IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTRODUCTION

Similar documents
Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them?

IECEx Certificate of Conformity

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Official Journal of the European Union

EMIRATES CONFORMITY ASSESSMENT SCHEME (ECAS): ECASEx COMPLIANCE

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Explosive atmospheres. IECEx. International Electrotechnical Commission

An Introduction to the IECEx System and IECEx Scheme Certification Processes IECEx Secretariat January 2018

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

HazLoc Essential Guides:

HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

IECEx Certificate of Conform ity

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

Guide to Membership Assessments

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Approvals, Certificates and Conditions

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres?

Official Journal of the European Union

Loss Prevention Standard

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

POLICY FOR THE SAFE WORKING WITH ELECTRICITY

INTERNATIONAL STANDARD

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02)

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

ATEX/05/1/7. In detail:

Changes to Certification and its Impact on Manufacturers. Des McDonell CSE-Ex Pty Ltd

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

CONSULTING Training Courses

INSTRUCTION MANUAL (ATEX / IECEx)

OPTIBAR DP 7060 Supplementary Instructions

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

C 319/6 Official Journal of the European Union

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Australian/New Zealand Standard

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

STANDARDS RELATED MEETING REPORT

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Training, Assessment, Consultants for Hazardous & Industrial Areas

INSTRUCTION MANUAL (ATEX / IECEx)

SUPPLEMENT REPORT No.: XPL/13600/

INTERNATIONAL STANDARD

Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings

Annubar Flowmeter Series

Numerical Standards Listing

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Certificate Surveillance audit

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 092/02)

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

Shipboard incinerators with capacities up to 4000 kw

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IECEx Certificate of Conformity

AS/NZS IEC :2013

IECEx Certificate of Conformity

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

Why manufacturers prefer the IECEx System

VQ500 Series Combustible Gas Detector Elements

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

Certification Supplement Manual

Review / auditing of equipment for technical and Explosion Protection certification suitability;

Electrical Installations Design, Selection, Erection and Inspection

INTERNATIONAL STANDARD

Hazardous Area Zirconia Oxygen Systems

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

AS/NZS IEC 62560:2014

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

The Route to Third Party Certification

Legislation, Standards and Technology. IEC TC 41 Explosion protection of electrical equipment

PRODUCT CONFORMITY CERTIFICATE

AS/NZS :2008

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

IR25 Dual Gas Series Datasheet

Third Party Certification:

Certificate of Compliance

Loss Prevention Standard

Certification Supplement Manual

Transcription:

IEC SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR USE IN EXPLOSIVE ATMOSPHERES (IECEx SCHEME) Ex Management Committee, ExMC TITLE: IECEx Assessment Report for an extension of scope for existing ExCB SIRA INTRODUCTION The IECEx Assessment Team carried out an assessment for an extension of scope during SIRA s reassessment. Outcomes of the reassessment will be finalised during Buxton October 2005 series of meetings. This document contains the IECEx Assessment Report for voting on an extension of scope for existing ExCB SIRA The report is hereby submitted for voting by ExMC Please consider the assessment report and return the completed voting form to the Secretariat by 2005 08 28. Your speedy response to the voting process will be very much appreciated. You may return your completed voting form (available in Word format) via fax or e-mail. Details below. Chris Agius IECEx Secretariat Address: IECEx Secretariat SAI Building 286 Sussex Street Sydney 2000 Australia Tel: +61 2 8206 6940 Fax: +61 2 8206 6272 Email: chris.agius@iecex.com Internet: www.iecex.com Page 1 of 15

IECEx RE-ASSESSMENT AND EXTENSION OF SCOPE REPORT for Accepted Ex Certification Body (ExCB) SIRA 1. OBJECT AND FIELD OF APPLICATION 1.1 Country United Kingdom 1.2 ExCB under Re-Assessment Sira Test & Certification Ltd. 1.3 Members of the Assessment Team Jim Munro, Jim Munro International Compliance Pty Limited, Australia (Lead Assessor) Heinz Berger, CERTICONSULT GmbH, Switzerland (Expert Assessor) 1.4 Place and Date of Re-Assessment Sira Test & Certification Ltd. Hazardous Area Centre Rake Lane Eccleston Chester CH4 9JN U.K. 7 th and 8 th of March, 2005 1.5 Assessment References Documents: i) IECEx 02 Second Edition ii) IECEx Operational Documents e.g. OD/009/V1 iii) ISO/IEC Guide 65 1996 1.6 Current Scope of Acceptance Product Category Standard General Requirements IEC 60079-0 Flameproof IEC 60079-1 Pressurised IEC 60079-2 Quartz/Sand Filled IEC 60079-5 Oil Filled IEC 60079-6 Increased Safety IEC 60079-7 Page 2 of 15

