2132i and 2116i Temperature and Process Indicator and Alarm Units

Similar documents
2108i Temperature/Process Indicator and Alarm Unit

122.1mm. Relay Open in alarm N/O. snubber. line. Com N/C. Closed in alarm. snubber line 2A Com snubber Open in alarm ALARM 1 N/O. Relay.

EUROTHERM ONTROLS. Alarm Unit FULLY COMPLIANT. Product data

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

MODELS 2216e, 2208e and 2204e FM TEMPERATURE ALARM UNITS

P116, P108, P104. User Manual. Piccolo Range Process Controller

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

EUROTHERM ONTROLS MODELS. Programmer/Controllers. abc

RE-PR3-E-27 3-Phase Panel Mount 27kW

2704 Controller Melt Pressure Controller

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

I/A Series 716C 1/16 DIN Temperature Controller

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

2604 Controller Melt Pressure Controller

4 & 8-POINT ANNUNCIATORS Instruction Manual

BA374C Intrinsically safe field mounting indicating temperature transmitter

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Software Version 2.01 LEVEL MONITOR MODEL 220

Module Features are-configurable, no module jumpers to set

02/11/2015

SX80 and SX90 Quickstart Guide

Series Temperature Controller Instruction Sheet

COMMANDER 150. User Guide Universal Process Indicator A1

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

eed quality electronic design USER s MANUAL

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Analog Room Pressure Monitor RPC Series

Analog Input Module IC670ALG630

TEMPERATURE CONTROLLER (STANDARD MODEL)

Process & TeMPerATUre UniversAl input DigiTAl MeTers

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160

F4 Process Controller Installation and Operation Guide

02/11/2015

FEMA ELECTRÓNICA. Panel meter for Pt100/RTD (2 and 3 wires), and thermocouples J, K, T, E, S, R, N, C,

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

SX80 and SX90 Engineering User Manual

LC2200 Level Controller Installation and Maintenance Instructions

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

C-Bus Four Channel General Input Unit Installation Instructions

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

COMMANDER 160 Wall/Pipe-mounted Universal Process Indicator. User Guide. ABB Automation

TEMPERATURE CONTROLLER

JDDT1 - Single Stage Digital Thermostat

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

/8 DIN Universal Process Indicator

UDC100 Universal Digital Controller Specifications

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

7EF/7HF/7EC/7ES Temperature Controllers

3216i, 32h8i, 3204i. User Manual. 3200i Range Process Indicators and Alarm Units

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Temperature Controllers

AO Annunciator Module

Installation Manual Tracker 221

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

ST Wiring diagram. Product description. Standard temperature controller. Order number

Two-Channel Gas Controller

RS Pro Infrared Temperature Sensor

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

UDC 700 Universal Digital Controllers and Indicator Specifications

OPTISENS TUR 2000 Technical Datasheet

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

DIGITAL INDICATOR JIR-301-M

Nov 08 PRODUCT SPECIFICATION SHEET

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

Specification , July 2015

EXTINGUISHING AGENT RELEASE MODULE

N1540 Process Indicator

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

Oxygen (O2) Single-Point Gas Detection System

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

7800 SERIES RM7888A Relay Module

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Low Temperature Zirconia Oxygen Analyzer

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

DIGITAL INDICATOR DI25

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ST Wiring diagram. Product description. Four-stage controller. Order number

Table of Contents SECTION PAGE

Model 144H. Product Data Sheet , Rev DB February Content

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Temperature Controller

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

EC2-5x2 Series Condensing Unit Controllers

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

MR3CCUHV Temperature/Defrost Control

Transcription:

