Clean Bench Animal Transfer Stations

Similar documents
ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

B. Design meeting requirements of the particular class and type of cabinet as follows:

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Innovation in air purification unmatched air quality

LABORATORY CABINETS 103

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

DOWNDRAFT BENCH SERIES

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

Cleanshield HEPA 550 Owner's Manual

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

OPERATOR S MANUAL. Horizontal Laminar Flow Clean Bench

M Series Fan Filter Units

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

L a b o r a t o r y E q u i p m e n t C a t a l o g

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

5.0 Installation Instructions

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Precision Containment for All Applications

Biological Safety Cabinets or Fume Hoods Which one to use?

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

OPERATOR S MANUAL. SterilSHIELD Product Protection Only Isolator MODEL SS500

CLEAN AIR SYSTEM.

Gelaire BH-EN and UltraSafe cabinets

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Thermo Scientific 1300 Series A2

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

Microbiological Safety Cabinets

IVF/ART Series Laminar Flow Cabinets

LAMINAR FLOW FOR ALL YOUR NEEDS

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

XPert Balance and Bulk Powder Enclosures

Down flow clean air cabinet Star of the Universe. Fortuna

V SERIES. versatile/portable cartridge dust collectors. Model VP. Model VF. Model VB

Bedding Disposal Workstations The Portable Safety Solution for Animal Research Laboratories. Viva Bedding Disposal Workstation, Model VBD-4A_.

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

VWR symphony CO 2 INCUBATORS

INCREASE YOUR LAB EFFICIENCY

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

V SERIES. versatile/portable cartridge dust collectors. Model VP. Model VF. Model VB

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Zeus Extreme Owner's Manual

F112A,C; F113A,C Portable Air Cleaners

V SERIES. versatile/portable cartridge dust collectors. Model VP. Model VF. Model VB

FOOD WARMING/MERCHANDISING CABINET MODEL

User s Manual and Operating Instructions

INCREASE YOUR LAB EFFICIENCY

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations


M-11 Series. Installation and Service Manual

INCREASE YOUR LAB EFFICIENCY

CIRCULAIRE LAMINAR AIR FLOW

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Controlled Environment Equipment Solutions for the Lab

BIOLOGICAL SAFETY CABINET

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

BioSafety Cabinet- Class 100

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Safe Operating Procedure (Revised 2/10)

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

Air Purifier. Purificador de aire. Use and Care Guide Manual de uso y cuidado. Model / Modelo : HAP52010E

How to Grow Your Business Using Abatement HEPA AIRE Portable Power Vacuums

AIR SHOWERS CAP701 SERIES

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

INCREASE YOUR LAB EFFICIENCY

Phoenix AirMAX - Radial Air Mover

Replacement Filter Information

Class II Biosafety Cabinets

User s Manual and Operating Instructions

Standard Operating Procedure M.I.C.E.

HALCO PRODUCTS COMPANY

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

User Guide. BlueairMedical FEATURING HEPASILENTª TECHNOLOGY

WELD STRONG BREATHE FREE

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Transcription:

Animal Research Products Clean Bench Animal Transfer Stations Welcome to a comfortable clean bench. Underwriter Laboratories Listed

Animal Research Clean Benches Comfortable, easily accessible designs make these clean benches ideal for the animal laboratory environment. Designed exclusively for live animal cell culture applications within the animal research laboratory, our clean benches are backed by years of extensive research, customer feedback, and product testing to ensure that you experience optimum productivity, safety, and versatility. AniGARD e3 AniGARD VF EdgeGARD Versatile clean bench animal transfer stations designed with you in mind Spacious, easily accessible work areas accommodate a variety of cage sizes and activities. Ergonomic design with efficient lighting increases user comfort and visibility. Designed for easy movement and maneuverability throughout the laboratory. Offers down to ISO Class 4 (Class 10) protection by delivering HEPA-filtered, particulate-free air. Blower/motor system extends filter life, minimizing filter replacements and life-cycle costs.

