Lc~rlI. z - 510(k) Summary JUL

Similar documents
B. Company Address: N. Kendall Dr. Miami, Florida 92121

TOUBRO LIMITED ELECTRICAL & ELECTRONICS DIVISION - ELECTRONIC PRODUCTS 510(K) SUMMARY. (Per section )

February 23, Skanray Technologies Private Limited Yolanda Smith, Consultant Smith Associates 1468 Harwell Ave Crofton, Maryland 21114

E. GentleLASE Family of Laser Systems 510k Summary JL1

June 17, Skanray Technologies Pvt Ltd. c/o Ms. Yolanda Smith Regulatory Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114

TRUSTED PRECISION. A HISTORY OF INNOVATION. Valleylab FT10 Energy Platform Product Information Kit

Regulation of Alarm Remote Notification Systems

The Blood Pressure Monitor is digital upper arm monitors intended for use in measuring blood pressure and heartbeat rate with upper arm circumference

Model 900. Pulse Oximeter User s Manual

HANDHELD PULSE OXIMETER

Rutgers Environmental Health and Safety (REHS)

Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

Safety requirement compliance for Lasers

TORONTEK-B400 Pulse Oximeter. User Instructions

About this Manual. Statement. Release Date: January, 2014

Contains Nonbinding Recommendations. Draft Not for Implementation

Userʼs Manual MEDIAID INC.

Declaration of Conformity

CLEO VERSATILITY IN VITAL SIGNS

901-M / 901-ML. Pulse Oximetry System. Technical Information and Service Manual

Infinity M300 Patient Worn Monitoring

Operating manual Reusable Pulse Oximetry Sensors

ISO This is a preview - click here to buy the full publication INTERNATIONAL STANDARD. Second edition

ISO INTERNATIONAL STANDARD

Laser Safety, Utilization and Credentialing Policy

IntelliVue Cableless Measurements

OMNI Express VS VERSATILITY IN VITAL SIGNS

SPECIFICATION FOR MULTIPARAMETER MONITOR

PULSE OXIMETER PACKAGE

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 226/03)

PENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements

SureSigns VS4. Vital Signs Monitor Technical Data Sheet

TORONTEK-E400 Pulse Oximeter. User Instructions

Vitalmax 4000 CL Product Specifications

About this Manual. Statement. P/N: Release Date: August 2010 Copyright EDAN INSTRUMENTS, INC All rights reserved.

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 389/04)

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

LASER SAFETY TRAINING CATALOG LASER LASER INSTITUTE OF AMERICA S MAKE LASER SAFETY YOUR PRIORITY.

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

(Text with EEA relevance) First publication OJ EN 12322:1999/A1: Note 3 Date expired ( ) 19.8.

ISO INTERNATIONAL STANDARD

LASER SAFETY TRAINING CATALOG LASER INSTITUTE OF AMERICA S MAKE LASER SAFETY YOUR PRIORITY LASER

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

V202 HANDHELD PULSE OXIMETER OPERATING MANUAL QAB/V

5/ 5i/ 5c/ 7/ 7i/ 7c/ 5 elite/ 5i elite/ 5c elite/ 7 elite/ 7i elite/ 7c elite

ESSENTIAL REQUIREMENTS CHECK LIST

VitalCare 506N3 Series Patient Monitor Operator s Manual

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

TidalGuard HD. Handheld CO 2 / SpO 2 and CO 2 monitors. Operating Manual Rev. H (8/15)

ISO Medical electrical equipment Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment

PURPOSE OF THE PROCEDURE

(Notices) EUROPEAN COMMISSION

safety & regulatory information

OFFICIAL JOURNAL OF IN VITRO DIAGNOSTIC MEDICAL DEVICES DIRECTIVE (98/79/EC)

(Place Logo from Lab here)

25 TEXAS ADMINISTRATIVE CODE (s) Registration and Radiation Safety Requirements for Lasers

SMB/4676/R STRATEGIC BUSINESS PLAN (SBP) Title of TC TC 62: Electrical equipment in medical practice

International Iec Standard

TruSat Pulse Oximeter

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

WARNINGS AND CAUTIONS WARNING. Federal law restricts this device to sale by or on the order of a physician or other licensed practitioner.

