AIR HANDLER SPECIFICATION

Similar documents
Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

1.1 This section applies to air handling units for HVAC Systems.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

SECTION AIR HANDLING UNIT

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

AIR HANDLING UNITS. Revision AG 16-07

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

University of Delaware

TYPICAL CPA SPECIFICATIONS

SECTION FAN COIL UNITS

Centeral Station Air Handling Unit

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Chilled Water DOAS Fan Powered Terminal Units

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SECTION AIR COILS

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

A. Codes and Standards that are Standard at the University:

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

Advance Release September 2009

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Direct Fired Heater Model AD Specification

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

EHH SERIES DRAW THROUGH FAN COILS CFM

Modular Supply Make-Up Air Unit

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

A. This Section includes air-handling units with coils for indoor installations.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

SECTION AIR COILS

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Modular Heating & Ventilating Unit Model IGX-HV

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SSL & SBS Engineering Guide

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

KIC Air Curtains. Technical Guide

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Double Skin Casing Air Handling Units

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Construction Standards Page

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

KAP Horizontal Product Coolers

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

SECTION CENTRAL HVAC EQUIPMENT

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

JCseries EVAPORATIVE CONDENSER. engineering data

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

MAC N-407 Air-Cooled Chiller

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MLR SERIES MODULAR AIR HANDLING UNITS

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

PRODUCT CATALOG BLOWER COILS.

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Cabinet Unit Heaters Steam / Hot Water

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

ENGINEERING & SERVICE

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

C13-Series Engineering Guide

GUIDE SPECIFICATIONS AQUARIUS ii

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

FT900BD FLIGHT-TYPE DISHWASHER

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Transcription:

AIR HANDLER SPECIFICATION Air Handlers AH-1 through 5 The following air handlers will be supplied: AH-1 FX15-4842 Series 5700 CFM AH-2 FX15-4236 Series 3990 CFM AH-3 FX15-3633 Series 2570 CFM AH-4 FX15-3330 Series 1450 CFM AH-5 FX15-4236 Series 3740 CFM A. General 1. Air handlers shall be Aqua-Air factory assembled. Units will consist of a filter/mixing box section, chilled water coil, mist eliminator ( if necessary ), humidifier and blower/motor section. 2. Units shall be shipped fully assembled. All motorized water regulating valves and humidifier modules will be shipped loose. B. Unit Cabinet 1. Unit panels shall be constructed of 1" thick foam core panels. The outer sheathing on the panels is aluminum. Casing panels shall be removable for easy access to the internal components. Bolts and screws used shall be stainless steel. 2. Access doors shall be of 1" thick foam core panels. Each will be equipped with a minimum of two latching mechanisms. 3. Casing shall be constructed of the 1" thick foam core panels 4. Casing exteriors shall be painted to meet 500 hour salt spray requirement. Color shall be Awlgrip Matterhorn White.

5. Framework for the unit will be constructed of extruded aluminum material with cast aluminum corners. The framework on the discharge side of the cooling coil will be insulated internally to prevent external condensation and to prevent the transmission of noise. C. Fan Section 1. Fan section shall be constructed of insulated aluminum framework and panels and have a formed channel base for integral mounting of fan assembly and casing panels. Fan scroll, wheel, shaft, bearings, drives and motor shall be mounted on a galvanized steel assembly which shall be isolated from the outer casing with rubber vibration isolators and vibration absorbent fan discharge seal. A removable access door will be provided on the designated access side of the unit. 2. Each unit shall have one fan wheel and scroll only. Fans shall be double width, double inlet type with forward curved blades. Blower wheels shall be bonderized galvanized steel. Blower housings are constructed of galvanized steel. 3. Fan wheels shall be keyed to the shaft and shall be designed for continuous operation at the maximum rated fan speed and motor horsepower. 4. Fan shafts shall be solid steel, turned, ground, polished and coated with a rust preventative oil. Access doors shall be provided so that the shaft can be removed without removal of casing panels. 5. Fan bearings shall be self-aligning, pillow-block regreasable ball- or roller-type selected for a minimum average life of 20,000 hours. 6. The motor shall be mounted within the fan section casing on slide rails having an adjustable screw. Motors shall be open, drip-proof NEMA Design B or TEFC type. Motors shall be mounted on a horizontal flat surface and shall not be supported by the fan or its structural members. Each motor will be tested in the assembled unit with voltage

and amp readings verified. 7. Motors shall be 460-3-60. D. Coil Sections 1. The coil sections shall be constructed of insulated aluminum panels. All coils must be easily removed from the side of the unit. The main drain pan shall have a inner pan of stainless steel with a 1/2" insulation barrier between the inner pan and the outer steel housing. A minimum of four 1-1/8" OD drains shall be supplied on each drain pan. Drain pan internal depth to be no less than 2". 2. All coils shall be tested at 400-psig air pressure while submerged in water. Coil performance shall be in accordance with ARI Standard 410. All coils shall have stainless steel casings as standard. 3. Chilled water coils shall be copper plate fin type with belled collars and shall be bonded to 5/8" OD copper tubes by mechanical expansion. Coils shall have copper headers with MPT connections. Working pressure shall be 300 psig at 200 F. 4. Coils shall be drainable and have non-trapping circuits. No turbulence promoting devices will be permitted inside the tubes. Headers shall have drain and vent connections. Vents and drains that are installed in coil return or supply bends promote coil tube fatigue and shall not be allowed. Coil nozzles and headers shall be of the same material.

E. Filter Section 1. Each filter section shall be designed and constructed to house one or more 4" thick return air filter(s) of standard size. F. Mist Eliminators 1. Units whose cooling coil air flow face velocity exceeds 500 FPM will be supplied with mist eliminators. 2. The unit mist eliminator will be constructed of extruded polypropylene profiles mounted in a stainless steel frame. 3. All condensate removed from the air stream by the mist eliminator will drain into the extended drain pan that is under the cooling coil, mist eliminator and humidifier dispersion tube. G. Sensors 1. Unit will be equipped with the appropriate return air, outside air, supply air and filter pressure differential sensors as necessary. 2. Unit will be equipped with a pressure differential type air flow switch to provide positive fan interlock. 3. Unit will be equipped with a pressure differential type air flow switch to provide verification of a clean filter. H. Humidifier 1 Each air handler will be supplied with an appropriately sized steam humidifier. 2 The humidifier will be a self-generating electrode type utilizing a plastic cylinder with full probes connected to electric power via electrode screw connectors. 3 The electrodes will be constructed of low carbon steel, zinc plated and dynamically formed for precise current control and cleanability. Electrodes will be compatible with 460-3-60 power.

4. The humidifier will be a UL listed product. The cylinder shall be made from UL approved plastic with a removable drain screen for easy maintenance and inspection. 5. The humidifier cabinet shall be constructed of 16 gauge steel and shall be painted and corrosion protected on both sides for added protection. 6. The humidifier will introduce steam into the air handler via a stainless steel distributor tube mounted in the air stream after the mist eliminator. 7. Control of the humidifier will be via a microprocessor that shall provide modulating output based on a proportional signal received from a humidistat located in the return air to the air handler. i:\wordpfct\03022201-air handler spec.wpd