Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Similar documents
O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Connecting cable. Installation instructions (2018/04) US

PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT

Intelligent cascading kit

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

User manual. Logano GC 124 II. Gas boiler

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Installation & User s Instructions

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

/2010 US/CA

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

User Manual for model

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

O CRC100. Comfort Room Controller (2015/01) en

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

Installation and servicing instructions

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Operating instructions

Operating instructions

Quickheat 30 weather compensated boiler control

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Programmable Towel Radiator Manual

- Data Brochure Steam Control 279

User Manual for model

USER'S INFORMATION MANUAL

NR-20DU. Keep this manual near this remote controller for future reference whenever maintenance or service is required.

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Thermo 230 / 231 / 300 / 301 / Troubleshooting

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USER'S INFORMATION MANUAL

Bosch Split-Type Ductless Air Conditioner / Heat Pump

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Operating instructions

Wired Controller XK60

USER'S INFORMATION MANUAL

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01

Operating instructions

USER'S INFORMATION MANUAL

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Air to Water Heat Pump -Mono Control Unit. user manual. imagine the possibilities

Operating instructions

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

TM-802 Formaldehyde Meter User s Manual

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

Whats in the box. NS1002-E Installation Guide Rev 1.0

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

prestige Control Application Supplement WARNING

DOMESTIC HOT WATER Follow operational sequence

ELECTRIC BOILERS FOR CENTRAL HEATING

CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

A-MIP 210 Installation and user guide

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat.

User reference guide. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

BOSCH CONDENS 5000W ZSB18-2A

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

Modulating clock thermostat

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

ir-range 8G /03.15 Changes reserved.

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

User instructions DHP-AT

HI-LINE RC & HI-LINE RC Heater/Cooler Models: 7-4, 10-6, 15-10, Installation, Operating, Maintenance and After Sales Manual.

Installation and Operating Manual

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Operating instructions

prestige Control Application Supplement - ACVMax

Settings and Maintenance of the CombinAir

GB162 Concentric Horizontal Vent Kit

Analog Room Pressure Monitor RPC Series

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK

Brivis Touch Controller. Installer Manual

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor

Installation, Start-Up, and Operating Instructions

USER'S INFORMATION MANUAL

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

Installation and user manual

prestige Indirect Water Heater (IDWH) Sensor Application Supplement WARNING

SLIM-LINE RC. Installation, Operating, Maintenance and After Sales Manual. Please leave this manual with the end user. Part Number: Issue 3

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

T-32-TS Touchscreen Thermostat. Installation Manual

Transcription:

8 733 201 137-00.1O Wall Hung Boiler Room Thermostat OR30 OT Thermostat Operating Instruction 6 720 812 418 (2014/07) en

2 Contents Contents 1 Symbols and safety precautions.................................. 3 1.1 Key to symbols........................................... 3 1.2 Safety instructions........................................ 4 2 Delivery scope................................................. 5 3 Product instruction............................................. 6 3.1 Proper use............................................... 6 3.2 Technical parameters...................................... 6 3.3 Accessories.............................................. 6 3.4 Main functions and features................................. 7 3.5 Cleaning................................................. 7 4 Product description............................................. 8 5 Installation.................................................... 9 5.1 Installation instructions.................................... 9 5.2 Installation of room thermostat.............................. 9 5.3 Installation steps......................................... 10 6 Operation instructions......................................... 14 6.1 Temperature calibration................................... 14 7 Applicable model.............................................. 15 OR30 OT Thermostat 6 720 812 418(2014/07)

Symbols and safety precautions 3 1 Symbols and safety precautions 1.1 Key to symbols Warnings Warnings in this document are identified by a warning triangle printed against a grey background. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken. The following keywords are defined and can be used in this document: NOTICE indicates a situation that could result in damage to property or equipment. CAUTION indicates a situation that could result in minor to medium injury. WARNING indicates a situation that could result in severe injury or death. DANGER indicates a situation that will result in severe injury or death. Important information This symbol indicates important information where there is no risk to people or property. Additional symbols Symbol Explanation Step in an action sequence Cross-reference to another part of the document List entry List entry (second level) Table 1 6 720 812 418(2014/07) OR30 OT Thermostat

4 Symbols and safety precautions 1.2 Safety instructions General safety instructions Follow the manual to ensure complete functionality. Install and use heaters and other accessories according to the manual. Accessories only can be installed by authorized installer. The accessories must not be connected to power supply of 220~240V. Before installing the accessories: Interrupt power supply of heaters and other members of bus (220~240V AC). Please inform the working way of the accessories, and guide customers to operate. Heater is switched on when freezing danger occurs, and comply with anti-freezing tips. Damage caused by operational errors Operational errors may cause personal injury and/or property damage. Ensure that children should not operate and/or play with the equipment under unattended circumstances. Ensure that the equipment only can be touched by personnel who can operate the equipment correctly. OR30 OT Thermostat 6 720 812 418(2014/07)

Delivery scope 5 2 Delivery scope 1 8 733 201 137-01.2O 2 3 Fig.. 1 [1] OT controller [2] Installation package (screws...) [3] Manual instruction 6 720 812 418(2014/07) OR30 OT Thermostat

