END STATION REFRIGERATION SYSTEM

Similar documents
Cryogenics. Overview of the Jefferson Lab 12GeV Upgrade. J. Creel, K. Dixon, P. Knudsen, J. Wilson Jr.

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Air Liquide Advanced Technologies Division Sassenage, 38360, France

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

FRIB Cryogenic Distribution System and Status

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

THE TORE SUPRA CRYOGENIC SYSTEM. Design and operation

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

A. Martinez, A. L. Klebaner, J. C. Theilacker, B. D. DeGraff, and J. Leibfritz. Fermi National Accelerator Laboratory Batavia, IL, 60510, USA

W. T. Roybal J. T. Bradley III D. E. Rees P. Torrez D. K. Warner J. Debaca. LINAC 2000 Monterey, CA August ,2000

AVAILABILITY AND RELIABILITY OF CERN CRYOPLANTS

3.2 Cryoplant and Cryodistribution

Available online at ScienceDirect. Physics Procedia 67 (2015 )

FINAL ABSTRACT. CRADA TITLE. Miniature Transducers for Flight Test Unit Instrumentation - Magnetic Field Detector CRADA NUMBER: LA98C10367.

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

.2 Section Waste Management and Disposal.

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

HELIAL refrigerators. Range of automatic helium refrigerators

Reconfiguration of a B&W/SSC/LINDE Liquefier to Meet SLAC-BaBar Detector Magnet Requirements * Abstract

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

A CRYOGENIC TEST STATION FOR SUBCOOLING HELIUM HEAT EXCHANGERS FOR LHC

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

Electronic Refrigerant Leak Detector DE-FG36-98G Micronic, Inc. Elie Talamas, Jr. Period: 10/1/99 to 12/31/99

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Development of a measurement and control system for a 10 K refrigerator based on Siemens PLC S7-300

SPECIFICATION OF FOUR NEW LARGE 4.5 K HELIUM REFRIGERATORS FOR THE LHC

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Liquid Helium Level Instruments

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

OPERATIONAL EXPERIENCE ON CRYOGENIC SYSTEMS FOR LARGE-SCALE ACCELERATORS AT CERN

Condensate Induced Water Hammer in a Steam Distribution System Results in Fatality

BuildingName The Description of the Project P DOCUMENTS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Hybrid Refrigerated/Desiccant Compressed Air Dryers

MODEL MW200 MODEL MW600 AIR DRYER

Installation Operation Maintenance

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Cryogenics for Neutral Beam Injector System

POWER GENySYS P ROJECT E XPERIENCE I NFORMATION - D ISTRIBUTED G ENERATION

SECTION AIR COMPRESSORS AND ACCESSORIES

Maintenance and Reliability Design Aspects SNS 2K Refrigeration System

Measured Performance of Four New 18 K Helium Refrigerators for the LHC Cryogenic System

Food Service Technology Center

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Vacuum Insulated Pipe

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

THERMAL ICE STORAGE: Application & Design Guide

/,6 REMOTE MONITORING DESIGN CONCEPTS FOR SPENT FUEL STORAGE FACILITIES

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

10 K Airborne Cryocooler and

Nitrogen Generation Systems Compressed Air Dryers

STER 1981 ANNUAL INDUSTRIAL SUMMARY OF FIRE AND PROPERTY DAMAGE EXPERIENCE. Monsanto. MOUND FACILITY Miemisburg. Ohio MLM.ML

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

CPC PRODUCT DESCRIPTION

TECHNICAL. Series 18. Pump Packages

Benefits of Desiccant Dryer Dew Point & Purge Control

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

OPERATING MANUAL Enertronic Control System 2

Southern California Gas Company Customer Programs Department

CONTENTS. B. System Design and Performance Requirements

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Experimental Assessment of the Thermal Performance of Storage Canisterm01d ing Fix ture Conj?gurations

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Automation and Energy Efficiency of Industrial Refrigeration Systems

Guide Specifications

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

CPVS PRODUCT DESCRIPTION

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER I: AUXILIARY SYSTEMS 2. COMPONENT COOLING SYSTEM FOR THE NUCLEAR ISLAND (RRI [CCWS])

Why Thermostats Matter

Advances in Liquid Nitrogen (LN 2 ) Based Lyophilization Technologies

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC)

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:

Linde Kryotechnik AG. The new standard for helium liquefiers and refrigerators.