AniGARD e3 Animal Transfer Station Vertical-Flow Partially-Recirculating Clean Bench Multi-Sided 4' and 5' Cabinets Energy Efficient Engineered The AniGARD e3 combines improved containment and enhanced ergonomics with lower energy requirements to provide you with unrivaled performance and protection. This durable, easily maneuverable animal transfer station features an ergonomically engineered, adjustable work surface and slanted viewscreen for increased worker comfort. Permitting operator access on three sides, the AniGARD e3 ATS is designed to provide animal protection and particulate control in the laboratory while maximizing productivity and flexibility. The AniGARD e3 provides ISO Class 4 (Class 10) air cleanliness and was designed to reduce user exposure to allergens. Designed to Increase Your Productivity Comfortable user experience Slanted viewscreen on three sides of cabinet provides a direct line-of-sight panoramic view of the workspace. Well-lit workspace significantly reduces eyestrain. Low noise level improves operator comfort and reduces effect of ambient noise on animals. HEPA-filtered air throughout the work surface provides ISO Class 4 (Class 10) protection, reducing operator s exposure to allergens. 12" knee space opening provides seated access for small procedures. Ease of use and versatility Three-sided work area permits access by multiple operators, facilitating team-based projects. 14" high access openings and a flat, spacious work surface allow cages in a variety of sizes to be pulled in and out quickly. Hinged viewscreen opens to 21¾" for moving large items in and out of the workspace prior to working in the cabinet, allowing greater visibility and access to work area. Electric hydraulic lift motor adjusts, allowing a work surface height of 32 ½ to 44 (with 5" casters) to maximize individual comfort. Wide tread stainless steel casters for easy maneuverability and movement throughout the lab. 25' retractable power cord provides greater range of use without unplugging. Optional pull bar provides ultimate portability. Easily Adjusts to Meet Your Needs Energy Efficient Engineered The AniGARD e3 utilizes StediFLOW, a self-adjusting motor technology that requires less energy, extends filter life, and reduces heat output to the lab without sacrificing performance. PAGE 3

Superior Performance in Cleanliness, Protection, and Containment Air Cleanliness ISO Class 4 at 0.5 micron (Class 10). Product Protection Meets NSF 49 requirements (for biosafety cabinets). Allergen Control Approaches NSF 49 requirements (for biosafety cabinets). Minimizes cage-to-cage cross contamination. Optional ULPA filtration for increased product and personnel protection. Baker Builds It Better Manufactured for durability Stainless steel side wall resistant to sterilants and clydox to greatly reduce potential for corrosion. Reduced Exposure to Allergens Corner rubber bumpers protect the unit and the lab during minor collisions. ¼" clear acrylic, scratch-resistant viewscreen. Durable for Maximum Portability Leg stiffeners and large stainless steel casters provide a solid base for the unit. Designed for easy cleaning and maintenance Moveable, two-piece work surface for easy access to spill tray and pre-filter. Welded, full perimeter drain pan under the work surface with 1" drain valve catches liquid or spills and protects electrical components. HEPA filters are easily accessed at the top of the cabinet. Easily removable pre-filter is located below the work surface. Designed for easy serviceability including access panels for all electrical components. PAGE 4 Blower/motor system extends filter life, minimizing filter replacements and lifecycle costs. Direct Access for Simple Cleaning

Exclusive Momentum Air Curtain Ensures Safety The AniGARD e3 employs a unique high-velocity momentum air curtain to help ensure product protection and offers personnel protection without restricting access. Diffuser This unique airflow design generates a strong air barrier along the perimeter of the work surface, working to prevent room particulates from entering the work area. A stainless steel diffuser strategically positioned just below the supply filter directs filtered air down the inside of the viewscreen, creating faster airflow compared to the center of the work area. Access Opening On 3 Sides Perforations along the perimeter of the work surface under negative pressure assist in capturing particulates that are entrained by the momentum air curtain. Faster airflow at viewscreen increases protection without restricting access. Airflow Design Ensures Maximum Protection The AniGARD e3 is designed to protect animals from particulate exposure and cross-contamination and reduce users' exposure to allergens by providing HEPA filtration in a partially recirculating air system. Its recirculating air design eliminates air discharge near the floor that could kick up dust and dander from the floor and into the environment. How the AniGARD e3 Works: Exhaust HEPA Filter Supply HEPA Filter HEPA-filtered air is delivered to the work area in a vertical downward flow. The air passes through a pre-filter located under the work surface, where large particulates are captured. A blower forces air through a vertical duct and into the top of the cabinet. Pre-Filter Half of the air passes through the HEPA supply filter and enters the workspace, and half of the air passes through the HEPA exhaust filter and is released to the laboratory. HEPA-Filtered Air Contaminated Air Room Air A viewscreen prevents the operator s head from entering the clean air stream. PAGE 5

