Commercial PATIO HEATER

Similar documents
COSY CLASSIC Portable Infra-Red open-air heater for non residental space heating Assembly and usage instructions. WARNING! For Outdoor Use Only.

COSY CLASSIC Portable Infra-Red open-air heater for non residental space heating Assembly and usage instructions. WARNING! For Outdoor Use Only.

RETRACTABLE. Expand your life

Outdoor Patio Heater

Outdoor Patio Heater

Outdoor Patio Heater INFRARED BURNER

Serial Number Purchase Date

Red Ember Outdoor Patio Heater with Table

Outdoor Patio Heater INFRARED BURNER

Owner's Manual. OUTDOOR FIRE PIT TABLE Item # 62145

Outdoor Patio Heater INFRARED BURNER Model # LIP-10A-TGG-LPG-SP Item # 01775

Outdoor Patio Heater Instruction Manual Model# PH01-S, PH01-SS Item # 60788,60368,60485,60786,61185,61444,61546,61547

Patio Heater_ _V4_ENG.book Page 1 Tuesday, September 2, :00 AM. AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

Outdoor Flame Heater

Comfort, Quality & Style Since 1998

Comfort, Quality & Style Since 1998

Owner's Manual OUTDOOR FIRE PIT TABLE ITEM # 62195

OUTDOOR FIRE PIT ITEM # 61860

Owner s Manual. 36" Square Gas Fire Pit Model#SRGF11610 DANGER WARNING. WARNING: For Outdoor Use Only.

OUTDOOR FIRE PIT TABLE ITEM # 62082

BLT-999W-2 Item # 60757

Owner s Manual OUTDOOR FIRE PIT ITEM # 61168

35" Square Gas Fire Pit Model#SRGF11603B

Assembly Instructions & User s Manual

INSTALLATION INSTRUCTIONS AND OWNER S MANUALS

AXIS OUTDOOR HEATER. Owner s Manual DANGER WARNING

User Manual No. 8 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , OUTDOOR PATIO HEATER

Comfort, Quality & Style Since 1998

Outdoor Patio Heater Instruction Manual Model# PH08-SB & PH08-SSB Item # 61220, 61221

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

BRONZE HSC PATIO HEATER. Call center for missing parts IMPORTANT DO NOT RETURN MODEL NO.: PG195H

User Manual No. 5 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , OUTDOOR PATIO HEATER

ASSEMBLY INSTRUCTIONS

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Stoneridge Fire Pit High Dining Table Assembly Instruction

Owner s Manual TABLETOP PATIO HEATER MODEL # PHRDGH/SS-TT

User Manual No. 1 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , , OUTDOOR PATIO HEATER

GAS-FIRED INFRARED OUTDOOR PATIO HEATER

GAS-FIRED INFRARED OUTDOOR PATIO HEATER INSTALLATION, OPERATION MAINTENANCE INSTRUCTIONS

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

GAS PATIO HEATER WITH LED TABLE. Call center for missing parts IMPORTANT DO NOT RETURN MODEL NO.: PG188H

TERRACE AND PATIO HEATER

Warning: For OUTDOOR USE only

TERRACE AND PATIO HEATER

Wine Barrel Fire Pit. Owner s Manual. Item # 9716 DANGER

Comfort, Quality & Style Since 1998

Owner s Manual M odel # F-1350-FPT OUTDOOR FIRE PIT TABLE

ANS Z , Outdoor Decorative Gas Appliances CGA CR Outdoor Gas Fireplaces

OUTDOOR FIRE PIT FPS-DGHSS. ANS Z , Outdoor Decorative Gas Appliances CGA CR Outdoor Gas Fireplaces

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

TABLE TOP PATIO HEATER Owner s Manual

Bellante Woven Aluminum Round LPG Fire Pit WARNING. Questions, problems, missing parts? lntertek. Item#: WARNING WARNING FOR YOUR SAFETY

