Keywords: Micro channel condenser, refrigeration system, heat transfer rate, refrigerant Effect.

Similar documents
Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

REVIEW PAPER ON REFRIGERATION SYSTEM USING MICROCHANNEL CONDENSER

Global Journal of Engineering Science and Research Management

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Study and Investigation of Refrigeration System Using Microchannel Condensers and round tube condenser-review

Investigation of Port Level Refrigerant Flow Mal-distribution in Microchannel Heat Exchanger

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Development and Application of Micro Channel Heat Exchanger for Heat Pump

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Design Optimization of Variable Geometry Microchannel Heat Exchangers

2. HEAT EXCHANGERS MESA

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Dae-Hyun Jin. 8/2018-Present Assistant Professor of Mechanical Engineering, Taylor University, USA

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Performance Study of Triple Concentric Pipe Heat Exchanger

Implementation of Microchannel Evaporator for High-Heat-Flux Refrigeration Cooling Applications

Quantification of Liquid Refrigerant Distribution in Parallel Flow Microchannel Heat Exchanger Using Infrared Thermography

Design and analysis of household direct cool refrigerator with vertical evaporator

Falling Film Heat Exchangers for Solar Water Heaters

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Performance of CO2 Cycles with a Two-Stage Compressor

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Flow Boiling of R245fa in a Microgap with Integrated Staggered Pin Fins

Thermal Performance of a Loop Thermosyphon

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

IJARI. 1. Introduction: Heat Pipes. Volume 3, Issue 3 (2015) ISSN International Journal of Advance Research and Innovation.

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Mini Vapour Cycle System For High Density Electronic Cooling Applications

In the name of God. Jami Institute of Jami - Mehdi Rasti

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Pressure drop characteristics of cryogenic mixed refrigerant at macro and micro channel heat exchangers

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

Performance investigation of Air-conditioning system using ejector as expansion device

Pool boiling heat transfer enhancement on porous surface tube

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Purdue e-pubs. Purdue University

Comparison of Oil Retention in R134a and CO 2 Climate Control Systems

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

15. Heat Pipes in Electronics (1)

The Effects of Hydrophilicity on Water Drainage and Condensate Retention on Air-Conditioning Evaporators

Experimental Investigation Of A New Low- Approach Evaporator With Reduced Refrigerant Charge

Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES


CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Performance of an Improved Household Refrigerator/Freezer

EXPERIMENTAL EVALUATION OF CONDENSATION HEAT TRANSFER COEFFICIENT OF R-417A IN HORIZONTAL TUBES

Compression of Fins pipe and simple Heat pipe Using CFD

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Transcription:

IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY A Review on Performance Enhancement of Microchannel Condenser in Refrigeration System Vandana Jatav *1, R.C.Gupta 2 1, 2 Department of Mechanical Engineering, Jabalpur Engineering college, Jabalpur, India jatavvandana@rediffmail.com Abstract This review paper presents the work on the performance of condenser used in refrigeration system by the various researches. Micro channel condenser used to enhance the performance of various parameters like heat transfer, pressure drop, energy efficient ratio, COP and refrigerant effect of the system. In refrigeration system condenser is a vital part. Micro channel heat exchanger has been increasingly applied in HVAC&R (Heating, ventilation and air conditioning & refrigeration) field due to its higher efficiently heat transfer rate more compact structure. Keywords: Micro channel condenser, refrigeration system, heat transfer rate, refrigerant Effect. 1. INTRODUCTION Micro channel condenser is an effective enhancement technique for its relatively high heat transfer coefficient and low pressure drop penalty. micro channels bring to the overall performance of the heat exchanger include the increase in compactness, possible reduction of the air-side pressure drop, improvement of the heat transfer, and the Reduction of the refrigerant charge. It is also frequently used in automotive refrigerant condensers, which use aluminum tubes. It can reduce equipment weight, improve the device compactness, also reduced the manufacturing cost &competitiveness can be improved by using aluminums. Air conditioning and refrigeration system plays an important role in industry, infrastructure and household. The industry sectors include the food industries, textiles chemicals, printings, transports and others. Infrastructure includes banks, restaurants, schools, hotels and recreational facilities. The micro channel condenser is made to have nearly an identical face area, depth and fin density as the round tube condenser which is the baseline. Micro channel condenser should provide higher capacity and system COP. The objective of this paper is to summarize the benefits of micro channel coils in air conditioning applications. The flat shape of the micro channel reduces the power necessary to move the air through the heat exchanger (air-side pressure drop), compared to round-tube heat exchangers. The shape of the micro channel tubes and fins also increases the air side heat transfer coefficient. Decreasing the hydraulic diameter of the micro channel tube and increasing the number of ports, increases the local heat transfer coefficients. Increasing the local heat transfer coefficient on both sides decreases the required size of the heat exchanger therefore reducing the amount of tubing necessary for a specific heat load. Decreasing the hydraulic diameter of the tube also decreases the volume of the tube and the refrigerant quantity. The only disadvantage causes due to reduction of the hydraulic diameter in the micro channel tube is that the refrigerant pressure drop increases for the Same mass flux or even worse for the same number of tubes never the less increasing the number of tubes one could Mitigate the problem to some extent. Higher pressure drops require more pumping power and higher energy Consumption resulting in reduction in COP (Coefficient of Performance).