INTERNATIONAL STANDARD

(Notices) EUROPEAN COMMISSION

MRI Patient Monitoring System (Model )

Australian/New Zealand Standard

FINAL DRAFT INTERNATIONAL STANDARD

LASER SAFETY TRAINING CATALOG LASER INSTITUTE OF AMERICA S MAKE LASER SAFETY YOUR PRIORITY LASER

West Virginia University Laser Safety Program

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

Reporting Changes to your Notified Body

Important Safety Notice

79th OREGON LEGISLATIVE ASSEMBLY Regular Session. House Bill 2386

Environmental Monitoring SmartSlot Card

PM-9000 Express Portable Patient Monitor

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

Infinity M300+ Telemetry

Rice University Laser Safety Manual

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Policy Redesign Project. Laser safety. Table of Contents

THE UNIVERSITY OF TEXAS RIO GRANDE VALLEY LASER SAFETY MANUAL. August 2016

qube mini Overview

HEALTH AND SAFETY MANUAL

This document is a preview generated by EVS

T1 BEDSIDE MONITOR GUIDELINE

UL Health Sciences Industry Case Study: Skanray Technologies

CHAPTER House Bill No. 69

DUQUESNE UNIVERSITY. Laser Safety Program

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 014/04)

CE MARKING PROCESS & NOTIFIED BODIES

INTERNATIONAL STANDARD

Instructions to User

MyKi Care Thermometer (MCT 1.0) USER MANUAL

WORLD TRADE ORGANIZATION

MODEL 3X Series User s Manual

signal extraction pulse oximeter OPERATOR S MANUAL

Operator s Manual. Avant Pulse Oximeter and Noninvasive Blood Pressure (NIBP) Monitor English

V203 HANDHELD PULSE OXIMETER & TEMPERATURE MONITOR OPERATING MANUAL

Transcription:

JUL - 2 2008 Premarket Notification 510(k) Submission-5 10(k) Summary Report No. Report No. TE20071I01 I Lc~rlI 510(k) Summary z - This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 9807.92 The Assigned 5 10O(k) Number is 1. Statement: This is a special 510(k) report for Wrist Pulse Oximeter MD300W, which is a modification device to Pulse Oximeter MD3001 (K(072825). The modification does not change intended use. And the new device has different trade name to predicate device. The applicant device, Wrist Pulse Oximeter MD300W is a modification device to Pulse Oximeter MD300I ( K 072825). The main modifications are listed below: Item MD300W MD3 001 Display type 1 types 3 types Display mode Segment LCD OLED ( black & white) ( double color) Display %SpO2, Pulse Rate Value %SpO2, Pulse Rate Value and vertical bar graph and vertical bar graph pulse amplitude pulse amplitude, Pulse I Waveform 2. Applicant Device Information Device Trade/Proprietary Name: Wrist Pulse Oximeter MD300W Device Classification Name:Oximeter Product Code: DQA Regulation Number: 870.2700 Device Class: II Review Panel: Anesthesiology Intended Use: The MD300W wrist oximeter is a portable non-invasive, spot-check, oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of adult and pediatric patient at home, and hospital ( including clinical use in internist! surgery, Anesthesia, intensive care and etc). Not for continuously monitoring. 3. Submitter Information Manufacturer Name: Beijing Choice Electronic Technology Co., Ltd.

Premarket Notification 510(k) Submission-510(k) Summary Report No.: Report No.: TE20071011 Room 1127-1128 Building B, Bailangyuan Fuxing Road, No. A36 Beijing, CHINA 100039 Contact Person of the Submission: Mr. Lei Wang East Building 3F, No.5 Shixing Street Badachu Hi-tech Zone,Shijingshan District Beijing China 100041 Phone: +86-10-88790480 x 8052 Fax:+86-10-88798860 Email: wangleigchoicemmed.com 4. Predicate Device Pulse Oximeter MD300I K-number: K072825 Product Code: DQA Intended Use: Pulse Oximeter MD300I is a portable non-invasive, spot-check, oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of adult and pediatric patient at home, and hospital ( including clinical use in internist/surgery, Anesthesia, intensive care and etc.) Not for continuously monitoring. Manufactured by: Beijing Choice Electronic Technology Co., Ltd. Room 1127-1128 Building B, Bailangyuan Fuxing Road, No. A36 Beijing, CHINA 100039 5. Device Description The applicant device of Wrist Pulse Oximeter MD300W is a wrist-worn device, which can display %SpO2, pulse rate value and vertical bar graph pulse amplitude. The applicant device consists of sensor, signal amplify unit, CPU, data display unit, data transmit unit, storage and power unit. The wrist oximeter works by applying a sensor to a pulsating arteriolar vascular bed. The sensor contains a dual light source and photo detector. The one wavelength of light source is 660 nm, which is red light; the other is 940 nm, which is ultra red light. Skin, bone, tissue, and venous vessels normally absorb a constant amount of light during systole and diastole, as blood volume increases and decreases. The ratio of light 2

