CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

Similar documents
EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

SECTION 915 CARBON MONOXIDE DETECTION

PLUMBING & CARBON MONOXIDE

This section shall take effect on June 27, 2015 and transition period effective date of this section and June 27, 2016

Large Family Daycare Guideline

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Residential-based Care Facility R-4 Guideline

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

[NOTE: Proposed additions to existing code language are highlighted in yellow.]

Iowa (2) Delete section and insert in lieu thereof the following new section:

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Carbon Monoxide Detectors in New and Existing Buildings

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Family Foster Home Fire Safety Evaluation Checklist Instructions

Residential Care Facilities Requirements

Agency for Health Care Administration

CHAPTER 7 ALTERATIONS LEVEL

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

S 2758 S T A T E O F R H O D E I S L A N D

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Recent Revisions and Proposed Key Changes to Fire Code

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

Residential Based Care Facility Guidelines

FIRE PREVENTION STANDARDS

Certificate of Inspection CHECKLIST

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

2012 NC Building Code Chapter 2, 602.4, , , Chapter 35 Cross-Laminated Timber. ( Item B-1)

Report on First Revisions with Statement June 2014 NFPA 101

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

Short Term Accommodations Fire Code Requirements

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Apartment Fire & Safety Inspection. City of Guadalupe

Agency for Health Care Administration

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

ENERGY EFFICIENCY AFTER DECEMBER 31, 2016

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Statutory Installation Requirements in 2007 Wisconsin Act 205

CHAPTER II BUILDINGS PART 1 BUILDING CODE PART 2 FLOOD PLAIN REGULATIONS. See Ordinance 3251 on file in the office of the Manager.

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

NFPA 101 Life Safety Code Culture change 2012

Agency for Health Care Administration

Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

REQUIREMENTS & GUIDELINES

For additional information regarding R-3.1 residential care facilities please contact (951)

PROPOSED Houston Amendments to the 2015 International Building Code

2012 International Fire Code Errata (Portions of text and tables not shown are unaffected by the errata)

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Mt. Crested Butte Code

Electrical Tech Note 107

From Your Building Inspector

Smoke & Carbon Monoxide

TABLE OF CONTENTS. Part I Administrative

WHEREAS, a photoelectric smoke alarm, in a smoldering fire, can alert a warning signal faster than a non-photoelectric smoke alarm; and

May 27, Mayor Thomas M. Roach Members of the Common Council City of White Plains 255 Main Street White Plains, New York 10601

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

SAF-BCF SECOND REVISIONS WITH STATEMENTS

January 1, 2014 Mandatory Effective Date

ARTICLE 25. FUEL GAS CODE

Amend Base Code. Amend Base Code. Amend Base Code. Disposition. (Statute, Rule, FBC, Industry) Y/N

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

Rental Housing Inspection Guide

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

TABLE OF CONTENTS. Part I Administrative... 1

ORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:

FIRE PREVENTION CODE

Township of Maplewood

DEALING WITH FIRE SAFETY

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

Habitability Guidelines

THE TOWNSHIP OF CRANBURY

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

Chapter BUILDING CODE*

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

Requirements for Smoke Detector / Carbon Monoxide/ Fire Extinguisher Certification

APPLICATION FOR Large Family Day Care Permit

Osceola County Department of Fire Rescue and Emergency Medical Services

Drexel Heights Fire District 2012 International Fire Code Amendments

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT

Great Lakes Building Systems, Inc.