GAS-FIRED INFRARED OUTDOOR PATIO HEATER

CYLINDER NOT INCLUDED

Owner s Manual OUTDOOR LIVING PERFECTED TONGA TORCH PORTABLE PROPANE

Dashley Outdoor Fire Table

PAULIN PRODUCTS INDOOR HEATER

ANSI Z /CSA Gas-Fired Outdoor Infrared Patio Heaters. ANS Z /CSA Gas-Fired Outdoor Infrared Patio Heaters

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

OUTDOOR PATIO HEATER MODEL #HSS-RS-GH. Model: HCPH MRKT / HCPHSSRKT

UNIT MUST BE ON A DEDICATED ELECTRICAL CIRCUIT. Owner s Manual Models: 02117/02678 INFRARED HEATER POLE SET

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

Repeat procedures for other side.

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL # ZCV-2670-SS

Natural Gas Patio Heaters

User Manual No. 6 WARNING. WARNING: For Outdoor Use Only WARNING DANGER. Models: , OUTDOOR PATIO HEATER

USE AND CARE GUIDE PEDESTAL FIREBOWL

OUTDOOR PATIO HEATER WARNING. WARNING: For Outdoor Use Only WARNING DANGER DANGER MODEL #GS-2400-BRZ GS-2400-BLK GS-2650-SS

ASSEMBLY INSTRUCTIONS

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL:PHTRGH/SS MADE IN CHINA

Owners Manual Manual del Usuario

Propane Tabletop Patio Heater

MODEL: CGG-306 Chef s Style Portable Tabletop Grill ASSEMBLY AND OPERATING INSTRUCTIONS

Owner s Manual K BTU PATIO HEATER Model# SRPH33A Instructions Manual DANGER WARNING WARNING

Aluminum Linear Fire Table

These instructions are for your safety. Please read them thoroughly before use and retain them for future reference

Del Rio Tile Top Fire Pit Table

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Using it in an enclosed space can kill you.

ASSEMBLY INSTRUCTIONS

For assistance with assembly, please contact Hayneedle Customer Care Center

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

Riaza Tablemount Fire Bowl. Item# Model# HYUTT DANGER If you smell gas: 1. Shut off gas to the appliance.

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL # HSS-RS-TB

Owner s Manual DANGER WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER

Table Top Patio Heater

OWNER S MANUAL DANGER WARNING. WARNING: For Outdoor Use Only WARNING PATIO HEATER MODEL # HLDS01. Français p. 22. p. 43

OWNER S MANUAL DANGER WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR GAS FIREPIT MODEL # AFP-RT

Assembly & User Instructions Mirage 38,200Btu Heat Focusing Patio Heater

Owners Manual Manueal d Utilisation

USE AND CARE GUIDE. Back Painted 32 x32 Fire Pit. 11in. 17in

USE AND CARE MANUAL. Home Garden. For Model T87PHLP. Stop! Missing a part? DO NOT RETURN PRODUCT TO STORE

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING LAVA LITE KD

Transcription:

Commercial PATIO HEATER FIRESENSE 48,000 BTU COMMERCIAL PATIO HEATER WARNING! For Outdoor Use Only. WARNING! Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. Save these instructions for future reference. Please ensure the owner of the heater retains the manual for future reference. ANS Z83.26-2007 / CSA 2.37-2007 Gas-Fired Infrared Patio Heater ITEM # 61541 US Portable Infra-Red open-air heater for non residental space heating Assembly and usage instructions Questions, problems, missing parts? Before returning to your retailer, call our customer service hotline at 1-866-985-7877, 9 a.m. 6 p.m., EST, Monday Friday or email at cservice@welltraveled.net.