General Specifications Performance Vertical laminar flow recirculating clean air bench with no discharge near the floor. HEPA filters with 99.99% minimum efficiency in capturing 0.3 micrometer particles. Provides ISO Class 4 at 0.5 micron (Class 10) for air cleanliness. Meets NSF 49 requirements for product protection, and approaches NSF 49 requirements for personnel protection. Minimizes cage-to-cage cross contamination. Emits low noise level of no more than 59 dba (AG403) and 62 dba (AG503), when measured according to NSF method. High-velocity momentum air curtain design increases protection. Uses a variable frequency drive (VFD) and three-phase motor/ blower systems (SteadiFLOW ) that is capable of maintaining a constant air volume as filter resistance increases. Construction Three-sided cabinet with large access opening of 14 high. Hinged front and rear side viewscreen opens to 21¾". Carbon steel construction with powder coated exterior finish. 16-gauge stainless steel work surface, divided into two sections for easy removal. Welded, full perimeter drain pan under the work surface with 1 drain valve to catch liquids or spills. Easily accessible exhaust and supply HEPA filters located at the top of the cabinet. 25 retractable power cord that plugs into standard 15 Amp outlet. Electric hydraulic lift system allows the work surface height to be adjusted continuously from 32 ½ to 44 with 5" casters and from 36 to 47 ½ with 6" casters. Single motor blower for intake air and recirculating air. Washable, autoclavable and reusable Scottfoam prefilter located beneath work surface. Hinged viewscreen slanted at a 4 angle and fixed viewscreen slanted at a 10 angle for user comfort. Separate power switch for light. Conveniently located minihelic gauge monitors cabinet operation. Comes standard with wide tread casters, 5" diameter with brakes. Electrical Electronic ballast for fluorescent lighting above front and rear access openings. Listed by Underwriters Laboratory (UL) for electrical, fire, and personnel safety. Optional Accessories Pull Bar (on open or closed end) ULPA Filters Carbon Filter (over exhaust) 6" Casters with Brakes Mouse Corral Folding Table Light Sensor - automatically turns off the unit's lights when room lights are turned off. Viewscreen Magnifier 100 V Model (not UL listed) 220 V Model 4' and 5' (shown above) nominal models available. PAGE 6

Technical Specifications Dimensions: AG403 with 5" casters 58¼" 8" 48" 32½" 30" 10 Slope On 3 Sides Viewscreen Latch Access to Exhaust and Supply HEPA Filters 87 5 8 " Full Up 76⅛" Full Down 14" Opening Hydraulic Lift Control 12" (d) x 28" (w) Knee Space Drain Valve 32½" - 44" Work Surface Height 6½" 25' Retractable Power Cord 5" Diameter Swivel Casters With Brakes Performance Data MODEL NUMBER AG403 AG503 Size 4 5 Exterior Dimensions (w x d x h [min to max]) 58 ¼ x 32 ½ x [76 1 /8-87 5 8 ] 70 ¼ x 32 ½ x [76 1 /8-87 5 8 ] Interior Dimensions (w x d x h) 48 x 30 x 22 ¾ 60 x 30 x 22 ¾ Work Surface Height [min to max] 32 ½ - 44 32 ½ - 44 Usable Workspace (w x d) 42 5 8 x 21 13 16 54 5 8 x 21 13 16 Weight 535 lbs. 585 lbs. Shipping Weight 655 lbs. 720 lbs Access Opening (working position) 14 14 Access Opening (loading/cleaning position) 21¾ 21¾ Operating Amperage 3.7 Amps 4.7 Amps Power Consumption 426 Watts 552 Watts Heat Generation 1,454 BTU/hr 1,85 BTU/hr Electrical Requirements 115 V AC, 15 Amps, 60 Hz 115 V AC, 5 Amps, 60 Hz Noise - NSF Method 59 dba 62 dba Noise - EN Method 57 dba 60 dba Lighting - Minimum average at work surface 100 foot candles 100 foot candles Note: Data for cabinet with 5 casters PAGE 7

