VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

Similar documents
Installation and Maintenance Manual Please retain this manual for future reference.

P4000 Construction Heater

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

Construction Heater. Installation and Maintenance Manual

Installation and Maintenance Manual Please retain this manual for future reference.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

1800(L) Construction Heater

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

Installation and Maintenance Manual Please retain this manual for future reference.

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC- 355DF (Dual Fuel)

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

CYLINDER NOT INCLUDED

1. GENERAL SAFETY RULES

VG1000. Construction Heater. Installation and Maintenance Manual

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

OPERATING INSTRUCTIONS MANUAL FLE-150 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

CYLINDER NOT INCLUDED

KEROSENE FORCED AIR HEATER

OPERATING INSTRUCTIONS MANUAL FLE-150 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

Construction Heater GENERAL HAZARD WARNING

Model Numbers MH-16-TTC / MH-32-TTC / MH-47-TTC

positions, side by side, end to end and Tee configurations. and utility pedestals

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference)

Model Numbers REM-80V-LPC-O / REM-200V-LPC-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS

PROPANE CONSTRUCTION HEATER

OPERATING INSTRUCTIONS AND OWNER S MANUAL

OPERATING INSTRUCTIONS MANUAL FLE-60 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

GENERAL HAZARD WARNING

PROPANE CONSTRUCTION HEATER

User s Manual & Operating Instructions Model Number MH-150NGT-GFA-A

PROPANE CONSTRUCTION CONVECTION HEATER OWNER S MANUAL

User s Manual & Operating Instructions Model Number MH-375T-GFA-A

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Model Numbers PT-16-TTC / PT-32-TTC / PT-47-TTC

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Construction Heater GENERAL HAZARD WARNING

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-1000TR INDIRECT FIRED HEATER TRAILER

User s Manual and Operating Instructions. Model #: HH-70-SS. CONSUMER: Retain this manual for future reference.

Construction Heater GENERAL HAZARD WARNING. Failure to comply with

PROPANE CONSTRUCTION CONVECTION HEATER OWNER S MANUAL VARIABLE 30-80,000 BTU/HR ,000 BTU/HR

OPERATING INSTRUCTIONS AND OWNER S MANUAL

PROPANE FORCED AIR. HEATER operation manual HL060F HL125F

WARNING. PROPANE FORCED AIR HEATER User s Manual & Operating Instructions. Safety Information

User s Manual & Operating Instructions Model Numbers MH-40-GFA / MH-60V-GFA-A / MH-125V-GFA-A / MH-150V-GFA-A

Model #s: MH-40-GFA, MH-60V-GFA, MH-125V-GFA, MH-150V-GFA

DIESEL/PARAFFIN HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

PATRON CLIMAT OIL FIRED CONSTRUCTION HEATERS MODELS 40, 50 AND 130 OWNER S MANUAL. HEATER SIZES 135,000 and 195,000 and 570,000 BTU/Hr

PROPANE CONSTRUCTION HEATERS

PARAFFIN/DIESEL HEATER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400TRLT INDIRECT FIRED HEATER TRAILER

Model Numbers REM-18-PCH-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS. Safety Information

OPERATING INSTRUCTIONS

PT Series Manual WARNING. Detroit Radiant Products Co. Installation Operation Maintenance and Parts. For Your Safety

Click Here To View Item at

OPERATING INSTRUCTIONS FORCED AIR PROPANE CONSTRUCTION HEATERS

Dyna-Glo Delux Natural Gas Radiant Heaters

PROPANE CONSTRUCTION HEATER

USER'S INFORMATION MANUAL

CINCINNATI, OH USA

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

OPERATING INSTRUCTIONS AND OWNERS MANUAL GAS-FIRED INFRA-RED TANK TOP HEATER

PROPANE CONSTRUCTION HEATER OWNER S MANUAL

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

TMB Baking TSV Gas Oven TAG Series. Contractor s Utility Requirements

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

CBO-750 HYBRID-R OVEN Instructions Manual

OWNERS MANUAL INDIRECT OIL-FIRED HEATERS Models K150-FAI, K275-FAI TABLE OF CONTENTS HEATER SPECIFICATIONS... 2

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

Dayton Propane Gas Convection Construction Heaters

User s Manual and Operating Instructions

Bosch 80% AFUE Gas Furnace BGS80 Model

Dayton Propane Construction Heater

OPERATING INSTRUCTIONS AND OWNER S MANUAL

KEROSENE PORTABLE. HEATER operation manual HK400FW

Propane Construction Heater

OPERATING INSTRUCTIONS AND OWNER S MANUAL

User s Manual & Operating Instructions

User s Manual and Operating Instructions. Model: HH-18-PCH. Carbon Monoxide Hazard This heater produces carbon monoxide, which has no odor.

Using it in an enclosed space can kill you.

Serial #4277 and Beyond

INSTALLATION AND OPERATION INSTRUCTIONS

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

PAULIN PRODUCTS INDOOR HEATER

Model Numbers MHP-135-KFA / MHP-190-KFA / MHP-215-KFA

MODELS SPC-54PHW, SPC-54PHB, SPC-54PHT and spc-54phs

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Transcription:

342 N. Co. Rd. 400 East Valparaiso, IN 46383 888-432-8924 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. VF/VG700 Jumbo Construction Heater C US Revision 1-09 CAUTION: Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored.