US WARNING WARNING FOR YOUR SAFETY California Proposition 65: If you smell gas: Chemicals known to the state of 1. Shut off the gas to the appliance. California to cause cancer, birth 2. Extinguish any open flame. defects, or other reproductive 3. If odor continues, keep away from harm are created by the combustion of propane. the appliance and immediately call your gas supplier or fire de- WARNING partment. - Purchaser assumes all risk in the WARNING assembly and operation of this unit. FOR YOUR SAFETY Failure to follow this manual s 1. Gas leaks may cause a fire or ex- WARNINGS and instructions can plosion which can cause serious result in severe personal injury, bodily injury, death or damage to death or property damage. - Do not use in an explosive property. atmosphere. Keep heater away 2. You must follow all leak checking procedures as outlined in step 8 from areas where flammable before operating this unit. liquids, gasoline, vapours, or explosives are stored or used. 3. Never use an open flame to check for leaks. WARNING WARNING FOR YOUR SAFETY Beware of sharp edges, ensure Do not store or use gasoline gloves are worn on assembly. or other flammable vapours and liquids in the vicinity of this or any other appliance. An LP-cylinder not connected for use shall not be stored in the vicinty of this or any other appliance. 2

COMMErCIAL 61541 TABLE OF CONTENTS Page 1 SAFETY FIRST 4-5 2 ASSEMBLY INSTRUCTIONS in 11 steps 6-13 3 OPERATION 14 3.1 BEFORE TURNING GAS SUPPLY ON 14 3.2 BEFORE LIGHTING 15 3.3 LIGHTING 16 3.4 WHEN HEATER IS ON 16 3.5 RE-LIGHTING 16 3.6 SHUTDOWN 16 4 OPERATION CHECKLIST 17 5 CLEANING & MAINTENANCE 18 6 STORAGE 18 7 SPECIFICATIONS 19 8 SERVICE ADDRESS 19 9 WARRANTY 20 The use and installation of this product must conform to local codes. In absence of local codes, use the National Fuel and Gas Code, ANSI Z223, 1/NFPA 54, Storage and Handling of Liquid Petroleum Gases, ANSI/NFPA 58 or CSA B149.1, Natural Gas and Propane Installation Code. The installation must confirm with local building codes or, in the absence of local codes, with the current CAN 1-B149 installation codes. THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURE`S AUTHORISED REPRESENTATIVE, IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER, PROVINCAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES 3

US 1. SAFETY FIRST! Read and become familiar with this entire manual especially the following precautions. If you are unsure of anything in these instructions, STOP and contact for assistance. Caution: This application is for outdoor use only (outside any enclosure). Always make sure there is fresh air ventilation. Always maintain at least 36 clearance (top) and 24 clearance (side) from combustible materials. Always place heater on a hard and level surface and mounted. Do not use if the wind velocity is greater than 10 miles per hour. Unit will operate at reduced efficiency below 40 F (5 C). Keep sprinklers and other water sources away from burner and controls. Ceiling Always use extreme caution when near heater. Alert both children and adults to the hazards of high temperatures, especially to avoid burns or clothing catching fire. 36 " Young children and pets should be carefully supervised when they are in the area of the heater. 24 " Do not hang clothing or other flammable materials either on or near the heater. Wall Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater. Certain materials o r items, when stored under the heater, will be subjected to radiant heat and could be seriously damaged. Do not alter heater in any manner. The pressure regulator and hose assembly supplied with the appliance must be used and replacements must be those specified by the manufacturer. If regulator becomes damaged, use only a factory-supplied replacement. lnspect heater before each use. If a damaged part is detected, do not operate until an original equipment replacement part has been properly installed. Use of unauthorized parts will void warranty and create an unsafe condition. Please call 847 850 5335 for help! Prior to operating the heater, replace any guards or protective devices removed for servicing. During operation, do not touch the burner assembly. The surface of the heater s emitter can reach temperatures approaching 1600 F After shutdown, do not touch the burner assembly until the heater has cooled (approximately 45 minutes after use). Notice: This product should not be used with any fuel other than liquid propane. Use of other fuels will detract from the heaters performance and will void your warranty. The used LP-gas cylinder must be: a Constructed an marked in accordance with the Specifications for LP-gas cylinders of the U.S. Department of Transportation (DOT); or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commisiion, CAN/ CSA-B339, as applicable; b Provided with a listed overfilling prevention device; and c Provided with a cylinderconnection device compatible with the connection for the appliance. Storage of an appliance indoors is permissible only if the cylinder is disconected and removed from the appliance. A cylinder must be stored outdoors in a well ventilated area out of the reach of children. A disconnected cylinder must have dust caps tightly installed and must not be stored in a building, garage or any other enclosed area. Do not store a spare LP-gas cylinder under or near this appliance. Never fill the cylinder beyond 80 percent full. If the information above is not followed exacly, a fire causing death or serious injury may occur. 4

