REGULATION (EU) N. 2016/2281 FOR HIGH TEMPERATURE PROCESS CHILLERS

Similar documents
REGULATION (EU) N. 2016/2281 FOR HIGH TEMPERATURE PROCESS CHILLERS

REGULATION (EU) N. 2016/2281 FOR COMFORT CHILLERS

(Non-legislative acts) REGULATIONS

ANNEXES. to the. COMMISSION REGULATION (EU) No /..

Tutti i modelli / All models : AR70FX / AR70NT / AR70NTV / AR70LTV / AR140 NTV / AR140 LTV AG100 / Q70VP / Q70 VN

COMMISSION REGULATION (EU) No /.. of XXX

COMMISSION REGULATION (EU) No /.. of XXX

Council of the European Union Brussels, 14 July 2014 (OR. en)

Official Journal of the European Union

DRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS

The products covered by the Regulation can be classified as follows:

GENOVA PANORAMA MC. Future. Technology. Innovation.

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

COMMISSION REGULATION (EU) No /.. of

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

COMMISSION REGULATION (EU)

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

SST FOR THE AIR CONDITIONING SYSTEM

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

Delegated Regulation (EU) 626/2011 of 4 May 2011 supplementing Directive 2010/30/EU with regard to energy labelling of air conditioners

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Exclusive technological solutions for tourist facilities

SVENSK STANDARD SS-EN :2004

Dati Tecnici Technical Data

REFRIGERATING SYSTEMS AND HEAT

EN ISO/IEC :2016/AC

Official Journal of the European Union L 239/1. (Non-legislative acts) REGULATIONS

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

CT kg 25 kg C è +3 C +90 C è -18 C. CT V/3N/50Hz Blast chiller Multifunction. Caratteristiche.

Development of an advanced control system for chillers

PAC BT LOW TEMPERATURE HEAT PUMP

COMMISSION REGULATION (EU) No /.. of XXX

PART I ENERGY EFFICIENCY ACQUIS / DELEGATED REGULATION (EU) 811/2013

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Rail Transit HVAC Energy Optimization

Draft COMMUNICATION FROM THE COMMISSION

EXPERIMENTAL STUDY OF THE ENERGY CONSUMPTION IN THE REFRIGERATION PROCESS OF SMALL CABINETS

Fabbricatori di ghiaccio granulare Ice flakers Flockeneisbereiter Machines à glace en grains Fabricadores de hielo in escamas. kg. 120.

HYDRONIC RESIDENTIAL

ProSet Nose Equipment for Avdel Breakstem Rivets

Be sustainable while protecting your business

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

SIRIO Contatore di energia Energy meter

DECLARATION OF CONFORMITY FOR THE MEDICAL DEVICE FAMILY LOW-PRESSURE HOSE ASSEMBLIES FOR USE WITH MEDICAL GASES

Air conditgioner. conditioner AR HVSD AC KNPDEH/AC KXAD H

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

ENSEMBLE DE CONTRÔLE ET RÉGULATION POUR SYSTÈMES DE CHAUFFAGE / CLIMATISATION AVEC POMPE À CHALEUR INVERTER ET APPOINT ÉLECTRIQUE.

The test items passed the test specification(s).

This document is a preview generated by EVS

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

Refrigeration Dryers TH-TI Series

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

RIRS V. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

COMMISSION REGULATION (EU) No /.. of XXX

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

CONTROL UNIT FOR HEATING/COOLING SYSTEMS WITH INVERTER SPLIT HEAT PUMP AND ELECTRICAL BACK UP. APPLICATIONS:

Nicolas Doré Service Bâtiment ADEME Tel : Mail : European normative and regulative context for Gas Heat Pumps

Smart Rules - Smart Application. Introduction to Ecodesign & Energy Labelling

COMMISSION REGULATION (EU) / of

English Version. This Technical Report was approved by CEN on 11 December It has been drawn up by the Technical Committee CEN/TC 135.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Safety instructions Display and adjustment module

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Kylkompressorer och -kondensorer Prestandaprovning och provningsmetoder Del 1: Kylkompressorer

EU GPP Criteria for Water-based Heaters

BLUE ANGEL The German Ecolabel Stationary air conditioners DE-UZ 204 Basic Award Criteria Edition August 2016 Version 1

This FAQ list is intended to be used only for facilitating the implementation of Regulation (EU) 2015/1095 and Regulation (EU) 2015/1094.