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Remote Helium Cooling Loops for Laboratory Applications

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

DuPont Formacel Z-2. Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications FOAM EXPANSION AGENT TECHNICAL INFORMATION

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Dual Tower Heat Reactivated Desiccant Air Dryer

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

Transcription:

END STATION REFRIGERATION SYSTEM D. Arenius, B. Bevins, W.C. Chronis, V. Ganni D. Kashy, M. Keesee, J. Wilson Jr. Cryogenic Systems Group Continuous Electron Beam Accelerator Facility Newport News, Virginia, 23606,USA ABSTRACT The CEBAF End Station Helium Refrigerator (ESR) System 1 provides refrigeration at 80 K, 20 K and 4.5 K to three End Station experimental halls. The facility consists of a two stage helium screw compressor system, 4.5 K refiigerator, cryogen distribution valve box, and transfer lines to the individual experimental halls. The 4.5 K cold box and compressors were orighally part of the ESCAR 1500 W, 4 K refiigeration system at Lawrence Berkeley Laboratory which was first commissioned in 1977. The compressors, 4.5 K cold box, and control system design were modified to adapt the plant for the requirements of the CEBAF experimental halls. Additional subsystems of cryogen distribution, transfer lines 2, warm gas manalgement, and computer control interface were added. This paper describes the major plant subsystems, modifications, operational experiences and performance. INTRODUCTION The End Station Refrigerator is one of three CEBAF cryogenic facilities. These facilities are the Central Helium Liquefier (CHL), located in the center of the accelerator; the End Station Ftefrigerator (ESR), located next to the End Stations Halls A, B and C; and Cryogenic Test Facility Liquefier (CTF) which is located adjacent to the Cryomodule Test Laboratory. W i l e the purpose of the CHL and CTF is to provide cryogens to superconducting cavities in the accelerator ring and testing areas, the ESR is designed to provide cryogens to the CEBAF experimental halls. These halls have superconducting magnets, cryogenic targets and various equipment which require refiigeration at 4.5 K, 20 K, and 80 K. The ESR can provide refrigeration to one or all three halls with at any given time. '...

DISCLAIMER Portions of this document may be illegible in electronic image products. Images are produced from the best available original document.

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not ncccssarily state or reflect those of the United States Government or any agency thereof.

Table 1. End Station Cryogenic Heat Load Budget I Hall A Hall B Hall C Device Lead Flow Magnet Transfer Line Cryotarget 64 UHR Torus Magnet Transfer Line Cryotarget 40 WHR Magnets Transfer Line Cryotarget 60 WHR * Unknown -NA-NA- -NA-NA- -NA-NA- 4K 130 W 76 W 20 K 80K unk* 250 W w w ow 50 w 220 20 unk* 135 W 46 W 400 W 50 W 30 W ow 250 W -NA- not appliable ESR Cryogenic Heat Loads. The three Experimental End Stations (Halls) contain superconducting quadrupole magnets, a large six coil toroid, and miscellaneous user's equipment. The CEBAF End Station cryogenic refrigeration load allowance3 for the experimental halls is presented in Table 1. These requirements include refrigeration at 4.5 K, 20 K, and 80 K. The 80 K refrigeration is provided by LN2 fiom the CHL. The CHL LN2 storage capacity is 75,700 L. The CHL, facility also provides gaseous helium storage and puritication for the facility. The ESR facility can accept 10 G/Sat 4.5 K and 2.8 bar fiom the CHL as a secondary helium cryogen source for the End Stations. Refrigerator History. The refrigerator (cold box) was originally designed for Lawrence Berkeley Laboratory (LBL) in 1977 for two principle modes of operations. As a liquefier, it provided 11.7 G/Sat 4.42 I(.In the refrigerator mode, it was designed to provide 1450 watts of refigeration and 3 G/S of liquid at 4.42 K. The refrigerator was one of two identical refiigerators which were built at approximately the same time for separate laboratories. At the second laboratory the refrigerator had a performance design mode requirement which could provide 950 watts of refrigeration plus 1.7 G/S of liquid at 4.42 K and 1250 W at 21.5 K. The second plant, at FERMI, is still in operation today. In June of 1990 the refrigerator system was shipped to CEBAF from LBL. The shipment included the compressor skids, motor starters, a local analog control console, 10,000 L helium dewar, and the refrigerator. The plant was placed into storage until the building for the plant could be finished. An outline of the plant's history is presented in Table 2. '-..