2132i and 2116i Temperature and Process Indicator and Units Installing and Operating Instructions Thank you for choosing the 2132i or 2116i indicator and alarm unit. It will provide accurate measurement and display of temperature and other process variables with up to two alarm outputs for operator alert and process protection. Models 2132i/AL and 2116i/AL are Indicating alarm units which come with an alarm relay output and logic I/O fitted. Models 2132i/ND and 2116i/ND are Indicator only units which come without the alarm relay output or logic I/O fitted. s can still be configured and flashed as messages in the main display but they will not be able to operate a physical output. The indicator is supplied configured according to the ordering code given on page 5. Check the coding on the side labels to determine the configuration of your particular indicator. This indicator meets the European directives on safety and EMC. DIMENSIONS AND INSTALLATION Model 2132i 24mm (0.95in OP1 OP2 Model 2116i 48mm (1.89in 48mm (1.89in 2132 Latching ears 48mm (1.89in OP1 OP2 SP2 REM RUN HOLD 2216 D MAN 103mm (4.01in Panel retaining clips 103mm (4.01in Panel cut-out mm -0.0 +0.3 22.2-0.0 +0.6 x 45 Inch -0.0 +0.1 0.88-0.0 +0.02 x1.77 Panel cut-out 45 x 45mm -0.0 +0.6 1.77 x 1.77in -0.00 +0.02 To install the indicator Please read the safety information on pages 5 & 6 before proceeding. 1. Prepare the panel cut-out to the size shown. 2. Insert the indicator through the cut-out. 3. Spring the panel retaining clips into place. Secure the indicator in position by holding it level and pushing both retaining clips forward. 4. Peel off the protective cover from the display Unplugging the indicator The indicator can be unplugged from its sleeve by easing the latching ears outwards and pulling it forward out of the sleeve. When plugging the indicator back into its sleeve, ensure that the latching ears click into place to maintain the IP65 sealing. 10mm (0.4in Recommended minimum spacing of indicators in both sizes 38mm (1.5in Latching ears Panel retaining clips (Not to scale ELECTRICAL CONNECTIONS T/C Logic* I/O 1B 1A - + Sensor input Pt100 ma OR V- V+ 2.49Ω ack/reset Relay* Output External Relay module Model 2132i AB AA N L Neutral Line 85-264Vac 20-29Vac/dc 24 24 Low voltage supply External Relay module *Not fitted in indicator only units. Also terminals 1A and 1B not fitted in indicator only unit. OR ack/reset Model 2116i Output ratings Relay: 2A, 264Vac resistive Logic: 9Vdc, 12mA (non-isolated from sensor input. Over current protection Use a maximum 2A fuse for the indicator supply and relay output. A suitable fuse is EN60127 (type T. Wire Sizes The screw terminals accept wire sizes from 0.5 to 1.5 mm (16 to 22 AWG. Hinged covers prevent hands or metal making accidental contact with live wires. The rear terminals screws should be tightened to 0.4Nm (3.5lb in. Issue 3, Nov-98. Applies to software versions 1.3 & 1.4-1- HA026248 Logic* I/O 1A + 1B - L N AA AB V+ V- Line 85-264Vac Neutral Relay* Output T/C Pt100 Low voltage supply 24 24 2.49Ω ma 20-29Vac/dc Sensor input

