631RF Amp Power Supply

Similar documents
Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

IR ILLUMINATORS FOR DISCREET NIGHT SURVEILLANCE

Accessories. Desk Top Controls

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Egress Devices for Code Compliant Access-Controlled Egress Doors

Exit Switches SECURITY DOOR CONTROLS. 400 Series 410 & 420 Series. Finishes. Finishes. Options. Options. Specifications.

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Power Supplies. Overview

SP-1000X. Panic Device Power Controller Installation Guide. Rev

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for models:

/ How To Order

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Exit Check Integrated Delayed Egress Locks

Installation Guide for models:

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

Commercial and Light Industrial Fire Alarm Control Panel

Specification/ Data Sheet

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

MODEL B2 INSTALLATION MANUAL

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Series. Access Power Controllers. Installation Guide

SECTION AUTOMATIC TRANSFER SWITCHES

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireNET Plus Wiring Instructions

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

CALL YOUR SALES CONSULTANT TODAY,

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Model 17A00 Expansion Enclosure

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

RELEASE DEVICE CONTROLS

Intelligent Single Loop Fire Alarm Control Panel

EVO192 v3.0 Fire and Burglary What s New

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

DS7400Xi Addressable Control/ Communicator

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

Code Compliance. Selected Exit Check models are available to comply with one or more codes listed below. See Operation on page 3.

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Public Safety DAS Annunciator Panel

Optional cable and connectors SELECTRIC TM PRO

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Rack Mount Series Installation Guide

Installation, Operating and Maintenance Manual

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Access Power Controllers with Power Supplies

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Conventional Releasing Control Panel

Model A1600 Series Annunciator

Intelligent 2 & 4 Loop Fire Alarm Control Panels

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Excel-EN Conventional Fire Control Panel

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

good things in small packages

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

Remote NAC Power Supply D7038

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

SECTION LOW VOLTAGE LIGHTING CONTROLS

ESSEX ENGINEERING CORPORATION

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

AL800ULADA. NAC Power Extender. Installation Guide

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

20 Light Remote Annunciator

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Transcription:

631RF - 1.5 Amp Power Supply Modular Access Control Power Supply Field Selectable 12VDC or 24VDC Output - Standard Dual 12VDC and 24VDC Output - Optional Quality, Performance and Versatility The SDC 631RF Power Supplies have been developed specifically to support electric locks and access controls. The high performance, heavy-duty circuitry is ideal for inductive loads and multidoor applications. The modular design is built around several different application control modules to meet your specific needs for virtually any electric lock system. SDC power supplies are designed to provide a well organized installation for individual or multi-door systems that may include locking devices, access controls, station controls and consoles for remote control, annunciation and fire/life safety system interface. Manufactured and Tested to Rigorous Standards SDC 600 Series power supplies are manufactured according to ISO 9001 certified quality standards. Tests are conducted according to tough UL 1481 criteria for specific use with access controls, fire and burglary applications. Modular Design Ten different, individually fused door control modules are available for virtually any application. Time delays, latching relays and multiple station circuit breaker modules are available for custom configuration in the field or at the factory. DIP Switch Select System Operation Specification of the UR Universal Access Hardware Controller provides for six standard DIP switch selectable system and mantrap variations for multiple door systems. Features SIA Security Industry Finest ISC Expo Filtered and Regulated The output filtering stabilizes the DC output voltage and eliminates AC line noise. The solid state regulator maintains the selected output voltage at 12VDC or 24VDC regardless of the output load changes, including battery charging. The AC input is protected by a fuse and secondary DC output is protected by auto resetting poly fuse. 250 ma Battery Charger Output A separate PTC protected, battery charger output provides 13.5VDC or 27VDC. Low Battery Disconnect Batteries are automatically disconnected from the secondary output circuit when the voltage decreases below 70%. This ensures batteries are capable of recharging. LED System Status Indicator Amber - AC and DC voltages are OK Green - No DC output Red - No AC input, powered by batteries ALVY - Access Control Systems Unit URTZ - Fire and Burglar Alarm Power Supply SYSW - Releasing Device Accessory Value Added Features Isolated Charging Circuit While the charging output is 13.5VDC or 27VDC, the secondary output is unaffected and precisely maintained at the selected 12 or 24VDC. This ensures system components are powered by their specified voltage. The secondary output current is maintained at the full 1.5 Amp capacity and is not de-rated when charging batteries. Class 2 Outputs Where permitted by code, conduit is not required when using Class 2 outputs. Emergency Release The Fire/Life Safety emergency release input is standard on all SDC power supplies. Field Selectable 12 or 24VDC The output is field selectable for 12 or 24VDC output. MADE IN THE USA Large Heavy Gauge Enclosure Model 631RFA is housed in a 16 gauge, 16"W x 14"H x 6.5"D cabinet large enough to accommodate several additional modules and six 7 Amp hour batteries with plenty of room for wiring. SECURITY DOOR CONTROLS www.sdcsecurity.com E-mail: service@sdcsecurity.com

