OPERATION MANUAL VCX-4 Vacuum Coolant Exchanger

Similar documents
Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Audi-Larm Audible Alarm

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Refrigerant Recovery Machine. Model No Operating Manual

17 U.S. gallon portable low profile drain with electric pump

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation, Operating, and Maintenance Manual

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

USER MANUAL UN-200V / UN-200VH

INSTALLATION INSTRUCTIONS

690 and Power Fishing Systems

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

DYNA-CRIMP* Hydraulic Crimping Head, PN 69099

BMW E36 Thermostat Removal And Coolant Flush

Installation & Operating Guide

6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

Model K 5800 G Part No

2001 Smith Eastern Corporation

INSTALLATION INSTRUCTIONS

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

K Specifications. Max. Water Volume

Page 1 of 18. Part# /5/2013

Engine Cooling Pulsator

Niles Steel Tank Hot Water Generator Installation and Operation Manual

55-Gallon Dispenser Package

Xaact Spot. Xaact Hot Spot

Tornado Operation & Maintenance Manual

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

Gen II Entree Bath. Maintenance Manual. All Models. Important Safety Instructions Read & Follow All Instructions Thoroughly

Model HD 3501 Part No High Pressure Washer Operator Manual

CONSTANT SUCTION UNIT

690 Power Fishing System

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

OWNER S MANUAL. Solar Collector DELUXE

Service Bulletin

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS

K Specifications. Max. Water Volume

Model K 3000 G Part No

SECTION 1-1 SAFETY PRECAUTIONS DOUBLE ARM MIXER CHAPTER 1: SAFETY

TECHNICAL INSTRUCTIONS

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

COBRA -300H EXTRACTOR

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

User s Information Manual

GETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)

Models: GW/R-T GW/R-2-T GW/R-3-T

Model K 4400 G Part No High Pressure Washer

Mopit 4 Operator s / Service Manual

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

C7 Series Split System Uncased Indoor Coils

Models Series Series

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

PRO 2000i LOW LEVEL DEPOSITOR

COOLING SYSTEM. Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... DESCRIPTION...

Installation Manual CARBONATOR With Plain-Water Booster

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

High Output Vacuum/Pressure Pump

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

HX Field Replacement Kit

2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

INSTALLATION INSTRUCTIONS

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

DOUBLE O-RING GEO-PRIME TANK Non-Pressurized Flow Center System INSTALLATION INSTRUCTIONS. Model: DORGPT-1 NOTE:

Setup. Important. Texture Spraying (material supplied from unit)

PWASH Gallon Parts Washer Assembly & Operating Instructions

Hydraulic Crimping Head, PN

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Model K 330 M Part No

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

INSTRUCTION MANUAL W-400

ADVANTAGE-100H-SC EXTRACTOR

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

12 Ton Hydraulic Crimping Head, PN

Hydraulic Crimping Systems

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

3-1/2 Gallon Parts Washer

OPERATION & MAINTENANCE MANUAL RHS680

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

Installation Instructions

MODEL 4246 MIXER-GRINDER

TECHNICAL DATA. Wet 26a. February 22, 2009

COBRA -H EXTRACTOR 120V

Transcription:

OPERATI MANUAL VCX-4 Vacuum Coolant Exchanger MAHLE Aftermarket Inc., Service Solutions 0 Innovation Drive York, PA 740 800-468- www.servicesolutions.mahle.com Manual P/N 05-8446-00 (REV B)

TABLE OF CTENTS Component Description... Safety Precautions... Home Position... 4 Fill Tank through Hose... 5 Empty Radiator... 6 Special Hookups... 8 Fill Radiator... 9 Top Off & Flush Radiator... 0 Empty Waste Tank... Empty Tank... Troubleshooting... Parts Identification... 4 Flow... 5 Page