2. Literature Review Weilin Qu, Issam Mudawar [2003], The study presented a water-cooled two-phase microchannel heat sink containing 21 parallel 231 713 µm micro-channels explores pressure drop and hydrodynamic instability. Two phase hydrodynamic instability of two types were identified: mild parallel channel instability and severe pressure drop. It is shown that severe pressure drop oscillations, which can trigger pre-mature critical heat flux, which eliminated simply by throttling the flow upstream of the heat sink. For predicting two-phase pressure drop are assessed for suitability to micro-channel heat-sink design different methods. Generalized two-phase pressure drop correlations are examined first, developed for both macro- and mini/micro-channels 10 correlations are include. Effects of channel size and coolant mass velocity incorporated by new correlation which shows better accuracy than prior correlations. A theoretical annular two-phase flow model comes under second method which aside from excellent predictive capability, possesses the unique attributes of providing a detailed description of the various transport processes occurring in the micro-channel, as well as fundamental appeal and broader application range than correlations [1]. Yun Wook Hwang, Min Soo Kim (2006) in this paper R-134a used for investigate the pressure drop characteristics in micro tubes. The test tube diameter was circular stainless steel tube with inner diameters of 0.244, 0.430, and 0.792 mm. Although some of the existing studies reported the early flow transition at the Reynolds number of less than 1000, it was not found in the single-phase flow pressure drop tests. The conventional theory predicted the friction factors well within an absolute average deviation of 8.9%. The two-phase flow pressure drop increased with increasing mass flux, increasing quality, and decreasing tube diameter. The existing correlations failed to predict the two-phase friction multipliers in the micro tubes of this study. A new correlation to predict the two-phase flow pressure drop in micro tubes was developed in the form of the Lockhart Martinelli correlation. It includes the effect of the tube diameter, surface tension effect, and the effect of the Reynolds number on the two-phase flow pressure drop in micro tubes. The new correlation developed in this study predicted the experimental data within an absolute average deviation of 8.1%. [2] Figure: 1 COP vs. Refrigerant Charge Amount Sub cooling Figure: 2 Degree of Superheating and V/s. Refrigerant Charge Amount Rin Yun, Yunho Hwang, Reinhard Radermacher, Rebeka Zecirovic (2006) in this study the seasonal performance of a residential air conditioning system having either a fin-and-tube condenser or a micro channel condenser is experimentally investigated. Micro channel heat exchangers offer a higher volumetric heat exchange capacity and a reduced refrigerant charge amount. However, the operating

characteristics and the seasonal energy efficiency ratio (SEER) of the residential air conditioning system using a micro channel condenser have not been well known. For this investigation, a commercially available 7 kw capacity residential air conditioning system having a fin-and-tube condenser served as the base system. After testing the base unit with the fin-and-tube condenser, the condenser was replaced by a micro channel heat exchanger with the same face area under identical test conditions. The test results show that the system with a micro channel heat exchanger has a reduced refrigerant charge amount of 10%, the coefficient of performance increased by 6% to 10%, and the SEER increased by 7% as compared with those of the base system. Moreover, the condensing pressure of the system is decreased by 100 kpa and the pressure drop across the condenser is decreased by 84%. The micro channel heat exchanger enhances the SEER of the residential air conditioning system by providing better heat transfers at reduced pressure drops. [3] Pega Hrnjak, Andy D. Litch (2008) this paper presents a prototype ammonia chiller with an air-cooled Condenser and plate evaporators are used for experimental results. The main objectives were compactness of the system and charge reduction. In the chiller Two aluminum condensers were evaluated: one a single serpentine macro channel tube (Dh ¼ 4.06 mm) and other with a parallel tube arrangement between headers and micro channel tubes (hydraulic diameter Dh ¼ 0.7mm). The charge is reduced to 20 g/kw (2.5 oz/ton).the performances of condense and chillers are compared based on various criteria to other available ammonia chillers. From the experimental data taken, the micro channel parallel Flow condenser appears to outperform the macro channel Serpentine condenser. The overall heat transfer coefficient for a given face velocity is 60 80% higher than for the serpentine Condenser; and the charge is an average of 53% less. Existing air-cooled ammonia chillers could greatly benefit from micro channel technology. The charge would be significantly reduced while maintaining the same heat transfer capability. In addition, the external volume of the chiller could be reduced because the external volume of a micro channel design is small. It can be about 30% of the volume of the standard round tube, plate fin condenser. [4] Figure: 3 overall heat transfer coefficients in (a) serpentine and (b) Microchannel parallel flow condenser based on air Side surface area Figure: 4 air side heat transfer results (a) serpentine and (b) Microchannel condenser Chang Yong Park, Pega Hrnjak (2008)This study investigates effects of two condensers (micro channel and round tube) on the performance of R410a residential air conditioning system was