Transcription:

The State Uniform Fire Prevention and Building Code (the Uniform Code) includes the publications that are incorporated by reference in Parts 1220 to 1227 of Title 19 of the New York Codes, Rules and Regulations (the NYCRR). Effective December 28, 2010, those publications will include the August 2010 editions of: the Residential Code of New York State (the 2010 RCNYS), the Building Code of New York State (the 2010 BCNYS), the Plumbing Code of New York State (the 2010 PCNYS), the Mechanical Code of New York State (the 2010 MCNYS), the Fuel Gas Code of New York State (the 2010 FGCNYS), the Fire Code of New York State (the 2010 FCNYS), the Property Maintenance Code of New York State (the 2010 PMCNYS), and the Existing Building Code of New York State (the 2010 EBCNYS). The 2010 RCNYS, 2010 BCNYS, 2010 PCNYS, 2010 MCNYS, 2010 FGCNYS, 2010 FCNYS, 2010 PMCNYS and 2010 EBCNYS are referred to collectively as the 2010 Code Books. Certain provisions in the 2010 Code Books have been changed, and certain new provisions have been added to the 2010 Code Books, by provisions included in the 19 NYCRR Parts 1220 to 1227. For the purposes of applying the 2010 Code Books in this State, the 2010 Code Books are deemed to be amended in the manner specified in the NYCRR. This Memorandum summarizes the amendments to the 2010 Code Books that have been made by the NYCRR. This Memorandum reflects actions taken by the State Fire Prevention and Building Code Council (the Code Council) through and including December 1, 2010. The Code Council may make further changes and additions to the 2010 Code Books at subsequent meetings of the Code Council. In addition, the Code Council may add new provisions to the Uniform Code from time to time by amending Part 1228 of Title 19 of the NYCRR. Regulated parties, code enforcement officials and 1 of 19

other interested parties may contact the Division of Code Enforcement and Administration for further information. Code Book SECTIONS CHANGED OR ADDED THROUGH DECEMBER 1, 2010 Incorporated by Reference in: Changed by: Section(s) Changed or Added: 2010 RCNYS 19 NYCRR Part 1220 19 NYCRR 1220.1(c) 313.2 313.4 2411.2.2 3509.7 App. J, Section J102 App. J, Section J704 App. J, Section J401.3 App. J, Section J501.3 App. J, Section J601.5 App. J, Section J803.2 App. J, Section J901.3 App. J, Section J1001.4 2010 BCNYS 19 NYCRR Part 1221 19 NYCRR 1221.1(c) Table 508.2 Table 508.3.3 2010 PCNYS 19 NYCRR Part 1222 N/A NONE 2010 MCNYS 19 NYCRR Part 1223 N/A NONE 2010 FGCNYS 19 NYCRR Part 1224 19 NYCRR 1224.1(c) Section 310.2.2 2010 FCNYS 19 NYCRR Part 1225 19 NYCRR 1225.1(c) Section 610 Section 1028.8.2 Section 1029.7 Section 1103.5 2010 PMCNYS 19 NYCRR Part 1226 N/A NONE 2010 EBCNYS 19 NYCRR Part 1227 19 NYCRR 1227.1(c) Section 506.1 2 of 19

2010 RCNYS Section R313.2 DESCRIPTION OF CHANGES / ADDITIONS MADE THROUGH DECEMEBR 1, 2010 The following sentence is added to end of this section: Existing dwellings not undergoing repair, alteration, change of occupancy, addition or relocation shall be provided with smoke alarms as required by Section 704 of the Property Maintenance Code of New York State or Section 907 of the Fire Code of New York State, as applicable, and shall be provided with carbon monoxide alarms as required by Section 610 of the Fire Code of New York State. 2010 RCNYS Section R313.4 2010 RCNYS Section 2411.2.2 2010 RCNYS Section 3509.7 2010 RCNYS App. J, Section J102 This Section ( Carbon monoxide alarms ) is amended and restated in its entirety. See attached Exhibit A for the amended and restated text of this Section. The second sentence of this Section is amended and restated in its entirety to read as follows: The bonding clamp shall be attached to the gas piping system on the down-stream side of the gas meter or regulator, in an unconcealed and readily accessible space, and as close as practicable to the point where the bonding jumper is connected to the electrical service grounding electrode system. The following exception is added to this Section: EXCEPTION: Gas piping systems that contain corrugated stainless steel tubing (CSST) shall be installed and bonded in accordance with Section G2411.2 of this code. New Section J102.6 is added to 2010 RCNYS Appendix J, Section J102. New Section J102.6 reads as follows: Section J102.6. Lead-based paint. In addition to requirements of this code, 40 CFR 745 (titled Lead-based Paint Poisoning Prevention in Certain Residential Structures ), a regulation issued and enforced by the Federal Environmental Protection Agency, applies to certain activities in buildings that may contain lead-based paint, including renovations performed for compensation in target housing and child-occupied facilities, abatement of lead-based paint hazards and other leadbased paint activities (as those terms are defined in 40 CFR Part 745). 2010 RCNYS App. J, Section J704. A new section AJ704 (including sections AJ704.1, AJ704.2, AJ704.3 and AJ704.4) is added to 2010 RCNYS Appendix J. See attached Exhibit B for the text of new Section AJ704. 2010 RCNYS App. J, Sections J401.3, J501.3, J601.5, J803.2, J901.3 and J1001.4 These Sections are amended and restated in their entirety. See attached Exhibit C for the amended and restated text of these Sections. 2010 BCNYS In Table 508.2 of the 2010 BCNYS, the entry for Storage rooms over 100 square feet in the 3 of 19