- LBL Table 2. ESR System Timeline SYSTEM Compressors Received Coldbox Recieved Acceptance Test Last Used At LBL CEBAF :LBL System Received Installation Start Cornpressor Startup Cold Box Startup CEBAF Modifications Gas Management, Utilities Refiigerator Controls Compressor Contrclflubing Cold Box LN2 Boiler Installation External 80 K Purifier Beds Cold Box 4.5 K Separater/Subcooler Dewar Internal Subcooler Compressor Oil Coolers Spare Compressor DATE REMARKS Aug-76 Jun-77 NOV-77 Sept-8-960 hours Jun-90 Feb-92 JuIy-94 Dec-94-3300 hours to date -2000 hours to date Feb-92 Feb-92 Jun-92 Jun-94 Feb-95 Jun-95 JuI-95 JuI-95 Aug-95 New To System PLC and Computer PLCNelded Lines New To System New To System New To System New To System Replacement New to System The number of operating hours at LBL were less than 1000 hours and the refiigerator had been inactive from 1981 until 1994. The technical concerns were therefore centered on the condlition and rehrbishing of the major equipment. This included the compressor motors, motor starters, compressors, control system and the turbine expanders. Consideration was given to the anticipated maintainablity and the experiences of the LBL operations. Many of the component manufacturers, including the turbine expanders and compressors, were still providing spare parts. Original LBL spare parts were transfered to CEBAF with the refrigerator and compressors. Other spares, such as turbine cartridges,were purchased later by CEBAF. Much of the initial operational maintenance insight fcr the plant came fiom the LBL logbooks, documentation and operator's manual. New subsystems were also needed for the CEBAF facility. This included a cooling water system, electrical distribut.ion, cryogen distribution valve box, transfer lines2, compressor oil removal, gas management, instrument air, gas contamination monitoring, and computer interface cabinets. Design, fabrication, and installation of the system modifications and new subsystems were performed by CEBAF personnel.

CEBAF PROCESS DESCRIPTION Overall Design The: CEBAF End Station Refrigerator System is presented in Figure 1 for the CEBAJ? full 4.5 EC refrigeration design capacity mode. Two stages of compressors compress helium fiom 1 bar to 17 bar with a discharge flow rate of 214 GIs. During cooldown, system makeup #gasis brought into the compressor system interstage or first stage suction at 2.5 bar or 1 bar respectively. A 2nd stage discharge massout control valve provides the means to remove excess gas from the system during a warmup process. Compressor bypass valves are provided around each stage to regulate the compressor suction pressures. Flow from the refrigerator returns 113 G/S to the interstage and 101 G/S to the first stage compressor suction. The compressor discharge flow enters the refrigerator where 5 G/Sis diverted to a GN2 vent warmup heat exchanger. The diverted flow is then recombined with the main high pressure flow. The flow stream is then precooled in a LN2 pool boiling heat exchanger to 80 K, passing through one of two new 80 K adsorber beds. As the discharge flow continues through the reftigerator 113 G/S is diverted through the upper turbine at an inlet temperature of 18.5 K. The turbine flow exhausts at 2.5 bar and 12 K and is returned to the interstage of the compressor system. The remaining 101 G/S flow is expanded through a parallel combination of the lower turbine (75 G/S) and a bypass valve (26 G/S)to 2.9 bar and 5.7 K. The process flow is then subcooled to 4.5 K by utilizing 10 g/s of the process stream in a new subcooler/phase separator which is internal to the refrigerator. Additional subcooling capacity is provided by a 10,000 L liquid helium dewar which was modified with internal cooling coils. A refrigerator process connection is provided for supplying 15 K He to fbture hall cryogenic target loads at reduced 4.5 K refrigeration loads. The target load flow returns via a 20 K refrigeration process return connection to the refrigerator interstage at 2.5 bar. Compressor System The: compressor system is comprised of two stages of oil flooded screw compressors. Each stage has a single electrically driven compressor and was a part of the original LBL facility. The first stage is a 3600 rpm, 150 KW Sullair C-25-LB compressor. The second stage is 81 3600 rpm, 750 KW Sullair C-25-LA compressor. Each compressor is mounted on an individual skid with an oil cooler, bulk oil separator, 480 volt drive motor, local control panel and a gaseous helium aftercooler. The original compressor skid mounted relay logic control panels, instrumentation, instrument tubing, and oil injection lines were replaced. This was to eliminate threaded and compression fittings as possible sources of system contamination. A small programmable control system was installed on each compressor skid and integated with the CEBAF computer control system for unattended operation. The remodeled compressor controls have worked very well with the exception of an initial loose control fuse holder which resilted in a few sparatic compressor trips. c -