COMMErCIAL 61541 Caution: Liquid propane (LP) gas is flammable and hazardous if handled improperly. Become aware of the characteristics before using any LP product. LP Characteristics Flammable, explosive under pressure, heavier than air - settles in pools in low areas. In its natural state, propane has no odor. For your safety, an odorant is added and has a bad smell. Contact with LP can cause freeze burns to skin. This heater is shipped from the factory for LP gas use only. Use only Department of Transportation (DOT) approved 20 Ib. LP gas tanks (Same as those commonly used on gas grills) with Acme / Type 1 / QCC safety valves. These valves can be quickly identified because they have external and internal threads. Never use an LP tank with a damaged body, valve, collar, or foot ring. Dented or rusted LP tanks may be hazardous and should be checked by your LP gas supplier. The tank supply system must be arranged for vapour withdrawal. The tank used must include a collar to protect the tank valve. When heater is not in use, turn LP tank 0FF. Always perform a leak test on gas connections whenever a tank is connected. Never use a flame to test for leaks. Do not smoke while performing a leak test. Caution: It is essential to keep the heater s valve compartment, burners, and circulating air passages clean. Spiders and insects can create a dangerous condition that may damage the heater or make it unsafe. Keep the burner area clean of all spiders, webs, or insects. lnspect the heater before each use. Have heater inspected annually and repairs should be made by a qualified service person. Check the heater immediately if any of the following conditions exist: The smell of gas in conjunction with extreme yellow tipping of burner flames. Heater does not reach the proper temperature. Note: At temperatures less than 40 F, heat output will be reduced. FOR YOUR SAFETY BEARE OF SPIDERS Spiders or small insects can get into the burner tube or other openings of your heater and spin webs or build nests. These obstructions can lead to gas flow problems. It is important to make frequent inspections of these areas and clean them when necessary. Before operating your heater for the first time, be sure to check for obstructions that may have occurred during shipment. Heater s glow is excessively uneven Burner makes popping noises during use. Note: A slight pop is normal when burner is extinguished. Carbon deposits may create a fire hazard. Keep dome and emitter clean at all times. Do not clean heater with combustible or corrosive cleaners. Use warm, soapy water. Do not paint the burner, the burner access panel or dome. 5

US 2. ASSEMBLY INSTRUCTIONS 8 mm 10 mm 14 mm 16 mm 6

COMMErCIAL 61541 1 4 2 7 5 6 8 7 9 10 3 12 11 M5x12 14 11x M6x12 13 13x 15 Ø5,3 13x 18 M6 16 13x 19 320mm 1x 20 400mm 1x M5 17 Ø6.3 11x 7 11x

US To avoid cuts, you have to wear safety gloves during installation. Get help by a second person during the installation. 1 Remove the protective foil from all parts first! 11 22 23 24 25 26 27 27 26 25 24 23 22 2 3x 8 14 9 17 18 8