Table 508.2 2010 BCNYS Table 508.3.3 2010 FGCNYS Section 310.2.2 2010 FCNYS Section 610 2010 FCNYS Section 1028.8.2 2010 FCNYS Section 1029.7 2010 FCNYS Section 1103.5 2010 EBCNYS Section 506.1 ROOM OR AREA column ends with footnote b. This entry should end with footnote a. This entry is amended and restated in its entirety to read as follows: Storage rooms over 100 square feet a The following footnote e is added to this Table: e Commercial kitchens need not be separated from the restaurant seating areas that they serve The second sentence in this Section is amended and restated in its entirety to read as follows: The bonding clamp shall be attached to the gas piping system on the down-stream side of the gas meter or regulator, in an unconcealed and readily accessible space, and as close as practicable to the point where the bonding jumper is connected to the electrical service grounding electrode system. This Section ( Carbon Monoxide Alarms ) is amended and restated in its entirety. See attached Exhibit D for the amended and restated text of this section. This Section is amended and restated in its entirety to read as follows: 1028.8.2 Means of egress. Means of egress shall conform with Section 1028.8.2.1, 1028.8.2.2 or 1028.8.2.3. This Section is amended and restated in its entirety to read as follows: 1029.7 Exits signs. Exits signs shall comply with Sections 1029.7.1 through 1029.7.5. This Section is amended and restated in its entirety to read as follows: 1103.5 Dispensing of flammable and combustible liquids. The dispensing, transferring and storage of flammable and combustible liquids shall be in accordance with this chapter and Chapter 34. EXCEPTION: The dispensing, transferring and storage of flammable and combustible liquids in aircraft motor vehicle fuel-dispensing stations shall be in accordance with NFPA 407. The first sentence in the introductory portion of this Section (which reads Seismic provisions of this chapter shall only apply to buildings built after January 1, 2003. ) is deleted, and the introductory portion of this Section is amended and restated in its entirety to read as follows: 506.1 General. Repairs of structural elements shall comply with this section. 4 of 19

EXHIBIT A AMENDED AND RESTATED TEXT OF 2010 RCNYS SECTION R313.4 R313.4 Carbon monoxide alarms. This section covers the application, installation, performance and maintenance of carbon monoxide alarms and carbon monoxide detectors, and their components, in new one- and two-family dwellings and new townhouses. New bed and breakfast dwellings and new buildings which are under the custody, licensure, supervision or jurisdiction of a department or agency of the State of New York and which are regulated as one- or two-family dwellings or townhouses in accordance with established laws or regulations of that department or agency shall comply with the stricter of this section or Section 610 of the Fire Code of New York State. Existing one- and two-family dwellings, existing townhouses, existing bed and breakfast dwellings, and existing buildings which are under the custody, licensure, supervision or jurisdiction of a department or agency of the State of New York and which are regulated as one- or two-family dwellings or townhouses in accordance with established laws or regulations of that department or agency shall comply with Section 610 of the Fire Code of New York State. R313.4.1 General. Carbon monoxide alarms (or, where permitted, carbon monoxide detectors) shall be installed, operated and maintained in accordance with the provisions of this section, or in accordance with the provisions of NFPA 720. Exception: Carbon monoxide alarms and/or carbon monoxide detectors shall not be required in a building or structure that contains no carbon monoxide source. R313.4.2 Required locations. Carbon monoxide alarms shall be provided at each of the following locations within each dwelling unit: 1. On each story containing a sleeping area, within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 2. On each story that contains a carbon monoxide source. Exceptions. 5 of 19

