SD Storage Cabinet. Outstanding performance

Similar documents
SD Storage Cabinet. Outstanding performance

SD Storage Cabinet

SDB Storage Cabinet

HSD Dry Cabinet. Outstanding performance

HSD Dry Cabinet

HSD Dry Cabinet. Outstanding performance

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

XSD Dry Cabinet

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

Long Term Storage Cabinet

SDR Dry Room. Outstanding performance

XSD Dry Cabinet

XSD Dry Cabinet

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

A Member of the ASYS Group A Member of the ASYS Group PRODUCT CATALOGUE

Revolution of Low Humidity Storage!!

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

INSTRUCTION MANUAL ESDA Cabinets with display

ULTRA-LOW HUMIDITY SEIKA. ERC Co., Ltd. ULTRA-LOW HUMIDITY STORAGE CABINETS 1%RH. Conforms to IPC/JEDEC J-STD-033D and IPC-1601 Guidelines.

Instruction Manual heater SH for SD dry cabinets

Revolution of Low Humudity Storage!!

Drying and heating chambers

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Constant climate chambers

INSTRUCTION MANUAL SD and SDB Cabinets

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Constant climate chambers

Chromatographic Air circulated Refrigerator, two-door TC 603

Chromatographic Air circulated Refrigerator, two-door TC 603

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

Laboratory Refrigerator/Deep Freezer TC 802

Constant climate chambers

Constant climate chambers

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

KMF Environmental test chamber for constant climate

Background. Totech dry cabinet

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Model KBF 240 Constant climate chambers with large temperature / humidity range

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Technical data sheet. Lyovapor L-300

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

portable gas analyser

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Constant climate chamber with ICH-compliant illumination

Infrared Moisture Balance (FD-800)

Constant climate chamber with humidity

EC 160 CO 2. Incubator

Model C 170 CO 2 incubators with hot air sterilization

WHA 3000V Hot Air Station

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

CO₂ incubators. C CB series

Constant climate chambers

CLIMATRON GROWTH CABINETS

Constant climate chambers

Model KBF 1020 Constant climate chambers with large temperature / humidity range

CO₂ incubators. C CB series

Introduction. OM-THA2

ECO PDU PE7214/PE7216/PE7324/PE7328

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

DHR Accessories Requirements. Site Preparation Guide

ULTRA.GUARD ultra low temperature freezer

Plant Growth Humidity Chamber

Environmental simulation chamber for complex alternating climate profiles

Operation Manual. (Version 1.5.1)

Model KBWF 720 Growth chambers with light and humidity

Constant climate chambers

Refrigerated Incubators / Environmental Testing Chambers

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Application Note 5305

Compact design for personal use Ready to network with your computer.

Desicators & Dry Cabinets

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Dräger Polytron Pulsar 2 Open Path Gas Detector

Refrigerated Incubator Model and Operating Instructions

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

PVC. 0050, Mini Desiccator Cabinet. 0030/0040, Dry Keepers

Infrared Moisture Balance (FD-660)

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Model KBWF 240 Growth chambers with light and humidity

1 ~ 60% RH Dehumidifying Storage Cabinet Model IDSC-1260

Future Blast Chiller and Blast Chiller/Freezer cabinets

Substation Monitoring System

STABILITY ICH. ICH Stability Tests

Focus 4010\ Focus 4010 HT porcelain firing furnace

DRY PACK INFORMATION TROCKENVERPACKUNG

Constant climate chambers

DEKO 25 washer-disinfector

Transcription:

Storage Cabinet Outstanding performance The SD Series is equipped with a dynamic drying unit U-2000. Engineered for medium to long-term constant low humidity storage of 2% RH. Humidity, temperature, alarm functions are shown and can be adjusted on a digital display. The circulation of air in the cabinet is regulated through an integrated fan. All surfaces are ESD coated in conformity with current ESD 61340-5-1 standard. The SD 702-21 is ideal for the moisture-proof and anti-oxidation storage of wide-ranging technologies and conforms with IPC/JEDEC J- STD 033C & IPC-1601.