SN EN ISO OPRAVA

REFRIGERATING SYSTEMS AND HEAT

IGLU Cold Systems S.r.l. Via Agnelli n 6 / I Villotta di Chions (PN) Italia Tel / Fax home:

This document is a preview generated by EVS

Air Conditioning. Technical Data. 4-way blow ceiling suspended unit EEDEN FXUQ-A

46126-A2 Geothermal Training System

Commission Working Document on possible Ecodesign Requirements for domestic ovens, hobs and range hoods

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

SVENSK STANDARD SS-EN :2005. Ljus och belysning Mätning och presentation av fotometriska data för ljuskällor och ljusarmaturer

WP2 European Product Analysis, Task 2.1 Determining energy efficiency criteria, D 2.1 Periodic Criteria Papers (first set)

High efficiency air to water Heat pumps LZT series

B COMMISSION REGULATION (EU)

Energy efficiency strategies in refrigeration systems of large supermarkets

This document is a preview generated by EVS

Safety instructions VEGATOR 121, 122

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Isola promozionale a Refrigerazione Ventilata (RV) per l esposizione di salumi, latticini o prodotti freschi preconfezionati.

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

A WET-VAPOUR INJECTION AND VARIABLE SPEED SCROLL COMPRESSOR AIR TO WATER HEAT PUMP MODEL AND ITS FIELD TEST VALIDATION

Analysis of a Heat Pump System Driven by Gas Engine for Domestic Use

Come On Labels Common appliance policy All for one, One for all Energy Labels. New EU legislation related to energy labels on household appliances

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Split units, (single room unit and single condenser linked by pipework)

hladnjaci Za vino 126

PROCESS CHILLERS. AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 140 TO 1710 kw R513A. climaveneta.com

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

Saving resources by going evaporative: how evaporative cooling technologies and water cooled chillers can significantly reduce energy

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 81,1 TO 182 kw, AIRFLOW FROM TO m 3 /h

This document is a preview generated by EVS

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Transcription:

Climaveneta Technical Documentation REGULATION (EU) N. 2016/2281 FOR HIGH TEMPERATURE PROCESS CHILLERS Ecodesign requirements for process chillers WATER COOLED CHILLERS FOCS2WY 1301 9604 Cooling Capacity Range 305 363 [kw] (EN14511 VALUE) Nominal Cooling Capacity at TdesignC Range 305 363 [kw]

FOCS2WY 1. REGULATION (EU) N. 2016/2281 FOR HIGH TEMPERATURE PROCESS CHILLERS 1.1 Scope of the document 3 1.2 REGULATION (UE) N. 2016/2281 description 3 1.3 Description of the data declared by Mitsubishi Electric Hydronics & IT Cooling Systems 2. CLIMAVENETA CONTENTS UNIT 2.1 Table index 4 3. TECHNICAL PARAMETERS 3.1 FOCS2WY /CA 5 3.2 FOCS2WY /CAE 7 3 ELCA_Engine ver. 1.0.0.5 DB ver. 1.0.0.0 2

FOCS2WY 1. REGULATION (EU) N. 2016/2281 FOR HIGH TEMPERATURE PROCESS CHILLERS 1.1 Scope of the document This document is compliant with the Commission Regulation (EU) N. 2016/2281 regarding REQUIREMENTS FOR PRODUCT INFORMATION (Annex II, Point 5). In particular, it deals with high temperature process chillers and contains information required by Table 15 of the abovementioned regulation, which is entitled Information requirements for high temperature process chillers. 1.2 REGULATION (UE) N. 2016/2281 description The COMMISSION REGULATION (EU) N. 2016/2281 of 30 November 2016, implementing Directive 2009/125/EC of the European Parliament and of the Council, establishes ecodesign requirements for the placing on the market and/or putting into service of: air heating products with a rated heating capacity which does not exceed 1MW, cooling products and high temperature process chillers with a rated cooling capacity which do not exceed 2 MW, and all fan coil units. All these energyrelated products are defined in Article 2 of the Regulation in question. 1.3 Description of the data declared by Mitsubishi Electric Hydronics & IT Cooling Systems High temperature process chiller: a product designed to cool down and continuously maintain the temperature of a liquid to provide cooling to a refrigerated appliance or system, whose aim is not to provide cooling for the thermal comfort of human beings. It is capable of delivering its rated refrigeration capacity at an indoor side heat exchanger outlet temperature of 7 C, at standard rating conditions. Rated refrigeration capacity (P): the refrigeration capacity that the high temperature process chiller is able to reach when operating at full load at a specific rating point, expressed in kw. Seasonal Energy Performance Ratio (SEPR): the efficiency ratio of a high temperature process chiller at standard rating conditions, representative of the variations in load and ambient temperature throughout the year, and calculated as the ratio between the annual refrigeration demand and the annual electricity consumption. Annual electricity consumption: result of the sum of the ratios between each binspecific cooling demand and the corresponding binspecific energy efficiency ratio, multiplied by the corresponding number of bin hours. Degradation coefficient for chillers: measure of efficiency loss due to cycling of the chiller. Capacity control: the ability of a chiller to change its cooling capacity by changing the volumetric flow rate of at least one of the fluids needed to operate the refrigeration cycle. Global warming potential (GWP) of the refrigerant: the 100year climatic warming potential of one kilogram of a greenhouse gas relative to one kilogram of dioxide (CO2). ELCA_Engine ver. 1.0.0.5 DB ver. 1.0.0.0 3