Ordering Information 631RF 631RFA Options 1.5 Amp Power Supply 11.25"W x 11.25"H x 3.5"D 1.5 Amp Power Supply 16"W x 14"H x 6.5"D PTC4-075 Four 0.75 Amp auto resetting PTC protected outputs. 2 modules provide 8 outputs. Combined output may not exceed 1.5 Amp. FB-4 Four fuse protected outputs for precisely calculated protection. 2 modules provide 8 outputs. MR Manual reset fire alarm release PC 6 foot Power Cord. KL Key locked cover. 14-2 7-day skip-a-day timer. PS-1 On-Off Push switch inside cabinet. 631RFA only. PS-1A On-Off push switch on cover. 230V 220/230VAC, 50/60 Hz input. (Not UL Listed) Dual 12VDC and 24VDC Outputs (optional) 12VR 12VDC Regulated and Filtered Output Module With the power supply output set at 24VDC for locking devices and components, the addition of the 12VR provides a separate 12VDC, 500 ma output for 12VDC access controls and components. Total combined load may not exceed 1.5 Amps. : 24VDC Output: 500 ma @ 12VDC Standby Power SDC power supplies equipped with batteries provide continuous operation of access controls, locking devices and peripheral components during a power failure. See Table 2 & 3 to determine battery requirements for standby power. RB12V4 12VDC, 4 Amp Hour Battery 631RF capacity, 4 maximum RB12V7 12VDC, 7 Amp Hour Battery 631RFA capacity, 6 maximum Electrical Specifications : 115VAC @ 800mA, 50/60 Hz, Fused (220/230VAC 50/60 Hz optional, not UL Listed) Selectable Secondary Output: 12VDC or 24VDC @ 1.5 Amp, poly fuse protected, Class 2 Battery Charger Output: 250mA @ 13.5 or 27VDC, PTC protected Mechanical Specifications 631RF: 11.25"W x 11.25"H x 3.5"D (285.7 x 285.7 x 88.9mm) Material: Steel, 20 Ga., (.912mm) 631RFA: 16"W x 14"H x 6.5"D (406.4 x 355.6 x 165.1mm) Material: Steel, 16 Ga., (1.52mm) PTC4 12VR 631RF x PC x PTC4-075 x 2 RB12V4 631RFA x UR4A x 4 RB12V7 Table 1: Control Module Capacity Power Supply ACM-1 CR CR-4 PTC4 FB-4 LR PB TD UR 631RF 631RFA NA 2 1 2 2 2 2 2 NA 4 6 2 2 2 6 2 6 1 How to Order Specify model, options, modules and batteries. 631RF x KL/PS-1 x 2 PTC4-075 x 2 RB12V4 631RFA x KL x CR4 x 4 RB12V7 + C Fire/Emergency Release S O /Off C Closed Dry contact Min. Contact Rating: 100 ma Table 2: 12VDC Standby Power 4.5 Ah Batteries 1 2 3 4 Amp Hours 4.5Ah 9Ah 13.5Ah 18Ah 0.25 17 33 49 65 0.50 8 15 23 31 1.00 3 6 9 12 1.50 2 4 7 10 7 Ah Batteries 1 2 3 4 5 6 7 8 9 10 Amp Hours 7Ah 14Ah 21Ah 28Ah 35Ah 42Ah 49Ah 56Ah 63Ah 70Ah 1.00 5.7 14 20 30 33 41 48 55 62 69 1.50 3.6 8 13 18 23 29 33 37 39 4 Table 3: 24VDC Standby Power 4.5 Ah Batteries 2 4 Amp Hours 4.5Ah 9Ah 0.25 17 33 0.50 8 15 1.00 3 6 1.50 2 4 7 Ah Batteries 2 4 6 8 10 Amp Hours 7Ah 14Ah 21Ah 28Ah 35Ah 1.00 5.6 14 20 30 33 1.50 3.6 8 13 18 23