COMPENT DESCRIPTIS Unpack all components and verify quantities per this illustration. Contact MAHLE if any items are missing. NEW COOLANT TANKS DUAL -WAY PANEL VALVE WASTE COOLANT TANK Waste SYSTEM VACUUM GAUGE SHOP AIR COUPLER -WAY PANEL VALVE ADAPTER HOSE CE PLUG ADAPTER QTY= CE ADAPTER VALVE CLEAR REINFORCED HOSE FT Page

SAFETY PRECAUTIS WARNING: Failure to follow these precautions can result in serious injury or death. Your VCX Vacuum Coolant Exchanger was developed to provide you with years of trouble-free service in accordance with the utilization of proper inspection and maintenance techniques. It is important to understand this machine functions with its coolant cylinders either under pressure or vacuum, so it is imperative all cylinders receive proper inspection to ensure the proper and safe operation of the equipment is maintained throughout its life cycle. Read and understand the Operation Manual completely before operating this unit. Always wear proper skin protection when operating and maintaining this equipment. Always wear safety glasses when operating and maintaining this equipment. Before any VCX machine use it is required for the operator to visually inspect the coolant cylinders for defects such as cracks, nicks, gouges, chips, impact marks, fractures, hairline cracks, crazing, severe discoloration, cloudiness or hazing or other physical damage. VISUAL TUBE INSPECTI IS REQUIRED PRIOR TO EACH MACHINE USE! IF ANY TUBES EXHIBIT ANY DEFECTS, THEY MUST BE REPLACED BEFORE MACHINE OPERATI! FAILURE TO COMPLY MAY RESULT IN TUBE FAILURE AND POSSIBLE INJURY! Automotive cooling systems can be under pressure and extremely hot. Place a rag over the radiator cap during removal to avoid injury. Use extreme caution when removing caps. Coolants are corrosive and poisonous to people and animals. Clean up any spills immediately. Do not allow waste coolant tank to overflow. Immediately clean up any coolant spills. Damage to the vehicle and equipment can result from the corrosiveness of coolant. Continuous monitoring of the coolant exchange process is required. Unit is equipped with factory preset pressure regulator. Do not attempt pressure adjustment without MAHLE Technical Support authorization. If cracks appear in the cylinders, hoses or adapters these parts must be replaced. If VCX unit tipped over, resulting in a fall of the machine onto any side, it is mandatory all coolant tubes be replaced immediately before the machine is placed back into service. If leaks occur at the bottom or top of the cylinders, contact MAHLE for troubleshooting instructions. The cylinders, hoses and adapters are plastic and rubber products and are in contact with oil and chemicals which may lessen their durability. Therefore, when soiled, they should be cleaned with water and a mild detergent. Caution: Do not clean with thinners, solvents or any other chemical cleaners. Only disassemble or reassemble unit parts when directed by an MAHLE representative. Take precautions to keep clothing, hair, hands, hoses, etc. away from all moving parts of the vehicle. Comply with local, state and federal regulations for fluid disposal. Material Safety Data Sheets (MSDS) must be obtained on all chemicals and placed in a shop file for reference. These are available for download and printing on the MAHLE web-site (www.servicesolutions.mahle.com). Go to TECHNICAL HELP and look under Technical Bulletins. CAUTI: Failure to follow the precautions as outlined in the operation manual can result in damage to the engine, vehicle or equipment which will not be supported or covered under warranty. Page

POSITI NEW NEW (PRESSURE) (VACUUM) NEW TURN E VALVE TO SELECT NEW COOLANT SOURCE FILL RADIATOR VACUUM GAUGE TURN ALL VALVES TO AFTER EVERY PROCEDURE VCX- 4 The above valve configuration is set before the VCX is connected to the shop air supply. This is also the position that the valves are returned to after each procedure. To select a procedure turn all of the valves to the colored triangle that corresponds with the desired procedure. While performing certain functions the appropriate NEW tank valve must be set to the position. Cone Adapter Valve This illustration demonstrates the open and closed position on the Cone Adapter Valve. The closed position is 90 degrees clockwise from center. Valve Open Valve Closed Page 4