I I I I GN2 VENT )HX-lA{ 11 I I GHe STORAGE ---- 1 HX-1 I I COMPRESSORS 1 REFRIGERATOR 1 '..!'_. W A S SEPARATOR / SU2C:COLER "pc LN2 STORAGE EXPERIMENTAL HALLS FI'GURE 1 ESR Facility Simplified Flow Diagram indicating the major subsystems of compressors, refrigerator, liquid helium dewar and distribution valve box.

The first stage compressor and the40ilcoolers of both stages were disassembled and inspected for possible corrosion which may have occurred during the system inactivity and storage period. There was very little corrosion evident. Compressor oil seals, oil, and motor bearings were routinely replaced. Initial static motor winding testing indicated no adnormaliities. After approximately 1000 hours of compressor operation, however, both the first and second stage motors required rewinding or replacement because of the development of electrical winding failures. The second stage compressor motor has been increased fiom a 600 KW to a 750 KW drive to allow for a larger operational load margin. The compressor gas management system is a new design. The system utilizes relatively small equal percentage gas makeup valves (<25 G/S). This provides a finer degree of control during normal cooldown or steady state refiigeration operations. The compressor bypass valves were sized for the compressor startup and system pressure building phase of operation, During this phase of operation the valves must bypass approximately 40 percent of the design flow with a fblly unloaded compressor and low initial compressor differential pressure. This conservative design approach allows compressor starting when the available helium makeup gas storage pressures are relatively low. There has not been any difficulties associated with the gas management control system. Flow orifice plates were installed on each main process flow stream to the refrigerator. Additionail flow instrumentation provisions were made to test the performance of the compressors independently of the operation of the refrigerator. This was accomplished by placing flow orifice plates upsteam of each of the compressor bypass valves. A performance check of the compressor cperation indicated nominal design flow rates with a flow balance indication error of 3 percent. A new compressor oil removal system consisting of three stages of Monsanto oil coalescers, a single stage of carbon adsorber and a final particulate filter were added. Although the design allows the oil to be returned to either compressor stage, the oil is normally returned to the fiist stage since there is a normal oil carry-over fiom the first to the second stage compressor. Similiar oil removal systems used at CEBAF have been in continuous operation for eight years with great success. The oil removal system is fhnctionirrg well with the majority of the oil removal occurring in the compressor bulk oil separator and the first coalescer. During the initial running of the compressors at CEBAF the water contamination level in the heliuim gas process stream increased whenever the compressors were stopped. An investigation showed the compressor oil coolers were of the swaged tube design. Some tubes were leaking cooling water contamination into the helium gas system whenever the helium gas stream pressure was below that of the water system. Successfhl reswaging was completed but replacement oil coolers with a welded tube design were procured as a precautionary measure. Compressor Summary. Currently the compression system, oil removal and gas management are working reliably with 3000 hours of operation. Much of those operational hours were unattended. Improvements, such as the replacement of the oil coolers and the addition of a third compressor (which may used as a first or second stage backup) are being made.

