FT14 Ball Float Steam Trap (Screwed)

Similar documents
FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

MFP14 Automatic pumps. for condensate and other industrial fluids

MFP14 Automatic pumps for condensate and other industrial fluids

Liquid Drainers LIQUID DRAINERS

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Installation and Maintenance Manual

ESCO. Committed. Group of Companies. to help conserve Steam Energy

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

STEAM TRAPS

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

SMK 22 SMK SMK SMK 22-82

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

Inverted Bucket Steam Traps

THERMOSTATIC STEAM TRAPS

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

THERMODYNAMIC STEAM TRAP

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

BK 46. Installation Instructions Steam Trap BK 46

CRU-S Series Stainless Steel Condensate Recovery Unit

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Model: 1100 Float-Controlled Condensate Trap, PN 25

THERMODYNAMIC STEAM TRAPS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

LIQUIDATOR UMT-TD Series Thermodynamic

LIQUIDATOR 450 SERIES

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

STEAM EQUIPMENT 4

UNIVERSAL STYLE STEAM TRAPS WU450 Series

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

CD-33/CD-33S Controlled Disc Steam Traps

GESTRA. Program for Universal Connections. The Smart Solutions

INSTALLATION, OPERATION

THERMODYNAMIC STEAM TRAPS

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

205 Control Installation and Maintenance Instructions

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Pump & Trap Combinations

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

SECTION STEAM CONDENSATE PUMPS

CRU 200 and 500 Series Condensate Recovery Units

EasiHeat Mechanical Installation and Commissioning Instructions

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

Air Vents AV-392. Proven Same proven, free-floating all stainless steel mechanism as used in Armstrong steam traps.

THE PIVOTROL PUMP (Patented) Featuring Reliable PowerPivot Technology

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller for steam (PN 25) AVT / VGS - external thread

CHLORIDE GASES CHLORIDES

INSTALLATION, OPERATION

Hoffman Specialty General Catalog

BK 45 BK 45-U BK 45-LT BK 46

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Silhouette. Feedwater Heater. Boiler Feedwater

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

Spirax-Sarco Industrial Thermostatic Steam Traps

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Technical Specification

Instructions for Installation, Operation, Care and Maintenance

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

TVA Flowmeter for Saturated and Superheated Steam Service Installation and Maintenance Instructions

Technical Specification

Steam Traps and Steam Trap Testing

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

LIQUID ELIMINATORS/ FLOAT TYPE LIQUID DRAINERS

Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

INSTALLATION, OPERATION

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Technical Specification

Product overview. the optimum components for every application

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Our Know-How. Your Peace of Mind. Steam Solutions

Welcome! Today s topic: Small Home Repairs. November 14, 2015

SECTION Pipeline Ancillaries

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

Spiratec Steam trap monitoring

Technical Specification

Transcription:

Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals and integral automatic air venting facility. The FT14 can be maintained without disturbing the pipework. Available types FT14 (R-L) FT14 (L-R) FT14V Horizontal connections with flow from right to left Horizontal connections with flow from left to right Vertical connections with flow downwards FT14-C (R-L) 20 19 21 Capsule The BP99/2 capsule which is used in the FT14 is suitable for use on 150 C superheat @ 0 bar g and 50 C superheat @ 2 bar g. Optional extras A manually adjustable needle valve (designated 'C' on the nomenclature i.e. FT14-C) can be fitted to the trap. This option provides a steam lock release (SLR) feature in addition to the standard air vent. For further information please consult Spirax Sarco. The FT14 has the option of an integral strainer screen (designated 'X' on the nomenclature i.e. FT14-X). Standards This product fully complies with the requirements of the uropean Pressure quipment Directive 97 / 2 / C. Certification This product is available with a manufacturers Typical Test Report. Note: All certification/inspection requirements must be stated at the time of order placement. Sizes and pipe connections ½", ¾" and 1" screwed BSP or NPT. 8 4 17 6 2 1 7 5 6 Pressure/temperature limits (ISO 6552) Temperature C Steam saturation curve The product must not be used in this region. Body design conditions Pressure bar g PN16 PMA Maximum allowable pressure 16 bar g @ 100 C TMA Maximum allowable temperature Minimum allowable temperature Maximum operating pressure PMO for saturated steam service TMO Maximum operating temperature -10 C 14 bar g Minimum operating temperature 0 C Maximum FT14-4.5 4.5 bar PMX differential FT14-10 10 bar pressure FT14-14 14 bar Designed for a maximum cold hydraulic test pressure of 24 bar g 28 12 Main valve assembly 1" Materials No. Part FT14 (R-L) Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 2007 11 10 Material * 1 Body SG iron DIN 169 GGG 40 2 Cover bolts Steel BS 692 Gr.8.8 Cover gasket Reinforced exfoliated graphite 4 Cover SG iron DIN 169 GGG 40 5 Valve seat Stainless steel BS 970 41 S29 6 Valve seat gasket Stainless steel BS 1449 409 S19 7 Pivot frame assembly screws Stainless steel BS 6105 Cl A2-70 8 Ball float and lever Stainless steel BS 1449 04 S16 10 Pivot frame Stainless steel BS 1449 04 S16 11 Pivot pin Stainless steel * 12 rosion deflector (1" only) Stainless steel BS 970 41 S29 17 Air vent assembly Stainless steel 18 Air vent gasket Stainless steel BS 1449 409 S19 19 SLR assembly Stainless steel BS 970 0 S21 20 SLR gasket Stainless steel BS 1449 04 S16 21 SLR seal Graphite 28 Valve spring (1" only) Stainless steel BS 2056 02 S26 * Note: Item 12 is pressed into item 1 (1" only).