COMMErCIAL 61541 3 10 5 4 7 6 5x 13 15 9 16

US 5 4x 16 13 15 6 5 20 10

COMMErCIAL 61541 7 5 8 4 4x 4 16 13 15 6+7 20 11

US 9 18 17 14 3 14 17 19 18 19 10 1 1 2 2 12 17 3x 18 3x

COMMErCIAL 61541 11 14 14 3 LEAK CHECKING see page 14 5 12 12 13

US 3. OPERATION Caution: Do Not attempt to operate the heater until you have read and understood the warnings section in this manual. MOUNT THE HEATER ON THE GROUND FIRST! 3.1 TURNING THE GAS SUPPLY ON CONNECT THE GAS HOSE AND REGULATOR ASSEMBLY TO THE TANK Note: Use only a Department of Transportation (DOT) approved 20 pound cylinder with an ACME/ Type 1 connection with QCC (Quick Connect Coupler)safety valves. When the Cylinder is empty it should wheight 18 pounds. CHECK FOR LEAKS: Make a solution of 2-3 oz. of leak checking solution by mixing one part liquid dishwashing soap and three parts water. Follow the procedure below: LEAK CHECKING FUEL TUBE CONNECTION Step 1: Turn cylinder valve on by turning anti-clockwise. Step 2: Check fuel tube connection for leaks. To check for leaks spoon several drops of solution onto the connections as illustrated. Step 3: Inspect the solution for bubbles. If no bubbles appear then the connection is secure. If bubbles appear, then there is a leak: Turn OFF the cylinder valve. Undo the connection and inspect the surface of the cone to make sure they are clean. Reconnect by using two wrenches, one on either side of the connection. Repeat the leak checking procedure described above. If you still see bubbles after several attempts DO NOT USE THE HEATER. Contact service for assistance. 14

COMMErCIAL 61541 LEAK CHECKING GAS LINE AND CYLINDER CONNECTIONS Step 1: Turn cylinder valve on by turning anti-clockwise. Step 2: Check connections and valve for leaks. To check for leaks spoon several drops of solution onto the connections as illustrated. Step 3: Inspect the solution for bubbles, if no bubbles appear then the connection is secure. If bubbles appear, then there is a leak: Turn OFF the cylinder valve. Release the regulator connection to the cylinder. Reattach the regulator, making sure that the connection is tight. Repeat the leak checking procedure described above. If you still see bubbles after several attempts DO NOT USE THE HEATER. Contact service for assistance. - X Your heater was designed and approved for Outdoor use only. Do NOT use it inside an enclosure. X Make sure that all combustibles are maintained and that there are no flammable liquids or vapors in the vicinity of the heater. Make sure there is no obstruction to air ventilation. Be sure that all gas connections are tight and there are no leaks. Any components removed during the assembly or servicing of the heater must be reinstalled. X X X 3.2 BEFORE LIGHTING - The heater components should be thoroughly inspected before each use and at least every two years by a qualified service person. Inspect the visible portion of the hose before each use of the appliance. Portions that are located within the heater post, inspect the entire hose assembly at least annually. The hose assembly must be replaced prior to the appliance being put into operaton if there is evidence of excessive abrasion or wear, or if the hose is damaged. The replacement hose assembly shall be that specified by the manufacturer. 16 mm LEAK CHECKING see page 14 15 19 mm

US 3.3 LIGHTING 1. Push control knob IN and turn to OFF. WARNING 2. Turn the gas tank valve ON. FOR YOUR SAFETY 3. Depress the burner control knob and turn it (anticlockwise) to the igniting position. Be careful when attempting to manually ignite this heater. Holding in the control knob for more than 5 seconds before igniting the gas will cause a ball of flame upon ignition. 4. Press the piezo-ignition concurrently with your other hand and hold the pressed knob for about 10 seconds after ignition in order to activate the ignition safety switch. Should the gas fail to ignite after pressing the piezo-ignition 3 or 4 times, leave the appliance for about 5 minutes that any gas to clear and then repeat the process. Note: It is possible to ignite the burner using other ignition devices (gas lighters, matches) through the 0.73 inch aperture in the bottom of the burner. Caution: Avoid inhaling fumes emitted from the heater s first use. Smoke and odour from the burning of oils used in manufacturing will appear. Both smoke and odor will dissipate after approximately 30 minutes. The heater should NOT produce thick black smoke. Note: The burner may be noisy when initially turned on. To eliminate excessive noise from the burner, turn the Control Knob to the small flame position. Then, turn the knob to the level of heat desired. 3.4 WHEN HEATER IS ON Emitter screen will become bright red due to intense heat. The colour is more visible at night. Burner will display tongues of blue and yellow flame. These flames should not be yellow or produce thick black smoke, indicating an obstruction of airflow through the burners. The flame should be blue with straight yellow tops. 3.5 RE-LIGHTING Turn Control Knob to 0FF Wait at least 5 minutes, to let gas dissipate, before attempting to relight. Repeat the Lighting steps on prior page. 3.6 SHUTDOWN WARNING 1. Turn the burner control knob clockwise to the igniting position. FOR YOUR SAFETY 2. Depress the control knob and turn it clockwise to OFF. Heater will be hot after use 3. Turn tank valve clockwise to OFF. Disconnect the regulator when heater is not in use. Handle with extreme care Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided by the cylinder valve. Other types of caps or plugs may result in leakage of propane. 16