Intrinsic Safety IEC 60079-11 Type n IEC 60079-15 Encapsulation IEC 60079-18 1.7 Extension of Scope Dust (general) IEC 61241-0* Dust (protection td) IEC 61241-1* Dust (protection by enclosure) IEC 61241-1-1 Dust (protection pd) IEC 61241-4 Dust (protection md) IEC 61241-18* Intrinsically safe systems IEC 60079-25* Group II Zone 0 apparatus IEC 60079-26* Fieldbus intrinsically safe (FISCO) IEC 60079-27* Gas detectors (general requirements gas detect) IEC 61779-1 Performance requirements for Group I app IEC 61779-2 Performance requirements for Group I app IEC 61779-3 Performance requirements for Group II app IEC 61779-4 Performance requirements for Group II app IEC 61779-5 Caplights for Group I IEC 62013-1 Trace heating IEC 62086-1 * indicates not covered by current UKAS Accreditation See comment in chapter 14.3 1.8 ExCB Persons Interviewed Name Position M. Shearman General Manager D. Stubbings Certification Manager Ex B. Howard Quality Manager W. Thomas Ex QA Services 1.9 Any changes in Legal Status of the ExCB None. 1.10 Associated Testing Laboratories Names of Laboratories Sira Test & Certification Ltd. Address Rake Lane Eccleston Chester GMI (for 61779 Series and subject to ExMC acceptance of GMI see ExMC/247/DV) Gas Measurement Instruments Ltd Inchinnan Estate, Renfrew, PA4 9RG Scotland Page 3 of 15

1.11 National Marks and Certificates ATEX Certificates issued 1.12 Financial Support Sira Test & Certification Ltd, Hazardous Area Centre, Rake Lane, Eccleston, Chester CH4 9JN, is from the financial point of view a subsidiary of SIRA LTD, South Hill, Chislehurst, Kent, BR7 5EH and is self founded. 1.13 Standards Accepted Product Category Standard General Requirements IEC 60079-0 Flameproof IEC 60079-1 Pressurised IEC 60079-2 Quartz/Sand Filled IEC 60079-5 Oil Filled IEC 60079-6 Increased Safety IEC 60079-7 Intrinsic Safety IEC 60079-11 Type N IEC 60079-15 Encapsulation IEC 60079-18 Dust (general) IEC 61241-0* Dust (protection td) IEC 61241-1* Dust (protection by enclosure) IEC 61241-1-1* Dust(protection pd) IEC 61241-4* Dust (protection md) IEC 61241-18* Intrinsically safe systems IEC 60079-25* Group II Zone 0 apparatus IEC 60079-26* Fieldbus intrinsically safe (FISCO) IEC 60079-27* Gas detectors (general requirements gas detect) IEC 61779-1* Performance requirements for Group I app IEC 61779-2* Performance requirements for Group I app IEC 61779-3* Performance requirements for Group II app IEC 61779-4* Performance requirements for Group II app IEC 61779-5* Caplights for Group I IEC 62013-1* Trace heating IEC 62086-1* *extension of scope 1.14 National Differences to IEC Standards Group differences are listed in IECEx Bulletin Ed. 2. Page 4 of 15