FOCS2WY 2. CLIMAVENETA CONTENTS UNIT 2.1 Table index WATER COOLED CHILLERS FOCS2WY 1301 9604 Cooling Capacity Range 305 363 [kw] Nominal Cooling Capacity at TdesignC Range 305 363 [kw] Units Version Size Pag. FOCS2WY CA 1301 1401 5 FOCS2WY CAE 1301 1401 7 ELCA_Engine ver. 1.0.0.5 DB ver. 1.0.0.0 4

<<< BACK INDEX UNITS FOCS2WY Type of condensing Refrigerant fluid(s) Type FOCS2WY /CA 1301 Air cooled / Water cooled Information to identify the refrigerant fluid(s) intended to be used with the condensing unit compressor driven vapour compression or sorption process Compressor driven vapour compression Operating temperature t [ C] Seasonal energy performance ratio SEPR 6,84 Annual electricity consumption Q [kwh] 330351 Parameters at full load and reference ambient temperature at rating point A Rated refrigeration capacity P A [kw] 304,89 Rated power input D A [kw] 62,70 Rated energy efficiency ratio EER DC,A 4,86 Parameters at rating point B Rated refrigeration capacity P B [kw] 284,57 Rated power input D B [kw] 47,80 Declared energy efficiency ratio EER DC,B 5,95 Parameters at rating point C Rated refrigeration capacity P C [kw] 264,25 Rated power input D C [kw] 37,20 Declared energy efficiency ratio EER DC,C 7,10 Parameters at rating point D Rated refrigeration capacity P D [kw] 243,92 Rated power input D D [kw] 34,70 Declared energy efficiency ratio EER DC,D 7,02 Other items Capacity control fixed/staged/variable Staged Degradation coefficient for chillers C DC 0,9 GWP of the refrigerant [Kg CO2eq] 1430 Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 31100 Treviso Italy ELCA_Engine ver. 1.0.0.5 DB ver. 1.0.0.0 5

<<< BACK INDEX UNITS FOCS2WY Type of condensing Refrigerant fluid(s) Type FOCS2WY /CA 1401 Air cooled / Water cooled Information to identify the refrigerant fluid(s) intended to be used with the condensing unit compressor driven vapour compression or sorption process Compressor driven vapour compression Operating temperature t [ C] Seasonal energy performance ratio SEPR 6,85 Annual electricity consumption Q [kwh] 375178 Parameters at full load and reference ambient temperature at rating point A Rated refrigeration capacity P A [kw] 346,98 Rated power input D A [kw] 71,30 Rated energy efficiency ratio EER DC,A 4,87 Parameters at rating point B Rated refrigeration capacity P B [kw] 323,87 Rated power input D B [kw] 54,30 Declared energy efficiency ratio EER DC,B 5,96 Parameters at rating point C Rated refrigeration capacity P C [kw] 300,73 Rated power input D C [kw] 42,30 Declared energy efficiency ratio EER DC,C 7,11 Parameters at rating point D Rated refrigeration capacity P D [kw] 277,60 Rated power input D D [kw] 39,50 Declared energy efficiency ratio EER DC,D 7,04 Other items Capacity control fixed/staged/variable Staged Degradation coefficient for chillers C DC 0,9 GWP of the refrigerant [Kg CO2eq] 1430 Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 31100 Treviso Italy ELCA_Engine ver. 1.0.0.5 DB ver. 1.0.0.0 6