. Turn all panel valves to the Home position.. Connect shop air to VCX Shop Air Coupler. THROUGH HOSE. Turn the appropriate Tank Valve to fill the corresponding tank. Note that Tank is used in the illustration shown below. 4. Turn the other panel valves to the Fill Tank position as shown in the illustration below. This orientation can also be obtained by positioning the panel valves toward the green highlights closest to each valve. 4. Place the Cone Adapter, with the Adapter Hose attached, into the container of new coolant. Open the Cone Adapter Valve to draw coolant into the Coolant Tank. 5. Raise the hose out of the container of new coolant when the desired fluid level is reached in the Coolant Tank. 6. Close the Cone Adapter Valve. 7. Turn all valves to the Home position when done. Note: DO NOT OVERFILL. NEW NEW (PRESSURE) (VACUUM) NEW Waste TURN E VALVE TO SELECT NEW COOLANT SOURCE VACUUM GAUGE TURN ALL VALVES TO AFTER EVERY PROCEDURE VCX- 4 FILL RADIATOR Cone Adapter Clear Hose Adapter Hose 50/50 Mix Water/Coolant Page 5

. Run the vehicle with the heater turned on to bring the engine to operating temperature. Turn the engine off.. Turn all panel valves to the Home Position as shown on page 4.. Connect shop air to VCX Shop Air Coupler. 4. Turn all panel valves to the Empty Radiator position as shown in the illustration below. This orientation can also be obtained by positioning the panel valves toward the black highlights closest to each valve. 5. Insert the Adapter Hose into the Cone Adapter. Insert end of Adapter hose into overflow tank. Turn the Adapter Hose Valve to the open position to withdraw the coolant. NEW NEW (PRESSURE) (VACUUM) NEW TURN E VALVE TO SELECT NEW COOLANT SOURCE FILL RADIATOR Waste VACUUM GAUGE TURN ALL VALVES TO AFTER EVERY PROCEDURE VCX- 4 Cone Adapter Valve Adapter Hose Clear Hose Engine Block Heater Core Water Pump Radiator Overflow Page 6

CTINUED 6. Connect the Adapter Hose to the radiator overflow port to relieve radiator pressure. Watch the System Vacuum Gauge and make sure the vacuum level increases and then stays greater than 0 InHg. Carefully remove radiator cap. Use a shop rag over the cap when removing to avoid injury in case there is still pressure. Remove the Adapter Hose. 7. Place VCX Cone Adapter snugly into the radiator spout. Do not force the Cone Adapter into the spout; the suction pressure from the VCX should secure it adequately. Verify that the Cone Adapter Valve is in the open position. Waste 8. Start the engine once fluid starts to move through the clear hose and into the VCX Waste Coolant Tank. Verify that the System Vacuum gauge reads at least InHg. 9. Once the waste coolant from the vehicle stops flowing through the clear hose, turn all of the panel valves to Home Position and turn the engine off. Clear Hose PINCH HOSE Radiator Hose Cone Plug Adapter Overflow Water Pump Engine Block DO NOT REMOVE CE ADAPTER FROM THE RADIATOR! Note: In some cases it may be necessary to pinch off the hose going from the radiator neck to the overflow container. This is only necessary when the vacuum leaks through this hose. The hose should be opened only after the Fill Radiator procedure. WARNING Do not overfill the Waste Tank Page 7

SPECIAL HOOKUPS Seal Tight Radiator. Insert the Adapter Hose into the end of the Cone Plug Adapter.. Place the Cone Adapter snugly into the radiator, coiling the excess length of Adapter Hose at the bottom.. Follow the Empty Radiator procedure steps -9. More Effective Setup for Empty Radiator During the Empty Radiator procedure clamp off the upper radiator hose and follow steps -9 of the Empty Radiator section. PINCH HOSE Radiator Hose Adapter Seal. In some cases it may be necessary to cut up to 0.75" off of the Cone Plug Adapter. This is only necessary when a tight seal cannot be created due to bottoming out against the inside of a shallow radiator neck. Overflow. Take care to cut a clean edge free of loose debris. PINCH HOSE Page 8

