Lo-Carbon T-series Window & Roof Models

Similar documents
T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra SELV

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon SELV Tempra

Centrif Duo & Centrif Duo Plus

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Silhouette Installation and Wiring Instructions

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Lo-Carbon Quadra Centrifugal Fan

HR200WK Through the wall Heat Recovery Ventilator

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Installation and Wiring Instructions

SUPER T WALL FANS. Installation and Wiring Instructions

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Installation & Operating Instructions

Sentinel Kinetic MVHR RANGE

Installation & Operating Instructions

FLUEBOOST. flueboost 350 gas fire model

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Lo-Carbon PoziDry Pro

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

irconcentre.co.uk airooncentre.co.uk

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

100 FLUEBOOST

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Lucci Designer Hi Flow Exhaust Fan

BLOW DRY & GO HAIR KIT

Simply Silent Contour 4 (100mm) Axial Extraction Fan

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Xpelair Simply Silent TM Contour Fan

OWNERS INSTRUCTION MANUAL

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

JUNEAU JUN. 08/51193/0 Issue 0

EH0533 Indoor Climate Control

Xpelair Simply Silent DX150

60cm Integrated Turbo Extractor

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

USER MANUAL. PEDESTAL FAN (16 Inch)

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

Appliance Operation Manual

pure indoor living HIGH PERFORMANCE desk fan MODEL: BSF002, ISF004 INSTRUCTION MANUAL

Zip Chillmaster Floor Mounted Chiller

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

POWER SHOWERS Models 4500M 5002M 4500T 5002T

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

Australia. New Zealand

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

60cm Canopy Extractor

SP16. 08/50740/1 (UK) - Issue 1

GEH9026G Cooker Hood

INSTANTANEOUS ELECTRIC SHOWER

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

PERFORMANCE SHOWER PRODUCTS

UBBU60LFA. Built-under Fridge Manual for Installation, Use and Maintenance IM UBBU60LFA_

Stainless Steel Chimney Extractor

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

CoCo LoCo BLOW & GO NUTS DRYER. LSHD24 Instruction Manual

Contact Details. Please note that some of the contact details on this PDF document may not be current.

User Manual for your GEH6017 & GEH9017 Cooker Hood

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Xpelair Simply Silent TM DX100 Fan

EH0554 Indoor Climate Control

Instructions for use

QUALITY SPACE HEATERS

CLASSIC-100. Instruction leaflet. Instruction leaflet

Chapter 3 Cooling, heating and ventilation systems

60cm Chimney Extractor

Stainless Steel Chimney Extractor

EH Fin Oil-Filled Radiator with timer

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS

EN Instruction on mounting and use

D100, D125 & D150. Installation Instructions

Electrisaver User and Installation Instructions

18 INCHES, OSCILLATING STAND FAN

INSTALLATION INSTRUCTIONS USER GUIDE

Suits all KPF849 models

EH " (40cm) Remote Control Wall Fan

Transcription:

Lo-Carbon T-series Window & Roof Models Installation & User Instructions WIRED 456165A (9 WW) 456168A (9 RF) 456173A (12 WW) 456176A (12 RF) WIRELESS 456169A (9 WW) 456172A (9 RF) 456177A (12 WW) 456180A (12 RF) READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS

IMPORTANT 1. THE FAN MUST BE SITED AND CONNECTED IN ACCORDANCE WITH CURRENT IEE REGULATIONS (UK) OR THE APPROPRIATE STANDARDS IN YOUR COUNTRY. 2. THIS APPLIANCE IS NOT SUITABLE FOR INSTALLATION IN A SHOWER CUBICLE OR ENCLOSURE AND MUST BE SITED AWAY FROM ANY SOURCE OF WATER SPRAY, AND MUST BE OUT OF REACH OF A PERSON USING A FIXED BATH OR SHOWER. 3. SITE AWAY FROM DIRECT SOURCES OF HEAT IN EXCESS OF 50ºC OR LESS THAN 10ºC. 4. WHEN THE FAN IS USED TO REMOVE AIR FROM A ROOM CONTAINING A FUEL-BURNING APPLIANCE, PRECAUTIONS MUST BE TAKEN TO AVOID BACK-FLOW OF GASES INTO THE ROOM FROM THE OPEN FLUE OF GAS OR OTHER APPLIANCE. ENSURE THAT THE AIR REPLACEMENT IS ADEQUATE FOR BOTH THE FAN AND THE FUEL-BURNING APPLIANCE. 5. IT IS RECOMMENDED THAT THE CONNECTION TO THE CONNECTOR SOCKET IS MADE WITH FLEXIBLE CABLE FOR EASY MAINTENANCE. 6. WIRING SHOULD BE VIA A SWITCHED SPUR WITH A 3 AMP FUSE (UK ONLY). 7. DOUBLE POLE SWITCH WITH A MINIMUM CONTACT SEPARATION OF 3MM OR PLUG AND SOCKET SHOULD BE LOCATED OUTSIDE OF A ROOM CONTAINING A FIXED BATH OR SHOWER. 8. THIS APPLIANCE MUST BE EARTHED. 9. READ THESE INSTRUCTIONS FULLY BEFORE COMMENCING INSTALLATION. 10. THE APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. 11. YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. 12. A SHORT CIRCUIT OF THE AIR FLOW SHOULD ALWAYS BE AVOIDED BY SITING THE FAN AS FAR AWAY AS POSSIBLE FROM AND OPPOSITE TO THE MAIN SOURCE OF AIR REPLACEMENT. B1/ 2 B1/ 2 Fig. 1 SPEED CONTROLLER CONNECTION SOCKET (WIRED VERSION ONLY) POWER SUPPLY/ RECEIVER UNIT CONNECTOR SOCKET MOTOR BODY HOUSING HOUSING INDOOR GRILLE ROOF COWL SHUTTER ACTUATOR IMPELLER BASE OUTER GRILLE SECTION 2

FAN DIMENSIONS Before commencing work, study the tables shown in figures C1/ C2 to ensure fan will fit in position proposed. NB: Allow a minimum of 54mm above fan casing for withdrawal of connector socket. Please note that for all Roof Fan installations a suitable sealing compound must be used to seal the exterior roof cowl assembly to the glass/or roof plate, to ensure a weatherproof seal. D1 THICKNESS OF GLASS Fans can be fitted in most types of glass and fixing thickness up to 32mm, with the screws provided. When fixing thickness exceeds 32mm, the unit should be secured with Extended Fixing Rods. If the unit is to be installed in a location exposed to severe wind turbulence or in non-vertical panes, thicker glass will be required consult your nearest Vent-Axia Sales, Service and Distribution Centre. C1 C2 SIZE 9 12 A 39mm 41mm B 150mm 177mm C 304mm 381mm D 302mm 378mm EØ 260mm 337mm F 20mm 20mm G 54mm 54mm SIZE 9 12 A 136mm 171mm B 150mm 177mm C 304mm 381mm D 302mm 378mm EØ 260mm 337mm F 20mm 20mm G 400mm 500mm D1 PREPARATION FOR INSTALLATION E1 E2 E3 E4 E5 Place fan unit, impeller downwards, on a flat surface. Unscrew the grille-securing screw located at the top of the grille. Remove grille. Partially unscrew the two safety catch screws on the face of the housing Depress the side catches. Lift off the housing. Release the Power Supply/Receiver Unit catch, located at the bottom left of the motor body housing assembly. E5a Lift the Power Supply/ Receiver Unit until the second catch engages. Slide the speed controller connection socket from the housing (wired version only). 3

E6 E7 Ease back the motor support safety catch, located to the left of the connector socket opening. Rotate motor body housing anti-clockwise until the bayonet catch disengages. Withdraw motor body housing and place with the impeller downwards. E1 E2 E3 E4 E5a E5 E6 4 E7