6 Product instruction 3 Product instruction OR30 room thermostat has the advantages of easy operation and practicality. 3.1 Proper use Please carefully read this manual before using, and operate according to requirements specified in the manual. Error conditions please refer to error code introduction of wall hung boiler. 3.2 Technical parameters Voltage 3V± 10% Temperature range 5~30 C Measure precision ± 1 C Dimensions 86 86 28mm Ambient temperature -5 C~40 C Load current 0.5A~125VAC 2A~30VDC Material & Color Ivory ABS Table 2 3.3 Accessories Manual instruction Installation package Screws*2 Anchors*2 OR30 OT Thermostat 6 720 812 418(2014/07)

3.4 Main functions and features Set temperature by knob Display current temperature Boiler working condition Memory function in case of power-down Fault display function Reset function for boiler fault Temperature correction Check the CH and DHW water temperature Set the parameter of CH and DHW water Control the flame so as to make the room temperature comfortable Product instruction 7 3.5 Cleaning Use wet cleaning cloth to wipe the housing of controller. Must not use irritant or corrosive detergent. 6 720 812 418(2014/07) OR30 OT Thermostat

8 Product description 4 Product description 9 8 7 6 1 2 3 5 4 8733201137-02.2O Fig. 2 [1] Operation condition [2] Room temperature icon [3] Up \Exit \Reset [4] Down\ menu [5] Temperature knob [6] Current room temperature [7] DHW (Domestic heating water) [8] CH (heating water) [9] Anti-freezing OR30 OT Thermostat 6 720 812 418(2014/07)

Installation 9 5 Installation 5.1 Installation instructions Isolate the appliance from the electrical supply. Avoid installing the thermostat close to fridge, radiator, kitchen, computer, window, doorway or other over-cooling, over-heating and temperature changed frequently areas. The best position to install the thermostat is a dry place which can precisely reflect room temperature, and has low interference. Ambient temperature: -5 C~40 C Relative humidity: Max RH 85% (23 C) Altitude: Less than 2000 Meter 5.2 Installation of room thermostat The standard mounting holes are at the back of thermostat, and user can install the thermostat on the wall with them. Open the thermostat and install the thermostat according to the letters given by the follow picture. Wall-hung boiler 6720812418-01.1O Fig. 3 6 720 812 418(2014/07) OR30 OT Thermostat

10 Installation 5.3 Installation steps Finger-tighten the middle part of three edges of back cover, as shown in the figure, to make the three edges recessed, and then remove back cover( see Fig. 4). 8733201137-04.2O Fig. 4 OR30 OT Thermostat 6 720 812 418(2014/07)

Installation 11 Drill two installing holes on the wall, and push swell plastic button in holes. Use screws to fix back cover onto wall surface,( see as Fig. 5) (Distance between two holes is 60mm, please try to make uniform height). Wall space 6720812418-02.1O Fig. 5 6 720 812 418(2014/07) OR30 OT Thermostat

12 Installation Use a screwdriver to connect OT cable to product connector base, as shown in Fig. 6 (Regardless of cable positive and negative electrodes). Wall space 6720812418-03.1O Fig. 6 OR30 OT Thermostat 6 720 812 418(2014/07)

6720812418-04.1O Installation 13 Fix the product on the back cover, as shown in Fig. 7. Wall space Fig. 7 6 720 812 418(2014/07) OR30 OT Thermostat

14 Operation instructions 6 Operation instructions OR30 room thermostat has the advantages of easy operation and practicality. The function of it is operated by two key and a knob. Fault reset: Press UP keys to reset if the fault code occurs. Check CH/ DHW temperature: Press Down key to check the CH/ DHW temperature, and then press UP key to exit. Set target room temperature: Increase or decrease the room temperature by rotating knob. Set the target temperature of DHW: Press DOWN key twice to check DHW temperature, then press DOWN and UP simultaneously to set the target temperature of DHW. Adjust the target point by DOWN and UP key. Press DOWN and UP once simultaneously to exit. Temperature calibration: Press DOWN and UP simultaneously for 5s to start temperature calibration. LCD shows battery icon, and calibrates the temperature by DOWN and UP key. Press DOWN and UP simultaneously once to exit. Default reset: Press UP key for 5s until LOD blinks.press any key to exit. The temperature displayed on thermostat is different from thermograph.the test methods of thermograph and thermostat are different. In general conditions, thermostat s temperature sensor is more precise than thermograph. Due to the difference of regions and environments thermostat has a slight deviation. If this deviation is large (>5 C), you can use temperature calibration to adjust (See part 6.1). 6.1 Temperature calibration Due to the regions and environments thermostat has a slight deviation. user can adjust the temperature through temperature calibration. Press up(p8) and down(p9) key together to enter temperature correction and then the battery icon will flash up on the LCD. Adjust the value by up(p8) and down (P9) key. If the temperature difference is not very obvious, this function is not recommended. OR30 OT Thermostat 6 720 812 418(2014/07)

Applicable model 15 There is 2 C inaccuracy in household thermometer. 7 Applicable model Boiler model Model No. Serials Eurosmart MINI New Eurostar Table 3 L1P18 WBN6000-16C 7716482002 N1P17 WBN6000-15S 7716482003 L1P20-WBN6000-18CRN S5500 0T1010044700023338 N1P20-WBN6000-18HRN S5500 0T1010044700023332 L1P27-WBN6000-24CRN S5500 0T1010044700023339 N1P27-WBN6000-24HRN S5500 0T1010044700023333 L1P31-WBN6000-28CRN S5500 0T1010044700023340 N1P31-WBN6000-28HRN S5500 0T1010044700023334 6 720 812 418(2014/07) OR30 OT Thermostat