FILL RADIATOR Fill Radiator. Turn all panel valves to the Home position.. Connect shop air to VCX Shop Air Coupler.. Turn all panel valves to the Fill Radiator position shown in the illustration below, this orientation can also be obtained by positioning the panel valves toward the magenta highlights closest to each valve. Verify that the Cone Adapter Valve is open. 4. Turn the appropriate Tank Valve to fill from the corresponding tank. Note that Tank is used in the illustration shown below. 5. coolant is automatically pulled out of the VCX Coolant Tank and into the vehicle radiator through the clear hose. NOTE: IF THE CE ADAPTER BECOMES DISLODGED BEFORE YOU CAN BEGIN THIS PROCESS YOU MUST RERUN THE FUNCTI, WITHOUT STARTING THE VEHICLE, TO REGAIN THE VACUUM NEEDED TO FILL THE VEHICLE COOLANT SYSTEM. 6. Once the coolant stops moving through the clear hose turn all of the panel valves back to the Home position and remove the Cone Adapter from the radiator. 7. Turn all valves to the Home position. 8. Close the Cone Adapter Valve. NEW NEW (PRESSURE) (VACUUM) Waste TURN E VALVE TO SELECT NEW COOLANT SOURCE NEW FILL RADIATOR VACUUM GAUGE TURN ALL VALVES TO AFTER EVERY PROCEDURE VCX- 4 Clear Hose Radiator Hose Engine Block Cone Plug Adapter Overflow Water Pump PINCH HOSE Page 9

. Turn all panel valves to the Home position.. Connect shop air to VCX Shop Air Coupler.. Turn the Cone Adapter Valve to the closed position. 4. Turn the appropriate Tank Valve to fill from the corresponding tank. Note that Tank is used in the illustration shown. 5. Turn all panel valves to the Top Off position as shown in the illustration. This orientation can also be obtained by positioning the panel valves toward the blue highlights closest to each valve. 6. Open the Cone Adapter Valve to fill the radiator and overflow to the proper levels. 7. Turn all valves to the Home position. 8. Close the Cone Adapter valve when done. 9. Replace radiator and overflow caps. NEW TURN E VALVE TO SELECT NEW COOLANT SOURCE VACUUM GAUGE NEW NEW TURN ALL VALVES TO AFTER EVERY PROCEDURE VCX- 4 (PRESSURE) (VACUUM) FILL RADIATOR FLUSH RADIATOR. The Coolant Tank needs to be filled with water. See Empty Waste Tank and Fill Tank procedures.. The Empty Radiator function must be run to completion.. Run the Fill Radiator procedure. 4. The Empty Radiator function must be run again to extract all of the water inside the cooling system. 5. Repeat steps and 4 until the desired results are achieved. Once completed new coolant needs to be added to the vehicle system. Page 0

. Turn all panel valves to the Home position.. Connect shop air to VCX Shop Air Coupler.. Close Cone Adapter Valve. 4. Turn all panel valves to the Empty Waste Tank position shown in the illustration below. This orientation can also be obtained by positioning the panel valves toward the red highlights closest to each valve. 5. Place the end of the clear hose into a bulk waste container and open the Cone Adapter Valve. 6. Waste coolant will begin leaving the VCX from the Waste Coolant Tank through the clear hose. Be cautious not to spill waste coolant onto the floor as the hose may jump when the Waste Coolant Tank is nearing empty. Clean up any spills that may occur immediately. 7. Once the Waste Coolant Tank is empty, close the Cone Adapter Valve and turn all valves to the Home position. NEW NEW (PRESSURE) (VACUUM) NEW TURN E VALVE TO SELECT NEW COOLANT SOURCE FILL RADIATOR Waste VACUUM GAUGE TURN ALL VALVES TO AFTER EVERY PROCEDURE VCX- 4 Clear Hose Cone Adapter Valve Bulk Waste Container Page