INSTALLATION F1 From the inside: Fit the spigot through the fixing hole, with the connector socket cut out at the top. Ensure that the rubber seal is correctly located over the four lugs on the spigot. F2i WINDOW From outside: Place the outdoor grille assembly with the louvres slanting downwards, and the Vent-Axia logo at the top of the grille, over the projecting spigot. F2ii ROOF From outside: Place the exterior roof cowl over the projecting spigot. Use a suitable sealing compound between the cowl and the glass/or roof plate. F3i/ ii Secure the outdoor grille or roof cowl, using the fixing screws supplied. Then tighten the screws in turn to give an even pressure around the hole. F4a/ b Refit the motor body housing assembly and turn clockwise until the locking catch is engaged. Take care not to trap the mains supply cable or the speed controller socket cable (wired version only). F5 Release the Power Supply/Receiver Unit locking catch and lower until the catch engages in the lower position, fix the controller socket into position (wired version only). F6 Lift the black rubber gasket on the Power Supply/Receiver Unit and switch the three-position switch to the required running option, then replace the gasket seal. F7 If a speed controller is being used refer to the relevant Speed Controller Fitting and Wiring instructions. F8 Refit the housing ensuring that no internal wires are trapped between the housing and base. F9 Engage the two side catches. Tighten the two side catch screws. F10 Replace the indoor grille with the louvres slanting upwards, with the Vent-Axia logo at the bottom of the grille, and secure with the retaining screw. F1 F2i F2ii 5

F3i/ ii F4a F5 F4b F6 F7 FOR SPEED CONTROL REFER TO THE RELEVANT FITTING AND WIRING INSTRUCTIONS SUPPLIED WITH THE WIRED/ WIRELESS CONTROL. F8 F9 F10 6

TYPICAL ROOF INSTALLATIONS USING VENT-AXIA ACCESSORIES A (A) ROOF LIGHT All T-Series roof models are designed to fit directly into horizontal and sloping glass including wired cast and sealed double glazing up to 32mm thick. For materials of greater thicknesses extended fixing rod sets are available, allowing the unit to be fixed through a spacing of up to 370mm. Rod thread: 3.5mm Maximum fixing thickness: 370mm (B) PITCHED ROOF B All T-Series roof models may be installed in fixing plates with zinc or lead weathering apron (provided by others), fitted directly to a tiled or slated roof to provide a water-tight installation. A suitable sealing compound should be used between the weathering apron and the exterior unit seal The illustration shows a T-Series roof model fitted with a direct mount spigot and flexible ducting. C (C) CORRUGATED ROOF All T-Series roof models are suitable for fixing through corrugated sloped and vertical cladding using a suitable soaker flange. The soaker flange consists of a replacement sheet with a flat section to carry the unit. A suitable sealing compound should be used between the plate and the exterior unit seal. (D) FLAT ROOF D All T-Series roof models may be installed through solid roofs using a roof plate assembly and, if required, an eggcrate grille or louvred grille in the ceiling below. Alternatively, if ventilation is from a suspended ceiling, single spigots and flexible ducting may be used to connect the unit and extract grille. Roof plate assemblies are manufactured in high impact thermoplastic. A suitable sealing compound should be used between the plate and exterior unit seal. 7

WIRING THE CONNECTOR SOCKET Ensure that the supply (Voltage, Frequency and Phase) complies with the rating label. This appliance must be earthed. F11 Remove the top cover from the connector socket by undoing the 2 retaining screws. F12 Lift up lever and slide out top cover. F13 Loosen cable clamp screws and pass the cable through the clamp. (It may be necessary when using some 3-core cables to reverse the cable clamp to ensure that the cable is securely retained. For ease of wiring, the terminal block may be removed from the connector housing. F14 Tighten cable clamp screws evenly, ensuring a secure grip on the outer sheath of the cable. F15 Slide the top cover back on and secure with the 2 retaining screws. F16 Fit connector socket and push down on the lever to lock it in position. Fig 2 Using an On/Off switch: Connect the mains supply to the fan connector socket. Fig 3 Auxiliary sensor switching: Connect the mains supply to the fan connector socket. F11 F13 F12 F14 F16 F15 Fig. 2 T-Series Lo-carbon Connection socket (Wired version only) Please refer also to the speed controller fitting and wiring instructions. 8