Standard Features Accuracy of sensor RH% & T C +/- 3% RH, +/- 0,3 C ESD safe design Norm (IEC 61340-5-1) ESD metal painted body (<10 6 Ohm/sq) Dissipative glazing (in- and outside 10 8 Ohm/sq) Door alarm buzzer Longer door openings are detected Lockable doors 2 doors locked with key Shelves In height adjustable chrome steel shelves (5 pcs) 1 series digital display Very convenient settings of RH%, temperature, alarm and calibration functions. Drying unit U-2000 drying unit ESD bonding point ESD wristband can be connected to the cabinet Pre mounted holes For nitrogen unit & heater Power supply Power cord 5 meter with IEC plug Benefits Data logging Through network with software and optional hardware Recovery time after door opening <30 minutes to below 2% (by 1 door opening) Highly energy efficient Average power consumption 35 W/h. Option availability N 2 auto flow, heating, SMD reel racks, etc. IPC According to IPC-JEDEC J-STD 033C & IPC-1601 Temperature Maximal up to 40 C (optional) Maintenance The drying unit is maintenance free, easy to service

Technical data cabinet External dimensions: (W x H x D) 620 x 1675 x 768 mm Internal dimensions: (W x H x D) 610 x 1533 x 735 mm Weight: 152 kg Weight on shelf: 100 kg Max. loading capacity: 300 kg Body: Steel, conductive coated 10 7 Ω/sq Shelves (WxD): 5 pcs, 577 x 580 mm adjustable. Volume: 680 L Electric supply: 230 VAC (120 VAC optional) Power consumption: Average 35 W/h (excl. heating) Protection class: Class 1, hard grounded Humidity level cabinet: 2% RH depending on amount of door openings Technical data type 1 display Settings Nominal value humidity Nominal value humidity alarm (light) Delay time humidity alarm Nominal value temperature Door alarm buzzer Offset possibilities Technical data dry-unit U-2000 series Control: Adjustable with control panel type 1 Dehumidifying Temperature: 10 40 C Electric supply: 230 VAC (120 VAC optional) Dimensions (L x B x H): 260 x 380 x 100 mm Weight: 8,1 kg Technical data heater SH 230-1 Voltage: 230 VAC / 50 Hz (120 VAC / 60 Hz optional) Power: 530 W Temperature sensor: PTC 100 Thermal protection: 90 C Temperature range: 30-40 C Air flow: 86 m 3 /h Display tolerance: 1 digit at 25 C Technical data N 2 (Auto) Flow Power supply: 90-230 VAC N 2 connection: 8mm hose connection N 2 pressure: 1-6 bar N 2 standby amount: 0-25 L/min N 2 purge: 0-25 L/min Purge time: 0-99 min

Performance test Test conditions Instrument: Vaisala Type of dew point sensor: Vaisala drycap 180M Accuracy of dew point sensor: ± 0,2 C at + 20 C (+ 68 F) Location of sensor: In the direct surroundings of the cabinet sensor Ambient conditions: Hum. 50 ± 5% rh, 22 C ± 2 C, Pressure 994 ± 20 hpa Door openings: 2 door openings, 15 sec. For more detailed test results, please refer to our website.

Technical drawings Dimensions mentioned in mm. Shelves Number of shelves bottom section 2 3 4 5 Distance (in mm) between shelves if equally divided in bottom section 350 230 175 125 Remaining space between top shelf and middle beam 370 225 125 120 Remaining space between bottom shelf and bottom cabinet 330 230 180 125 Loading capacity shelves m 2 (1155 mm x 780 mm) 0.67 1.00 1.33 1.67 Number of shelves top section 2 3 4 5 Distance (in mm) between shelves if equally divided (if bottom shelf is mounted at lowest possible position in top section) 350 230 175 125 Remaining space between top shelf and top beam 370 230 125 125 Remaining space between bottom shelf and middle beam 330 230 180 130 Loading capacity shelves m 2 (1155 mm x 780 mm) 0.67 1.00 1.33 1.67 Measurements can slightly deviate.

Technical drawings

Options SMD Reel rack with reel supports 460 mm length. Item number 20014000 Reel support Additional reel supports for 20014000. Item number 20014200 Humidity alarm signal lamp One color (orange or red), magnetically fixed, providing optical signals on operational states and exceeded limit values. Operates on 24V. Item number 20016033 N 2 Autoflow system The autoflow system is developed to use in combination with a Totech drying cabinet. The device is used for the quick removal of moisture in the cabinet after the doors have been opened. The drying process is realised by using Nitrogen (N 2 ), which is purged automatically after the doors are closed. (timer controlled) Item number 22613001

Options Shelf standard Chrome steel shelf, short: Item number 20070201 Chrome steel shelf, long: Item number 20070200 Set main spare parts SD cabinet Set includes the main spareparts of the SD cabinet: Dry-unit U-2000, Main PCB and Power Supply Item number 30006099 Exchange set main spare parts SD cabinet: Item number 30006096 SuperDry Data Logger Highly accurate data logger with standard Ethernet interface. Compatible with the Free Totech Viewer and Totech Monitor. Item number 47000582 Adjustable legs 4 in height adjustable legs (63-80mm) Item number 20010010