OPERATION Switch on the indicator. Following a 3 second self-test sequence, you will see the display shown below. It is called the HOME display. Output 1 Output 2 OP1 OP2 The process value (PV* * See HOME display options for other possibilities TO VIEW THE DISPLAY UNITS and release quickly the or button. The display units will be flashed for 0.5sec 0.5 sec J or Display Units J Degrees Centigrade J Degrees Fahrenheit J ' Kelvin Linear inputs - no units displayed ALARM INDICATION The indicator has three internal soft alarm setpoints which can be attached to either the logic or relay outputs. OP1 will flash when an alarm attached to the logic output becomes true. (This is normally alarm 1. It will go steady when the alarm is acknowledged but still true. OP2 will flash when an alarm attached to the relay output becomes true. (This is normally alarm 2 or 3. It will go steady when the alarm is acknowledged but still true. TO ACKNOWLEDGE A NEW ALARM and together. This will also reset any latched alarms that are no longer true. In addition to the OP beacons, alarm messages are flashed in the main display. The tables below list all of the possible messages and their meaning. ALARM MESSAGES Message D5 Process s Meaning 1 is active and it is a Low alarm. 1 is active and it is a High alarm. 2 is active and it is a Low alarm. 2 is active and it is a High alarm. 3 is active and it is a Low alarm. Sensor Break: Input sensor is open circuit or high resistance. Check the sensor. In addition to the above messages, the displayed process value will flash if the input signal or the displayed value is out of range. The table above shows normal process alarms. In the event of a failure in the indicator or the sensor the following diagnostic alarm messages are provided. Diagnostic alarms Message Meaning and (Action D5 Electrically Erasable Memory Error: A parameter value has been corrupted. Contact Eurotherm Controls. <D5 Hardware error: ( Return for repair Low display range exceeded: (Check input signal High display range exceeded: (Check input signal 55 Error 1: ROM self-test fail. (Return for repair 55 Error 2: RAM self-test fail. (Return for repair 55 Error 3: Watchdog fail. (Return for repair 55 Error 4: Keyboard failure. Stuck button, or a button was pressed during power up. 55 Error 5: Input circuit failure. (Return for repair Power failure. The line voltage is too low. 0=5D If you get lost, pressing and together will return you to the HOME display. If, at any time, no key is pressed within 45 seconds, the display will always return to the HOME display. HOME DISPLAY OPTIONS Quickly press 2 secs twice 0; O0 or to return to the HOME display To prevent an Operator changing this option, see To Hide Parameters. or to select: 6 Not used by indicator 0 Not used by indicator. (Only applies to software version 1.4./. The HOME display will be blank and only alarm messages will be flashed 0; The Process value will be displayed D0 2 setpoint will be displayed and can be adjusted by or 0;D The Process value will be displayed with 2 setpoint viewed and adjusted by or TO CHANGE THE ALARM SETPOINTS (TRIP LEVELS The button steps through parameter list headings. The first list is the alarm setpoints. The other lists are shown on the next page. 0.5 sec J 1st press There are three alarm setpoints. The first character is the alarm setpoint number, the next three the alarm type, as follows: B Low alarm B High alarm If an alarm has been disabled, it will not appear in this list. 2nd press ing or displays O6 to indicate that this a list heading 2 secs O6 1 2 Next list or to change the setpoint. or to change the setpoint. 3 or to change the setpoint. and together to return to the HOME display. Issue 3, Nov-98. Applies to software versions 1.3 & 1.4-2- HA026248