experimentally examined. In various conditions two systems were operated in separate environmental chamber and their performance was measured. Both cooling capacity and COP of the system with micro channel condenser were higher than those for the round tube condenser in all test conditions. A numerical model for the micro channel condenser simulated with consideration given to the refrigerant distribution in the headers and non uniform air distribution at the face of the condenser. This result showed that refrigerant distribution and effect of the air was not a significant parameter in predicting the capacity of the micro channel condenser experimentally examined in the study. These two condensers had almost identical frontal area and depth because the purpose of this study was to measure performance improvement using the micro channel condenser had an almost identical package volume as the round-tube condenser. The COP of the system with the micro channel condenser was 13.1% higher than that with round tube condenser, using a micro channel condenser resulted in a 2.5 C lower conditioning temperature and decreased the refrigerants pressure drop from166kpa in round tube condenser to 57kpa in the micro channel condenser. The refrigerant charge amount for the system with the micro channel condenser was 9.2% smaller than that with the round tube condenser even though the micro channel condenser showed better heat transfer performance of capacity and system COP than the round tube condenser. [5] ZHANG Huiyong, LI Junming, LI Hongqi(2010) This paper introduces a microchannel condenser for domestic refrigerators with a theoretical model to evaluate its performance. The model was used to obtain the optimal design parameters for different numbers of tubes and tube lengths. Compared with the original condenser, the present optimal design parameters can reduce the total metal mass by 48.6% for the two wall two side design and by 26% for the two wall one side design. [6] Milnes P. David, Josef Miler, Julie E. Steinbrenner, Yizhang Yang, Maxat Touzelbaev, Kenneth E. Goodson(2011) In the present work we design, model and experimentally characterize a twophase vapor venting parallel micro channel heat exchanger capped with a 220 nm pore, hydrophobic PTFE membrane that vents the vapor phase into separate vapor transport channels. We compare the performances of a traditional no venting heat exchanger and the vapor-separating version operating at heat fluxes of up to 820 kw/m2 and water mass fluxes of between 102 and 420 kg/s m2. We find ~60% improvement in the normalized pressure drop and up to 4.4 C reduction in the average substrate temperature between the control and vapor venting device under similar operating conditions. [7] Guan-Qiu Li, Zan Wu, Wei Li, Zhi-Ke Wang, Xu Wang, Hong-Xia Li, Shi-Chune Yao (2012) An experimental investigation was performed for single-phase flow and condensation characteristics inside five micro-fin tubes with same outer diameter 5mm and helix angle 18 0 data are for mass fluxes ranging from about 200 to 650kg/m 2 s.the nominal saturation temperature is 320k, with inlet and outlet qualities of 0.8 and 0.1, respectively. The results suggest that tube 4 has the highest condensation heat transfer coefficient and also the highest condensation pressure drop penalty, while tube 5 has the highest enhancement ratio due to its lowest pressure drop penalty and intermediate heat transfer coefficient. Condensation heat transfer coefficient flattens out gradually as G decreases when G<400kg/m 2 s for tube 2 and tube 4. This nonlinear mass-flux effect may be explained by the complex interactions between micro fins and fluid, including liquid drainage by surface tension and interfacial turbulence. In addition, the experimental data was analyzed using seven existing pressure drop correlations and four heat transfer models to verify their respective accuracies. [8] G.B. Ribeiro, J.R. Barbosa Jr., A.T. Prata (2012) in this paper the thermal-hydraulic performance of micro channel condensers with open-cell metal foams to enhance the air-side heat transfer is investigated. Three different copper metal foam structures with distinct pore densities (10 and 20 PPI) and porosities (0.893 and 0.947) were tested. A conventional condenser surface, with copper plain fins, was also tested for