Access Hardware Controller Selectable Output Modes UR-2A Specifications UR-2A Two Station Controller UR-4A Four Station Controller The UR series is a microprocessor based controller that provides six different, field selectable application modes for two, three or four stations. The controller installs in 600 series power supplies. Or, individual access hardware controllers may be mounted in remote junction boxes and powered by a single power supply. Interface and Centralized Wiring The Access Hardware Controller provides complete system interface capability and centralized wiring of all components, including: access controls, electric locks, peripheral equipment and monitoring contacts. Reduced Components and Engineering Applications that require several individual relays may be costly and complicated, requiring additional engineering time to produce the proper system logic. The UR eliminates the need for multiple or different relays. All system logic is reduced to one controller. Conventional Relay Latching Relay (pulse on, pulse off) Latch individual station or all stations Time Delay Relay 1-35 seconds *Dual, Latching & Time Delay Relay Mantrap - All doors normally locked Interlock - All doors normally unlocked *Primary input triggers the Time Delay Auxiliary input triggers latch function The relay mode may be different per individual station. When mantrap or interlock mode is selected, all outputs operate the same. Documentation Several access control and mantrap system wire diagrams are provided for common applications. SIA Security Industry Finest ISC Expo Voltage: 12 or 24VDC +/- 10% Current: 280mA, at rest 350mA, operating Trigger s: N.O. Dry, Optically Isolated (2) s per output, (4) Total plus (4) Auxiliary inputs Outputs: 2 Fused SPDT Dry, 5 Amp @ 30VDC 2 Non-fused, SPDT Dry, 1 Amp @ 30VDC UR-4A Specifications Voltage: 12 or 24VDC +/- 10% Current: 350mA, at rest 430mA, operating Trigger s: N.O. Dry Optically Isolated (2) s per output, (8) Total plus (4) Auxiliary inputs Outputs: 4 Fused SPDT Dry, 5 Amp @ 30VDC 4 Non-fused, SPDT Dry,1 Amp @ 30VDC 7"L x 5"W x 1.75"H (177.8 x 127 x 44.5mm) Station A Station B Station C Station D ( DOOR A ) ( DOOR B ) ( DOOR C ) ( DOOR D ) Output Output Output Output MAIN BOARD + - c MONITOR MONITOR MONITOR MONITOR A5 A6 A7 A8 A9 A10 B5 B6 B7 B8 B9 B10 C5 C6 C7 C8 C9 C10 D5 D6 D7 D8 D9 D10 + - The UR4A is capable of providing the logic of 8 relays. and output designations shown are typical and may vary per application requirements. DIP switch for field programming A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 D1 D2 D3 D4 E1 E2 E3 E4 E5 E6 E7 E8 DIP SWITCH 1 2345678 ON OFF ACCESS CONTROL DPS ACCESS DPS ACCESS DPS ACCESS DPS OR CONTROL OR CONTROL OR CONTROL OR UNLOCK LOCK ALL ALL Auxiliary s A, B, C, D Station A Station B Station C Station D