PARAMETER LISTS Use these lists to change: The alarm setpoints The alarm setpoint limits User calibration. HOME X2 O0 X2 Parameter tables @ Setpoint 0 O1 1 0 HOME Home Selectable options Default setting O0 HOME display options See HOME display options on page 2 setpoints Adjustable Range Default setting * 1 setpoint Between low * 2 setpoint and high 3 setpoint setpoint limits @ Hysterisis B PV units *In place of dashes, the last three letters indicate the alarm type: = Low alarm. =High alarm 1 Setpoint limits Adjustable Range Default setting 0 Setpoint low limit Between Process As per order 0 Setpoint high limit Value min & max code O0 Input Adjustable Range Default setting O6 Input filter time in secs BD D Process value offset B units %J Cold junction temperature at the rear term ls Read-only,; mv input at the rear terminals Read-only D0 Calibration password B Calibration type. 6 (Factory 85 (User Input O6 %J,; D0 0; 6 Access /!/6/ Selecting and adjusting a parameter 1. to step across the list headings. 2. to step down the parameters within a particular list. You will eventually return to the list 0.6D D 0.6D heading. 3. to view the value of a D selected parameter. Keep pressing to decrease the value. 4. to view the value of a selected parameter. Keep pressing to increase the value. TO HIDE PARAMETERS OR MAKE THEM READ-ONLY / 0 O6!/6/ USER CALIBRATION Your indicator has been calibrated for life against known reference sources in the factory. User calibration allows you to apply offsets to compensate for sensor and other system errors. The parameter in the N0 list applies a fixed offset over the whole display range. You may also apply a 2-point calibration as follows: until you reach the O0 list until you reach the D0 parameter or to enter the password. The factory default is 3. 0 will be displayed when correct. to reach the parameter or to select 85 (6 will restore the factory calibration Apply 2-point calibration as below: Displayed Value to reach the Access Heading. or to enter the password. The factory default is 1. 0 will be displayed when the correct password has been entered. to return to the Access list header. O Use or to select O6 level. Other options are: 05 For Operator level 9 Shows the Full set of available parameters /. Gives access to configuration level. You are now in Edit level. and to select a parameter in the normal way. Example: High alarm 2 has been selected. When or is pressed, instead of displaying the parameter value, its availability to Operator is shown as follows: 65 The parameter will be alterable 05/ The parameter will be promoted into the HOME list 5 The parameter will be read-only O The parameter will be hidden. Repeat for all the parameters you wish to hide or make readonly then return to operator level: until you reach the list 05 heading until you reach!/6/!/6/ or to select 15 to return to Operator level User calibration 0.6D Low calibration point See User D Low point offset Calibration D Factory calibration 0.6D High calibration point D High point offset D Access list Used for re-configuring the indicator. 0.6D 0.6D Factory calibration Issue 3, Nov-98. Applies to software versions 1.3 & 1.4-3- HA026248