COMMErCIAL 61541 4. OPERATION CHECKLIST For a safe and pleasurable heating experience, perform this check before each use. BEFORE OPERATING I am familiar with entire owner s manual and understand all precautions noted in Safety First. All components are properly assembled, intact and operable. No alterations have been made. All gas connections are secure and do not leak. Wind velocity is below 10 mph. Outdoor temperature is greater than 40 degrees F. Heater is outdoors (outside any enclosure). There is adequate fresh air ventilation. Heater is away from gasoline or other flammable liquids or vapors. Heater is away from windows, air intake openings, sprinklers and other water sources. Heater is at least 36 clearance (top) and 24 clearance (side) of combustible materials. Heater is on a hard and level surface. There are no signs of spiders or insect nests. All burner passages are clear. All air circulation passages are clear. Children, pets, clothing, flammable materials and items that can be damaged from radiant heat are away from the heater. Children and adults in the area have been alerted to the high temperature hazards: especially burns and clothing fires. Children and adults in the area have been warned not to touch the heater near the burner during operation and until unit has cooled. AFTER OPERATION Gas control is in 0FF position. Gas tank valve is 0FF Disconnect Gas Line. Heater is upright in a secure location. 17

US 5. CLEANING AND MAINTENANCE Your heater has been produced from highly weather resistant materials and only minimum cleaning and maintenance is required. Cleaning must be performed when the heater is cold. Your patio heater will live longer if it is cleaned and maintained properly. It is very important that the air required for the combustion process is not blocked going to the burner. Vents and other openings must be kept free of dirt and spiders webs. The burner lower part is one unit. You can not clean it. Stainless steel models: Use a stainless steel cleaner product on the main components of the heater, cylinder cover, base and post. Never use a cleaning agent that is flammable or corrosive. Never spray any cleaning product on the emitter grid or burner area. Painted models: Wash all painted parts of the heater with a soapy solution and protect it with a coat of automobile car wax a couple of times per year or as required dependent upon your local weather and climate conditions. If you need to touch up a painted heater only paint the post and base portions. Never paint the emitter grid, lighting instructions, valve or control knob area or the LP cylinder! The burner ports must also be kept clear so that the burner burns evenly and the flow of gas is not restricted. If the heater is not performing adequately it will be necessary to check the burner. In a salt air or ocean enviroment, corrosion and rust occur at a far greater rate than in non-ocean areas. You will need to check more frequently for corrosion and replace parts as required. 6. STORAGE - Turn control knob OFF - Disconnect LP source and move to secure, well-ventilated location outdoors. - Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet, hail, snow, dust and debris). - If desired, cover heater to protect exterior surfaces and to help prevent build up in air passages. - Never leave the LP cannister exposed to direct sunlight or excessive heat. - Note: Wait until heater is cool before covering. - If using a cover, ensure is is tightly fitted or secured support it during high winds. 18

