SOLARREM QUICK START OPERATION MANUAL

Similar documents
Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

PCS 2000 CONTROLLER USER GUIDE PCS 2000 CONTROLLER. Contents

Portable Air-conditioner

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Welcome to Unilux VFC Wall-mount Thermostat

347002K/177002K/34900

User Manual. Dryer Controller M720

Refrigerated air dryers

SunRotor Solar Pump Installation Guide

Geotech Sipper. Installation and Operation Manual. Rev 10/12/2017 Part #

Portable Air Conditioner Instruction Manual

Installation & Operation Manual For ENERGENICS In-Line Space Saver Lint Filters

User Manual. For use with model CS-10A/CS-11A solar ventilation system controllers

Liberty Premium 8. User Instructions

Technical Training Prodigy Undercounter Cubers. Models CU1526, CU2026 and CU3030

SERVICE MANUAL REFRIGERATION

Dolphin Plus Robotic Pool Cleaner Operating Instructions

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Local Air Conditioner

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

Dolphin Bio Suction. Dolphin Bio Suction. User Manual Instructions.

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

DEHUMIDIFIER INSTRUCTION MANUAL

Fog 1550 FT USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

HWD-2110 Hot Water Dispenser


Dryer Controller M720

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

Portable Air-conditioner Use and Care Manual

OPERATION & MAINTENANCE MANUAL AC880

Model 1820 Dehumidifier

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Operation Guide 3408

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Instruction Manual Item No.: V~, 60Hz

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

GLD-30 Gas Leak Detector

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

HEX390 Heat Exchanger

Smart Energy Programmable Thermostat + Energy Monitor. EE542-1Z I User Manual

ADT Home Security Starter Kit. Setup Guide

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat.

CAUTION. Installation Manual

INSTRUCTION FOR THE USER THC V E OIL BLU

Installation and Operations Manual

Agrifim A675CT Timer. Frequently Asked Questions

Owner's Manual TABLE OF CONTENTS

Instruction Manual Item No.: V~, 60Hz

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

LXG-300 Series. Models with LXG-300 Series Instruments

Undercounter Refrigerator Operation Manual

PowerVac G Single to Twin Conversion Kit [ ]

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

HWD-2105 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine.

MacDonald Steel Limited

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Dolphin WAVE 100 Robotic Pool Cleaner Operating Instructions

Dear Valued Customer:

PRODUCTS. Operating Manual

NXM2G Installation and Operating Manual

Dolphin PROX2 GYRO Pool Cleaner. Operating Instructions

Z-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée

Scotsman Technical Training. CU50 Cube Ice Machine

Sensor Control Panel

Model: Edge-HC. 1 edge-hc

Operation Guide 5510

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

Blaze INFO-2. Information Display

Safety / Kit Components 1

Aqua-Gen 3 INSTRUCTIONS

ADT Home Security Starter Kit. Setup Guide

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Dehumidifier. Instruction Manual. Model DH-320/A

Enteral Pump Instructions for Use To Assemble When the low

EXPERT TRI-STAR. Temperature controller. User s Manual

SmartVent. Keypad Controller User Guide Manual. NZ s Home Ventilation Specialists

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

INSTRUCTIONS MANUAL CONTROLS. Description Power Rating Remarks Steamer. Description Power Rating Remarks Control

Trotec PAC FT 2600 Portable air conditioner

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

GeyserWise MAX. Instruction manual. All in one hot water management

AUTOMOTIVE AIR CONDITIONER REFRIGERANT HANDLING SYSTEM

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

GeyserWise MAX. Thermostat instruction manual. SANS 181 compliant. All in one hot water management

Product waste disposal - Protection of the environment:

FLCH4R Garage and Utility Electric Heater

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

Programmable Thermostat

instructions FAN HEATER HVF3533 Please retain these instructions for future reference

Digital Knight 16x20 Automatic Digital Swinger

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Transcription:

SOLARREM QUICK START OPERATION MANUAL INTRODUCTION S larrem Congratulations on the purchase of your SolarRem unit. This quick start manual provides information for the safe installation and operation of your SolarRem unit. Detailed, and supplementary technical information, including performance data, is found in the detailed manual and data sheets. Information about system sizing, design, safety, and operation are available from your SolarRem distributor. Your SolarRem unit is constructed using high quality materials and processes which results in a durable product intended for many years of useful service. We appreciate your patronage and welcome suggestions to improve our products and service. Business office and production facility: Durham Geo Slope Indicator 2175 West Park Ct Stone Mountain Ga 30087 700-465-7557 EQUIPMENT SUPPLIED The SolarNAPL unit comes partially assembled on a pallet with the following components: UNIT SETUP 1. Control box mounted to the air receiver tank 2. Solar Panel (either a 60 Watt or 100 Watt unit) 3. Pre-assembled mounting brackets and fasteners for securing the solar panel to the control box and to a 2 steel pole. 4. Battery, battery box, mounting bracket and fasteners 5. Float level switch and connecting cable 6. In addition, you may have also purchased a pneumatic pump, hosing and support cable. The SolarNAPL unit can be set up on the ground, or pole mounted on at least a 4-inch Schedule 40 steel pole secured a minimum of 1/3 its length into a hole backfilled with concrete. In each situation, the SolarNAPL unit must be secured to ensure it does not get knocked over and sustain damage to the unit or the solar panel assembly. The solar panel and unit should be installed in an area free of any full or partial shading of the panel, as the solar panel will lose considerable output even if only partly shaded. Structures, trees, chimney fences and other potential shading objects should be avoided. Also the prospect of vandalism should be considered. Remove the equipment from the pallet and support the control box and air receiver tank. Assemble the Solar mounting bracket together and place on top of 4 inch pole. Page 1 of 5

With assistance, raise the SolarRem unit to the mounting pole, and fasten in place to the steel pole using the 4 inch conduit clamps secured to the unit through the uni-strut channel. If you have been provided with the battery mount bracket,(optional) connect it to the steel pole using the same universal pipe clamps and assembly. Place and secure the battery box and battery onto the mounting bracket, or the ground. You are now ready to adjust the solar panel into position, connect the wiring and start the SolarRem unit. SOLAR PANEL ADJUSTMENT AND BATTERY CONNECTION We recommend the solar panel be adjusted to the following angles for optimum operation of the unit. With the solar panel horizontal to the ground, tilt the end from the front of the control box downwards to the desired angle. The solar panel must be facing south. We recommend use of a compass. Flat Plate Collectors Facing South at Fixed Tilt Season Tilt Angle from Horizontal Spring Latitude Summer Latitude 15 degrees Fall Latitude Winter Latitude + 15 degrees Connect the battery and solar panel terminals to the wires provided (Battery: red to positive, black to negative Solar Panel: using the red/black molded cable with molded connector. Plug into side of the solar panel If all wiring is connected correctly, you will have power cycling through the unit, and the photovoltaic controller will be active. The supplied battery is an AGM type Deep Cycle marine battery DOWN-HOLE PNEUMATIC PUMP AND RECOVERY TANK INSTALLATION The installation of the down-hole pneumatic pump should be as per proper field engineering protocol. Ensure all safety guidelines and requirements are in place. Connect the air supply line between the pump and SolarNAPL unit. Connect the venting line on the pump (if supplied) and discharge to a suitable location as required. Connect the discharge line between the pump and the product recovery tank. Ensure the discharge line is properly secured to avoid surface spills. Install the float level switch inside the product recovery tank and ensure it is free of all obstructions. Connect the cable between the float and the SolarNAPL unit. Turn on the unit, and check to ensure the float is in the lower position, and there is no HIGH LEVEL signal shutting the SolarNAPL unit down. Ensure the product recovery tank and all interconnecting cables are properly secured to avoid spilling of recovered product. In the event of a spill, notify the authorities immediately and undertake appropriate remediation efforts. START UP OF THE SOLARREM UNIT Once the SolarNAPL unit is properly installed and wired, power should be on to the PLC and controller interface. Make sure the outside Shut-Off button (right side of control box) is initially pressed to the OFF position. Also, the SolarRem unit will not operate unless the recovery tank float is connected and at a low level condition. The table below shows keys for navigating on the controller interface. Function Keys For Navigating on Optimate PLC Controller Solar powered remediation technologies Page 2 of 5