CONFIGURING THE INDICATOR Select configuration level to change: The display units The input sensor type The scaling of linear inputs The alarm configuration The passwords. To select configuration level. to reach the Access Heading. /0!/6//. N.6 N.6 Instrument list Options Meaning 9.O6 Display units J D0 Decimal places in display J J'./.......D...D.. Centigrade Fahrenheit Kelvin None (for linear inputs None One Two 65 Control type Always set to Selecting.D or 0O will convert the indicator into a controller which requires separate instructions. The parameters that follow, (6, 0D65 and 0=5, are not used by the indicator and require separate instructions. O0 Sensor Input Options Meaning O.06 Input type &D6 (D6 D6 5D6 D6.D6 6D6 D6 J thermocouple K thermocouple L thermocouple R thermocouple B thermocouple N thermocouple T thermocouple S thermocouple 0 Platinell II 56 100Ω Pt thermometer D6,; Custom input- C=st d Linear mv % Cold junction compensation 96/ OFF - Linear inputs only Automatic J, J or J external ref. N,0 Sensor break input impedance Use or to enter the password. The factory default is 1. 0 will be displayed when the correct password has been entered. Use or to select /. Use or to enter the configuration level password. The factory default is 2. 0 will be displayed when the correct password has been entered. to enter configuration level. /.0 to step across the configuration list headings. O0?O6 0 Having selected a list heading, press to select a parameter within a particular list. and to change the setting. 96/ = 1.5KΩ, O=5KΩ, OO= 15KΩ Continued in next column... Linear input scaling (-12.00 to +80.00mV mv input low Displayed value N.0D N.0D ;D ;D mv input high Displayed value low Displayed value high Configuration The list configures the three internal soft alarms and causes the appropriate alarm message to be flashed in the HOME display. list Options Meaning 1 Not used in the indicator : O / 6$ latching./ @,. The alarm is disabled Low alarm High alarm Deviation band alarm Deviation high alarm Deviation low alarm Non-latching Special - Not used Latched (manual reset / blocking./ @ No blocking Blocked until first good The above sequence is repeated for & (s 2 & 3 1DO setpoint limits O /. Limited by display range Limited by setpoint limits Relay and Logic input/output Configuration The and lists attach the three internal alarms to the relay and logic outputs. The logic can be configured as an alarm output or as an alarm acknowledge input. Relay output Options Meaning Logic output O Identity of output 5A Relay /! Logic 9. Function O! Digital output Logic only D Ack input Functions: 6,, 5D and 55 are not used by the indicator and require separate instructions O!D Digital output functions./$ No change Any combination of alarms can be attached to the logic or 5 Clear all alarms relay output. and DD 1* to select a desired alarms After a two second pause the display blinks and returns to DD DD DD5 2* 3* Sensor O!D. ing and break again will show two decimal points in those alarms that have been added to the output.= New alarm Functions: 5,,,.,., & 6,!, to 6," are not used by the indicator and need separate instructions. Sense of the output. O.: = output de-energised in alarm../5 N.: Normal Inverted *The last three letters will correspond to the alarm type set in the list. If the alarm is disabled, or or will be shown. Passwords 0 Passwords Range Default D0 Full and Edit level password B.D0 Configuration level password B D0 User calibration password B To leave Configuration level?o6@ ;D ;D N.1D N.1D to reach the?o6 display or to select @ After 2 secs the display will blink and return to the HOME display in Operator level. mv Issue 3, Nov-98. Applies to software versions 1.3 & 1.4-4- HA026248