2. ORGANISATION 2.1 Names, Titles and Experience of the Senior Executives Name Title Experience I. D. Knott Chief Executive Officer 30 years + M. D. Shearman General Manager 6 years D. R. Stubbings Certification Manager 10 years W. Thomas Certification Manager Quality Systems 5 years 2.2 Name, Title and Experience of the Quality Management Representative Name Title Experience B. Howard Quality Manager 15 years 2.3 Name and Title of Nominated Principal Contact Name Title Comments D. R. Stubbings Certification Manager Replacing I.D. Knott 2.4 Names and Titles of Signatories for Certification Name Title Comments D. R. Stubbings Certification Manager --- C. Ellaby Certification Officer --- 2.5 Other Employees in ExCB activity Name Title Responsibility P. Walsh Consultant Engineer Team Leader is, m, n, q B. Allen Senior Certification Engineer D. Holton Senior Certification Engineer A. Deaves Senior Certification Engineer I. Hulse Senior Certification Engineer P.Reeve Consultant Engineer A. Templer Senior Certification Engineer S. Finch Consultant Engineer Team Leader d, e, p, o, class I, IP, fuel pumps D. Hanks Senior Certification Engineer S. Otty Senior Certification Engineer A. Smith Certification Engineer Page 5 of 15

The ExCB may put these engineers in charge as experts for the checking of the completed ExTR s. It is granted by Sira, that the rule concerning independent activities between the ExCB and the ExTL is fulfilled. 2.6 Organisational Structure (Including Changes since Last Assessment) See Annex A for the Organization Chart of the Sira Group and Annex B for the Organization Chart of the Sira Hazardous Area Centre. 3. RESOURCES At the moment thirteen (13) persons are involved in IECEx certification activities in order to secure professional competence in the certification process. One (1) person and additional 10 people under subcontract are involved in the QAR activities. These were reviewed as part of the assessment. 4. COMMITTEES AND APPEAL PROCEDURES Sira appoints a Governing Body according to HAZ Area Centre Quality Manual (HAZ QM) clause 4.1. Customers, according to HAZ QM, clause 8.4, can submit appeals. 5. CERTIFICATION OPERATIONS 5.1 National Approval/Certification Methods Sira is a registered Notified Body under the European ATEX Directive, stated in document Dti URN 04/1805 (ExNB). The NB number is 0518. 5.2 Certification Policy The hazardous area Product Certification policy is described in several chapters of the HAZ QM. 5.3 Staff Work Instructions The hazardous area staff work instructions are described in several chapters of the HAZ QM. 5.4 Application for Certification The certification application process is described in the HAZ Procedure manual, issue 23, section 3. Forms 9118 (for new products) and 9235 (for modifications) are in use for certification applications. Page 6 of 15

6. STATISTICS IECEx Certificates or ExTRs issued during the past 2 years: flameproof d 11 intrinsic safety i 20 increased safety e 8 special s 0 powder filled q 0 encapsulated m 1 type n 0 pressurised p 0 Gas Detectors 0 Apparatus for Dusts 0 700 + TRs have been issued by Sira in accordance with the European ATEX regulation. 7. NATIONAL ACCREDITATION Sira Certification Service holds UKAS Accreditation for the Certification Body No. 011, valid until 30 June 2006. See Annex C for the certificate and Annex D for the Schedule. 8. LIABILITY INSURANCE Indemnity insurance contract was presented, issued by MARSH Ltd. for SIRA LTD and Subsidiary and Associated Companies, South Hill, Chislehurst, Kent, BR7 5EH. This contract is valid until 30 th. 9. QUALITY MANUAL Sira Test & Certification Hazardous Area Centre Quality Manual, issue 16, was presented. Reference to IECEx operation is laid down in Appendix 14 of the SCS Hazardous Area Prod Certi & Assessment Procedures Manual, issue 23. 10. INTERNAL AUDIT AND PERIODIC REVIEW Internal Audits and Management Review is described in HAZ QM clause 6. The computer based PROQUIS-SYSTEM (Quality Management Information System) is used for the control of the processes. The internal audit schedule for 2004 and 2005 was presented for the Chester and the Chislehurst facility. Page 7 of 15