Fig. 3 T-Series Lo-carbon Connection socket (Wired version only) Please refer also to the speed controller fitting and wiring instructions. ISOLATE FROM THE POWER SUPPLY PRIOR TO ANY MAINTENANCE AND CLEANING USER INSTRUCTIONS At intervals appropriate to the installation, inspect and clean the fan to ensure there is no build up of grease or dirt on the impeller or the motor. The motor is fitted with sealed for life bearings and does not require lubrication. DISMANTLING G1 From the inside, remove the connector socket by lifting up the lever gently with a finger, unplug the controller cable (wired version only). G2 Unscrew the indoor grille retaining screw and remove the grille. G3 Partially unscrew the two side catch screws on the housing and depress the two side catches. G4 Remove the housing. G5a Release the Power Supply/Receiver Unit catch, located at the bottom left of the motor body housing assembly. G5b Lift the Power Supply/Receiver Unit until the second catch engages. Slide the controller socket from the housing (wired version only). G6 Release the motor body housing assembly locking catch located to the left of the connection socket opening and rotate the motor body housing assembly anti-clockwise until the bayonet catches disengage. G7 Withdraw the motor body housing assembly and put to one side, with the impeller facing upwards. G8 Remove the impeller with a sharp pull away from the motor. G9 Unscrew the outdoor grille retaining screw and remove the grille. CLEANING IMPORTANT: Keep all electrical components away from water. G10 Wipe the motor, housing assembly and roof cowl (if fitted) with a damp cloth. G11 Wash all non-electrical components in warm water and detergent. 9

REASSEMBLY - ALLOW THE COMPONENTS TO DRY BEFORE REASSEMBLY G12 Replace the outdoor grille with the louvres slanting downwards, and the Vent-Axia logo at the top of the grille. Tighten the retaining screw located at the bottom of the grille. G13 Align the impeller with the locating pins on the motor shaft and refit the impeller with a sharp push. G14a/b Refit the motor body housing assembly and turn clockwise until the locking catch is engaged. Take care not to trap the speed controller socket cable (wired version only). G15 Release the Power Supply/Receiver Unit locking catch and lower until the catch engages in the lower position, fix the controller socket into position (wired version only). G16 Refit the housing ensuring that no internal wires are trapped between the housing and base. G17 Engage the two side catches. Tighten the two side catch screws. G18 Replace the indoor grille with the louvres slanting upwards and the Vent-Axia logo at the bottom of the grille, then secure with the retaining screw. G19 Replace the connector socket, push firmly into position and press the black locking peg down flush with the top of the connector socket. Plug the controller cable connector into the socket (wired version only). RECONNECT THE MAINS SUPPLY AND SWITCH THE UNIT ON. G2 G1 G3 G4 G5a G5b G6 G7 G8 G9 10

G10 G11 G12 G13 G14a G15 G14b G16 G17 G18 G19 11

The abc Guarantee Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local supplier. Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s option replaced, without charge, provided that the product:- Has been installed and used in accordance with the instructions given with each unit. Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label attached to the unit). Has not been subjected to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing evidence of date and source of purchase. The guarantee is offered to you as an extra benefit, and does not effect your legal rights Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. Tel: 01293 526062 Fax: 01293 551188 UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA SALES ENQUIRIES: Tel: 0844 8560590 Fax: 01293 565169 TECHNICAL SUPPORT: Tel: 0844 8560594 Fax: 01293 539209 For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX 428208E 1210 12