1. Where coverage at a location is required by more than one provision of this section, providing one carbon monoxide alarm at such location shall be deemed to satisfy all such provisions. 2. In lieu of a carbon monoxide alarm, a carbon monoxide detector may be provided at any location where coverage is required, provided that such carbon monoxide detector is part of a system that causes an alarm to sound at such location when carbon monoxide is detected at such location. R313.4.3 Power source. Carbon monoxide alarms, carbon monoxide detectors and the alarm control units to which carbon monoxide detectors are connected shall receive their primary power from the building wiring, and shall be equipped with a battery backup system that automatically provides power from one or more batteries when primary power is interrupted. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. Exceptions. 1. Carbon monoxide alarms and carbon monoxide detectors installed in a building or structure without an electrical power source shall be battery operated. 2. In buildings that undergo repair, alteration, change of occupancy, addition or relocation in accordance with Appendix J, carbon monoxide alarms may be battery operated, cordtype or direct plug. R313.4.4 Equipment. Carbon monoxide alarms shall be listed and labeled as complying with UL 2034 or CAN/CSA 6.19. Carbon monoxide detectors shall be listed and labeled as complying with UL 2975 and shall meet the sensitivity testing and alarm thresholds of UL 2034 or CSA 6.19. Carbon monoxide alarms and carbon monoxide detectors shall be installed in accordance with this section and the manufacturer's installation instructions. R313.4.4.1 Maintenance and testing. Carbon monoxide alarms, carbon monoxide detectors, and alarm control units shall be maintained in an operative condition at all times. Carbon monoxide alarms, carbon monoxide detectors, and alarm control units shall be periodically tested in accordance with the manufacturer s instructions. The battery or batteries used as the primary or backup power source shall be replaced when low or when otherwise required by the manufacturer s instructions. Carbon monoxide 6 of 19

alarms, carbon monoxide detectors, and alarm control units shall be replaced or repaired when defective, and shall be replaced when they cease to operate as intended. R313.4.4.2 Disabling of alarms. No carbon monoxide alarm, carbon monoxide detector, or alarm control unit shall be removed or disabled, except for service, repair or replacement purposes. R313.4.5 Interconnection of carbon monoxide alarms. When more than one carbon monoxide alarm or carbon monoxide detector is required to be installed within an individual dwelling unit, sleeping unit or sleeping area, all carbon monoxide alarms and all carbon monoxide detectors in such dwelling unit, sleeping unit or sleeping area shall be interconnected. Exception: Interconnection is not required where battery operated, cord-type or direct plug carbon monoxide alarms and carbon monoxide detectors are permitted. 7 of 19

EXHIBIT B TEXT OF NEW 2010 RCNYS APPENDIX J, SECTION RAJ704 Section RAJ704. BED AND BREAKFAST DWELLINGS RAJ704.1 Scope. Owner-occupied one-family dwellings converted for use as bed and breakfast dwellings as defined in Section RAJ202 shall comply with this section. RAJ704.2 Occupancy. A residence converted to a bed and breakfast dwelling shall have no more than five sleeping rooms for accommodating up to 10 transient lodgers. RAJ704.3 Special conditions. A one-family dwelling is permitted to be converted for use as a bed and breakfast dwelling under the following conditions: 1. No sleeping rooms for transient use shall be located above the second story. 2. A fire-safety notice shall be affixed to the occupied side of the entrance door of each bedroom for transient use indicating: 1. Means of egress; 2. Location of means for transmitting fire alarms, if any; and 3. Evacuation procedures to be followed in the event of a fire or smoke condition or upon activation of a fire or smoke-detecting or other alarm device. RAJ704.4 Means of egress. Means of egress shall include at least one of the following alternatives: 1. A limited area sprinkler system installed in conformance with NFPA 13D protecting all interior stairs serving as a means of egress; 2. An exterior stair conforming to the requirements of RR311.1 and RR311.5 of this code, providing a second means of egress from all above grade stories or levels; or 8 of 19