11. COMPLAINTS No-unresolved complaints. Complaints if any - are handled according to HAZ QM clause 8. 12. WITHDRAWAL AND CANCELLATION OF CERTIFICATES Withdrawal and Cancellation of CoC s is handled according to HAZ QM clause 7. 13. REVIEW OF ISSUED CERTIFICATES AND EXTRS The following files were reviewed: # SIR 04 0021, # SIR 04 0022X, # 03 0003U, # SIR 04 0002X and # SIR 04 0005. 14. FINDINGS FROM THE RE-ASSESSMENT 14.1 Mr. I. Knott, responsible for the overall certification activities in Sira was not able to be present. Mr. Mike Shearman deputised. 14.2 Sira Test & Certification Ltd. is presently registered at Chislehurst address. However, the IECEx certification activities are solely operated in Chester. Therefore the address registered in the IECEx scheme is changed to Chester. It is noted, that Sira Test & Certification Ltd. will undergo changes in the organization without losing the competences. However, the re-assessment is performed based on the existing organization. 14.3 Some of the standards listed in chapter 1.7 of this report are not listed in the current UKAS accreditation documents. An asterisk identifies these Standards. Sira seek an extension of their UKAS Scope of Accreditation to cover these, or alternatively, provide a statement in order to allow an annual surveillance visit by IECEx representatives instead of UKAS. 14.4 The certification files listed in Item 13 of this report were checked against IECEx Rules. It was found, due to lack of clarity in the roles of the officers involved, that it was not clear that the ExTR s met the requirements of clause 3.9 of IECEx 02. The process and the organization chart were changed during the re-assessment to better clarify the roles. The assessment team are satisfied that the IECEx requirements are now met. 14.5 It was noted, that Mr. Jim Sheriff, GMI Renfrew, is a member of the Sira Appeal Board. GMI is under subcontract with Sira as a test laboratory for gas instruments. Mr. Sheriff will step back in cases GMI is involved and which may cause a conflict of interest. Page 8 of 15

A record of actions taken to resolve the above issues, together with detailed recommendations has been provided to Sira and the IECEx Secretariat, with the assessment team fully satisfied that all issues have been addressed. 15. RECOMMENDATIONS Based on the re-assessment performed during March 7 th and 8 th, 2005, it is recommended that Sira continue to operate as Certification Body in the IECEx Scheme under the present and the extended scope (chapter 1.13). The condition being that Sira provides UKAS accreditation for the extended scope or a statement to be provided by Sira in order to allow an annual surveillance visit by IECEx representatives instead of UKAS. LIST OF ANNEXES Annex A: Organization Chart of Sira Group Annex B: Organization Chart Sira Hazardous Area Centre Annex C: UKAS Accreditation Certificate for ExCB Annex D: UKAS Accreditation Schedule for ExCB Jim Munro Lead Assessor Heinz Berger Assessor 19 May 2005 Page 9 of 15

Annex A CHART 1 - Organisation of the Sira Group SIRA LTD SIRA LTD SUBSIDUARY COMPANIES SIRA TEST & CERTIFICATION LTD CHISLEHURST SITE SCS HAZARDOUS AREA CENTRE PRODUCT ASSESSMENT TEST LABORATORY PRODUCT CERTIFICATION ADMINISTRATION SUPPORT UNIT QUALITY ASSURANCE Page 10 of 15

Annex B SIRA TEST& CERTIFICATION ORGANISATION CHART (IECEx CERTFICATION) SIRA TEST & CERTIFICATION LTD (Ex TL) SIRA CERTIFICATION SERVICE (EX CB) GENERAL MANAGER Governing Body CHIEF EXECUTIVE CERTIFICATION MANAGER PRODUCTS LABORATORY MANAGER LABORATORY TECHNICIANS (IEC 17025) ASSESSMENT ENGINEERS * TECHNICAL EXPERTS (Signatories) * SUB CONTRACT TEST LABORATORIES CERTIFICATION MANAGER QAR CERTIFICATION OFFICERS Associates Note: The title defined here (*) is the role undertaken to illustrate the independence of the checking function and does not reflect the Job Title of the personnel, which is either Certification Engineer or Consultant Engineer. Personnel may fulfil either function depending on their competence Page 11 of 15 Form 313 Issue 1 (March 2005)