performance comparison purposes. The experiments were performed at a condensing temperature of 45 o C. The air-side flow rate ranged from 1.4 x 10-3 to 3.3 x 10-3 m 3 /s (giving face velocities in the range of 2.1-4.9 m/s). The heat transfer rate, the overall thermal conductance, power were calculated as part of the analysis. [9] Figure: 5 Illustration of a metal foam condenser [9] Gopinath R. Warrier z, Chang-Jin Kim, Y. SungtaekJu (2013) was analyzed a novel two-phase micro channel cooling device that incorporates perforated side walls for potential use as an embedded thermal management solution for high heat flux semiconductor devices. A dense array of perforated side walls separate alternating liquid and vapor micro channels, allowing the vapor generated through evaporation of liquid supplied through micro-perforations to flow only in the dedicated vapor channels. By separating the liquid and vapor flows, these perspiring sidewalls enable us to circumvent flow instabilities and other challenges associated with conventional two-phase micro channel cooling while at the same time effectively take advantage of the large extended surface areas available in high-aspect-ratio micro channels. One implementation of our design is parametrically analyzed using finite element modeling, demonstrating the potential of our proposed device for handling high heat flux electronic and optoelectronic semiconductor devices. [10] Figure: 6 A schematic of the proposed embedded evaporative cooling device featuring phase-separated micro channels with perforated side walls [10]

Summary Author name/ Objective Parameter used Conclusion year Weilin Experiment 21 Parallel 213 713µm Pressure drop increases appreciably upon Qu & conducted to Micro channels. commencement of boiling in micro Issam measure pressure Mudawar [2003] Yun Wook Hwang & Min Soo Kim [2006] Rin Yun et al [2006] Pega Hrnjak& Andy D. Litch [2008] Chang Yong Park Pega Hrnjak [2008] & Milnes P. David et al [2011] drop in a two phase micro channel heat sink. Investigation of pressure drop in micro tubes and correlation development Comparison of performance of a residential airconditioning system using Micro channel and finand-tube heat exchanger This paper presents experimental results from a prototype ammonia chiller with an air-cooled Condenser and a plate evaporator. The effect of different type of condensers on the performance of R410A residential air conditioning systems were investigated in this study. Hydraulic and thermal characteristics of a vapor venting two- di = 0.244,0.430,0.792mm Re<1000 a fin-and-tube condenser or a micro channel condenser, 7 kw capacity micro channel tubes (hydraulic diameter Dh ¼ 0.7 mm), single serpentine macro channel tube (Dh ¼ 4.06 mm The effect of different type of condensers on the performance of R410A residential air conditioning systems were investigated in this study. two-phase vapor venting parallel micro channel heat exchanger capped with a 220 nm pore, channels. At both moderate and high heat fluxes, the flow oscillates between the slug and annular patterns upstream and is predominantly annular downstream. Better accuracy is achieved using correlations specifically developed for mini/micro-channels. Two phase flow pressure drop increase with increasing quality, increasing mass flux and decreasing tube diameter reduced refrigerant charge amount of 10%, the coefficient of performance increased by 6% to 10%, and the SEER increased by 7% The overall heat transfer coefficient for given face velocity is 60 80% higher than for the serpentine condenser; and the charge is an average of 53% less. COP and cooling capacity of the system with the micro channel condenser were higher than those for the round-tube condenser in all test conditions. We find~60% improvement in the normalized pressure drop and up to 4.4 o C reduction in the average substrate temperature between the control and