3. An opening for emergency use conforming to the requirements of Section R310 of this code within each bedroom for transient use, such opening to have a sill not more than 14 feet above level grade directly below and, as permanent equipment, a portable escape ladder that attaches securely to such sill. Such ladder shall be constructed with rigid rungs designed to stand off from the building wall, shall be capable of sustaining a minimum load of 1,000 pounds, and shall extend to and provide unobstructed egress to open space at grade. 9 of 19

EXHIBIT C AMENDED AND RESTATED TEXT OF 2010 RCNYS APPENDIX J, SECTIONS AJ401.3, AJ501.3, AJ601.5, AJ 803.2, AJ901.3 AND AJ1001.4 AJ401.3 Flood hazard areas. In flood hazard areas, repairs that constitute substantial improvement shall require that the building comply with Section R324 of this code. AJ501.3 Flood hazard areas. In flood hazard areas, alterations that constitute substantial improvement shall require that the building comply with Section R324 of this code. AJ601.5 Flood hazard areas. In flood hazard areas, alterations that constitute substantial improvement shall require that the building comply with Section R324 of this code. AJ803.2 Flood hazard areas. Additions and foundations in flood hazard areas shall comply with the following requirements: 1. For horizontal additions that are structurally interconnected to the existing building: 1.1. If the addition and all other proposed work, when combined, constitute substantial improvement, the existing building and the addition shall comply with Section R324 of this code. 1.2. If the addition constitutes substantial improvement, the existing building and the addition shall comply with Section R324. 2. For horizontal additions that are not structurally interconnected to the existing building: 2.1. The addition shall comply with Section R324. 10 of 19

2.2. If the addition and all other proposed work, when combined, constitute substantial improvement, the existing building and the addition shall comply with Section R324. 3. For vertical additions and all other proposed work that, when combined, constitute substantial improvement, the existing building shall comply with Section R324. 4. For a new, replacement, raised, or extended foundation, if the foundation work and all other proposed work, when combined, constitute substantial improvement, the existing building shall comply with Section R324. AJ901.3 Flood hazard areas. In flood hazard areas, if all proposed work, including repairs, work required because of a change of occupancy, and alterations, constitutes substantial improvement, then the existing building shall comply with Section R324. AJ1001.4 Flood hazard areas. If relocated or moved into a flood hazard area, buildings shall comply with Section R324. 11 of 19

EXHIBIT D AMENDED AND RESTATED TEXT OF 2010 FCNYS SECTION 610 SECTION 610 CARBON MONOXIDE ALARMS 610.1. General. Section 610 covers the application, installation, performance and maintenance of carbon monoxide alarms and carbon monoxide detectors, and their components, in new and existing one-and twofamily dwellings; multiple single-family dwellings (townhouses); buildings owned as condominiums or cooperatives and containing dwelling units; bed and breakfast dwellings; and other buildings and structures which contain one or more dwelling units, sleeping units or sleeping areas and which are classified, in whole or in part, in one or more of the following occupancy Groups: E, I-1, I-2 (except hospitals), I-4, R-l, R-2, R-3 or R-4. Carbon monoxide alarms (or, where permitted, carbon monoxide detectors) shall be provided in all new and existing buildings and structures described in Section 610.1, without regard to the date of construction of the building or structure and without regard to whether such building or structure shall or shall not have been offered for sale. Carbon monoxide alarms (or, where permitted, carbon monoxide detectors) shall be installed, operated and maintained in accordance with the provisions of Section 610 or, in the alternative, in accordance with the provisions of NFPA 720. Exception: Carbon monoxide alarms and/or carbon monoxide detectors shall not be required in a building or structure that contains no carbon monoxide source. 610.2. Definitions. For the purposes of this Section 610, the following terms shall have the following meanings: Carbon monoxide alarm. A single or multiple-station device that has (1) a sensor capable of detecting the presence of carbon monoxide and (2) an alarm that sounds when carbon monoxide is detected. Carbon monoxide detector. A device that (1) has a sensor capable of detecting the presence of carbon monoxide and (2) is connected to an alarm control unit that sounds an alarm when carbon monoxide is detected. Carbon monoxide source. Any appliance, equipment, device or system that may emit carbon monoxide (including, but not limited to, fuel fired furnaces; fuel fired boilers; space heaters with 12 of 19