ORDERING CODE The indicator is supplied configured according to the ordering code shown below. Model number 2132i 2116i Function Supply voltage Manual Logic I/O Relay Output Sensor input Setpoint min Setpoint max Units External relay module Input adaptor ND AL Supply voltage VH 85-264Vac VL 20-29V dc or ac XXX ENG FRA GER NED SPA SWE ITA Function Indicator only* Indicating alarm unit Manual None English French German Dutch Spanish Swedish Italian Logic I/O XX Disabled* Logic input AC ack/reset KL Keylock Non-latched alarms FH High alarm 1 FL Low alarm 1 Latched alarms HA High alarm 1 LA Low alarm 1 NW New alarm Relay Output XX Disabled* Non-latched alarms FH High alarm 2 FL Low alarm 2 AL High alarm 2 & low alarm 3 Latched alarms HA High alarm 2 LA Low alarm 2 AA High alarm 2 & low alarm 3 NW New alarm Sensor input Display range and Setpoint min & max limits Thermocouples C F J Type J -210 to 1200-340 to 2192 K Type K -200 to 1372-325 to 2500 T Type T -200 to 400-325 to 750 L Type L -200 to 900-325 to 1650 N Type N -200 to 1300-325 to 2370 R Type R -50 to 1768-58 to 3200 S Type S -50 to 1768-58 to 3200 B Type B 0 to 1820 32 to 3308 P Platinell II 0 to 1369 32 to 2496 Resistance thermometer Z Pt100-200 to 850-325 to 1562 Custom downloaded inputs C Type C -W5%Re/W26%Re (default custom sensor 0 to 2319 32 to 4200 D Type D - W3%Re/W25%Re 0 to 2399 32 to 4350 E E thermocouple -200 to 999-325 to 1830 1 Ni/Ni18%Mo 0 to 1399 32 to 2550 2 Pt20%Rh/Pt40%Rh 0 to 1870 32 to 3398 3 W/W26%Re (Engelhard 0 to 2000 32 to 3632 4 W/W26%Re (Hoskins 0 to 2010 32 to 3650 5 W5%Re/W26%Re (Engelhard 10 to 2300 50 to 4172 6 W5%Re/W26%Re(Bucose 0 to 2000 32 to 3632 7 Pt10%Rh/Pt40%/Rh 200 to 1800 392 to 3272 8 Exergen K80 I.R. Pyrometer -45 to 650-49 to 1202 Process inputs (linear M -9.99 to +80mV Scalable -999 to 9999 Y 0 to 20mA Scalable -999 to 9999 A 4 to 20mA Scalable -999 to 9999 V 0 to 10Vdc (input adapter required Scalable -999 to 9999 Input Adaptor XX None V1 0-10Vdc A1 0-20mA sense resistor (2.49Ω. 0.1% External relay module XX Not fitted R7 Fitted (Operated by the logic output Units C C F F K Kelvin X Linear input *If ND (Indicator only is specified in the function field, then XX must be entered in the Logic I/O and alarm 2 relay fields. TECHNICAL SPECIFICATION Display 4 digit, green. 10mm high characters Supply voltage High voltage unit: 100Vac -15% to 240Vac +10%, 48-62Hz. Power consumption: 5Watts maximum Low voltage unit: 24Vdc or ac -15%, +20% DC to 62Hz, Power consumption: 5Watts maximum Operating ambients 0 to 55 o C. 5 to 95%RH, non condensing Storage temperature -30 o C to +75 o C. Output ratings Relay(isolated: Maximum: 264Vac, 2A resistive. Minimum: 12Vdc, 100mA Logic I/O: 9Vdc at 18mA (non-isolated from sensor input. Can be used as alarm output or alarm acknowledge input Calibration accuracy ± 1 o C or ±0.25% of reading whichever is greater Cold junction compensation Input filtering EMC standards Safety standard Atmosphere Panel sealing >30 to 1 rejection of ambient temperature change. Uses INSTANT ACCURACY TM cold junction sensing technology to eliminate warm-up drift and respond rapidly to ambient temperature changes. Off to 999.9 seconds Generic emissions standard EN50081-2 and immunity standard EN50082-2 for industrial environments EN 61010. Installation category II. (Voltage transients on the power supply must not exceed 2.5kV. Pollution degree 2. All isolated inputs and outputs have reinforced insulation to protect against electric shock. Not suitable for use above 2000m or in explosive or corrosive atmospheres IP65 (EN 60529, or NEMA 4X SAFETY AND EMC INFORMATION Safety This indicator complies with the European Low Voltage Directive 73/23/EEC, amended by 93/68/EEC, by the application of the safety standard EN 61010. Electromagnetic compatibility This indicator conforms with the essential protection requirements of the EMC Directive 89/336/EEC, amended by 93/68/EEC, by the application of a Technical Construction File. This indicator satisfies the general requirements of the industrial environment defined in EN 50081-2 and EN 50082-2. GENERAL The information contained in these instructions is subject to change without notice. While every effort has been made to ensure the accuracy of the information, Eurotherm Controls shall not be held liable for errors contained herein. Unpacking and storage The packaging should contain the indicator, two panel retaining clips, a 2.49Ω current sense resistor and this instruction leaflet. If the packaging or the indicator are damaged, do not install the product but contact your nearest Eurotherm Controls agent. Continued on the next page Issue 3, Nov-98. Applies to software versions 1.3 & 1.4-5- HA026248