www.sdcsecurity.com E-mail: service@sdcsecurity.com Door Control Modules Door control relay modules ensure compatibility of access hardware components and simplify system installation and troubleshooting. Different modules may be specified for one power supply. See Table 1 to determine the module capacity of the power supply. The isolated relay design allows small gauge cable runs of 20 gauge wire up to 1000 feet from the trigger device to the module. See Table 4 to determine the wire gauge for electric locks. ACM-1 Access Control Interface Module Voltage: 12 or 24VDC Current: 45mA Eight Trigger s: Four - N.C. and Four - N.O. Dry SPDT, 5 Amps @ 30VDC Auxiliary Output: SPDT Dry, 5 Amps @ 30VDC 4.25"W x 3.75"H (108mm x 111mm) LR Latching Relay Module Voltage: Specify 12 or 24VDC Current: 35mA Trigger input: Two position, Center off, N.O., Dry, Momentary pulse to latch on and off TD Time Delay Relay Module Voltage: 12 or 24VDC Current: 35mA Dry Trigger s: One - N.O. Dry, One - N.C. Dry Wet Trigger : Normally Off The trigger voltage must be the same as the lock and supply voltage. Anti-Tailgate/Reset : N.O. Dry When the door opens the magnetic contact closes, resetting the timer. The door locks when closed. Auxiliary Output: Non-fused SPDT Dry, 5 Amps @ 30VDC CR Control Relay Module Voltage: Specify 12 or 24VDC Current: 35mA Dry Trigger : One N.O. Dry Wet Trigger : Normally Off Trigger Voltage must be the same as the relay and supply voltage, AC or DC Auxiliary Output: Non-fused SPDT Dry, 5 Amps @ 30 VDC CR4 Four Station Relay Module Voltage: 12 or 24VDC Current: 120mA Trigger s: Four N.O. Dry Lock Outputs: Four, Fused SPDT Dry, 2 Amps @ 30VDC Auxiliary Outputs: Four, Non-fused, SPDT Dry, 2 Amps @ 30VDC 6"W x 3.25"H (153mm x 83mm) PB-8 8 Amp Power Booster Voltage: Current: Trigger : Lock Output: 24VDC 85mA N.O. Dry SPDT, 24VDC 1 Amp Continuous 8 Amps Surge PB-16 16 Amp Power Booster Voltage: Current: Trigger : Lock Output: 24VDC 85mA N.O. Dry Contact SPDT, 24VDC 1 Amp Continuous 16 Amps Surge Table 4: Wire Gauge Chart (AWG) Distance in feet for 2 conductors from power source to the locking device. AMPS 0.25 0.50 0.75 1.00 1.50 2.00 2.50 3.00 3.50 25 50 75 100 150 200 250 300 400 500 25 50 75 100 150 200 250 300 400 500 1000 18 18 18 18 18 18 16 16 14 14 18 18 18 18 18 18 18 18 18 16 16 18 18 18 18 16 14 14 18 18 18 18 18 18 18 16 16 14 18 18 18 16 14 14 18 18 18 18 18 16 16 14 14 18 18 16 14 14 18 18 18 18 16 16 14 14 18 18 16 14 18 18 18 16 16 14 18 16 14 Minimum Wire Gauge 18 18 16 16 14 Minimum Wire Gauge 18 16 for 12V AC / DC 18 18 16 14 for 24V AC / DC 16 14 18 16 14 14 16 18 16 14 SECURITY DOOR CONTROLS P.O. Box 6219, Westlake Village, CA 91359-6219 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 (800) 413-8783 Fax: (805) 494-8861 2004 Security Door Controls Printed in the U.S.A. LIT-631RFPwr Supply_0104 4M CR

BarcodesInc 200 West Monroe Street Chicago, Illinois 60606 Phone: 1-800-351-9962 Fax: 1-312-212-1800 www.barcodesinc.com About BarcodesInc BRANDS Who We Are BarcodesInc is North America's leading provider of p We Owe Our Success To You Why Choose BarcodesInc? Dedicated Account Our Account Managers will not compromise when it comes to providing you top-notch service. Your Account Manager is the primary point of contact for your business and makes it a priority to get to know you, your company and all your needs. Highly-Trained Technical Support Our technical staff has the broadest knowledge and every significant certification in the industry. One of our friendly experts is always available to suggest products and solutions for any situation. Incredible Value Our purchasing power means big savings for you. Whatever your project, our team will work hard to deliver a solution that fits your budget. Largest Inventory in the Industry and Same-Day Shipping Whatever your barcoding, mobile computing, or printing needs, we will fill your order and ship it the same Premier Access to Top Manufacturers BarcodesInc maintains strong strategic partnerships with the leading manufacturers in barcoding, mobile computing, printing and RFID. Responsive Customer Service Every phone call and email is responded to promptly, completely and accurately by our customer service Easy Returns Damaged, defective or incorrectly ordered goods may be returned without hassle. AND MORE BarcodesInc 200 West Monroe Street, Chicago, IL 60606 T: 1-800-351-9962 F: 1-312-212-1800 www.barcodesinc.com