pilot lights or open flames; kerosene heaters; wood stoves; fireplaces; and stoves, ovens, dryers, water heaters and refrigerators that use gas or liquid fuel), garages, and other motor vehicle related occupancies. Dwelling unit. A single unit providing complete, independent living facilities for one or more persons, including permanent provisions for living, sleeping, eating, cooking and sanitation. Dwelling units include, but are not limited to, one-family dwellings, each unit in a two-family dwelling, each unit in a multiple single-family dwelling (townhouse), bed and breakfast dwellings, apartments, and dormitory suites having living areas, bedrooms, bathrooms and kitchens. Sleeping area. A room or space that can be used, either on an occasional or permanent basis, for sleeping. Sleeping areas include, but are not limited to, bedrooms and places where children sleep in a daycare facility. Sleeping unit. A room or space in which people sleep, which can also include permanent provisions for living, eating, and either sanitation or kitchen facilities but not both. Such rooms and spaces that are also part of a dwelling unit are not sleeping units. Sleeping units include, but are not limited to, dormitory suites with living areas, bedrooms and bathrooms. 610.3. Required locations. Carbon monoxide alarms shall be provided in the locations determined pursuant to Section 610.3. Exceptions: 1. Where coverage at a location is required by more than one provision of Section 610.3, providing one carbon monoxide alarm at such location shall be deemed to satisfy all such provisions. 2. In lieu of a carbon monoxide alarm, a carbon monoxide detector may be provided at any location where coverage is required, provided that such carbon monoxide detector is part of a system that causes an alarm to sound at such location when carbon monoxide is detected at such location. 13 of 19

610.3.1. One- Family Dwellings. 610.3.1.1. Buildings constructed on or after January 1, 2008. 610.3.1.1.1. A carbon monoxide alarm shall be provided on each story containing a sleeping area, within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 610.3.1.1.2. A carbon monoxide alarm shall be provided on each story that contains a carbon monoxide source. 610.3.1.2. Buildings constructed prior to January 1, 2008. A carbon monoxide alarm shall be provided on the lowest story containing a sleeping area, within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 610.3.2. Two-family dwellings, multiple single-family dwellings (townhouses), and buildings owned as condominiums or cooperatives and containing dwelling units. 610.3.2.1. Buildings constructed on or after January 1, 2008. Within each dwelling unit: 610.3.2.1.1. A carbon monoxide alarm shall be provided on every story containing a sleeping area, within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 610.3.2.1.2. A carbon monoxide alarm shall be provided on every story that contains a carbon monoxide source. 610.3.2.2. Buildings constructed prior to January 1, 2008. Within each dwelling unit, a carbon monoxide alarm shall be provided on the lowest story containing a sleeping area, within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 14 of 19