Refrigerator Cointrol System. The refiigerator or cold box was modified in a number of ways. The original control system was based on an obsolete programmable controller. Valve control was actamplished with separate electronic analog controllers. A determination was made that the system would be difficult to maintain due to the age of the devices and the availability of spare parts. The programmable controller system was replaced and the analog controllers were eliminated completely. The new programmable controller requires only 1116th ihe space of the earlier model. It is identical to other controllers which have proven to be reliable at CEBAF. The duplication of the type of controller eliminated additional spare part inventories and personnel training. The former finction of the analog loop controllers was replaced with direct CAMAC computer interface control. The control logic of the fefrigerator was modified to include the LBL operational experiences and concerns. Pressure switches were added to the outlet of the lower turbine to stop the turbine after starting if the outlet pressure drops below 2.3 bar or rises above 5 bar. This safety interlock prevents turbine damage should the downstream turbine flow be restricted or there is a danger of forming liquid on the turbine blades. A pressure equalization valve was formerly designed to automatically depressurize the refrigerator high pressure supply stream whenever a compressor shutdown, power outage, or loss of instrument air occurred. The depressurization was changed to a manual operation to minimize the rate of turbine inlet pressure change as the turbine was being stopped. The former control logic included a vapor pressure thermometer with a pneumatic ampliming relay for an automatic shutdown of the upper turbine in the event its inlet temperature became too cold. The accuracy of the turbine trip point was dependent on the turbine temperature ratio and the hystersis of the pneumatic devices. The design is being modified to monitor the turbine outlet temperature electronically as a more accurate monitoring means. All refrigerator silcon diode temperature sensors were replaced and all critical (controlsensors were spared. The control logic was also modified to isolate the cold box fioim the hall loads in the event of a refiigerator, utility, or compressor loss. 801 K Adsorber Beds. Originally the refiigerator did not have 80 K adsorber beds. Two redundant adsorber beds have been added to the system since the refrigerator is now being used for extended periods of time. The beds have been installed external to the existing cold box and arc connected to the refiigerator by bayonets. Each bed is equipped with isolating valving, regenerative heaters, and instrumentation. An external manual gas management control panel provides the operator with the means to cooldown, warmup, and regenerate the beds. The adsorber beds will be used for the first time in August, 1995. 80 K Precooler. During the LBL plant operations, there was concern about accidently damaging the upper heat exchanger by freezing the LN2 passage of the heat exchanger. Such an event could occur during a helium flow imbalance where excess cold helium gas or liquid was returned through the low pressure return piping of the refiigerator. To prevent this, the LN2 precooling in the upper heat exchanger was eliminated. An existing auxillary internal rapid cooldown heat exchanger is now used in combination with a new LN2 pool boiling heat exchanger to provide helium gas precooling. Flow diverter valving was added to warm c.

the nitrogen venting fiom the refiigerator. Under operation, the new design has performed well and is veiy stable. Phase Separator. During initial CEBAF operation of the refiigerator, the internal phase separator with its liquid helium level instrumentation would not fbnction properly. Liquid was carried over into the refrigerator low pressure return piping, resulting in a rapid oscillating lower turbine outlet pressure. This caused the lower turbine expander to shutdown. A replacement phase separator with a new subcooler has been designed and is presently being installed in the refiigerator. The new separator and subcooler will prevent liquid cairyover and double the existing liquid volume capacity. Refrigerator Summary. The refigerator has been modified with a number of improvements. These have included the addition of a new LN2 precooler, controls, turbine safety interlocks, 80 K adsorber beds, and the design of a new 4.5 K phase separatodsubcooler. The refrigerator has been operated for 2000 hours, utilizing single upper turbine and dual turbine operation. The operations have included cooling the Hall B Torus Magnet and a Hall A dipole magnet to 4 K. During most of these operations, the refrigerator was unattended and it operated reliably. CONCLiUSIONS. c.. The IESR system has been successfblly commissioned. Although some of the major subsystems are approximately 18 years old, there were a number of factors which have helped the commissioning. These include low former operating hours, a design and capacity which ha.d been previously proven suitable for our needs, the equipment was well cared for, and the existance of very accurate documentation of both the equipment and previous operating experiences. ACKNC)WLEDGEMENTS Thle authors would like to thank all the members of the CEBAF Cryogenic Systems Group for their work in the design, fabrication, installation, and operation of the End Station Refiigerrttor Facility. They would like to also extend a special "thank you" to the staff of the CEBAF experimental halls and Lawrence Berkeley Laboratory for their support. This work is supported by DOE Contract #DE-AC05-84ER40150. REFERENCES CEBAF Cryogenics", in: "Advances in Cryogenic Engineering," Vol35A, Plenum Press, New York (1990), p. 275 2. D. Kashy et a], "CEBAF Transfer Line Systems", in: "Advances in Cryogenic Engineering," V o l 3 7 4 Plenum Press, New York ( 1992), p. 577 3. "End Station Parameters", in: "CEBAF Design Handbook," Chapter 6.2.2, Table: 6.23,Rev. January 14, 1991, p. 6.2-4 1. C. H. Rode et al, "2.0 K.

This report has been reproduced from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN $7831; prices available from (615)576-8401, FTS 626-8401. Available to the public from the National Technical Information Service, U.S. Department of Commerce, 5285 Port Royal Rd., Springfield, VA 22161. Price: A02 - Printed Copy Microfiche A01 t