AniGARD VF Animal Transfer Station Vertical-Flow Recirculating Clean Bench With Optional Mobile Stand Single-Sided 4', 5' and 6' Models The AniGARD VF Animal Transfer Station is a single-sided, vertical-flow clean bench with spacious access for cage changing and protocols where both animal protection and particulate control are required. This ergonomically engineered cabinet features an optional adjustable work surface and slanted view screen for increased worker comfort. Increased Lab Productivity 14" high access opening accommodates a variety of cage sizes, and offers a wide work area for multiple users. Flat, spacious work surface allows cages to be pulled in and out quickly. Hinged viewscreen opens to 30 3 8" allowing access to work area. Ease of Use and Versatility When configured with mobile stand, casters and pull bars, easy to move and maneuver. At the lowest adjustment, the unit fits through standard doorways and down laboratory aisles. Optional electric/hydraulic lift system positions the work surface elevation at levels from 22" to 40 1 2". Comfortable User Experience Slanted 10 viewscreen for operator comfort and direct line-of-sight viewing. Well-lighted workspace reduces eyestrain. Low noise level improves operator comfort and reduces effect of ambient noise on animals. Provides ISO Class 5 (Class 100) protection by delivering HEPA-filtered air to the work surface. Baker Builds It Better All clean benches are subjected to rigorous testing prior to shipping. Primary HEPA supply filter is removed through the front plenum area. Designed for easy serviceability, including access panels for all electrical components. Rear forklift slots facilitate installation. (Available on lift stand option.) Pre-filter below work surface helps capture large particles, prolonging HEPA filter life. Unique high-velocity momentum air curtain to help ensure product protection without restricting access. PAGE 8

Technical Specifications Performance Data MODEL NUMBER AG4-VF AG-5-VF AG-6-VF Size 4 5' 6' Exterior Dimensions w/ Stationary Stand (w x d x h [min to max]) 53 1 2 x 32 x [89 1 16-97 9 16 ] 65 1 2 x 32 x [89 1 16-97 9 16 ] 77 1 2 x 32 x [89 1 16-97 9 16 ] Exterior Dimensions w/ Mobile Stand (w x d x h [min to max]) 64 x 35 9 16 x [80 15 16-97 9 16 ] 76 x 35 9 16 x [80 15 16-97 9 16 ] 88 x 35 9 16 x [80 15 16-97 9 16 ] Interior Dimensions (w x d x h) 46 x 23 x 31¾ 58 x 23 x 31¾ 70 x 23 x 31¾ Shipping Weight 785 lbs. 879 lbs. 974 lbs. Access Opening (working position) 14 14" 14" Access Opening (loading/cleaning position) 30 3 8 30 3 8 30 3 8 Electrical Requirements 115 V, AC 115 V, AC 115 V, AC Amps / Breaker 16 / 20 16 / 20 16 / 20 General Specifications Interior workspace made from 16-gauge stainless steel. Better than ISO Class 5 (Class 100) air cleanliness in the workspace. Carbon steel construction with powder coated exterior finish. HEPA filters with 99.99% minimum efficiency in capturing 0.3 micrometer particles. Optional Accessories Plumbing: One petcock on right-hand side (option for more); petcock connection choices located on bottom, back and top (channel stand) and on side only for lift stand Stationary stand Electric/hydraulic lift system Edstrom watering unit with gooseneck sprayer Separate switches for blower and light; if blower is not on, light switch will not work. Large, easy-to-read magnehelic gauge confirms cabinet operation. Washable pre-filter extends HEPA filter life. Optional wide tread, stainless steel casters, 5" diameter x 1 1 4", with brakes. One duplex on left-hand side (option for one on right-hand side). PAGE 9