610.3.3. Bed and breakfast dwellings and buildings and structures which (1) contain one or more sleeping areas, (2) are classified in one or more of the following occupancy Groups: E, I-2 (except hospitals), I-4, R-l, R-2, R-3 or R-4, and (3) are not covered by section 610.3.1 or section 610.3.2. 610.3.3.1. Buildings and structures constructed on or after January 1, 2008. 610.3.3.1.1. Dwelling units and sleeping units. Carbon monoxide alarms shall be provided within each dwelling unit and within each sleeping unit at the locations specified in this section 610.3.3.1.1. 610.3.3.1.1.1. In a dwelling unit or sleeping unit that contains a carbon monoxide source, a carbon monoxide alarm shall be provided on each story that contains a sleeping area. The carbon monoxide alarm shall be located within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. In addition, a carbon monoxide alarm shall be provided within each sleeping area that contains a carbon monoxide source. 610.3.3.1.1.2. In a dwelling unit or sleeping unit which contains no carbon monoxide source, but which is located (in whole or in part) on the same story as a carbon monoxide source, a carbon monoxide alarm shall be provided on each story that contains a sleeping area. The carbon monoxide alarm shall be located within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 610.3.3.1.1.3. In a dwelling unit or sleeping unit which contains no carbon monoxide source and which is not located (in whole or in part) on the same story as a carbon monoxide source, no carbon monoxide alarm is required. 610.3.3.1.2. Sleeping areas not located within a dwelling unit. Carbon monoxide alarms shall be provided within sleeping areas that are not located within a dwelling unit when required by this section 610.3.3.1.2. 15 of 19

610.3.3.1.2.1. A carbon monoxide alarm shall be provided within each sleeping area that contains a carbon monoxide source. 610.3.3.1.2.2. A carbon monoxide alarm shall be provided within each sleeping area that is located (in whole or in part) on the same story as a carbon monoxide source. 610.3.3.1.3. Stories which (1) contain a carbon monoxide source and (2) contain no dwelling unit, sleeping unit or sleeping area. A carbon monoxide alarm shall be provided on every story which (1) contains a carbon monoxide source and (2) contains no dwelling unit, sleeping unit or sleeping area. 610.3.3.2. Buildings and structures constructed prior to January 1, 2008. 610.3.3.2.1. Dwelling units and sleeping units. Carbon monoxide alarms shall be provided within each dwelling unit and within each sleeping unit at the locations specified in this section 610.3.3.2.1. 610.3.3.2.1.1. In a dwelling unit or sleeping unit that contains a carbon monoxide source, a carbon monoxide alarm shall be provided on the lowest story that contains a sleeping area. The carbon monoxide alarm shall be located within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. In addition, a carbon monoxide alarm shall be provided within each sleeping area that contains a carbon monoxide source. 610.3.3.2.1.2. In a dwelling unit or sleeping unit which contains no carbon monoxide source, but which is located (in whole or in part) on the same story as a carbon monoxide source, a carbon monoxide alarm shall be provided on the lowest story that contains a sleeping area. The carbon monoxide alarm shall be located within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 16 of 19

610.3.3.2.1.3. In a dwelling unit or sleeping unit which contains no carbon monoxide source and which is not located (in whole or in part) on the same story as a carbon monoxide source, no carbon monoxide alarm is required. 610.3.3.2.2. Sleeping areas not located within a dwelling unit. Carbon monoxide alarms shall be provided within sleeping areas that are not located within a dwelling unit when required by this section 610.3.3.2.2. 610.3.3.2.2.1. A carbon monoxide alarm shall be provided within each sleeping area that contains a carbon monoxide source. 610.3.3.2.2.2. A carbon monoxide alarm shall be provided within each sleeping area that is located (in whole or in part) on the same story as a carbon monoxide source. 610.3.3.2.3. Stories which (1) contain a carbon monoxide source and (2) contain no dwelling unit, sleeping unit or sleeping area. A carbon monoxide alarm shall be provided on every story which (1) contains a carbon monoxide source and (2) contains no dwelling unit, sleeping unit or sleeping area. 610.3.4. Buildings and structures classified in Occupancy Group I-1: 610.3.4.1. Buildings and structures constructed on or after January 1, 2008. 610.3.4.1.1. A carbon monoxide alarm shall be provided on every story containing a sleeping area, within 15 feet of the sleeping area. More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 610.3.4.1.2. A carbon monoxide alarm shall be provided on every story that contains a carbon monoxide source. 610.3.4.2. Buildings and structures constructed prior to January 1, 2008. A carbon monoxide alarm shall be provided on every story containing a sleeping area, within 15 feet of the sleeping area. 17 of 19