Annex C Page 12 of 15

Annex D Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK SIRA Certification Service Issue No: 43 Issue date: 23 011 Accredited to ISO/IEC Guide 65 to provide product conformity certification South Hill Chislehurst Kent BR7 5EH Contact: Mr I D Knott Tel: +44 (0)20 8467 2636 Fax: +44 (0)20 8468 1841 E-Mail: certification@sira.co.uk Website: www.sira.co.uk Product Standard Electrical apparatus for potentially explosive atmospheres using the following protection concepts: General requirements Oil immersion o Pressurised apparatus p Powder filling q Flameproof enclosures d Increased safety e Intrinsic safety i Type of protection n Encapsulation m Intrinsically safe electrical systems Explosion prevention basic concepts and Methodology Special category requirements Special protection (Exs) EN 50014, IEC 60079-0 EN 50015, IEC 60079-6 EN 50016, IEC 60079-2 EN 50017, IEC 60079-5 EN 50018, IEC 60079-1 EN 50019, IEC 60079-7 EN 50020, IEC 60079-11 EN 50021, IEC 60079-15 EN 50028, IEC 60079-18 EN 50039 EN 1127-1 EN 50284 HSE SFA 3009 Non-electrical equipment for potentially explosive atmospheres EN 13463 Parts 1, 5 and 8 Group 1 Category M1 Equipment EN 50303 Miners cap lamps EN 50033, IEC 62013-1 Electrostatic hand-held spraying equipment EN 50050, BS 6742: Part 1 Electrical apparatus for the detection and measurement of flammable gases: General requirements Performance requirements for Group I apparatus Performance requirements for Group II apparatus EN 50054, IEC 61779-1 EN 50055, EN 50056, IEC 61779-2, IEC 61779-3 EN 50057, EN 50058, IEC 61779-4, IEC 61779-5 Page 13 of 15 Assessment Manager: KB 0011SIRA (Product) Page 1 of 3

Annex D Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK 011 Accredited to ISO/IEC Guide 65 to provide product conformity certification SIRA Certification Service Issue No: 43 Issue date: 23 Product Electrical apparatus for use in the presence of combustible dust Type of protection pd Standard EN 50281-1-1, IEC 61241-1-1 IEC 61241-4 Luminaires EN 60598 Electrical equipment for measurement, control and laboratory use: Safety requirements EN 61010, Part 1 Rotating electrical machines BS 5000: Part 16 Indicating and recording electrical measuring instruments: Safety requirements BS 5458 Mechanical cable glands Metallic, polymeric, or special corrosion resistant glands BS 6121 Parts 1 to 3 Reciprocating internal combustion engines Group I and II engines EN 1834-1, EN 1834-2, EN 1834-3 Industrial Trucks EN 1755 Metering pumps & dispensers to be installed at filling stations and used to dispense liquid fuel BS 7117: Part 1 PAS 022 Electrical resistance trace heating IEC 62086-1, IEEE 515 Flame arrestors BS 7244, EN 12874 Electrical apparatus for the detection of combustible gases in domestic premises BS 7348 Portable apparatus designed to detect and measure combustion flue gas of domestic heating appliances BS 7927 Page 14 of 15 Assessment Manager: KB 0011SIRA (Product) Page 2 of 3

Annex D Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK 011 Accredited to ISO/IEC Guide 65 to provide product conformity certification SIRA Certification Service Issue No: 43 Issue date: 23 Product Standard Environment Agency MCERTS scheme Continuous emission monitors Continuous ambient air quality monitors (excluding open path instruments) Continuous water monitors Performance standards for gaseous emissions, particulates, temperature, pressure and flow rate Performance standards for SO 2, NO x, CO, O 3, PM 10, PM 2.5, Metals, Benzene and PAH s Performance standards for flow, turbidity, ph, total ammonia, chemical oxygen demand, total organic carbon, dissolved oxygen, total phosphorus, nitrate and total oxidized nitrogen, and automatic sampling equipment Functional safety of electrical/electronic/programmable electronic safety-related systems covering process hardware Processes for assuring functional safety of electrical/electronic/programmable electronic safety related systems, covering all overall life cycle phases for systems up to and including SIL3 for use in oil, gas, chemical, petrochemical and pharmaceutical industries. IEC 61508:Parts 1 & 2 IEC 61511:Part 1 IEC 61508-1 Clause 6: Management of Functional Safety, when assessed in compliance with the CASS Guide to Functional Safety Capability Assessment. Certification to technically equivalent standards to those listed above is permitted. END Page 15 of 15 Assessment Manager: KB 0011SIRA (Product) Page 3 of 3