Premarket Notification 510(k) Submission-510(k) Summary Report No.: Report No.: TE20071011 absorbed at systole and diastole is translated into an oxygen saturation measurement. This measurement is referred to as SpO2. The applicant device has low battery voltage alarm function and automatically power of function. The power source of the applicant device is I AAA alkaline batteries. The applicant device is not for life-supporting or life-sustaining, not for implant. The device or sensor are not sterile and the sensor does not need sterilization and the sensor is reusable but does not need re-sterilization since it is not sterile. The device is for prescription. The device does not contain drug or biological products. The device is electrically operated and the Electrical Safety Test report of BJ07013-1 and Electromagnetic Compatibility Test report of BJ7901018-1 following IEC 60601-1-2 with was conducted as the environmental test for the home use. Please see the Appendix II Electrical Safety and EMC Test. The device is software-driven and the software validation is provided in Chapter VIII Software Validation. The Performance Test reports regarding with safety and effectiveness test of the safety mechanism preventing the excess current from leading to burning injury to user (Report No. MD300W-01-001) and Low-Voltage Alarm System (Report No. MD300W-01-002) are presented in Appendix III Performance Bench Test. The Clinical Test reports following ISO 9919:2005, Medical electrical equipment Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use are conducted in Laboratory of Beijing Friendship Hospital provided in Appendix IV Clinical Test Reports. All applicable standards are listed in Chapter II Standards. The device is not kit. 6. Effectiveness and Safety Considerations Effectiveness: The Clinical Test reports following ISO 9919:2005, Medical electrical equipment - Particular requirements for the basic safety and essential performance accuracy of pulse oximeter equipment for medical use are conducted in Wulanchabu City Center Hospital provided in Attachment IV Clinical Test Reports. The accuracy of MD300W pulse oximeter equipment is compliance to the requirement, and the product is safe during the use. It can be used in the clinical environment. It is substantially equivalent to other pulse oximeter product with the same effectiveness and safety. Safety Consideration: The Performance Test reports regarding with safety and effectiveness test of the safety mechanism preventing the excess current from leading to burning injury to user (Report No. MD300C-01-001) and Low-Voltage Alarm System (Report No. 3

Premarket Notification 510(k) Submission-S510(k) Summary Report No.: Report No.: TE20071011 MD300C-01-002) are presented in Attachment III Performance Bench Test. The test results of biocompatibility of all the skin-contacting material are presented as Table IV-2 for the consideration of Biological Specifications. Please see Appendix I Biocompatibility Reports. The Biological Evaluation Tests are in compliance with the standards of ISO 10993 "Biological Evaluation of Medical Devices". The compatibility of the skin-contact component material in the finished product meets the requirement of Biocompatibility The applicant device is compliance with IEC60601-1, Medical electrical equipment - Part 1: General requirements for safety and IEC60601-1-2, Medical electrical equipment - Part 1-2: General requirements for safety -Collateral standard: Electromagnetic compatibility -. Requirements and tests 6. Substantially Equivalence Determination Comparison Analysis The applicant device has same classification information, same indications and intended use, same design principle, similar product design and specifications, sam performance effectiveness, performance safety as the predicate device. The only difference is Working time, Relative humidity. These differences are slight and do not effluence the effectiveness and safety of the device. Conclusion: The applicant device is Substantially Equivalent (SE) to the predicate device which is US legally market device. Therefore, the applicant device is determined as safe and effectiveness.

servic~e- DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service JUL - 2 2008 Mr. Lei Wang Product Manager Beijing Choice Electronic Technology Company, Limited Room 1127-1128 Building B Bailangyuan Fuxing Road #A36 Beijing CHINA 100041 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Re: K081125 Trade/Device Name: Wrist Pulse Oximeter MD300W Regulation Number: 21 CFR 870.2700 Regulation Name: Oximeter Regulatory Class: II Product Code: DQA Dated: May 28, 2008 Received: June 2, 2008 Dear Mr. Wang: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Page 2 - Mr. Wang Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, hiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure

Premarket Notification 510(k) Submission-Indication for use Report No.: Report No.: TE2007 1011 Indication For Use 510(k) Number (if known): Pending Device Name: Wrist Pulse Oximeter MD300W Indications for Use: The MD300W wrist oximeter is a portable non-invasive, spot-check, oxygen saturation of arterial hemoglobin (SpO 2 ) and pulse rate of adult and pediatric patient at home, and hospital ( including clinical use in internist/ surgery, Anesthesia, intensive care and etc). Not for continuously monitoring. Prescription Use A Over-The-Counter Use AND/OR (Part 21 CFR 801 Subpart D) (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) (Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices _51 0(k) Number: 1(,b q1tz Page I of l