ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

Similar documents
Installation And commissioning manual. Series S Double Beam 1/16

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

English. Series. Installation and Use Manual

FSLIMPRO

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

CONFIGURATION OF THE OPTICALS

INDEX. Installation recommendation

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

DUAL OPTIC. Installation manual

INDEX. Installation recommendation

INDEX. Installation recommendation

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Twin Photobeam Detectors Manual

INDICE. Installation recommendation

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Description. Optex Incorporated

Quadruple-beam photoelectric detector

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

"Pegaso" wireless alarm system

Movement Detector GJD 300

Long-Range Barrier Sensors

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Infrared Single Light Barrier. Mounting Instructions DO560

DD205RF/TX Detector Installation Sheet

Photoelectric Beam Detector

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-Tect 2 GJD300 Quad PIR Movement Detector

Installation and Operation Manual

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

WM3000 WIRELESS MODULES

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Light Walls HB-T001Q3 HB-T001R3

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

Optical Beam Smoke Detector RK90R - RK90RS

PARVIS Safe and tranquil thanks to Parvis

Active Infrared Multi Beam Sensors

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

CAUTIONS ON INSTALLATION

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Active Infrared Multi Beam Sensors. R Series

LUX Hardwired - Installation Notes

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

1. Quick start-up guide

General Purpose IO Technical Manual

Increased safety and reducing energy consumption with the motion control RPI 01

Acusensor 3. Instruction Manual

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

"Pegaso" wireless alarm system D.I.Y. wireless kit

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Table of Contents. 1. Mounting Tips... 2

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

English. Italiano. Português. Françias. Español

Passive Infrared Motion Detector 5420/90P. Installation Instructions

INFRARED MODULATED BARRIERS

Laser Distance Sensor Type M Analog-Output

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

TrueAlarm Analog Sensing

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Advanced DIGITAL Wired PIR Motion Detector

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

User manual INFRARED REMOTE CONTROLLER SIR-15

UV - flame detector dual fuel burners for intermittent burner operations

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Motion Detector. Installation and Usage Guide. Need help? Visit protectamerica.com/chat

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

Safety Photo Beam UL MONITORED DEVICE

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

Ethernet General Purpose

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

AX-70TN, AX-130TN, AX-200TN AX-100TF, AX-200TF

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

An Ambient-Light-Ignoring Infrared Active Motion Detector

CATALOGUE LASER POINTERS

General Specifications

Installation Manual Premier Elite Orbit QD/DT INS483-2

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Operations Manual. Motion Detector Module Model ZS10

Analog Room Pressure Monitor RPC Series

LS800S Intruder Alarm System. Engineering Manual

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

BARRIERE & SENSORI BARRIERS & SENSORS

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Key Features. General Description

Ultrasonic Proximity Sensor

Transcription:

BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL Manuale istruzioni BST-100 Pag. 1

1 - Product Discription The BST-100 is an active indoor & outdoor infrared detector with two beams of protection. It has regulations for : Vertical axial from (+10 to 10 ), Horizontal axial from (+90 to 90 ), and for the trigger response time from 1 to 5 (See Par. 5). Cable hole Tamper button Terminal B. Led indication of signal intensity Vertical axial screw regulation Lens Trigger response time regulation Regulation connector for voltimeter Support for Horizontal regulation Alignment mirrors Front cover Front cover fixing screw 2 - Connections and Indications TRASMITTER Power + -- Output not in use Tamper output On the transmitter there is a GREEN LED indication for power. LED on indicates power present. POWER Power + -- Pag. 2 RECEIVER Alarm Trigger GOOD LEVEL ALARM Tamper output The receiver has 3 LEDs that indicate the intensity of the infrared signal received and the alarm trigger. LEVEL (red led) The more intense the luminosità the more intense the signal received from transmitter. GOOD (green led) this will light if there is a good level of transmission (at least 2,3V on the voltimeter). ALARM (red led) This will light if there is an alarm trigger. Instruction Manual BST-100

Connection terminals 1. Power input (+12Vd.c.) 2. Negative power input 3. Common (relay) 4. Normally open Dry contact relay output only for receiver 5. Normally closed 6. Tamper output 7. Tamper output Note: When the BST-100 is in normal function, the relay on the receiver is always powered. 3 - Installation precautions Outdoor installations: Due not install the BST-100 where animals, trees, bushes or other plants can interrupt the line of sight of the beams. Indoor installations: Avoid that instable objects intrupt the line of sight of the beams (curtains, furniture, etc..) Avoid mounting the unit on columns that my not be stable. Avoid mounting the unit in direct sun light or in front of a high luminosity light sources. Avoid that a receiver can, by error, receive the signal transmitted form the the wrong unit. See below: Receiver Trasmitter Receiver Receiver Trasmitter Transmitter ERROR Trasmitter CORRECT Receiver Manuale istruzioni BST-100 Pag. 3

3 - Installation procedure Wall mounting 3.1.1 Remove front cover Installation on column 3.2.1 Drill hole for the cable on the top of the column 3.1.2 Using the metal base, mark on the wall the position of the fixing holes. See below: 3.2.2 Rimove the front cover 3.1.3 Insert the connection cable that comes from the control panel. 3.2.3 Fix the metal base to the Column as shown below. Cable hole 3.1.4 Fix to the wall the metal base of the sensor. 3.2.4 See below how to fix 2 units to the same column. 3.1.5 Connect the cables to the desire terminal blocks See fig. page 2 for terminal conn. Pag. 4 Instruction Manual BST-100