COMMErCIAL 61541 7. SPECIFIACTIONS Certifications: ANS Z83.26/CSA 2.37-2007 Gas Fired Outdoor Infrared Patio Heater Rating: Maximum 48,000 BTU/hr. input Heat Range: Up to 20 foot diameter Fuel: Liquid Propane Gas (LP) Tank Size: Nominal 20 lb / 5 Gallon Inlet gas supply pressure: Maximum 150 PSI Minimum 5 PSI Mainfold Pressure: 11.00 in.w.c. Safety Features: 100% Burner shut-off Tilt switch Manufacturer: Enders Colsman AG Made in: P. R. China 8. SERVICE ADDRESS Before returning to your retailer, call our customer service hotline at 1-866-985-7877, 9 a.m. 6 p.m., EST, Monday Friday or email at cservice@welltraveled.net. Well Traveled Living P.O. Box 4 Amelia Island, FL 32035 Email: cservice@welltraveled.net 19

Distributed By: Well Traveled Living 716 S 8th Street Amelia Island, FL 32034 Toll Free: 866-WTL-SUPP (866-985-7877) Web: www.wtliving.com Email: cservice@welltraveled.net 1 YEAR LIMITED WARRANTY Customers in the Continental US All components are warranted for a period of 1 year after date of purchase by the original owner against defects in materials and workmanship under normal use. This warranty does NOT cover normal wear and weathering, assembly and/or maintenance OR use in a commercial application if model is not designated as a commercial model. At Well Traveled Living s sole discretion, products under warranty will be repaired and/or replaced at no charge to the customer. Any returns sent back to Well Traveled Living must be sent via prepaid freight and in the original retail packaging. For warranty service contact Well Traveled Living at the address, phone numbers or internet site and email listed in this owner s manual. Be sure to have your sales receipt, date of purchase and catalogue/model numbers available when calling. All warranty service will be coordinated by the Well Traveled Living s, Amelia Island, Florida service center. This warranty is extended only to the original purchaser. Proof of purchase will be required before warranty service is rendered. The sales receipt is the only valid proof of purchase. This warranty only covers failures due to defects in materials or workmanship which occur during normal use. Failures and/or damage which result from accident, negligence, misuse, abuse, neglect, mishandling, alteration or modification, failure to maintain, improper assembly or maintenance, service by unauthorized agency or use of unauthorized components or damage that is attributable to acts of God are NOT covered. ***THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED ABOVE*** ***PURCHASER ASSUMES ALL RISKS IN THE ASSEMBLY AND OPERATION OF THIS UNIT*** ***FAILURE TO FOLLOW WARNINGS AND OPERATIONAL INSTRUCTIONS CONTAINED IN THIS MANUAL CAN RESULT IN SEVERE PROPERTY DAMAGE AND/OR PERSONAL INJURY*** IN NO EVENT WILL WELL TRAVELED LIVING, OR ITS DIRECTORS, OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY, WHETHER IN CONTRACT, IN TORT, OR ON ANY OTHER BASIS, FOR ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY, CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE, MAINTENANCE, USE, OR INABILITY TO USE THE PRODUCT, EVEN IF WELL TRAVELED LIVING OR ITS DIRECTORS, OFFICERS OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES, OR IF SUCH LOSSES, COSTS, OR DAMAGES ARE FORESEEABLE. IN NO EVENT WILL WELL TRAVELED LIVING, OR ITS OFFICERS, DIRECTORS, OR AGENTS BE LIABLE FOR ANY DIRECT LOSSES, COSTS OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER. This limited warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. The provisions of the United Nations Convention on Contracts for the Sales of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty. ***IMPORTANT NOTICE*** -Do NOT return to place of purchasefor customer service and warranty issues contact our Customer Service Center at: (866)-985-7877 OR Email: cservice@welltraveled.net Customer Service Hours: Mon. Fri. 9:00 a.m. 6:00 p.m. (EST) Fire Sense, Mojave Sun, and Well Traveled Living are registered trademarks of Well Traveled Imports, Inc. All assembly instruction presentations are the property of Well Traveled Imports, Inc. and are protected by U.S. copyrights and trademarks. All rights reserved.