SERVICE AND REPAIR This indicator has no user serviceable parts. Contact your nearest Eurotherm Controls agent for repair. Caution: Charged capacitors Before removing the indicator from its sleeve, switch off the supply and wait two minutes to allow capacitors to discharge. Failure to observe this precaution may damage the indicator or cause some discomfort to the user. Electrostatic discharge precautions When the indicator is removed from its sleeve, it is vulnerable to damage by electrostatic discharge from someone handling the indicator. To avoid this, before handling the unplugged indicator discharge yourself to ground. Cleaning Do not use water or water based products to clean labels or they will become illegible. Isopropyl alcohol may be used to clean labels. A mild soap solution may be used to clean other exterior surfaces of the product. Safety Symbols The following safety symbols are used on the controller: Caution. Refer to the accompanying documents! Personnel Installation must be carried out by qualified personnel. Enclosure of live parts The indicator must be installed in an enclosure to prevent hands or metal tools touching parts that may be electrically live. Caution: Live sensors The logic input/output is electrically connected to the sensor input (e.g. thermocouple. In some installations the temperature sensor may become live. The indicator is designed to operate under these conditions, but you must ensure that this will not damage other equipment connected to the logic input/output and that service personnel do not touch this connection while it is live. With a live sensor, all cables, connectors and switches for connecting the sensor and non-isolated inputs and outputs must be mains rated. INTERNATIONAL SALES AND SERVICE EUROTHERM CONTROLS LTD Faraday Close, Durrington, Worthing, West Sussex BN13 3PL Telephone Sales: (01903 695888 Technical: (01903 695777 Service: (01903 695444 Fax (01903 695666 For countries not listed enquiries/orders to: Eurotherm Controls Limited, Export Dept,. Faraday Close, Durrington, Worthing, West Sussex, BN13 3PL Telephone (01903 268500 Fax (01903 265982 AUSTRALIA Eurotherm Pty. Ltd. Telephone Sydney (+61 2 9477 7022 Fax (+61 2 9477 7756 AUSTRIA Eurotherm GmbH Telephone Vienna (+43 1 798 7601 Fax (+43 1 798 7605 Telex 047 1132000 EIAUT A BELGIUM Eurotherm B.V. Telephone Antwerp (+32 3 322 3870 Fax (+32 3 321 7363 DENMARK Eurotherm A/S Telephone Copenhagen (+45 31 871622 Fax (+45 31 872124 FRANCE Eurotherm Automation SA Telephone Lyon (+33 478 664500 Fax (+33 478 352490 GERMANY Eurotherm Regler GmbH Telephone Limburg (+49 6431 2980 Fax (+49 6431 298119 Also regional offices HONG KONG Eurotherm Limited Telephone Hong Kong (+852 2873 3826 Fax (+852 2870 0148 Telex 0802 69257 EIFEL HX INDIA Eurotherm India Limited Telephone Chennai (+9144 4961 129 Fax (+9144 4961 831 Wiring Wire the indicator in accordance with the wiring data given in these instructions. Take particular care not to connect AC supplies to the low voltage sensor input or logic outputs. Only use copper conductors for connections, (except thermocouple. Use a minimum of 0.5mm 2 or 16swg wire for plant connections. Ensure that the installation complies with local wiring regulations. Power Isolation The installation must include a power isolating switch or circuit breaker that disconnects all current carrying conductors. The device should be mounted in close proximity to the indicator, within easy reach of the operator and marked as the disconnecting device for the indicator. Voltage rating The maximum continuous voltage applied between any connection and ground must not exceed 264Vac. For the above reason the indicator should not be wired to a three phase supply with an unearthed star connection. Under fault conditions such a supply could rise above 264Vac with respect to ground and the product would not be safe. Conductive pollution Electrically conductive pollution (for example carbon dust must be excluded from the cabinet in which the indicator is mounted. Where condensation is likely, for example at low temperatures, include a thermostatically controlled heater in the cabinet. Installation requirements for EMC For general guidance refer to Eurotherm Controls EMC Installation Guide, HA025464. It may be necessary to fit a filter across the relay output to suppress conducted emissions. The filter requirements will depend on the type of load. For typical applications we recommend Schaffner FN321 or FN612. Routing of wires To minimise the pick-up of electrical noise, the sensor input wiring should be routed away from high-current power cables. Where it is impractical to do this, use shielded cables with the shield grounded at both ends. IRELAND Eurotherm Ireland Limited Telephone Naas (+353 45 879937 Fax (+353 45 875123 ITALY Eurotherm SpA Telephone Como (+39 31 975111 Fax (+39 31 977512 Telex 380893 EUROTH I JAPAN Eurotherm Japan Limited Telephone Tokyo (+81 3 33702951 Fax (+81 3 33702960 KOREA Eurotherm Korea Limited Telephone Seoul (+82 2 5438507 Fax (+82 2 545 9758 Telex EIKOR K23105 NETHERLANDS Eurotherm B.V. Telephone Alphen a/d Ryn (+31 172 411752 Fax (+31 172 417260 NEW ZEALAND Eurotherm Limited Telephone Auckland (+64 9 2635900 Fax: (+64 9 2635901 NORWAY Eurotherm A/S Telephone Oslo (+47 66 803330 Fax (+47 66 803331 SPAIN Eurotherm España SA Telephone (+34 91 6616001 Fax (+34 91 6619093 SWEDEN Eurotherm AB Telephone Malmo (+46 40 384500 Fax (+46 40 384545 SWITZERLAND Eurotherm Produkte (Schweiz AG Telephone Zurich (+41 55 4154400 Fax (+41 55 4154415 UNITED KINGDOM Eurotherm Controls Limited Telephone Worthing (+44 1903 269888 Fax (+44 1903 269666 http://www.eurotherm.co.uk U.S.A Eurotherm Controls Inc. Telephone Reston (+1 703 787 3405 Fax (+1 703 787 3436 Issue 3, Nov-98. Applies to software versions 1.3 & 1.4-6- HA026248