Page 2 of Capacities Condensate kg/h Differential pressure bar (x 100 = kpa) Capacities shown above are based on condensate at saturation temperature. When discharging sub-cooled condensate the air vent provides extra capacity. Under start-up conditions when the condensate is cold the internal thermostatic air vent will be open and provides additional capacity to the main valve. On 4.5 bar units this will provide a minimum of 50% increased capacity above the hot condensate figures shown. On 10 and 14 bar units this will be a minimum increase of 100% on the published capacity. The following table gives the minimum additional cold water capacities from the air vent. P (bar) 0.5 1 2 4.5 7 10 14 Minimum additional cold water capacity (kg/ h) ½" and ¾" 70 140 250 80 560 870 1 10 1 500 1" 120 240 60 500 640 920 1 220 1 500 FT14 Ball Float Steam Trap (Screwed) TI-S02-0 ST Issue 9

Page of Dimensions/weights (approximate) in mm and kg Size A B B1 C D Withdrawal distance F Weight ½" 121 107 96 67 147 105 0 2.9 ¾" 121 107 96 67 147 105 0 2.9 1" 145 107 117 75 166 110 2 4.0 A D C B B1 F FT14-C Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-S02-1) supplied with the product. Installation note: The FT14 must be installed with the direction of flow as indicated on the body, and with the float arm in a horizontal plain so that it rises and falls vertically. If required the flow orientation can be changed on site. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken. How to order xample: 1 off Spirax Sarco ½" FT14-4.5 (R-L) ball float steam trap with screwed BSP connections and integral air vent. Spare parts The spare parts available are shown in solid outline. Parts drawn in broken line are not supplied as spares. Available spares Main valve assembly with float, 5, 6, 7 (2 off), 8, 10, 11, 16 (1" only) Air vent assembly, 17, 18 Steam lock release and air vent assembly, 17, 18, 19, 20, 21 Cover gasket (packet of ) Maintenance kit, 5, 6, 7 (2 off), 8, 10, 11, 17, 18, 28 (1" only) How to order spares Always order spares by using the description given in the column headed 'Available spares' and state the size, type of trap and pressure range. xample: 1 - Main valve assembly for a Spirax Sarco ½" FT14-10 ball float steam trap. Steam lock release assembly Air vent assembly Recommended tightening torques 19 + 21 20 18 17 or Item N m mm 2 17 A/F M10 x 0 47-50 5 17 A/F 50-55 7 Pozidrive M4 x 6 2.5 -.0 17 17 A/F 50-55 19 and 21 19 A/F 50-55 2 6 5 11 10 7 28 8 Main valve assembly Note: Item 28 is required for 1" size only FT14 Ball Float Steam Trap (Screwed) TI-S02-0 ST Issue 9

Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. Copyright 201 FT14 Ball Float Steam Trap (Flanged) TI-S02-26 ST Issue 7 Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals and integral automatic air venting facility. The FT14 can be maintained without disturbing the pipework. Available types FT14 (R-L) Horizontal connections with flow from right to left FT14 (L-R) Horizontal connections with flow from left to right Please note: On the cover of both of these traps, the orientation of the connections can be adjusted on site in preparation of downward vertical flow applications. Capsule The BP99 / 2 capsule which is used in the FT14 is suitable for use on 150 C superheat @ 0 bar g and 50 C superheat @ 2 bar g. Optional extras A manually adjustable needle valve (designated 'C' on the nomenclature i.e. FT14-C) can be fitted to the trap. This option provides a steam lock release (SLR) feature in addition to the standard air vent. For further information please consult Spirax Sarco. The FT14 has the option of an integral strainer screen (designated 'X' on the nomenclature i.e. FT14-X). Standards This product fully complies with the requirements of the uropean Pressure quipment Directive 97 / 2 / C. Certification This product is available with a manufacturers' Typical Test Report. Note: All certification / inspection requirements must be stated at the time of order placement. Sizes and pipe connections DN15, DN20 and DN25 Flanged N 1092 PN16, ASM 150 and JIS/KS 20. FT14 (R-L) FT14-C (R-L) 28 12 8 4 17 18 20 19 21 11 10 2 1 7 5 Pressure/temperature limits (ISO 6552) Temperature C 250 200 150 100 50 0 0 Steam saturation curve The product must not be used in this region. Body design conditions 2 4 6 8 10 12 14 16 Pressure bar g PN16 PMA Maximum allowable pressure 16 bar g @ 100 C TMA Maximum allowable temperature Minimum allowable temperature Maximum operating pressure PMO for saturated steam service TMO Maximum operating temperature -10 C 14 bar g Minimum operating temperature 0 C Maximum FT14-4.5 4.5 bar PMX differential FT14-10 10 bar pressure FT14-14 14 bar Designed for a maximum cold hydraulic test pressure of 24 bar g Main valve assembly DN25 Materials No. Part Material * 1 Body SG iron DIN 169 GGG 40 2 Cover bolts Steel BS 692 Gr. 8.8 Cover gasket Reinforced exfoliated graphite 4 Cover SG iron DIN 169 GGG 40 5 Valve seat Stainless steel BS 970 41 S29 6 Valve seat gasket Stainless steel BS 1449 409 S19 7 Pivot frame assembly screws Stainless steel BS 6105 Cl A2-70 8 Ball float and lever Stainless steel BS 1449 04 S16 10 Pivot frame Stainless steel BS 1449 04 S16 11 Pivot pin Stainless steel * 12 rosion deflector (DN25 only) Stainless steel BS 970 41 S29 17 Air vent assembly Stainless steel BS 1449 04 S19 18 Air vent seat gasket Stainless steel BS 1449 409 S19 19 SLR assembly Stainless steel BS 970 0 S21 20 SLR gasket Stainless steel BS 1449 04 S16 21 SLR seal Graphite 28 Valve spring (DN25 only) Stainless steel BS 2056 02 S26 * Note: Item 12 is pressed into item 1 (DN25 only). Page 1 of

Capacities 1 500 1 000 DN25 FT14-4.5 500 400 00 DN25 FT14-10 DN15 and DN20 FT14-4.5 Condensate kg/h 200 100 DN25 FT14-14 DN15 and DN20 FT14-10 DN15 and DN20 FT14-14 50 40 0 0.1 0.2 0. 0.4 0.5 1 2 4 5 10 14 Differential pressure bar (x 100 = kpa) Capacities shown above are based on condensate at saturation temperature. When discharging sub-cooled condensate the air vent provides extra capacity. Under start-up conditions when the condensate is cold the internal thermostatic air vent will be open and provides additional capacity to the main valve. On 4.5 bar units this will provide a minimum of 50% increased capacity above the hot condensate figures shown. On 10 and 14 bar units this will be a minimum increase of 100% on the published capacity. The following table gives the minimum additional cold water capacities from the air vent. DP (bar) 0.5 1 2 4.5 7 10 14 Minimum additional cold water capacity (kg/ h) DN15 and DN20 70 140 250 80 560 870 1 10 1 500 DN25 120 240 60 500 640 920 1 220 1 500 TI-S02-26 ST Issue 7 FT14 Ball Float Steam Trap (Flanged) Page 2 of

Dimensions/weights (approximate) in mm and kg Size A A B C D F G Weight PN/ASM JIS/KS Withdrawal distance DN15 150 150 107 101 51 47 26.5 115 4.5 DN20 150 150 107 101 55 47 26.5 115 5.0 DN25 160 170 117 70 100 10 21.0 120 6.5 DN15 and DN20 DN25 B A D C G D C G FT14-C F Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-S02-1) supplied with the product. Installation note: The FT14 must be installed with the direction of flow as indicated on the body, and with the float arm in a horizontal plain so that it rises and falls vertically. If required the flow orientation can be changed on site. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken. How to order xample: 1 off Spirax Sarco DN25 FT14-4.5 (R-L) ball float steam trap with flanged PN16 connections and integral air vent. Spare parts The spare parts available are shown in solid outline. Parts drawn in broken line are not supplied as spares. Available spares Main valve assembly with float, 5, 6, 7 (2 off), 8, 10, 11, 28 (DN25 only) Air vent assembly, 17, 18 Steam lock release and air vent assembly, 17, 18, 19, 20, 21 Cover gasket (packet of ) Maintenance kit, 5, 6, 7 (2 off), 8, 10, 11, 17, 18, 28 (DN25 only) How to order spares Always order spares by using the description given in the column headed 'Available spares' and state the size, type of trap and pressure range. xample: 1 - Main valve assembly for a Spirax Sarco DN25 FT14-10 ball float steam trap. Steam lock release assembly 19 + 21 20 Air vent assembly 18 17 Recommended tightening torques or Item N m mm 2 17 A/F M10 x 0 47-50 5 17 A/F 50-55 7 Pozidrive M4 x 6 2.5 -.0 17 17 A/F 50-55 19 and 21 19 A/F 50-55 2 6 5 11 10 7 28 8 Main valve assembly Note: Item 28 is required for DN25 size only TI-S02-26 ST Issue 7 FT14 Ball Float Steam Trap (Flanged) Page of