Press Key F1 F2 F3 F4 F5 Menu Up Down Clear/Abort Enter Function System Start System Stop Resets Counters to 0, excluding compressor and PLC timers Non-Self Venting Pump Default Settings (Bladder Type) Self Venting Pump Default Settings To Enter Menu Selection Up Arrow to scroll through list, or increase value Down Arrow to scroll through list, or decrease value To Return to previous screen To select Menu item, and accept new set point Data Pull out the Shut-Off button. Then on the controller interface press the F2 STOP button. Next press the F3 RESET Counters button to set the recording counters to zero (except for PLC and Compressor total run times). If you have installed a Non-Self Venting pump, press the (F4) Yellow button, or for a Self-Venting pump, press the (F5) Black button. The factory preset pumping defaults are as follows: Non-Vent Pump Default Self-Vent Pump Default SolarNAPL Pneumatic Pump Default Settings 4 second SQUEEZE cycle 6 second VENT cycle 12 CYCLES Total 2 hours RESTING Period 1 minute ACTIVE Air Cycle 2 hours RESTING Period Pull out the Shut-Off Button to the ON position. Press the F1 START button on the controller interface, and the SolarNAPL unit will start, with the compressor pump filling the air receiver tank, and the solenoid valve opening to discharge air to the pneumatic pump. On the initial start up (F1 button pressed), for a self-vent pump, the ACTIVE cycle occurs twice before the resting period, to allow for adequate air pressure buildup within the air receiver tank. Your SolarRem unit is now operating. CHANGING TIMING PARAMETERS (ACTIVE AND RESTING CYCLES) To change the timing parameters, press the F2 STOP button. Next press the MENU button, and with the UP/DOWN arrow keys, scroll to the Non-Vent, Self Vent or Resting period parameters as required. Select the item to be changed by pressing the ENTER key to reach the next menu level. Press ENTER a second time for the Self Vent Pump and Resting Time. For the Non-Self Venting Pump selection, use the UP/DOWN arrow keys to scroll through the Non-Self Venting Pump choices, then press the ENTER key a second time to reach the adjustable timers. You will be prompted with the current timer setting. Use the UP/DOWN scroll arrows to change the time, and press the ENTER key to accept the new set time. After pressing the ENTER key, use the ESCAPE/ABORT key to return to the START menu, then press the F1 START key to restart the SolarNAPL unit. A complete flow chart of the Menu Tree is shown below, and detailed further in the full O&M Manual. Solar powered remediation technologies Page 3 of 5

RECORDING OF INFORMATION REGISTERS The Information Registers are obtained from scrolling through the menu under the Menu Tree of INFORMATION REGISTERS. Use these for recording the initial start settings of the SolarNAPL unit, and verifying the operation during return site visits. Operator Controller Interface Main Key Selections Screen Display Description SolarREM Technology Displays at all start up situations and is the default view screen SLCT Menu or F1:Strt SolarREM: STARTING Displays when non operator start from internal PLC countdown Press F2 to STOP SolarREM: RUNNING Displays when the SolarRem unit is operational SLCT F2/OFF to STOP Tank: Hi LEVEL STOP EMPTY TANK + ON/OFF You Have Selected F3 Resets Counters to 0 You Have Selected F4 NonVent Pump Default You Have Selected F5 Venting Pump Default Stop Button Pushed Pull to Restart Unit Displays when the high level float, located in the product storage tank, is activated and stops the pumping operation. Confirmed by the Red Light on top of the SolarRem Control Box. Confirms the reset of counters (excluding pump hours and PLC days) when the (F3) Blue Button selected. Converts current mode of operation to a bladder type pump operation (must vent air back through the solenoid). Sets operation based on 12 squeeze/vent cycles and a resting period of 2 hours between cycles. (F4) Yellow Button selected Converts current mode of operation to a self venting type pump operation (air vents through pump). Sets operation based on an active air time of 1 minute, and a resting period of 2 hours between cycles. (F5) Black Button selected. Displays when the Red Emergency Stop button is pressed on the SolarRem Unit Box. Solar powered remediation technologies Page 4 of 5

Operator Controller Interface Menu Functions Level I Menu Level II Menu Comment Information Register SLCT NONventing Pump SLCT SELF Vent Pump Set RESTING Time Off # High Level Alarms Well Discharge Cycles # Loss of Power # of Times OFF pushed # of Compressor Starts PLC ON Run Days Compressor Run Hours Vent Bladder Time Bladder Squeeze Time Set Squeeze Cycles SLCT Air Cycle Time Rest / Recovery Time Resetable display of the high level alarm conditions from the product storage barrel high level float Resetable display of the total cycles of discharged air to the discharge point. One cycle is one active period and one resting period Resetable display of the total power shut down from a low battery condition, resulting in the shutoff of the power to the PLC Resetable display of the power off condition from pressing the external Emergency Power Off button. Resetable display of the total compressor pump starts to refill the air receiver tank. Non-Resetable timer to display the total duration in days of the PLC operational. Used for maintenance purposes. Non-Resetable timer to display the total compressor pump running hours. Used for maintenance purposes, as the expected compressor pump life around 500 running hours. Sets time the air is vented back through the solenoid, relaxing the bladder and allowing it to refill with product. (Time is set in seconds) Sets time the air is discharged to the bladder pump to squeeze the product up the pump discharge line. (Time is set in seconds) Sets total vent/squeeze cycles during active product removal cycle. Can be adjusted for optimizing product removal with quantity available. Sets the air discharge time during the active cycle to the pneumatic pump. This also removes the nonventing cycle options. (Time is set in 0.1 min. increments) Sets the resting time between active cycles to allow product recovery or resting time. (Time is set in 1.0 minute increments) For specific, or additional information, as well as all maintenance information, please refer to the full Operation and Maintenance Manual Solar powered remediation technologies Page 5 of 5