More than one carbon monoxide alarm shall be provided where necessary to assure that no sleeping area on such story is more than 15 feet away from a carbon monoxide alarm. 610.4. New carbon monoxide source. This section applies when a carbon monoxide source is installed in, or added, or attached to a building or structure after the date of original construction of the building or structure. This section applies without regard to the date of original construction of the building or structure. When a carbon monoxide source is installed in, or added, or attached to a building or structure, the building or structure (with such new carbon monoxide source) shall be evaluated as if such building or structure (with such new carbon monoxide source) were constructed on or after January 1, 2008, and a carbon monoxide alarm shall be provided at each location determined for such building or structure (with such new carbon monoxide source) pursuant to Section 610.3. Exception: In lieu of a carbon monoxide alarm, a carbon monoxide detector may be provided at any location where coverage is required, provided that such carbon monoxide detector is part of a system that causes an alarm to sound at such location when carbon monoxide is detected at such location. 610.5. Power source. Carbon monoxide alarms, carbon monoxide detectors, and the alarm control units to which carbon monoxide detectors are connected shall receive their primary power from the building wiring, and shall be equipped with a battery backup system that automatically provides power from one or more batteries when primary power is interrupted. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. Exceptions: 1. Carbon monoxide alarms and carbon monoxide detectors installed in a building or structure without an electrical power source shall be battery operated. 2. Carbon monoxide alarms and carbon monoxide detectors installed in a building or structure constructed prior to January 1, 2008 may be battery operated, cord-type or direct plug. 3. Carbon monoxide alarms and carbon monoxide detectors installed in a building or structure pursuant to Section 610.4 may be battery operated, cord-type or direct plug. 18 of 19

4. In the case of a building or structure constructed on or after January l, 2008 and prior to the effective date of this code, when a carbon monoxide alarm or carbon monoxide detector is provided at a location where coverage was not required by prior versions of the Uniform Code, but where coverage is required by Section 6l0, such carbon monoxide alarm or carbon monoxide detector may be battery operated, cord-type or direct plug. 610.6. Equipment. Carbon monoxide alarms shall be listed and labeled as complying with UL 2034 or CAN/CSA 6.19. Carbon monoxide detectors shall be listed and labeled as complying with UL 2075 and shall meet the sensitivity testing and alarm thresholds of UL 2034 or CAN/CSA 6.19. Carbon monoxide alarms, carbon monoxide detectors and alarm control units shall be installed in accordance with Section 610 and the manufacturer's installation instructions. 610.6.1. Connection of multiple carbon monoxide alarms and detectors. When more than one carbon monoxide alarm is required to be installed within an individual dwelling unit, sleeping unit, or sleeping area, all carbon monoxide alarms in such dwelling unit, sleeping unit, or sleeping area shall be interconnected. Exception: Interconnection is not required where battery operated, cord-type or direct plug carbon monoxide alarms and carbon monoxide detectors are permitted. 610.6.2. Maintenance and testing. Carbon monoxide alarms, carbon monoxide detectors, and alarm control units shall be maintained in an operative condition at all times. Carbon monoxide alarms, carbon monoxide detectors, and alarm control units shall be periodically tested in accordance with the manufacturer's instructions. The battery or batteries used as the primary or backup power source shall be replaced when low or when otherwise required by the manufacturer's instructions. Carbon monoxide alarms, carbon monoxide detectors, and alarm control units shall be replaced or repaired where defective, and shall be replaced when they cease to operate as intended. 610.6.3. Disabling of alarms. No carbon monoxide alarm, carbon monoxide detector, or alarm control unit shall be removed or disabled, except for service, repair or replacement purposes. 19 of 19