EdgeGARD Animal Transfer Station Laminar-Flow Clean Bench Standard with Casters 3', 4', 5', 6' and 8' Models The EdgeGARD Animal Transfer Station is a horizontal laminar-flow clean bench that provides HEPA-filtered airflow across the work area and a particulate-free work surface. This cabinet is ideal for a range of laboratory animal research applications where clean air and product protection are essential. Product protection high-velocity return air slots along the front edge and side walls of the work area provide protection from contaminated backwash. Comfortable all models feature non-glare stainless steel work surfaces and sidewalls. Efficient the HEPA supply filter is 99.99% efficient for 0.3 micrometer particulates. Provides ISO Class 5 (Class 100) protection by delivering HEPA-filtered air to the work surface. Cost effective voltage-compensated blower/motor maintains performance, extends filter life. Mobility pull bars and casters ensure easy maneuverability and convenience. PAGE 10

Technical Specifications Performance Data MODEL NUMBER EG3252-ATS EG4252-ATS EG-4320-ATS EG6320-ATS Size 3 4' 4' 6' Exterior Dimensions (w x d x h) Interior Dimensions (w x d x h) 43 1 4 x 34 x 69 5 8 55 1 4 x 34 x 69 5 8 55 1 4 x 34 x 75 5 8 79 1 4 x 34 x 75 5 8 34 1 2 x 22 x 28 1 8 46 1 2 x 22 x 28 1 8 46 1 2 x 22 x 34 1 8 70 1 2 x 22 x 34 1 8 Net Weight 360 lbs 440 lbs 560 lbs 850 lbs Shipping Weight 500 lbs 600 lbs 700 lbs 1100 lbs Electrical 115 V, AC 115 V, AC 115 V, AC 115 V, AC Amps / Breaker 12/15 16/20 16/50 24/30 MODEL NUMBER EG5252-ATS EG6252-ATS EG-8252-ATS Size 5 6' 8' Exterior Dimensions (w x d x h) Interior Dimensions (w x d x h) 64 3 4 x 34 x 75 5 8 79 1 4 x 34 x 75 5 8 103 1 4 x 34 x 75 5 8 58 1 2 x 22 x 28 1 8 70 1 2 x 22 x 28 1 8 94 1 2 x 22 x 28 1 8 Net Weight 700 lbs 840 lbs 1000 lbs Shipping Weight 850 lbs 1000 lbs 1250 lbs Electrical 115 V, AC 115 V, AC 115 V, AC Amps / Breaker 16/20 24/30 24/30 General Specifications HEPA supply/exhaust filters with 99.99% minimum efficiency in capturing 0.3 micrometer particulates. Provides ISO Class 5 (Class 100) protection by delivering HEPA-filtered air to the work surface. Removable screen protects HEPA filter. Washable pre-filter extends HEPA filter life. Hinged panel for easy cleaning. Non-glare stainless steel work surface. StediVOLT motor speed controller adjusts to maintain proper airflow. Independent GFCI outlet for safety. Casters: 5" diameter x 1 1 2" wide tread. Two pull bars. Optional Accessories Isolated motor blower Magnehelic gauge PAGE 11

Caution A clean bench is not designed to protect personnel or the environment from potentially harmful agents. The adequacy of this product for the user s personal safety, as with any clean bench, should be determined by an industrial hygienist or safety officer. Site preparation information, architectural drawings, detailed dimensions and purchase specifications are available. Warranty The Baker Company, Inc., expressly represents and warrants all goods (a) to be as specified (and described) in The Baker Company catalogs and literature, and (b) to be free under normal use, service and testing (all as described in The Baker Company catalogs and literature) from defects in material and workmanship for a period of thirty-six months from the invoice date. The exclusive remedy for any breach or violation of this warranty is as follows: The Baker Company, Inc., will F.O.B. Sanford, Maine, furnish without charge repairs to or replacement of the parts or equipment that proved defective in material or workmanship. No claim may be made for any incidental or consequential damages. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE UNLESS OTHERWISE AGREED IN WRITING SIGNED BY THE BAKER COMPANY. (THE BAKER COMPANY SHALL NOT BE RESPONSIBLE FOR ANY IMPROPER USE, INSTALLATION, SERVICE OR TESTING OF THE GOODS.) P.O. Drawer E, Sanford, ME 04073 (207) 324-8773 (800) 992-2537 Fax: (207) 324-3869 www.bakerco.com AniGARD and EdgeGARD are registered trademarks and StediFLOW is a trademark of The Baker Company. 2012 The Baker Company. All rights reserved. ACB-1000-082012