of this system is not within the scope of inspection. System should typically be back flow tested on an annual basis. 2 Washer 2 Refrigerator 2 Stove 2 Dishwasher Page 24 of 28

2 Water Heater 2 Fire sprinkler system present. Testing and inspection of this system is not within the scope of inspection. System should typically be back flow tested on an annual basis. Page 25 of 28

1. Carbon Monoxide Carbon Monoxide Detectors Materials: Carbon monoxide detectors were in place. Page 26 of 28

Glossary Term Air Gap Expansion Tank GFCI TPR Valve Definition Glossary Air gap (drainage): The unobstructed vertical distance through free atmosphere between the outlet of the waste pipe and the flood-level rim of the receptacle into which the waste pipe is discharged. An expansion tank or expansion vessel is a small tank used to protect closed (not open to atmospheric pressure) water heating systems and domestic hot water systems from excessive pressure. The tank is partially filled with air, whose compressibility cushions shock caused by water hammer and absorbs excess water pressure caused by thermal expansion. A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system. The thermostat in a water heater shuts off the heating source when the set temperature is reached. If the thermostat fails, the water heater could have a continuous rise in temperature and pressure (from expansion of the water). The temperature and pressure could continue to rise until the pressure exceeds the pressure capacity of the tank (300 psi). If this should happen, the super-heated water would boil and expand with explosive force, and the tank would burst. The super-heated water turns to steam and turns the water heater into an unguided missile. To prevent these catastrophic failures, water heaters are required to be protected for both excess temperature and pressure. Usually, the means of protection is a combination temperature- and pressurerelief valve (variously abbreviated as T&P, TPV, TPR, etc.). Most of these devices are set to operate at a water temperature above 200 F and/or a pressure above 150 psi. Do not attempt to test the TPR valve yourself! Most water heating systems should be serviced once a year as a part of an annual preventive maintenance inspection by a professional heating and cooling contractor. From Plumbing: Water Heater TPR Valves Page 27 of 28

Report Summary Report Summary This is a visual inspection. No destructive testing is performed. This is not a soil inspection nor do we inspect for formaldehyde, radon, asbestos, Chinese drywall, lead paint, mold, hazardous materials/substances, landscape lighting, sprinkler systems, septic systems/drain fields, smoke alarms or recreational equipment such as Jacuzzis etc.. It is recommended that noted deficiencies be investigated further by licensed companies specializing in those disciplines. Inspection is subject to conditions at the time of inspection. Appliances are checked to see if they're in operable condition. This is not a code inspection as codes change frequently and vary between municipalities. We make no guarantees for expected life. It is impossible to verify conditions of places inaccessible in walls under and in between floors, behind furniture appliances etc., and we assume no responsibility for those items as such. Estimates for repairs are approximations and we do not guarantee their accuracy. Possible solutions for problems are solely opinions based on conditions at the time of the inspection and are not to be assumed as being totally conclusive The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expenses or further investigation to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all of the pages of the report as the summary alone does not explain all the issues. We recommend repairs should be done by licensed &bonded contractors. We also recommend obtaining a copy of all receipts, warranties and permits for the work done. Living Room Page 5 Item: 3 Fireplace Fireplace inducing low levels of carbon monoxide into the living area. 1ppm after 12 minutes. Recommend servicing the unit by licensed HVAC contractor. Maximum allowable exposure is 12ppm per hour in accordance with ASHRAE. Kitchen Page 7 Item: 3 Dishwasher Dishwasher drains from air gap, this is typically an indication of blocked drain, recommend conditions are investigated further and corrected as required by licensed plumbing contractor. Shutoffs Page 23 Item: 1 Shutoff Locations Recommend consulting with owner on location of main water shutoff. Page 28 of 28