<<< BACK INDEX UNITS FOCS2WY Type of condensing Refrigerant fluid(s) Type FOCS2WY /CAE 1301 Air cooled / Water cooled Information to identify the refrigerant fluid(s) intended to be used with the condensing unit compressor driven vapour compression or sorption process Compressor driven vapour compression Operating temperature t [ C] Seasonal energy performance ratio SEPR 7,47 Annual electricity consumption Q [kwh] 317033 Parameters at full load and reference ambient temperature at rating point A Rated refrigeration capacity P A [kw] 319,45 Rated power input D A [kw] 60,10 Rated energy efficiency ratio EER DC,A 5,32 Parameters at rating point B Rated refrigeration capacity P B [kw] 298,20 Rated power input D B [kw] 45,60 Declared energy efficiency ratio EER DC,B 6,54 Parameters at rating point C Rated refrigeration capacity P C [kw] 276,90 Rated power input D C [kw] 35,70 Declared energy efficiency ratio EER DC,C 7,76 Parameters at rating point D Rated refrigeration capacity P D [kw] 255,60 Rated power input D D [kw] 33,50 Declared energy efficiency ratio EER DC,D 7,64 Other items Capacity control fixed/staged/variable Staged Degradation coefficient for chillers C DC 0,9 GWP of the refrigerant [Kg CO2eq] 1430 Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 31100 Treviso Italy ELCA_Engine ver. 1.0.0.5 DB ver. 1.0.0.0 7

<<< BACK INDEX UNITS FOCS2WY Type of condensing Refrigerant fluid(s) Type FOCS2WY /CAE 1401 Air cooled / Water cooled Information to identify the refrigerant fluid(s) intended to be used with the condensing unit compressor driven vapour compression or sorption process Compressor driven vapour compression Operating temperature t [ C] Seasonal energy performance ratio SEPR 7,46 Annual electricity consumption Q [kwh] 360779 Parameters at full load and reference ambient temperature at rating point A Rated refrigeration capacity P A [kw] 363,26 Rated power input D A [kw] 68,20 Rated energy efficiency ratio EER DC,A 5,33 Parameters at rating point B Rated refrigeration capacity P B [kw] 339,08 Rated power input D B [kw] 51,90 Declared energy efficiency ratio EER DC,B 6,53 Parameters at rating point C Rated refrigeration capacity P C [kw] 314,86 Rated power input D C [kw] 40,60 Declared energy efficiency ratio EER DC,C 7,76 Parameters at rating point D Rated refrigeration capacity P D [kw] 290,64 Rated power input D D [kw] 38,10 Declared energy efficiency ratio EER DC,D 7,63 Other items Capacity control fixed/staged/variable Staged Degradation coefficient for chillers C DC 0,9 GWP of the refrigerant [Kg CO2eq] 1430 Contact details: Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A., via L. Seitz 47 31100 Treviso Italy ELCA_Engine ver. 1.0.0.5 DB ver. 1.0.0.0 8