4 - Alignment of the I.R. Visual test 1. Remove the front cover and power up both receiver and transmitter. 2. At a distance of about 10cm. from the alignment mirrors, check to see if the figure of the other sensor can be seen. Also check the intensity of the Red LED. The more intense the red LED the better the alignment. ITALIANO NOTE: The more precise is the alignment, the more intense will be the luminosity of the Red Led. It is best to regulate the sensor until the luminosity is at a maximum. Testing with voltmeter 1. Insert the tester cable points based on the polarity in the holes marked (+ and -) 2. Regulate the vertical and horizontal angles until the voltage is at a maximum. In anycase it must be above 2,3V. 3. On the riceiver, by using the vertical and horizontal alignment tools, you may better align the receiver and the transmitter. See below. Vertical regulation screw. Riceiver High Low For the horizontal regulation, rotate the lens body as desired. Replace the front cover and test if the active infrared barrier is functioning correctly. If not, it must be recalibrated. Manuale istruzioni BST-100 Pag. 5

5 - Regulation of trigger responce With the below figures, you may regulate the trigger 2 4 response time as desired. 1 5 3 RESPONSE TIME 1 2 3 4 5 Run (6,9m/sec.) Fast Walk (1,2m/s) Normal walk (0,7m/s) Slow Movement (0,3-0,5m/s) Slow Walk (0,1-0,3m/s) Verify the effects on the barrier based on the selected walk. If you are not satisfied with the results, change this regulation until you obtain the best possible results. 6 - Dimensions Material for fixing to support column 82mm Fixing holes 2 x 4,5mm 77mm 171mm 146mm Support Column 38 50 mm Pag. 6 Instruction Manual BST-100

7 - In case of problems Problem Cause Solution The indicator LEDs of transmittor and receiver do not light The ALARM LED does not light and the alarm trigger relay does not change state if both beams are interupted. The ALARM LED lights when both IR beams are interuped but the contol panel does not receive the trigger alarm signal. 12 Vdc. not present or defective power source present. 1-Check if the receiver is getting the barrier signal from another near by transmitter. 2-Check if both beams are interupted at the same time. 3-Check if the trigger responce time is correctly set. 1-Check the terminal connections and if there is an open or short circuit. 2-Check for error on the terminal connections. ITALIANO Check the connection cables for short circuit or bad connection. 1-Remove the transmitter that is causing the interference. 2-Make sure that both beams are interupted 3-Regulate the trigger reponse time so that the unit will function correctly. 1-Check for damaged cables 2-Check that the terminal connection are correct. ALARM trigger LED is alway light. 1-The IR beams are not aligned. 2-There is something that prevents the IR beam from arriving. 3-The sensor cover is very dirty. 1-Re-align the IR beams and test. 2-Remove any obstacales that can prevent the IR beams to arrive 3-Clean the sensor cover. False alarm signal 1-Bad cable connections to the control panel. 2-Bad 12 Vdc. Power source. 3-Obtacales present that will interup the IR beams always or only when there is wind 4-Instable coloum 5-The signal received is not strong enough. Below 2.3 V. 6-The trigger response time is not correct. 1-Check that the cables make good connection. 2-Check that the input power is okay. 3-Remove all obstacales or change the IR beam path. 4-Change or fix better the support 5-Re-align the the IR beams 6-Change the trigger response time so that the unit works correctly. 8 - Techical Characteristics MAXIMUM RANGE................ NUMBER OF BEAMS.............. OPERATING MODE................ TECHNOLOGY IR TRANSMISSION... RISPONSE TIME.................. ALARM OUTPUT................. POWER......................... CURRENT DRAIN................. FUNCTIONING TEMPERATURE...... HORIZONTAL ANGLE.............. VERTICAL ANGLE................ SENSOR MATERIAL............... WEIGHT......................... Indoor 300 mt. Outdoor 100 mt. 2 Interuption of both beams together Active Infrared From 50 to 700 Msec 30 V. 0,5 ma max. (a.c. or d.c.) From 10,5 to 18 Vd.c. 70 ma max. Da 25 C to +55 C (from 5% to 95% humidity) 180 (-90 + 90 ) 20 (-10 + 10 ) ABS Trasmitter 260 g - Riceiver 280 g Manuale istruzioni BST-100 Pag. 7

TRE i SYSTEMS S.r.l Via del Melograno N. 13-00040 Ariccia, Rome Italy Tel: +39 0697249118 Fax: +39 06 45557618 : Tre i Systems e-mail: m.tomasino@treisystems.com Website: www.treisystems.com Dispose of all waste material in appropriate garbage disposal containers. Based on the local laws, if necessary, separate the different materials before disposal. Tre i Systems is not responsable for inappropriate use or installation of the products manufactured. For any problems contact the nearest authorized Tre i Systems sales office or service center. Tre i Systems reserves the right to change or make improvments to this product without previous notice. Pag. 8 Last revision 07-02-2013 Instruction Manual BST-100