Guan- Qiu Li et al[2012] phase channel exchanger Micro heat Experimental investigation of condensation in micro fin tubes of different geometries heat fluxes of up to 820 kw/m2and water mass fluxes of between 102 and 420 kg/s m2 5 tubes each 5mm dia. and helix angle 18 0,mass fluxes ranging from 200-650 kg/m 2 s Nominal saturation temperature 320 k Vapor venting device under similar operating conditions. It observes that tube 4 has the highest condensation heat transfer coefficient and also the highest condensation pressure drop penalty. While Tube5 has the highest enhancement ratio due to its lowest pressure drop penalty and intermediate heat transfer coefficient. G.B. Ribeiro et al [2012] Gopinath R. Warrier z, Chang- Jin Kim, Y. Sungtaek Ju[2013] Performance analysis of micro channel condenser with metal foams on the air side. analysis a novel two-phase micro channel cooling device that incorporates perforated side walls for potential use. Copper metal with distinct pore densities 10 and 20 PPI& porosities (0.893 & 0.947) R-600a Air flow rate : 1.4 10-3 to 3.3 10-3 two different micro-pore diameters (1 and 2 µm) and two different contact angles (5 0 and 10 0 ). For a fixed wall superheat of 7 K The air-side pressure drop is directly proportional to the pore density and inversely proportional to the metal foam porosity. And for a fixed pumping power, the overall thermal conductances of the metal foam condensers were lower than that of a plain fin condenser with similar characteristics. When pore diameter, increasing the contact angle decrease in the effective evaporation heat transfer coefficient. And for a given contact angle, increasing the pore-diameter results in a decrease in the evaporation heat transfer coefficient. 3. Conclusions The above literature review present that in many industries are actively investigating the use of micro channel tubes for many other heat transfer application in refrigerators, condensing units, and household air conditioning. A micro channel condenser consists of headers, Fins and the aluminum micro channel tubes. The goal of this paper is to explore the use of micro channel tube technology in the development of heat exchanger and to further utilize the properties of the refrigerant and advantages of the micro channel tube to reduce charge extruded aluminum multi port micro channel tubing is a technology that has become widely used as the condenser in automotive air conditioning. Micro channel condenser improves COP, heat transfer rate, pressure drop, condenser capacity and evaporator capacity. Nomenclature M Mach number P c p d E K Kn Ks pressure drop (kpa) Specific heat Diameter Activation energy Thermal conductivity Knudsen number Height of roughness P Po R Re T t Pressure [Pa] Poiseuille number Universal gas constant Reynolds number Temperature Time, s

U Velocity, m/s x, y, z Cartesian coordinates Re Reynolds number t Thickness d h Hydraulic diameter of the tube, m d m Mean inner diameter, m d o Outside diameter of the tube, m f Friction factor G Mass flux, kg/ (m 2 s) g Gravitational acceleration, m/s 2 h Heat transfer coefficient/(m 2 K) Nu Nusselt number m Mass flow rate, kg/s Pr Prandtl number Pore density [PPI] p D A Area [m 2 ] Greek symbols α Apex angle of the fin, degree β Helix angle, in degree η Dimensionless radius θ Dimensionless temperature λ Drag coefficient μ Dynamic viscosity (Pa s) ν Kinematic viscosity ξ Height to width ratio ρ Density (kg/m 3 ) τ Shearing stress at a wall ϕ Energy dissipation References [1] Weilin Qu, Issam Mudawar, Measurement and prediction of pressure drop in two-phase micro-channel heat sinks, International Journal of Heat and Mass Transfer 46 (2003) 2737 2753. [2] Yun Wook Hwang, Min Soo Kim, The pressure drop in micro tubes and the correlation development, International Journal of Heat and Mass Transfer 49 (2006) 1804 1812. [3] Rin Yun, Yunho Hwang, Reinhard Radermacher, Rebeka Zecirovic, Comparison of Performance of a Residential Air-Conditioning System Using Micro channel and Fin and-tube Heat Exchanger, International Refrigeration and Air Conditioning Conference, (2006) Paper 752. [4] Pega Hrnjak, Andy D. Litch, Micro channel heat exchangers for charge minimization in air-cooled ammonia condensers and chillers, 31(2008 ) 658 668. [5] Chang Yong Park, Pega Hrnjak, Experimental and numerical study on micro channel and round-tube condensers in a R410A residential air-conditioning system, International Journal of refrigeration 31 (2008) 822-831. [6] ZHANG Huiyong, LI Junming, LI Hongqi(2010) Numerical Simulations of a Micro-Channel Wall-Tube Condenser for Domestic Refrigerators. 4 August 2010 [7] Milnes P. David, Josef Miler, Julie E. Steinbrenner a, Yizhang Yang, Maxat Touzelbaev, Kenneth E. Goodson. Hydraulic and thermal characteristics of a vapor venting two-phase micro channel heat exchanger. International Journal of Heat and Mass Transfer 54 (2011) 5504 5516. [8] Guan-Qiu Li, Zan Wu, Wei Li, Zhi-Ke Wang, Xu Wang, Hong-Xia Li, Shi-Chune Yao, Experimental investigation of condensation in micro-fin tubes of different geometries Experimental Thermal and Fluid Science 37 (2012) 19 28. [9] G.B. Ribeiro, J.R. Barbosa Jr., A.T. Prata, Performance of micro channel condensers with metal foams on the air-side Application in small-scale refrigeration systems, 36 (2012)152-160. [10] Gopinath R. Warrier z, Chang-Jin Kim, Y. Sungtaek Ju Micro channel cooling device with perforated side walls: Design and Modeling, International Journal of Heat and Mass Transfer 68 (2013) 174 183