FOCS2WY ENGLISH ITALIANO FRANCAISE DEUTSCH ESPANOL Type of condensing Tipo di condensazione Type de condensation Art der Verflüssigung Tipo de condensación Refrigerant fluid(s) Fluido(i) refrigerante(i) Fluide(s) frigorigène(s) Kältemittel Fluido o fluidos refrigerantes Type Tipo Type Bauart Tipo Operating temperature Temperatura di esercizio Température de service Betriebstemperatur Temperatura de funcionamiento Seasonal energy performance ratio Annual electricity consumption Parameters at full load and reference ambient temperature at rating point A Rated refrigeration capacity Indice di prestazione energetica stagionale Consumo annuo di energia elettrica Parametri a pieno carico e alla temperatura ambiente al punto di valutazione A Capacità dichiarata di refrigerazione Ratio de performance énergétique saisonnier Consommation annuelle d'électricité Paramètres à pleine charge et à la température ambiante de référence au point d'évaluation A Puissance de réfrigération nominale Jahresarbeitszahl Jahresstromverbrauch Parameter bei Volllast und Bezugsumgebungstemperatur am Bewertungspunkt A Nennkälteleistung Factor de rendimiento energético estacional Consumo anual de electricidad Parámetros a plena carga y a temperatura ambiente de referencia en el punto de clasificación A Potencia nominal de refrigeración Rated power input Potenza nominale assorbita Puissance absorbée nominale Nennleistungsaufnahme Potencia utilizada nominal Rated energy efficiency ratio Parameters at rating point B Rated refrigeration capacity Indice di efficienza energetica nominale Parametri al punto di valutazione B Capacità dichiarata di refrigerazione Coefficient d'efficacité énergétique nominal Paramètres au point d'évaluation B Puissance de réfrigération nominale Nennleistungszahl Parameter am Bewertungspunkt B Nennkälteleistung Factor de eficiencia energética nominal Parámetros en el punto de clasificación B Potencia nominal de refrigeración Rated power input Potenza nominale assorbita Puissance absorbée nominale Nennleistungsaufnahme Potencia utilizada nominal Declared energy efficiency ratio Parameters at rating point C Rated refrigeration capacity Indice di efficienza energetica dichiarato Parametri al punto di valutazione C Capacità dichiarata di refrigerazione Coefficient d'efficacité énergétique declaré Paramètres au point d'évaluation C Puissance de réfrigération nominale Nennleistungszahl Parameter am Bewertungspunkt C Nennkälteleistung Factor de eficiencia energética nominal Parámetros en el punto de clasificación C Potencia nominal de refrigeración Rated power input Potenza nominale assorbita Puissance absorbée nominale Nennleistungsaufnahme Potencia utilizada nominal Declared energy efficiency ratio Parameters at rating point D Rated refrigeration capacity Indice di efficienza energetica dichiarato Parametri al punto di valutazione D Capacità dichiarata di refrigerazione Coefficient d'efficacité énergétique declaré Paramètres au point d'évaluation D Puissance de réfrigération nominale Nennleistungszahl Parameter am Bewertungspunkt D Nennkälteleistung Factor de eficiencia energética nominal Parámetros en el punto de clasificación D Potencia nominal de refrigeración Rated power input Potenza nominale assorbita Puissance absorbée nominale Nennleistungsaufnahme Potencia utilizada nominal Declared energy efficiency ratio Indice di efficienza energetica dichiarato Coefficient d'efficacité énergétique declaré Nennleistungszahl Factor de eficiencia energética nominal Other items Altri elementi Autres caractéristiques Sonstige Produktdaten Otros elementos Capacity control Degradation coefficient for chillers Declared energy efficiency ratio or gas utilisation efficiency/auxiliary energy factor for part load at given outdoor temperatures Tj Dispositivo di controllo della capacità Coefficiente di degradazione per i refrigeratori Indice di efficienza energetica dichiarato o efficienza dell'uso del gas/fattore di energia ausiliaria a carico parziale alle temperature esterne date Tj Régulation de la puissance Leistungsregelung Control de la potencia Coefficient de dégradation pour les refroidisseurs Coefficient d'efficacité énergétique déclaré ou rendement de la consommation de gaz/indice énergétique auxiliaire à charge partielle pour des températures extérieures données Tj Minderungsfaktor von Kühlern Angegebene Leistungszahl oder Gaswirkungsgrad/Hilfsenergiefa bei Teillast und bestimmten Außentemperaturen Tj GWP of the refrigerant GWP del refrigerante PRP du fluide frigorigène Treibhausgaspotenzial des Kältemittels Notes: Note: Remarques: Hinweise: Notas: The parameters are declared for application at medium temperature, except in the case of low temperature heat pumps. For low temperature heat pumps, the parameters are declared for application at low temperature. Unit in standard configuration/execution, without optional accessories. I parametri sono dichiarati per l applicazione a temperatura media, tranne per le pompe di calore a bassa temperatura. Per le pompe di calore a bassa temperatura, i parametri sono dichiarati per l applicazione a bassa temperatura. Unità in configurazione ed esecuzione standard, priva di accessori opzionali. Les paramètres sont déclarés pour l application à moyenne température, excepté pour les pompes à chaleur basse température. Pour les pompes à chaleur basse température, les paramètres sont déclarés pour l application à basse température. Unité en configuration et exécution standard, sans accessoires optionnels. Die Parameter sind für eine Mitteltemperaturanwendung anzugeben, außer für NiedertemperaturWärmepumpen. Für NiedertemperaturWärmepumpen sind die Parameter für eine Niedertemperaturanwendung anzugeben. Gerät mit StandardKonfiguration und Ausführung, ohne wunschweises Zubehör. Coeficiente de degradación de las enfriadoras Factor de eficiencia energética declarado o eficiencia del uso de gas o factor de energía auxiliar para carga parcial a las temperaturas exteriores dadas Tj PCA del refrigerante Los parámetros se declararán para aplicaciones de media temperatura, excepto si se trata de bombas de calor de baja temperatura. En el caso de las bombas de calor de baja temperatura, los parámetros se declararán para aplicaciones de baja temperatura. Unidad en configuración y ejecución estándar, sin accesorios opcionales. ELCA_Engine ver. 1.0.0.5 DB ver. 1.0.0.0 9

PRODUCT GUIDE_ENG_022018