. Turn all panel valves to the Home position.. Connect shop air to VCX Shop Air Coupler.. Close Cone Adapter Valve. 4. Turn the appropriate Tank Valve to empty from the corresponding tank. Note that Tank is used in the illustration shown below. 5. Turn all panel valves to the Empty Tank position shown in the illustration below. This orientation can also be obtained by positioning the panel valves toward the blue highlights closest to each valve. 6. Place the end of the clear hose into a bulk storage container and open the Cone Adapter Valve. 7. Coolant will begin leaving the VCX from the Coolant Tank through the clear hose. Be cautious not to spill coolant onto the floor as the hose may jump when the Coolant Tank is nearing emptiness. Clean up any spills that may occur immediately. 8. Once the Waste Coolant Tank is empty, close the Cone Adapter Valve and turn all valves to the Home position. NEW NEW (PRESSURE) (VACUUM) NEW Waste TURN E VALVE TO SELECT NEW COOLANT SOURCE VACUUM GAUGE TURN ALL VALVES TO AFTER EVERY PROCEDURE FILL RADIATOR VCX- 4 Clear Hose Cone Adapter Valve Bulk Waste Container Page

TROUBLESHOOTING Problem Vacuum becomes weak Leakage 8 5 Solution Inside of the VCX, there is a venturi vacuum generator that may have collected debris during the operation of the unit. If this occurs, the vacuum will become weak resulting in a lower vacuum reading on the System Vacuum gauge and poor performance. Remove the venturi from the line and blow shop air through it. Use the Parts Identification (page 4) to locate the venturi. Reconnect to correct lines when done. There may be a vacuum leak at either the top or bottom sealing point on the tanks. Fill the tank to the top with water and turn all valves to the Home position. Close the Cone Adapter Valve and turn all valves to the Empty (leaking tank) position. Check for leaks and follow guidelines from the Leakage section. Debris may have collected at the bottom of the tank. Disassemble tank and clean the base of tank. Take care when reassembling not to over tighten the hex nut (use 60 lb/in torque wrench). Do not use pneumatic or power tools. Over time, the o-ring at the bottom or top of the cylinder may become worn. Inspect and replace if needed. See part break down on left. Tank Overflow External Clear Hose If fluid is ever filled to the top of the tank while using the unit there is a device that will release excess to the inside of the cabinet. Using the VCX to remove coolant from a vehicle creates high temperatures throughout the unit particularly where the clear hose connects to the Cone Adapter. Repeated exposure to these temperatures may cause deterioration of the hose. If possible cut affect area off and reconnect Cone Adapter. If replacement of the hose is required call MAHLE. Page

PARTS IDENTIFICATI P/N Description 060-869-00 Top Cylinder Plate 060-869-00 Bottom Cylinder Plate 060-8695-00 Fiberglass Tube (5 inches) 4 05-84-00 Tank Level Decal 5 08-80465-00 Large O-Ring 6 06-808-00 Vacuum Gauge 0"-0 PSIG 7 0-8008-00 Ball Valve -Way /4 FPT (BHD) 8 08-808-00 Small O-Ring 9 0-80-00 -way dual valve 0 0-8060-00 Valve Relief /4 MPT X /4 FPT 9 0 Waste 4 70-800-0 Clear Hose Assy 06-8097-00 Vacuum Pump (Venturi) 70-80075-00 Pressure Regulator /4 FPT X /4 FPT (BHD) 4 060-85-00 Cone Plug Adapter 5 70-8068-00 Cone Adapter Valve Assy 6 6 70-80095-00 Adapter Hose 7 5 8 6 4 5 Page 4

FLOW Page 5

This Page Intentionally Blank Page 6