CONSTRUCTION HEATER GENERAL HAZARD WARNING: Failure to comply with the precautions and instructions provided with this heater, can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical shock. Only persons who can understand and follow the instructions should use or service this heater. If you need assistance or heater information such as an instruction manual, labels, etc., contact your local Heat Wagon dealer or the manufacturer. W A R N I N G Fire, burn, inhalation, and explosion hazard. Keep solid combustibles, such as building materials, paper or cardboard, a safe distance away from the heater as recommended by the instructions. Never use the heater in spaces which do or may contain volatile or airborne combustibles, or products such as gasoline, solvents, paint thinner, dust particles or unknown chemicals. Not for home or recreational vehicle use! WARRANTY All new Heat Wagon and Sure Flame heaters and fans are guaranteed against defective materials and workmanship for one (1) year from invoice date. Warranty repairs may be made only by an authorized, trained and certified Heat Wagon dealer. Warranty repairs by other entities will not be considered. Warranty claims must include model number and serial number. LIMITATIONS Warrant claims for service parts (wear parts) such as spark plugs, igniters, flame rods will not be allowed. Diagnostic parts such as voltage meters and pressure gauges are not warrantable. Evidence of improper fuel usage, fuel pressures outside of manufacturer s specification, poor fuel quality, and improper electric power, misapplication or evidence of abuse may be cause for rejection of warranty claims. Travel time, mileage and shipping charges will not be allowed. Minor adjustments of heaters are dealers responsibility. Defective parts must be tagged and held for possible return to the factory for 60 days from date of repair. The factory will provide a return goods authorization, (RGA) for defective parts to be returned. No warranty will be allowed for parts not purchased from Heat Wagon. 1 342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 888-432-8924 Fax 800-255-7985 www.heatwagon.com

2

3

NOTE: Manifold Pressure - Natural Gas 2.8 W.C. 3.7 Orifice Vapor Propane 2.8 W.C. 2.0 Orifice 4

5

6

7

8

9

10

11

EXHAUST FLUE PIPE GUIDELINES CAPACITY OF TYPE B DOUBLE-WALL VENTS SERVING A SINGLE DRAFT HOOD-HEATER x 1000 BTU'S FOR INDOOR APPLICATIONS TOTAL VENT HEIGHT(H)F FEET LATERAL LENGTH (L) FEET VENT DIAMETER (D) INCHES 8 10 12 14 6 0 370 570 850 1170 2 285 455 650 890 6 273 435 630 870 12 255 406 610 840 8 0 415 660 970 1320 2 322 515 745 1020 8 303 490 720 1000 16 281 458 685 950 10 0 450 720 1060 1450 2 355 560 850 1130 10 330 525 795 1080 20 300 486 735 1030 15 0 525 840 1240 1720 2 414 675 985 1350 15 373 610 905 1250 30 328 553 845 1180 20 0 575 930 1350 1900 2 470 755 1100 1520 10 443 710 1045 1460 20 410 665 990 1390 30 380 626 945 1270 30 0 650 1060 1550 2170 2 535 865 1310 1800 20 473 784 1185 1650 40 415 705 1075 1520 12

REFERENCE CHARTS VAPOR PROPANE QUICK REFERENCE HOSE CHART Hose BTU Length 1 Million in Feet 1/2PSI 10PSI 10 1-1/4 3/4 25 1-1/4 3/4 35 1-1/4 3/4 50-3/4 75-3/4 100-3/4 125-3/4 150-3/4 175-3/4 200-3/4 225-3/4 NATURAL GAS QUICK REFERENCE HOSE CHART Hose BTU Length 1 Million in Feet <1PSI 1PSI 2PSI 5PSI 10 1-1/2 1-1/4 3/4 3/4 25 2 1-1/4 3/4 3/4 35 2 1-1/4 3/4 3/4 50 2 1-1/4 1-1/4 3/4 75 2 1-1/4 1-1/4 3/4 100 2 1-1/4 1-1/4 3/4 125 2-1/2 1-1/2 1-1/4 3/4 150 2-1/2 1-1/2 1-1/4 3/4 175 2-1/2 1-1/2 1-1/4 3/4 200 2-1/2 1-1/2 1-1/4 3/4 225 2-1/2 1-1/2 1-1/4 3/4 13

14

CLEAN DRY HEAT! Model VG700 Indirect Fired Gas Heater Shown with optional duct adaptor AR-702 (1x24 ) NEW FOR 2008 Versatility of dual fuel - natural gas & propane Reliable Riello burner Remote thermostat Wheels for easy portability Long lasting stainless steel combustion chamber High performance axial fan Ductable to 200 ft. 100% dry heat, clean of combustion by-products Set It And Forget It! S P E C I F I C AT I O N S Input 700,000 BTU/Hr Fuel Vapor Propane/Natural Gas Gas Consumption 7.7 GPH Propane/700 CFH NG Gas Connection 1 FNPT Electrical 240 Volts 15 amp circuit Fan 7,420 CFM 2 W.C. SP Thermostat Standard On/Off Temp Rise 120 F @ 0ºF Ambient Rated Efficiency 85% Dimensions 79 L x 29 W x 51 H Duct Size 24 (up to 200 straight) Approx. Weight 550 lbs. Split Duct Adaptor (2x20 ) (optional) AR712 Chimney Support Kit (optional) AR-714 Stacking and Lifting Kit (optional) 342 N. Co. Rd. 400 E. Valparaiso, IN 46383 219-464-8818 219-462-7985 www.heatwagon.com